A Review of Deep Learning for Screening, Diagnosis, and Detection of Glaucoma Progression
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
Because of recent advances in computing technology and the availability of large datasets, deep learning has risen to the forefront of artificial intelligence, with performances that often equal, or sometimes even exceed, those of human subjects on a variety of tasks, especially those related to image classification and pattern recognition. As one of the medical fields that is highly dependent on ancillary imaging tests, ophthalmology has been in a prime position to witness the application of deep learning algorithms that can help analyze the vast amount of data coming from those tests. In particular, glaucoma stands as one of the conditions where application of deep learning algorithms could potentially lead to better use of the vast amount of information coming from structural and functional tests evaluating the optic nerve and macula. The purpose of this article is to critically review recent applications of deep learning models in glaucoma, discussing their advantages but also focusing on the challenges inherent to the development of such models for screening, diagnosis and detection of progression. After a brief general overview of deep learning and how it compares to traditional machine learning classifiers, we discuss issues related to the training and validation of deep learning models and how they specifically apply to glaucoma. We then discuss specific scenarios where deep learning has been proposed for use in glaucoma, such as screening with fundus photography, and diagnosis and detection of glaucoma progression with optical coherence tomography and standard automated perimetry. Translational Relevance: Deep learning algorithms have the potential to significantly improve diagnostic capabilities in glaucoma, but their application in clinical practice requires careful validation, with consideration of the target population, the reference standards used to build the models, and potential sources of bias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040
Tham, Y.-C., Li, X., Wong, T. Y., Quigley, H. A., Aung, T., & Cheng, C.-Y. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.013 · Cited by 7,159
Weiss, K., Khoshgoftaar, T. M., & Wang, D. (2016) · Journal of Big Data · doi:10.1186/s40537-016-0043-6 · Cited by 6,260
The Pathophysiology and Treatment of Glaucoma: A Review
Weinreb, R. N., Aung, T., & Medeiros, F. A. (2014) · JAMA · doi:10.1001/jama.2014.3192 · Cited by 4,210
Self-citationTing, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Chollet, F. (2017) · Cited by 1,158
Li, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830
Medeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.069 · Cited by 649
Self-citationGanglion cell losses underlying visual field defects from experimental glaucoma.
Harwerth, R. S., Carter‐Dawson, L. D., Shen, F., Smith, E. L., III, & Crawford, M. L. J. (1999) · PubMed · Cited by 544
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Cheung, C. Y.-L., Weinreb, R. N., Qiu, Q., Liu, S., Li, H., Xu, G., Fan, N., Huang, L., Pang, C.-P., et al. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.013 · Cited by 486
Medeiros, F. A. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.6.827 · Cited by 455
Self-citationExpert Agreement in Evaluating the Optic Disc for Glaucoma
Varma, R., Steinmann, W. C., & Scott, I. U. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31990-6 · Cited by 330
Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
Liu, H., Li, L., Wormstone, I. M., Qiao, C., Zhang, C., Liu, P., Li, S., Wang, H., Mou, D., Pang, R., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.3501 · Cited by 307
Development of machine learning models for diagnosis of glaucoma
Kim, S. J., Cho, K. J., & Oh, S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177726 · Cited by 266
Asaoka, R., Murata, H., Hirasawa, K., Fujino, Y., Matsuura, M., Miki, A., Kanamoto, T., Ikeda, Y., Mori, K., Iwase, A., et al. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.10.007 · Cited by 254
Development of a deep residual learning algorithm to screen for glaucoma from fundus photography
Shibata, N., Tanito, M., Mitsuhashi, K., Fujino, Y., Matsuura, M., Murata, H., & Asaoka, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-33013-w · Cited by 249
Medeiros, F. A., Jammal, A. A., & Thompson, A. C. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.12.033 · Cited by 249
Self-citationDetecting Preperimetric Glaucoma with Standard Automated Perimetry Using a Deep Learning Classifier
Asaoka, R., Murata, H., Iwase, A., & Araie, M. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.05.029 · Cited by 248
A deep learning model for the detection of both advanced and early glaucoma using fundus photography
Ahn, J. M., Kim, S., Ahn, K.-S., Cho, S.-H., Lee, K. B., & Kim, U. S. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207982 · Cited by 246
Detecting Structural Progression in Glaucoma with Optical Coherence Tomography
Tatham, A. J., & Medeiros, F. A. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.07.015 · Cited by 229
Self-citationMuhammad, H., Fuchs, T. J., De Cuir, N., De Moraes, C. G., Blumberg, D. M., Liebmann, J. M., Ritch, R., & Hood, D. C. (2017) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000765 · Cited by 227
Comparison of machine learning and traditional classifiers in glaucoma diagnosis
Chan, K., Lee, T.-W., Sample, P. A., Goldbaum, M. H., Weinreb, R. N., & Sejnowski, T. J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.802012 · Cited by 226
Neural Losses Correlated with Visual Losses in Clinical Perimetry
Harwerth, R. S., Carter‐Dawson, L. D., Smith, E. L., BARNES, G. R., Holt, W. F., & Crawford, M. L. J. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0227 · Cited by 220
Jampel, H. D., Friedman, D., Quigley, H., Vitale, S., Miller, R., Knezevich, F., & Ding, Y. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.07.023 · Cited by 214
A feature agnostic approach for glaucoma detection in OCT volumes
Maetschke, S., Antony, B., Ishikawa, H., Wollstein, G., Schuman, J., & Garnavi, R. (2019) · PLOS ONE · doi:10.1371/journal.pone.0219126 · Cited by 213
Shickel (2018) · doi:10.1109/jbhi.6221020 · Cited by 203
Burgansky-Eliash, Z., Wollstein, G., Chu, T., Ramsey, J. D., Glymour, C., Noecker, R. J., Ishikawa, H., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0366 · Cited by 203
Prevalence of Glaucoma in an Urban West African Population: The Tema Eye Survey
Budenz, D. L., Barton, K., Whiteside-de Vos, J., Schiffman, J., Bandi, J., Nolan, W., Herndon, L., Kim, H., Hay-Smith, G., Tielsch, J. M., et al. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.1686 · Cited by 188
Deep Learning and Glaucoma Specialists
Phene, S., Dunn, R. C., Hammel, N., Liu, Y., Krause, J., Kitade, N., Schaekermann, M., Sayres, R., Wu, D. J., Bora, A., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.024 · Cited by 186
Self-citationAbrams, L. S., Scott, I. U., Spaeth, G. L., Quigley, H. A., & Varma, R. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31118-3 · Cited by 181
Forecasting future Humphrey Visual Fields using deep learning
Wen, J. C., Lee, C. S., Keane, P. A., Xiao, S., Wu, Y., Rokem, A., Chen, P. P., & Lee, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0214875 · Cited by 169
Thompson, A. C., Jammal, A. A., Berchuck, S. I., Mariottoni, E. B., & Medeiros, F. A. (2020) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.5983 · Cited by 160
Self-citationFu, H., Baskaran, M., Xu, Y., Lin, S., Wong, D. W. K., Liu, J., Tun, T. A., Mahesh, M., Perera, S., & Aung, T. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.02.028 · Cited by 157
Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry.
Goldbaum, M. H., Sample, P. A., Chan, K., Williams, J., Lee, T.-W., Blumenthal, E. Z., Girkin, C. A., Zangwill, L. M., Bowd, C., B, T. J. S. A., et al. (2002) · PubMed · Cited by 152
Patterns of functional vision loss in glaucoma determined with archetypal analysis
Elze, T., Pasquale, L. R., Shen, L. Q., Chen, T. C., Wiggs, J. L., & Bex, P. J. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.1118 · Cited by 147
Li, F., Wang, Z., Qu, G., Song, D., Yuan, Y., Xu, Y., Gao, K., Luo, G., Xiao, Z., Lam, D. S. C., et al. (2018) · BMC Medical Imaging · doi:10.1186/s12880-018-0273-5 · Cited by 137
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.01.003 · Cited by 135
Self-citationAwareness of Incident Open-angle Glaucoma in a Population Study
Hennis, A. J. M., Wu, S., Nemesure, B. B., Honkanen, R., & Leske, M. C. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2007.06.013 · Cited by 125
Jammal, A. A., Thompson, A. C., Mariottoni, E. B., Berchuck, S. I., Urata, C. N., Estrela, T., Wakil, S. M., Costa, V. P., & Medeiros, F. A. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.11.006 · Cited by 125
Self-citationXu, B. Y., Chiang, M., Chaudhary, S., Kulkarni, S., Pardeshi, A. A., & Varma, R. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.08.004 · Cited by 122
Christopher, M. A., Belghith, A., Weinreb, R. N., Bowd, C., Goldbaum, M. H., Saunders, L. J., Medeiros, F. A., & Zangwill, L. M. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-23387 · Cited by 122
Self-citationDetection of Longitudinal Visual Field Progression in Glaucoma Using Machine Learning
Yousefi, S., Kiwaki, T., Zheng, Y., Sugiura, H., Asaoka, R., Murata, H., Lemij, H. G., & Yamanishi, K. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.06.007 · Cited by 120
Yousefi, S., Goldbaum, M. H., Balasubramanian, M., Jung, T., Weinreb, R. N., Medeiros, F. A., Zangwill, L. M., Liebmann, J. M., Girkin, C. A., & Bowd, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2295605 · Cited by 117
Self-citationOwsley, C., McGwin, G., Lee, D. J., Lam, B. L., Friedman, D. S., Gower, E. W., Haller, J. A., Hark, L. A., & Saaddine, J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.4652 · Cited by 114
Clinical Utility of Optical Coherence Tomography in Glaucoma
Dong, Z. M., Wollstein, G., & Schuman, J. S. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19933 · Cited by 114
Interpretation of automated perimetry for glaucoma by neural network.
Goldbaum, M. H., Sample, P. A., White, H., Côlt, B., Raphaelian, P., Fechtner, R. D., & Weinreb, R. N. (1994) · PubMed · Cited by 111
Devalla, S. K., Chin, K. S., Mari, J.-M., Tun, T. A., Strouthidis, N. G., Aung, T., Thiéry, A. H., & Girard, M. J. A. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22617 · Cited by 110
A Deep Learning Algorithm to Quantify Neuroretinal Rim Loss From Optic Disc Photographs
Thompson, A. C., Jammal, A. A., & Medeiros, F. A. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.01.011 · Cited by 108
Self-citationDeep learning-based automated detection of glaucomatous optic neuropathy on color fundus photographs
Li, F., Yan, L., Wang, Y., Shi, J., Chen, H., Zhang, X., Jiang, M., Wu, Z., & Zhou, K. (2020) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-020-04609-8 · Cited by 102
Direct Cup-to-Disc Ratio Estimation for Glaucoma Screening via Semi-Supervised Learning
Zhao, R., Chen, X., Liu, X., Chen, Z., Guo, F., & Li, S. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2934477 · Cited by 94
Neural Networks to Identify Glaucoma With Structural and Functional Measurements
Brigatti, L., Hoffman, D. C., & Caprioli, J. (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75425-x · Cited by 93
Visual Field Prediction using Recurrent Neural Network
Park, K., Kim, J., & Lee, J. W. (2019) · Scientific Reports · doi:10.1038/s41598-019-44852-6 · Cited by 91
Bowd, C., Hao, J., Tavares, I. M., Medeiros, F. A., Zangwill, L. M., Lee, T.-W., Sample, P. A., Weinreb, R. N., & Goldbaum, M. H. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1083 · Cited by 86
Self-citationA deep learning approach to automatic detection of early glaucoma from visual fields
Kucur, Ş. S., Holló, G., & Sznitman, R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206081 · Cited by 82
Berchuck, S., Mukherjee, S., & Medeiros, F. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-54653-6 · Cited by 75
Self-citationSample, P. A., Boden, C., Zhang, Z., Pascual, J. P., Lee, T.-W., Zangwill, L. M., Weinreb, R. N., Crowston, J. G., Hoffmann, E. M., Medeiros, F. A., et al. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1168 · Cited by 67
Self-citationYousefi, S., Balasubramanian, M., Goldbaum, M. H., Medeiros, F. A., Zangwill, L. M., Weinreb, R. N., Liebmann, J. M., Girkin, C. A., & Bowd, C. (2016) · Translational Vision Science & Technology · doi:10.1167/tvst.5.3.2 · Cited by 67
Self-citationFactors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples
Hardin, J. S., Taibbi, G., Nelson, S. C., Chao, D., & Vizzeri, G. (2015) · Journal of Ophthalmology · doi:10.1155/2015/746150 · Cited by 65
Murata, H., Araie, M., & Asaoka, R. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14625 · Cited by 64
Wang, M., Tichelaar, J. G., Pasquale, L. R., Shen, L. Q., Boland, M. V., Wellik, S. R., Moraes, C. G. D., Myers, J. S., Ramulu, P. Y., Kwon, M., et al. (2020) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.5413 · Cited by 61
Chan, H. H. L., Ong, D. N., Kong, Y. X. G., O’Neill, E. C., Pandav, S. S., Coote, M., & Crowston, J. G. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.01.024 · Cited by 60
Mariottoni, E. B., Jammal, A. A., Urata, C. N., Berchuck, S. I., Thompson, A. C., Estrela, T., & Medeiros, F. A. (2020) · Scientific Reports · doi:10.1038/s41598-019-57196-y · Cited by 58
Self-citationGoldbaum, M. H., Sample, P. A., Zhang, Z., Chan, K., Hao, J., Lee, T.-W., Boden, C., Bowd, C., Bourne, R., Zangwill, L. M., et al. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1167 · Cited by 51
Rogers, T. W., Jaccard, N., Carbonaro, F., Lemij, H. G., Vermeer, K. A., Reus, N. J., & Trikha, S. (2019) · Eye · doi:10.1038/s41433-019-0510-3 · Cited by 47
Shigueoka, L., de Vasconcellos, J. P. C., Schimiti, R. B., Reis, A. S. C., de Oliveira, G. O., Gomi, E. S., Vianna, J. R., Lisboa, R. D. D. R., Medeiros, F. A., & Costa, V. P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207784 · Cited by 47
Self-citationMore Accurate Modeling of Visual Field Progression in Glaucoma: ANSWERS
Zhu, H., Crabb, D. P., Ho, T., & Garway‐Heath, D. F. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-16957 · Cited by 46
Goldbaum, M. H., Lee, I., Jang, G., et al. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8363 · Cited by 45
Sample, P. A., Chan, K., Boden, C., Lee, T.-W., Blumenthal, E. Z., Weinreb, R. N., Bernd, A. S., Pascual, J. P., Hao, J., B, T. J. S. A., et al. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-0343 · Cited by 44
Miller, S. E., Thapa, S., Robin, A. L., Niziol, L. M., Ramulu, P. Y., Woodward, M. A., Paudyal, I., Pitha, I., Kim, T. N., & Newman-Casey, P. A. (2017) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2017.07.010 · Cited by 42
Medeiros, F. A., Weinreb, R. N., Moore, G. H., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.10.003 · Cited by 40
Self-citationUsing Kalman Filtering to Forecast Disease Trajectory for Patients With Normal Tension Glaucoma
Garcia, G. P., Nitta, K., Lavieri, M. S., Andrews, C., Liu, X., Lobaza, E., Oyen, M. P. V., Sugiyama, K., & Stein, J. D. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.10.012 · Cited by 39
Lee, J., Kim, Y. K., Jeoung, J. W., Ha, A., Kim, Y. W., & Park, K. H. (2019) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-019-00706-2 · Cited by 36
An objective structural and functional reference standard in glaucoma
Mariottoni, E. B., Jammal, A. A., Berchuck, S. I., Shigueoka, L., Tavares, I. M., & Medeiros, F. A. (2021) · Scientific Reports · doi:10.1038/s41598-021-80993-3 · Cited by 34
Self-citationLearning from healthy and stable eyes: A new approach for detection of glaucomatous progression
Belghith, A., Bowd, C., Medeiros, F. A., Balasubramanian, M., Weinreb, R. N., & Zangwill, L. M. (2015) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2015.04.002 · Cited by 33
Self-citationLikelihood Ratios for Glaucoma Diagnosis Using Spectral-Domain Optical Coherence Tomography
Lisboa, R. D. D. R., Mansouri, K., Zangwill, L. M., Weinreb, R. N., & Medeiros, F. A. (2013) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2013.06.017 · Cited by 22
Self-citationRoh, K. H., Jeoung, J. W., Park, K. H., Yoo, B. W., & Kim, D. M. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.11.008 · Cited by 21
Cited by
Survey on Explainable AI: From Approaches, Limitations and Applications Aspects
Yang, W., Wei, Y., Wei, H., Chen, Y., Huang, G., Li, X., Li, R., Yao, N., Wang, X., Gu, X., et al. (2023) · Human-Centric Intelligent Systems · doi:10.1007/s44230-023-00038-y · Cited by 240
“For example, for glaucoma screening, doctors can use intraocular pressure testing, visual field testing, and manual inspection of the optic disc to diagnose the disease and give the cause and pathology based on the patient’s symptoms and pathological reports [154].”
Background
Metadata
- Authors
- Thompson, A. C., Jammal, A. A., & Medeiros, F. A.
- Venue
- Translational Vision Science & Technology
- Published
- 2020-07-22
- Volume
- 9
- Issue
- 2
- Pages
- 42
- ISSN
- 2164-2591 (ISSN-L)
- OpenAlex
- W3045215429
- Cited by
- 195
- References
- 79
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.