ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 901–1,000 of 1,000
ปริมาณรังสีที่ผู้ป่วยได้รับจากการถ่ายภาพรังสี ทรวงอกที่งานรังสีเทคนิค ศูนย์การแพทย์กาญจนาภิเษก
จิวะพงศ์, ศ., พัฒนาดิสัย, บ., & จํารูญสาย, ส. (2023) · Siriraj Medical Bulletin · doi:10.33192/smb.v16i1.258686 · Cited by 1
Mohammadbeigi, A., Shouraki, J. K., Ebrahiminik, H., Nouri, M., Bagheri, H., Moradi, H., Azizi, A., Fadaee, N., Soltanzadeh, T., & Moghimi, Y. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad245 · Cited by 1
Analysis of Indonesia regional radiation dose profile for general radiography and CT-scan
Kunarsih, E., Pratama, I. B. G. P., & Sudradjat (2023) · AIP conference proceedings · doi:10.1063/5.0173057 · Cited by 1
Diartama, A. A. A., Suputra, C. G. B., Mahendrayana, I. M. A., & Wirajaya, I. W. A. (2024) · Jurnal Medika Malahayati · doi:10.33024/jmm.v8i1.12721 · Cited by 1
Nomura, H. E. R., Arteaga, M. V. V., Peralta, S. L. A., Collazos, L. V. S., Vázquez-Bañuelos, J., Campillo-Rivera, G. E., & Vega-Carrillo, H. R. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.111942 · Cited by 1
Ouaggou, I. A., Bakari, D., Zerfaoui, M., Rrhioua, A., Oulhouq, Y., Benmessaoud, M., & Hadda, H. O. (2024) · Radiation effects and defects in solids · doi:10.1080/10420150.2024.2364200 · Cited by 1
Long-term Reproducibility Evaluation of Fluoroscopy Dose Rate in Angiography Equipment
Mori, K., Makabe, K., Sekiguchi, R., Negishi, T., & Tsuchida, T. (2024) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2024-1490 · Cited by 1
Mori, K., Negishi, T., Makabe, K., & Matsukura, K. (2025) · Radiological Physics and Technology · doi:10.1007/s12194-025-00915-0 · Cited by 1
Lee, J. A., Kim, S. R., Yoon, S. H., Kim, J. S., Yang, H. J., & Kim, G. H. (2022) · YUHSpace (Yonsei University Medical Library) · doi:10.52547/ijrr.20.3.8 · Cited by 1
Gonçalves, J. M. F. (2019) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/ppw5-j166 · Cited by 1
Measurement of the average radiation dose to patients during intracranial aneurysm coil embolization
Peter, Y. (2019) · Cited by 1
Forbrig, R., Özpeynirci, Y., Grasser, M., Dorn, F., Liebig, T., & Trumm, C. G. (2021) · European Radiology · doi:10.1007/s00330-021-07874-1 · Cited by 1
Innan, Y. (2020) · Chula Digiverse · doi:10.58837/chula.the.2020.319 · Cited by 1
Velasco, F. M., Bellotti, M., & Andrés, P. (2024) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2024.2233 · Cited by 1
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
“2,67,68 The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.”
Student radiographers’ knowledge and experience of lateral hip X-ray positioning: A survey
Clarke, L., & Lockwood, P. (2024) · Radiography · doi:10.1016/j.radi.2024.08.011
Chinene, B. (2022) · DUT Open Scholar (Durban University of Technology) · doi:10.51415/10321/4465
Wu, S., Zhou, C., Xu, Y., Qiao, W., Xia, L., Li, Y., Huang, C., He, H., Deng, D., Dai, W., et al. (2024) · Chinese Journal of Academic Radiology · doi:10.1007/s42058-024-00172-x
Hasan, N., Rizk, C., Marzooq, F., Khan, K. J., Alkhaja, M., & Babikir, E. (2024) · Journal of medical imaging · doi:10.1117/1.jmi.11.4.043502
Dickinson, N. J., & Dunn, M. (2020) · British Journal of Radiology · doi:10.1259/bjr.20200055
Clinical Application of Medical Imaging in Neurointerventional Treatment of Brain Diseases
Wu, Q., Wu, Z., Zhang, L., & Wang, H. (2021) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2021.3537
Assessment of cervical spine CT by an image quality audit using qualitative and quantitative methods
Bajwa, H., Sritharan, T., Botha, T., Jackson, P. A., McAnulty, K., Lim, L. J., Tran, P. V., Reeves, S., Biffin, L., & Narayanan, H. (2024) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13791
Radiation exposure during CT procedures in Tanzania
Ngoye, W. M., Ndukeki, M., Muhogora, W. E., Jusabani, A., Ngaile, J. E., Ngoya, P. S., Sungura, R., Ngatunga, C., Hashmi, N., Makungu, H., et al. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad274
Contribución a la dosimetría personal en pruebas médicas radiológicas para entornos regionales
Garcia-Angosto, E. A. (2019) · Digital Repository (Polytechnic University of Cartagena) · doi:10.31428/10317/8631
Effect of contrast enhancement on CT-Scan doses: Based on survey in 2020
Pratama, I. B. G. P. (2022) · AIP conference proceedings · doi:10.1063/5.0127163
Kawvised, S., Ritlumlert, N., Pairodsantikul, P., Piantham, W., Tweeatsani, N., Luangphiphat, W., Sen-ngam, K., Muangsillapasart, V., Sriwiset, S., Saenprom, B., et al. (2023) · Journal of Associated Medical Sciences · doi:10.12982/jams.2023.032
Shamsi, W. M. A. A., & Othman, S. A. (2024) · Semarak Current Biomedical Technology Research Journal · doi:10.37934/scbtrj.1.1.4859b
Revision of Diagnostic Reference Levels in Radiotherapy: A Road to Dose Optimisation
Borrelli, S., Russo, G., Caponigro, S., Minico, D. D., Cavallo, F., Gennuso, N., Romolo, S., Forte, V., Russo, I., & Gentile, P. (2024) · EMJ Radiology · doi:10.33590/emjradiol/wxcd8245
Abdullah, M., Hamza, A. O. M., Barakat, H., & Khider, M. O. (2022) · Journal of Clinical Engineering · doi:10.1097/jce.0000000000000549
Assessment of reference dose levels for nuclear medicine center in Jordan
Alayed, T. (2023) · Journal of medical pharmaceutical and allied sciences · doi:10.55522/jmpas.v12i1.3446
Optimization of radiation dose for optimal image quality in head CT examination
WidyaNurmayanti (2020) · International Journal of Allied Medical Sciences and Clinical Research
On optimal use of radiation in cardiological procedures
Järvinen, J. (2020) · UTUPub (University of Turku)
Dosimetrie diagnostischer Radiopharmaka und Diagnostische Referenzwerte in der Nuklearmedizin
Sattler, B., & Kurth, J. (2023) · Angewandte Nuklearmedizin · doi:10.1055/a-1802-8586
Iimori, T. (2018) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2018_jsrt_74.2.196
Suzuki, C., Yamauchi, Y., Yamamura, D., Takei, Y., & Suzuki, S. (2018) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2018_jsrt_74.12.1434
Hirofuji, Y. (2018) · Japanese Journal of Health Physics · doi:10.5453/jhps.53.230
Moore, C. S., Wood, T. J., Saunderson, J., & Beavis, A. W. (2019) · Journal of Radiological Protection · doi:10.1088/1361-6498/ab3894
Pasieka, E., & Żelechowicz, M. (2017) · Inżynier i Fizyk Medyczny
Mazzi‐Chaves, J. F. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.58.2019.tde-03092019-075502
Abdallah, Y. M. Y., Zaki, W., Ahmadoun, B., & Musa, A. (2020) · Journal of Biomedical Engineering and Medical Imaging · doi:10.14738/jbemi.71.7688
Wells, J. R. (2020) · Wiley eBooks · doi:10.1002/9781118753798.ch4
Zagórska, A., Ivanova, D., Kostova-Lefterova, D. Z., Simeonov, F., Гелев, В., Bogov, I., Mateev, H. F., Alexandrov, A., Jeleva, I., Stoyanov, N., et al. (2020) · Bulgarian Cardiology · doi:10.3897/bgcardio.26.e52193
Velsma, M., & de Waard, I. (2020) · Rivm Repository (Netherlands National Institute for Public Health and the Environment) · doi:10.21945/rivm-2020-0030
Yagui, A., Souza, R. D. C. D., Malthez, A. L. M. C., Barbosa, C. A., Schelin, H. R., & Ferreira, R. R. (2020) · Revista Brasileira de Física Médica · doi:10.29384/rbfm.2020.v14.19849001469
Tacara, S., de Faria, R. A., Coninck, J. C. P., Salvador, G. L. D. O., Schelin, H. R., & Nakano, I. T. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa220
ESTIMATION OF RADIATION DOSAGE FOR TRAUMATIC PATIENTS IN MAJMAAH AREA, SAUDI ARABIA
Abdallah, Y. M. Y. (2020) · RAD Conference Proceedings. · doi:10.21175/radproc.2020.31
REDUCING PELVIS RADIOGRAPH EXPOSURE IN CHILDREN USING A DOSE SIMULATION X-RAY RESEARCH SOFTWARE
Boënnec, R., Dujardin, P., Meunier, B., Rafin, J.-M., Sirinelli, D., Brunereau, L., & Morel, B. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab083
Legal basic and aspects of regulation of the diagnostic reference level (DRL) in Indonesia
Sudradjat, S., & Rusmanto, R. (2021) · AIP conference proceedings · doi:10.1063/5.0058918
BAPETEN challenge for the development of the Indonesian diagnostic reference level (I-DRL)
Iswandarini, I., & Kunarsih, E. (2021) · AIP conference proceedings · doi:10.1063/5.0058874
Erem, G., Bugeza, S., Ameda, F., Otike, C., Olwit, W. K., Mubuuke, A. G., Scandhorf, C., Kisolo, A., & Kawooya, M. G. (2021) · Cogent Medicine · doi:10.1080/2331205x.2021.1975382
Miranda, P. J., Vano, E., Ubeda, C., Figueroa, X., Doggenweiller, P., de Oliveira, M. V. L., & Dalmazzo, D. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab182
Rojo, M., Hamard, A., Serrand, C., de Forges, H., Bérégi, J.-P., Greffier, J., & Frandon, J. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-744
Image properly: Diagnostic reference levels and optimization in oral and maxillofacial radiology
Geist, J. R. (2022) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2021.12.131
STATISTICAL MODELING OF GLANDULARITY FROM MAMMOGRAPHY IMAGES
Castrillón, C. O., & Puerta, J. A. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab179
Vajuhudeen, Z., Moore, C., & Karuppannan, J. K. (2020) · Radiopaedia.org · doi:10.53347/rid-80057
Kobayashi, Y., Kobayashi, M., Kanamori, D., Fujii, N., Kataoka, Y., Satoh, K., Sano, Y., Yoshioka, S., Tateya, I., Toyama, H., et al. (2020) · Research Square · doi:10.21203/rs.3.rs-37116/v1
Development and Validation of Dose Management Software in IVR Utilizing Radiation Information System
Mori, K., Tsuchida, T., & Sekiguchi, R. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1254
Clinical Question Influence on Radiation Dose of Cardiac CT Scan in Children
Adla, T., Kočí, M., Suchánek, V., Šalagovičová, Z., Polovinčák, M., Mikšík, L., Janoušek, J., & Roček, M. (2022) · Children · doi:10.3390/children9081172
Evaluation of the Accuracy of the Displayed Average Glandular Dose in Mammography
Kitano, M., Tokorodani, R., Yamada, Y., & Muto, H. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1292
Tsunou, K., & Ota, S. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1259
Accuracy Evaluation of Air Kerma-area Product of Over-couch-type X-ray Fluoroscopic System
Segawa, K., Yoshikawa, R., Noto, K., Matsubara, K., & Matsuura, Y. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1278
DRLs and Dose Management System
Nagatsuka, S. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-2113
Historical diagnostic guidance level by regulatory bodies in Indonesian
Sudradjat, S., & Rusmanto, R. (2022) · AIP conference proceedings · doi:10.1063/5.0127336
Zurihanaz, A. A., & Noor, N. M. (2023) · Asian Journal Of Medical Technology · doi:10.32896/ajmedtech.v3n1.37-46
Berny, L., Greffier, J., Serrand, C., Dabli, D., Oliveira, F. D., de Forges, H., Bérégi, J.-P., & Frandon, J. (2023) · Research in Diagnostic and Interventional Imaging · doi:10.1016/j.redii.2023.100025
Strahlenschutz in der Gefäßchirurgie
Calo, P., Dischinger, J., & Görtz, H. (2023) · Gefässchirurgie · doi:10.1007/s00772-023-00980-y
Sáenz-Rosales, O., Gutiérrez, F. S., Salvador-Hernández, L., & Chaves, M. G. (2023) · Revista Ciencia y Salud Integrando conocimientos · doi:10.34192/cienciaysalud.v7i1.571
Assessment of models of diagnostic reference levels for children on radiography
Shatskiy, I. G., Gryaznov, A. Y., & Potrakhov, Y. N. (2023) · AIP conference proceedings · doi:10.1063/5.0134774
Diartama, A. A. A., Lobang, V. J., Wirajaya, I. W. A., & Pratista, I. M. S. (2023) · JURNAL ILMU KEDOKTERAN DAN KESEHATAN · doi:10.33024/jikk.v10i4.9607
Doyle, E., Dimmock, M., Lee, K. L., Thomas, P., & Bassed, R. (2023) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.717
Radiation risk communication in mammography
Igarashi, T. (2023) · Nihon Nyugan Kenshin Gakkaishi (Journal of Japan Association of Breast Cancer Screening) · doi:10.3804/jjabcs.32.179
Overview of Japan DRLs 2020 and application of DRLs in Breast Cancer Screening
Negishi, T. (2023) · Nihon Nyugan Kenshin Gakkaishi (Journal of Japan Association of Breast Cancer Screening) · doi:10.3804/jjabcs.32.165
Pong-Inwong, V., Kirisattayakul, W., Dawong, S., Jitvikham, A., Ahooja, A., Pattum, P., Karawek, R., Sudjai, W., & Rungpin, N. (2023) · Journal of Health Science and Medical Research · doi:10.31584/jhsmr.2023996
Zaštita od zračenja kod MSCT pretraga: Sustavni pregled literature
Čanaki, F., & Dolić, K. (2023) · Radiološki vjesnik · doi:10.55378/rv.47.2.6
Radiation Exposure in Breast Imaging and Radiation Therapy
Matsubara, K. (2023) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2023-2278
Gizewski, E. R., Verius, M., Rehani, M. M., & Jaschke, W. R. (2023) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-023-03604-w
Self-citationZarghani, H., Pandesh, S., & Jabbari, M. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad300
Protección radiológica en endoscopia
Tchekmedyian, A. J., Dumonceau, J., Espizua, F. J. R., Bicalho, L. A. F., & Vano, E. (2023) · Revista de Gastroenterología del Perú · doi:10.47892/rgp.2023.434.1627
Typical Values in Digital Mammography Within the Framework of Diagnostic Reference Levels
Real, J. V., & Malthez, A. L. M. C. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49410-9_40
Krmek, N., Környei, L., Kralik, I., Delić-Brkljačić, D., Milošević, M., Rode, M., Kocsis, F., & Radeljić, V. (2024) · Pediatric Cardiology · doi:10.1007/s00246-024-03428-6
Peak skin dose in patients undergoing coronary intervention: a review
Ramos-Avasola, S., Karstulovic, C., Clavijo-Clavijo, M., Carvajal-Navarro, C., Gutiérrez-Herrera, Í., Piñeiro-Clavijo, C., Rojas-Calderón, M., Uberuaga-Payacán, D., Allende, F., Sierra, D., et al. (2024) · Revista de Fomento Social · doi:10.24875/rchrad.23000013
Bartal, G., & Vano, E. (2024) · Springer eBooks · doi:10.1007/978-3-031-52546-9_2
Takizawa, T., Sekimoto, M., & Kodama, N. (2024) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2024-1448
Hourdakis, C. J., Vogiatzi, S., Kalathaki, M., Tritakis, P., Simantirakis, G., Pafilis, C., Manousaridis, G., Thrapsanioti, Z., Liotsou, V., Nikolaou, M., et al. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.103412
Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand
Pairodsantikul, P., Wongsa, P., Wongkri, C., Burasothikul, P., Jantarato, A., & Chotipanich, C. (2024) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.124.267576
Jannah, R., Munir, R., & Putri, E. R. (2023) · Progressive Physics Journal · doi:10.30872/ppj.v4i2.1028
National-level Dental Radiological Dose Management
Kang, J.-H. (2024) · 대한치과의사협회지 · doi:10.22974/jkda.2024.62.2.006
Thongkum, V., Sermsuk, P., Teerakeerayut, A., & Jumpee, C. (2024) · Journal of Associated Medical Sciences · doi:10.12982/jams.2024.054
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL
Alvarez, M., Guassu, R. A. C., Rosa, A. A., Sousa, R. R., & de Pina, D. R. (2025) · Radioprotection · doi:10.1051/radiopro/2024031
Ferreira, K. C., Denyak, V., Nunes, M. C. D. A., Nunes, G. S., Real, J. V., & Filipov, D. (2024) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2024.2455
Hikmah, I., Hariyanto, A. P., & Zen, N. A. (2024) · AIP conference proceedings · doi:10.1063/5.0228328
Multicenter Survey on Phantom Entrance Surface Air Kerma of Angiography and IVR in Japan
Hasegawa, R., Noguchi, K., Takeda, K., Sakiyama, K., Sato, M., Maekawa, K., Hayashi, T., Tajima, O., Sakamoto, H., Sato, H., et al. (2024) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2024-1483
“Typical Values“ of Activities Administered to Pedriatics Patients in Renal Exams with 99mTc-DTPA
Oliveira, C. M., Oliveira, L. F., & Leite, M. F. L. (2024) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2024.2461
Musa, N. A. S., & MSc. Siham M. H (2024) · Journal of medical and dental science research. · doi:10.35629/076x-11105963
Chaychid, N., Bunta, K., Awikunprasert, P., Sangsuwan, K., Wuttanatum, C., & Duksukkeaw, N. (2024) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2024.101783
Dynamic Distribution of Scattered Radiation in a CT Room, Utilizing a Semiconductor Survey MeterPreprint
Kobayashi, M., Suzuki, J., Nishihara, Y., Haba, T., Yuta, M., Asada, Y., & Kobayashi, S. (2024) · Research Square · doi:10.21203/rs.3.rs-5101243/v1
Jain, M., Sharma, R. C., Joan, M., Chougule, A., & Jangir, R. K. (2024) · GFNPSS-International Journal of Multidisciplinary Research · doi:10.46376/ijmr/5.5.2024.2592-2599
National Survey on Procedure Dose of Endovascular Treatment for Lower Extremity Artery Disease
Ishibashi, T., Takao, Y., Ishibashi, T., Sakai, Y., Fujimoto, Y., Osawa, M., Shinobu, A., Hasegawa, K., & Sakamoto, H. (2024) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.25-1521
Acosta, J., Javiera Sanguesa, M., Pablo Soffia, S., & Daniella Fabri, G. (2024) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2024.2445
Werncke, T., Becker, L. S., Maschke, S. K., Brüsch, I., Rumpel, R., Wacker, F. K., & Meyer, B. (2024) · Investigative Radiology · doi:10.1097/rli.0000000000001136
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.