ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 395
Hauptmann, M., Byrnes, G., Cardis, E., Bernier, M.-O., Blettner, M., Dabin, J., Engels, H., Istad, T. S., Johansen, C., Kaijser, M., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00655-6 · Cited by 273
Smith-Bindman, R., Wang, Y., Chu, P., Chung, R., Einstein, A. J., Balcombe, J., Cocker, M., Das, M., Delman, B. N., Flynn, M., et al. (2019) · BMJ · doi:10.1136/bmj.k4931 · Cited by 242
Schegerer, A., Loose, R., Heuser, L. J., & Brix, G. (2019) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-0824-7603 · Cited by 173
Modarai, B., Haulon, S., Ainsbury, E. A., Böckler, D., Vañó-Carruana, E., Dawson, J. A., Farber, M. A., HERZEELE, I. V., Hertault, A., van Herwaarden, J. A., et al. (2022) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2022.09.005 · Cited by 164
Paulo, G., Damilakis, J. E., Tsapaki, V., Schegerer, A., Repussard, J., Jaschke, W. R., Frija, G. G., European Society of Radiology, Hierath, M., & Clark, J. M. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00899-y · Cited by 126
Optimizing radiation safety in dentistry
Benavides, E., Krecioch, J. R., Connolly, R. T., Allareddy, T. V., Buchanan, A., Spelic, D. C., O’Brien, K. K., Keels, M. A., Mascarenhas, A. K., Duong, M., et al. (2024) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2023.12.002 · Cited by 123
Tsapaki, V. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.09.015 · Cited by 116
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Pediatric CT Examinations
Kanal, K. M., Butler, P. F., Chatfield, M. B., Wells, J., Samei, E., Simanowith, M., Golden, D., Gress, D. A., Burleson, J., Sensakovic, W. F., et al. (2022) · Radiology · doi:10.1148/radiol.2021211241 · Cited by 101
Areas of research to support the system of radiological protection
Laurier, D., Rühm, W., Paquet, F., Applegate, K. E., Cool, D. A., Clement, C. H., & the International Commission on Radiological Protection (ICRP) (2021) · Radiation and Environmental Biophysics · doi:10.1007/s00411-021-00947-1 · Cited by 91
Tsapaki, V., Damilakis, J. E., Paulo, G., Schegerer, A., Repussard, J., Jaschke, W. R., & Frija, G. G. (2021) · European Radiology · doi:10.1007/s00330-020-07652-5 · Cited by 90
Helliwell, K., Hughes, V. J., Bennion, C. M., & Manning-Stanley, A. S. (2023) · Radiography · doi:10.1016/j.radi.2022.12.007 · Cited by 85
How to establish and use local diagnostic reference levels: an ESR EuroSafe Imaging expert statement
Damilakis, J., Frija, G., Brkljacic, B., Vano, E., Loose, R., Paulo, G., Brat, H., Tsapaki, V., & the European Society of Radiology (2023) · Insights into Imaging · doi:10.1186/s13244-023-01369-x · Cited by 76
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Radiation doses from head, neck, chest and abdominal CT examinations: an institutional dose report
Atlı, E., Uyanık, S. A., Öğüşlü, U., Cenkeri, H. C., Yılmaz, B., & Gümüş, B. (2021) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2020.19560 · Cited by 72
The 2020 national diagnostic reference levels for nuclear medicine in Japan
Abe, K., Hosono, M., Igarashi, T., Iimori, T., Ishiguro, M., Ito, T., Nagahata, T., Tsushima, H., & Watanabe, H. (2020) · Annals of Nuclear Medicine · doi:10.1007/s12149-020-01512-4 · Cited by 72
Establishing the European diagnostic reference levels for interventional cardiology
Siiskonen, T., Ciraj‐Bjelac, O., Dabin, J., Diklić, A., Domienik-Andrzejewska, J., Farah, J., Fernández, J. M., Gallagher, A., Hourdakis, C. J., Jurković, S., et al. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.09.012 · Cited by 69
Matsunaga, Y., Chida, K., Kondo, Y., Kobayashi, K., Kobayashi, M., Minami, K., Suzuki, S., & Asada, Y. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20180290 · Cited by 65
Bos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Medical imaging dose optimisation from ground up: expert opinion of an international summit
Samei, E., Järvinen, H., Kortesniemi, M., Simantirakis, G., Goh, C. X. Y., Wallace, A. B., Vano, E., Bejan, A., Rehani, M. M., & Vassileva, J. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aac575 · Cited by 63
Self-citationAnatomical-guided attention enhances unsupervised PET image denoising performance
Onishi, Y., Hashimoto, F., Ote, K., Ohba, H., Ota, R., Yoshikawa, E., & Ouchi, Y. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102226 · Cited by 62
Tsapaki, V., Balter, S., Cousins, C., Holmberg, O., Miller, D. L., Miranda, P., Rehani, M. M., & Vano, E. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.06.634 · Cited by 61
Self-citationAberle, C., Ryckx, N., Treier, R., & Schindera, S. T. (2019) · European Radiology · doi:10.1007/s00330-019-06485-1 · Cited by 60
Coastal Ocean Observing and Modeling Systems in Brazil: Initiatives and Future Perspectives
Franz, G., Garcia, C. A. E., Pereira, J., Assad, L. P. D. F., Rollnic, M., Garbossa, L. H. P., da Cunha, L. C., Lentini, C. A. D., Nobre, P., Turra, A., et al. (2021) · Frontiers in Marine Science · doi:10.3389/fmars.2021.681619 · Cited by 59
Applegate, K. E., Findlay, Ú., Fraser, L., Kinsella, Y., Ainsbury, E. A., & Bouffler, S. D. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac1c95 · Cited by 58
Developing diagnostic reference levels in Japan
Kanda, R., Akahane, M., Koba, Y., Chang, W., Akahane, K., Okuda, Y., & Hosono, M. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-020-01066-5 · Cited by 56
Brat, H. G., Zanca, F., Montandon, S., Racine, D., Rizk, B., Eric, M., & Fournier, D. (2019) · European Radiology · doi:10.1007/s00330-019-06257-x · Cited by 54
Loose, R. W., Vano, E., Mildenberger, P., Tsapaki, V., Caramella, D., Sjöberg, J., Paulo, G., Torresin, A., Schindera, S., Frija, G., et al. (2021) · European Radiology · doi:10.1007/s00330-020-07290-x · Cited by 53
Geryes, B. H., Hornbeck, A., Jarrige, V., Pierrat, N., Pointe, H. D. L., & Dreuil, S. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.04.004 · Cited by 51
Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors
Vano, E., Frija, G. G., Loose, R., Paulo, G., EFSTATHOPOULOS, E. P., Granata, C., Andersson, J., & the European Society of Radiology (ESR) (2021) · Insights into Imaging · doi:10.1186/s13244-021-01041-2 · Cited by 51
Radiation dose monitoring in computed tomography: Status, options and limitations
Tsalafoutas, I. A., Kharita, M. H., AlNaemi, H., & Kalra, M. K. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.08.020 · Cited by 51
Expanding the Concept of Diagnostic Reference Levels to Noise and Dose Reference Levels in CT
Ria, F., Davis, J. T., Solomon, J., Wilson, J. M., Smith, T. B., Frush, D. P., & Samei, E. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.21030 · Cited by 50
Roch, P., Célier, D., Dessaud, C., Étard, C., & Rehani, M. M. (2019) · European Radiology · doi:10.1007/s00330-019-06422-2 · Cited by 49
Self-citationJärvinen, H., Vassileva, J., Samei, E., Wallace, A., Vano, E., & Rehani, M. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.3.031214 · Cited by 45
Self-citationJeukens, C. R. L. P. N., Kütterer, G., Kicken, P. J. H., Frantzen, M. J., van Engelshoven, J. M. A., Wildberger, J. E., & Kemerink, G. J. (2020) · Insights into Imaging · doi:10.1186/s13244-019-0828-1 · Cited by 43
Shahrokhi, A., & Kovács, T. (2021) · Environmental Sciences Europe · doi:10.1186/s12302-021-00507-w · Cited by 42
An international survey of imaging practices in radiotherapy
Martin, C. J., Kron, T., Vassileva, J., Wood, T. J., Joyce, C., Ung, N. M., Small, W. C., Gros, S., Roussakis, Y., Plazas, M. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.09.004 · Cited by 41
Self-citationA Nordic survey of CT doses in hybrid PET/CT and SPECT/CT examinations
Bebbington, N. A., Haddock, B., Bertilsson, H., Hippeläinen, E. T., Husby, E., Tunninen, V., & Söderberg, M. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0266-7 · Cited by 40
Schegerer, A., Frija, G. G., Paulo, G., Jaschke, W. R., Tsapaki, V., Repussard, J., & Damilakis, J. E. (2021) · European Radiology · doi:10.1007/s00330-021-08029-y · Cited by 40
Clinical application of radiation dose reduction for head and neck CT
Yabuuchi, H., Kamitani, T., Sagiyama, K., Yamasaki, Y., Matsuura, Y., Hino, T., Tsutsui, S., Kondo, M., Shirasaka, T., & Honda, H. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.08.021 · Cited by 40
Dose reference levels and clinical determinants in stroke neuroradiology interventions
Farah, J., Rouchaud, A., Henry, T., Regen, C., Mihalea, C., Moret, J., & Spelle, L. (2018) · European Radiology · doi:10.1007/s00330-018-5593-x · Cited by 39
Abuhaimed, A., & Martin, C. J. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.05.001 · Cited by 39
Self-citationKorean Society of Nuclear Medicine Diagnostic Reference Level Task Force, Song, H., Na, M. H., Kim, J., Cho, S., Park, J. K., & Kang, K. W. (2019) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-019-00585-y · Cited by 38
Self-citationon behalf of the RADON Investigators, Guenego, A., Mosimann, P. J., Pereira, V. M., Nicholson, P. J., Zuber, K., Lotterie, J. A., Dobrocky, T., Marcellus, D. G., Olivot, J., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06062-6 · Cited by 38
Wood, T. J., Davis, A. T., Earley, J., Edyvean, S., Findlay, Ú., Lindsay, R., Nisbet, A., Palmer, A. L., Plaistow, R., & Williams, M. J. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aacc87 · Cited by 38
Forbrig, R., Özpeynirci, Y., Grasser, M., Dorn, F., Liebig, T., & Trumm, C. G. (2020) · European Radiology · doi:10.1007/s00330-020-06777-x · Cited by 38
Abuzaid, M., Elshami, W., Tekin, H. O., Ghonim, H., Shawki, M., & Salama, D. H. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00891-6 · Cited by 37
Almén, A., Guðjónsdóttir, J., Heimland, N., Højgaard, B., Waltenburg, H., & Widmark, A. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210700 · Cited by 37
Célier, D., Roch, P., Étard, C., Pointe, H. D. L., & Brisse, H. J. (2019) · European Radiology · doi:10.1007/s00330-019-06405-3 · Cited by 37
Jaschke, W. R., Bartal, G., Martin, C. J., & Vano, E. (2020) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02517-2 · Cited by 37
Self-citationCone-Beam Computed Tomography in Endodontics—State of the Art
Mazzi‐Chaves, J. F., de Camargo, R. V., Borges, A. F., Silva, R. G., Pauwels, R., Silva‐Sousa, Y. T. C., & Sousa‐Neto, M. D. (2021) · Current Oral Health Reports · doi:10.1007/s40496-021-00292-8 · Cited by 37
Acton, H. J., James, K., Kavanagh, R. G., O’Tuathaigh, C. M. P., Moloney, D., Wyse, G. M., Fanning, N. F., Maher, M. M., & O’Connor, O. J. (2018) · European Radiology · doi:10.1007/s00330-018-5405-3 · Cited by 36
Hayashi, S., Takenaka, M., Hosono, M., Kogure, H., Hasatani, K., Suda, T., Maruyama, H., Matsunaga, K., Ihara, H., Yoshio, T., et al. (2022) · The Lancet Regional Health - Western Pacific · doi:10.1016/j.lanwpc.2021.100376 · Cited by 36
INSTITUTIONAL BREAST DOSES IN DIGITAL MAMMOGRAPHY
Lekatou, A. N., Metaxas, V. I., Messaris, G. A. T., Antzele, P., Tzavellas, G., & Panayiotakis, G. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz005 · Cited by 35
Garba, I., Zarb, F. L., McEntee, M. F., & Fabri, S. G. (2020) · Radiography · doi:10.1016/j.radi.2020.08.011 · Cited by 34
Suliman, I. I. (2019) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-019-00199-y · Cited by 34
Review of National Diagnostic Reference Levels for Interventional Procedures
Lee, M. Y., Kwon, J., Ryu, G. W., Kim, K. H., Nam, H. W., & Kim, K. P. (2019) · Progress in Medical Physics · doi:10.14316/pmp.2019.30.4.75 · Cited by 34
Gershan, V., Homayounieh, F., Singh, R., Avramova-Cholakova, S., Faj, D., Georgiev, E., Girjoaba, O., Gricienė, B., Gruppetta, E., Šimonji, D. H., et al. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108923 · Cited by 34
The growing potential of diagnostic reference levels as a dynamic tool for dose optimization
Damilakis, J. E., & Vassileva, J. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.018 · Cited by 33
Radium dial workers: back to the future
Martinez, N. E., Jokisch, D. W., Dauer, L. T., Eckerman, K. F., Goans, R. E., Brockman, J. D., Tolmachev, S. Y., Avtandilashvili, M., Mumma, M. T., Boice, J. D., et al. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1917785 · Cited by 33
Ihn, Y. K., Kim, B., Jeong, H. W., Suh, S. H., Won, Y. D., Lee, Y., Kim, D. J., Jeon, P., Ryu, C., Suh, S., et al. (2021) · Neurointervention · doi:10.5469/neuroint.2021.00437 · Cited by 33
Deleu, M., Dagassan, D., Berg, I., Bize, J., Dula, K., Lenoir, V., OTT, B. B., Ott, J. G., Verdun, F. R., Weber, R. J., et al. (2020) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20190468 · Cited by 33
Botwe, B. O., Schandorf, C., Inkoom, S., Faanu, A., Rolstadaas, L., & Goa, P. E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.012 · Cited by 32
Li, X., Hirsch, J. A., Rehani, M. M., Yang, K., & Liu, B. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.19.21804 · Cited by 32
Self-citationRacine, D., Ryckx, N., Ba, A. H., Becce, F., Viry, A., Verdun, F. R., & Schmidt, S. (2018) · European Radiology · doi:10.1007/s00330-018-5518-8 · Cited by 32
Radiation Dose of Patients in Fluoroscopically Guided Interventions: an Update
Paulo, G., Bartal, G., & Vano, E. (2020) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02667-3 · Cited by 32
Moghadam, N., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109871 · Cited by 32
Self-citationSummary of the 2021 ICRP workshop on the future of radiological protection
Rühm, W., Clement, C. H., Cool, D. A., Laurier, D., Bochud, F. O., Applegate, K. E., Schneider, T., Bouffler, S. D., Cho, K.-W., Hirth, G., et al. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac670e · Cited by 32
Validation of algorithmic CT image quality metrics with preferences of radiologists
Cheng, Y. H., Abadi, E., Smith, T. B., Ria, F., Meyer, M., Marin, D., & Samei, E. (2019) · Medical Physics · doi:10.1002/mp.13795 · Cited by 32
Establishing local diagnostic reference levels for adult computed tomography in Morocco
Mansouri, M. E., Talbi, M., Choukri, A., Nhila, O., & Aabid, M. (2022) · Radioprotection · doi:10.1051/radiopro/2021035 · Cited by 31
Determining and updating PET/CT and SPECT/CT diagnostic reference levels: A systematic review
Alkhybari, E. M., McEntee, M. F., Brennan, P., Willowson, K. P., Hogg, P., & Kench, P. L. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy113 · Cited by 31
Salimi, Y., Shiri, I., Akhavanallaf, A., Mansouri, Z., Sanaat, A., Pakbin, M., Ghasemian, M., Arabi, H., & Zaidi, H. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110602 · Cited by 31
Ploussi, A., Syrgiamiotis, V., Makri, T. K., Hatzigiorgi, C., & EFSTATHOPOULOS, E. P. (2020) · British Journal of Radiology · doi:10.1259/bjr.20190358 · Cited by 31
Vano, E., Fernández, J. M., Ten, J. I., & Sánchez, R. M. (2022) · British Journal of Radiology · doi:10.1259/bjr.20211340 · Cited by 31
Ubeda, C., Vano, E., Pérez, M. D. R., Jiménez, P., Ramirez, R., Nader, A., Miranda, P., Azcurra, P., Damsky, J., Capdevila, S., et al. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac87b7 · Cited by 31
Proposed diagnostic reference levels for general radiography and mammography in Japan
Asada, Y., Kondo, Y., Kobayashi, M., Kobayashi, K., Ichikawa, T., & Matsunaga, Y. (2020) · Journal of Radiological Protection · doi:10.1088/1361-6498/aba083 · Cited by 30
Diagnostic reference levels for paediatric CT in Jordan
Rawashdeh, M., Abdelrahman, M., Zaitoun, M., Saade, C., Alewaidat, H., & McEntee, M. F. (2019) · Journal of Radiological Protection · doi:10.1088/1361-6498/ab3ee2 · Cited by 30
Earl, V. J., Potter, A. O. G., & Perdomo, A. A. (2022) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.632 · Cited by 29
Rusandu, A., Ødegård, A., Engh, G., & Olerud, H. M. (2018) · Radiography · doi:10.1016/j.radi.2018.10.004 · Cited by 29
Sensitivity and latency of ionising radiation-induced cataract
Ainsbury, E. A., & Barnard, S. G. R. (2021) · Experimental Eye Research · doi:10.1016/j.exer.2021.108772 · Cited by 29
Zalokar, N., Marciuš, V. Ž., & Mekiš, N. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108979 · Cited by 29
Kataria, B., Althén, J. N., Smedby, Ö., Persson, A., Sökjer, H., & Sandborg, M. P. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.108703 · Cited by 29
Assessment of diagnostic reference levels awareness and knowledge amongst CT radiographers
Abdulkadir, M. K., Piersson, A. D., Musa, G. M., Audu, S. A., Abubakar, A. M., Muftaudeen, B., & Umana, J. E. (2021) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-021-00444-x · Cited by 28
Inoue, Y. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.11.009 · Cited by 28
Takenaka, M., Hosono, M., Hayashi, S., Nishida, T., & Kudo, M. (2022) · Digestive Endoscopy · doi:10.1111/den.14208 · Cited by 28
Sánchez, R. M., Vano, E., Soto, J. M. F., Ten, J. I., Escaned, J., Delgado, C., del Blanco, B. G., Magariño, F. C., Fernández, J. F. D., Martinez-Luna, R. J., et al. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.01.014 · Cited by 28
Occupational and patient doses for interventional radiology integrated into a dose management system
Vano, E., Fernández, J. M., Ten, J. I., & Sánchez, R. M. (2022) · British Journal of Radiology · doi:10.1259/bjr.20220607 · Cited by 28
National diagnostic reference levels: What they are, why we need them and what’s next
Thomas, P. (2022) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13375 · Cited by 27
Wagner, F., Bize, J., Racine, D., Coultre, R. L., Verdun, F. R., Trueb, P. R., & Treier, R. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aac69c · Cited by 27
Deep learning-based segmentation of ultra-low-dose CT images using an optimized nnU-Net model
Salimi, Y., Mansouri, Z., Sun, C., Sanaat, A., Yazdanpanah, M., Shooli, H., Nkoulou, R. N., Boudabbous, S., & Zaidi, H. (2025) · La radiologia medica · doi:10.1007/s11547-025-01989-x · Cited by 27
Dosimetry on first clinical dark‐field chest radiography
Frank, M., Urban, T., Willer, K., Noichl, W., Marco, F. D., Schick, R. C., Gleich, B., Schegerer, A., Lechel, U., Meyer, P., et al. (2021) · Medical Physics · doi:10.1002/mp.15132 · Cited by 27
Radiological protection of the patient in veterinary medicine and the role of ICRP
Pentreath, R. J., Applegate, K. E., Higley, K. A., Peremans, K., Natsuhori, M., Randall, E. K., & Gambino, J. (2020) · Annals of the ICRP · doi:10.1177/0146645320946619 · Cited by 27
Schmitz, D., Vogl, T. J., Nour-Eldin, N.-E. A., Radeleff, B. A., Kröger, J., Mahnken, A. H., Ittrich, H., Gehl, H., Plessow, B., Böttcher, J., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06208-6 · Cited by 27
Hirschfeld, C. B., Mercuri, M., Pascual, T. N. B., Karthikeyan, G., Vitola, J. V., Mahmarian, J. J., Better, N., Bouyoucef, S. E., Bom, H. H.-S., Lele, V. R., et al. (2021) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2020.11.011 · Cited by 27
Self-citationComparison of 12 surrogates to characterize CT radiation risk across a clinical population
Ria, F., Fu, W., Hoye, J., Segars, W. P., Kapadia, A., & Samei, E. (2021) · European Radiology · doi:10.1007/s00330-021-07753-9 · Cited by 27
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00838-x · Cited by 26
“It was intended to be a simple test to identify situations where the patient radiation dose levels were unusually high [8].”
BackgroundPatient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
Gao, Y., Mahmood, U. A., Liu, T., Quinn, B. M., Gollub, M. J., Xu, X. G., & Dauer, L. T. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.19.21197 · Cited by 26
AlNaemi, H., Tsapaki, V., Omar, A., Alkuwari, M., Alobadli, A. M., AlKhazzam, S., Aly, A., & Kharita, M. H. (2020) · European Journal of Radiology Open · doi:10.1016/j.ejro.2020.100282 · Cited by 26
Takenaka, M., Hosono, M., Hayashi, S., Nishida, T., & Kudo, M. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210399 · Cited by 26
Diagnostic reference levels in digital mammography: a systematic review
Liu, Q., Suleiman, M. E., McEntee, M. F., & Soh, B. P. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac4214 · Cited by 26
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.