ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 801–900 of 1,000
Hegazi, T. M., Al-Sharydah, A. M., Alfawaz, I., Al-Muhanna, A., & Faisal, S. Y. (2023) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s389960 · Cited by 1
Gumede, L., & Badriparsad, N. (2023) · Springer eBooks · doi:10.1007/978-981-19-9346-6_3 · Cited by 1
Lackay, O., Horn-Lodewyk, J., & Muller, H. (2026) · Health Science Reports · doi:10.1002/hsr2.72185 · Cited by 1
Almén, A. (2026) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf106 · Cited by 1
Vano, E., Fernández, J. M., Sánchez, R. M., & Morón, J. I. T. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad53d8 · Cited by 1
Lopes, R., & Santos, J. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae200 · Cited by 1
Sazgary, L., Samara, E. T., Stüssi, A., Saltybaeva, N., Gückenberger, M., Ruschitzka, F. T., Wölber, T., Molitor, N., Guan, F., Suna, G., et al. (2025) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2025.04.003 · Cited by 1
Samara, E. T., Sazgary, L., Stüssi, A., Saltybaeva, N., Gückenberger, M., Ruschitzka, F. T., Wolber, T., Molitor, N., Höfer, D., Guan, F., et al. (2025) · Swiss Medical Weekly · doi:10.57187/s.4053 · Cited by 1
Mansour, H. H., Karim, N. K. A., Osman, N. D., Hami, R. B., & Alajerami, Y. S. M. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113375 · Cited by 1
Gala, H. D. L. H., Giussani, A., Schlattl, H., Trinkl, S., & Brix, G. (2026) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2790-4742 · Cited by 1
Sowa, M. S., Sowa, J., & Budzanowski, M. (2026) · Biomedicines · doi:10.3390/biomedicines14061251 · Cited by 1
Paixão, L., Mota, L. G., de Freitas, S. S., & Dumont, S. M. (2025) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.125.270129 · Cited by 1
Développement d'un système dosimétrique pour la radiologie interventionnelle
Deschler, T. W. (2018) · theses.fr (ABES) · doi:10.70675/9c1217caz04bbz43f9zaad3zf06bf3a3efb1 · Cited by 1
Radiation Dose Assessment In Pediatric Chest Ct Protocols With Emphasis On Ctdivol And Dlp
Singh, R., Kumar, A., Johri, A., Katiyar, D., Yadav, S., Nandhini, N., & Gangwar, R. (2025) · Journal of Carcinogenesis · doi:10.64149/j.carcinog.24.2s.431-436 · Cited by 1
Karout, L., AlKhazzam, S., Kharita, M. H., Dervis, M., Saboo, Y. S., Sikka, T., Karout, S., Burade, A., Yametti, J. E. C., Kaviani, P., et al. (2026) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2026.102557 · Cited by 1
Ghazizadeh, M., Deevband, M. R., Kardan, M. R., & Tavakoli, M. (2025) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf030 · Cited by 1
Computed Tomography Dose Level in Selected Five Principal Hospitals in Ethiopia
Kinfe, G. K., & Wores, B. T. (2023) · Ethiopian Journal of Health Sciences · doi:10.4314/ejhs.v33i6.11 · Cited by 1
Esien-umo, E., Egong, A. E., Ikamaise, V. C., Ishiekwen, C. A., Eduwem, D., Mark, G. A., Obinna, S. O., Ekpo, E. U., & Egbe, N. (2026) · Global Journal of Pure and Applied Sciences · doi:10.4314/gjpas.v32i3.6 · Cited by 1
Al-Horani, Q., Alkhybari, E., Rawashdeh, M., Latiff, R. A., Sabarudin, A., Al-Ibraheem, A., & Mohamad, M. (2023) · Research Square · doi:10.21203/rs.3.rs-3049856/v1 · Cited by 1
Druzhinina, P. S., Pozdnyakov, A. V., Kapyrina, Y. N., Ivanov, D. O., Petrenko, Y. V., & Пузырев, В. Г. (2021) · Radiacionnaâ gigiena · doi:10.21514/1998-426x-2021-14-3-91-100 · Cited by 1
Diagnostic reference levels for pediatric fluoroscopy procedures: A systematic review
Aloufi, K. M. (2026) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2026.112465 · Cited by 1
Recent Topics in Epidemiology and Risk Estimation for Medical Exposures to Ionizing Radiation
Hamada, N., & Yoshinaga, S. (2018) · Japanese Journal of Health Physics · doi:10.5453/jhps.53.136 · Cited by 1
Nuclear Medicine Dosimetry in Paediatric Population
Verganelakis, D. A., & Lyra-Georgosopoulou, M. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.105346 · Cited by 1
Overview of Diagnostic Reference Levels in Japan: ─Current Situations and Future Prospects─
Igarashi, T. (2019) · Japanese Journal of Health Physics · doi:10.5453/jhps.54.13 · Cited by 1
Determination of reference levels of ionizing radiation in interventional radiology
", S. B.-F. H. C. I. O. T. C. O. M., Sorokin, V. G., Ryzhov, S. A., Omelchenko, A. V., & Gromov, D. G. (2020) · Radiation and Risk Bulletin of the National Radiation and Epidemiological Registry · doi:10.21870/0131-3878-2020-29-3-88-96 · Cited by 1
Estratégias de Otimização da Dose de Radiação em Angiotomografia Abdominal
de Assunção, M. S. C., Dias, T. S., de Azambuja, R. L., Medeiros, R. B., & Freitas, M. B. D. (2021) · Revista Brasileira de Física Médica · doi:10.29384/rbfm.2021.v15.19849001631 · Cited by 1
Abubakar, U., Ahmad, M. M., Al-Amin, U. A., Sadiq, A. A., Mohammed, A., Mohammed, N. H., Izge, I. Y., Sidi, M., & Mohammed, A. (2023) · African Scientific Reports · doi:10.46481/asr.2023.2.1.85 · Cited by 1
Assessment of radiation doses for common radiographic examinations: an institutional dose survey
Kwok, Y. M., Toh, H. G., Lee, L., Chea, Y. W., & Chan, L. L. (2023) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2022-099 · Cited by 1
Lakmal, T., Lamabadusuriya, M., Satharasinghe, D., Thilakshika, R., Pallewatte, A. S., & Jeyasugiththan, J. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111354 · Cited by 1
Questionnaire Survey on IVR Dose Management in Tokai Region
Osawa, M., Nagata, A., Saijou, T., Yamada, T., Sugimoto, N., Tokudome, A., Suzuki, K., & Sakamoto, H. (2023) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2024-1342 · Cited by 1
Uniyal, S. C., Singh, V., Rawat, A., Gururani, K., & Belwal, C. M. (2024) · Radiological Physics and Technology · doi:10.1007/s12194-024-00805-x · Cited by 1
Shirazu, I., Hasford, F., Azantillow, N., Sackey, T. A., Nunoo, G., Dzefi‐Tettey, K., Mensah, Y., Amponsah, B. A., Tagoe, S. N. A., Esposito, M., et al. (2024) · Health and Technology · doi:10.1007/s12553-024-00896-x · Cited by 1
Self-citationTesfaw, A. F., Dellie, S. T., Legesse, T. K., Gorfu, Y., & Seid, A. N. (2024) · SAGE Open Medicine · doi:10.1177/20503121241266323 · Cited by 1
Dwivedi, P., Jha, A. K., Mithun, S., Sawant, V., Vajarkar, V., Chauhan, M. K. H., Choudhury, S., & Rangarajan, V. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae179 · Cited by 1
Research Report on the Consistency of Radiation Dose Structured Report (RDSR)
Nakada, Y., Hayashi, H., Okuda, Y., Aita, M., Katsunuma, Y., Kawamata, M., Shibata, H., 柘植, 達., Furuta, K., Miyanishi, T., et al. (2024) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2024-1463 · Cited by 1
Typical local DRL values for interventional cardiology procedures
Ghosn, R., Massoud, C., Ghanem, G., Soueidy, M., Khoury, D. E., & Rizk, C. (2025) · Radioprotection · doi:10.1051/radiopro/2024053 · Cited by 1
Mahmoud, A. M. (2024) · Cureus · doi:10.7759/cureus.75135 · Cited by 1
Patients dose and risk assessment in fluoroscopically guided interventional procedures in Ghana
Shirazu, I., Hasford, F., Azantillow, N., Sackey, T. A., Nunoo, G., Dzefi‐Tettey, K., Mensah, Y., Sarkodie, B. D., Amponsah, B. A., Tagoe, S. N. A., et al. (2024) · Health and Technology · doi:10.1007/s12553-024-00919-7 · Cited by 1
Self-citationEvaluating the functionality of x-ray angiography systems based on DICOM structured reports
Omar, A., Hulthén, M., & Karambatsakidou, A. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.104878 · Cited by 1
Assessment of surface contamination of low-dose radioactive iodine (131I) treatment container
Ryu, C.-J. (2024) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001939 · Cited by 1
León, M. I., Quispe, B., Gutiérrez, L., Pena, J., Waldo-Benítez, G., Cerón, P. V., Hernández, M. A., Vega, H. R., Montes, E., Reyes, U., et al. (2024) · International Journal of Radiation Research · doi:10.61186/ijrr.22.4.853 · Cited by 1
Optimization of Conventional Radiology Doses During Adults Chests Examinations
Alain, O., Oka, N. G. L., Konaté, I., Koua, A. A., Gerald, D., & Firmin, G. (2024) · American Journal of Physics and Applications · doi:10.11648/j.ajpa.20241206.12 · Cited by 1
Alhujaili, S. F., Sulieman, A., Alrowaili, Z. A., Alshabibi, A. S. A., Alafer, F., Alqahtani, M. M., Salah, H., Alanezi, A. J., AlRashidi, A. S., & Abuzaid, M. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.111695 · Cited by 1
Barbosa, N., Pareja, A. M., & Villamil, K. (2023) · Revista colombiana de radiología · doi:10.53903/01212095.301 · Cited by 1
Fraser, L., Parkar, N., Powell, A., & Richardson, M. (2025) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001953 · Cited by 1
Yagui, A., Schelin, H. R., Mello, R. G., Vosiak, P., Vargas, B., dos Santos, J. M., Legnani, A., Denyak, V., Filipov, D., Paschuk, S. A., et al. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.112732 · Cited by 1
Skovorodko, K., Jreije, A., Andriulevičiūtė, I., Krynke, L., & Gricienė, B. (2024) · Medical physics – the current status problems the way of development Innovation technologies · doi:10.17721/3041-1491/2024.11-11 · Cited by 1
Gazdag-Hegyesi, S., Gáldi, Á., Koszta, E., Stelczer, G., Szegedi, D., Major, T., & Pesznyák, C. (2025) · Reports of Practical Oncology & Radiotherapy · doi:10.5603/rpor.104733 · Cited by 1
Sakai, Y., Ishibashi, T., Takao, Y., Ishibashi, T., Fujimoto, Y., Osawa, M., Shinobu, A., Hasegawa, K., & Sakamoto, H. (2025) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.25-1530 · Cited by 1
Radiation and effective dose for contrast-enhanced computed tomography angiography procedures
Mansour, A. G. M. A., & Sulieman, A. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113102 · Cited by 1
Yamada, T., Yamato, Y., Hasegawa, T., Yoshida, G., Banno, T., Arima, H., Oe, S., Ide, K., Kurosu, K., & Matsuyama, Y. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14134729 · Cited by 1
Analysis of patient radiation doses in digital interventional cardiology procedures
Ombada, T. H., & Suliman, I. I. (2025) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2025.101814 · Cited by 1
Okungbowa, E. G., & Egonmwan, E. O. (2025) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-025-01535-9 · Cited by 1
Patient-specific dose estimation considering subject thickness with an RGB-D camera: A phantom study
Yasue, K., Fuse, H., Nakazawa, Y., Takahashi, T., Nosaka, H., Koori, N., Takahashi, M., Miyakawa, S., Hanada, K., Urikura, A., et al. (2025) · Radiography · doi:10.1016/j.radi.2025.103181 · Cited by 1
Experimental and Monte Carlo dose assessment in paediatric computed tomography
Wölwitsch, I., Moraleda, M., Gómez-Ros, J. M., & Schlattl, H. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113365 · Cited by 1
Водоватов, А. В., Чипига, Л. А., Kosarlukova, E. A., Библин, А. М., & Вишнякова, Н. М. (2025) · Radiacionnaâ gigiena · doi:10.21514/1998-426x-2025-18-3-46-61 · Cited by 1
Determination of Typical Dose Levels in Mammography Examinations: A Case Study from Türkiye
Sebik, N. B., & TARCAN, G. Y. (2025) · Mersin Üniversitesi Tıp Fakültesi Lokman Hekim Tıp Tarihi ve Folklorik Tıp Dergisi · doi:10.31020/mutftd.1677416 · Cited by 1
Prema, H., Mahesh, M., Sampritha, U., & Aranha, K. N. (2025) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-025-01631-w · Cited by 1
Kito, S., Takizawa, T., Tanabe, S., Suda, Y., Nagahata, T., Tohyama, N., Okamoto, H., Kodama, T., Fujita, Y., Miyashita, H., et al. (2025) · Journal of Radiation Research · doi:10.1093/jrr/rraf080 · Cited by 1
de Assunção, M. F. M., da Silva, J. O., Silva, G. C. C., & Itikawa, E. N. (2025) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2025.2943 · Cited by 1
Arifi, M. M., & Ristova, M. M. (2025) · Journal of Medical Physics · doi:10.4103/jmp.jmp_142_25 · Cited by 1
Higashide, R., & Kanamori, K. (2026) · Radiography · doi:10.1016/j.radi.2025.103303 · Cited by 1
Cavallari, M. R., D’Ercole, L., Grande, S., Klersy, C., Padovani, R., Orlacchio, A., Compagnone, G., Rosi, A., & Palma, A. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112662 · Cited by 1
Self-citationSchröer, B., Yildirim, B., Demircioğlu, A., Drews, M. A., Zensen, S., Opitz, M. K., Ocker-Serger, R. J., Haubold, J., Kinner, S., Breuckmann, K., et al. (2026) · Journal of Radiological Protection · doi:10.1088/1361-6498/ae34be · Cited by 1
Aumalikova, M., Nurseitova, B., Kashkinbayev, Y., Bakhtin, M., Aisauyt, M., Ibrayeva, D., Kusherbayev, N., & Ilbekova, K. (2026) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2026.02.003 · Cited by 1
Ribeiro, C. M. C., Chaves, T. O., Decnop, M., de Mendonça, R. G., Varela, M. C., de Araujo, C. A. V., & Gomes, C. R. B. (2026) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.70508 · Cited by 1
Evaluation of γ-ray effects on a β-ray survey meter with a plastic scintillation sensor
Yamamoto, K., Shindo, R., Inaba, Y., Suzuki, M., Chiba, H., Zuguchi, M., & Chida, K. (2026) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2026.113871 · Cited by 1
Ayanlola, P. S., Kolawole, A. O., Isola, G. A., Bayode, O. P., Orodiran, O. T., Amusat, T. A., Olatunji, A., & Mathew, V. (2026) · Nigerian Journal of Theoretical and Environmental Physics · doi:10.62292/njtep.v4i1.2026.117 · Cited by 1
Chisci, E., Ferrero, E., Antonello, M., Mezzetto, L., Pulli, R., Simonte, G., Gargiulo, M., Pratesi, G., Bertoglio, L., Lazzarotto, T., et al. (2026) · Journal of Endovascular Therapy · doi:10.1177/15266028261440717 · Cited by 1
Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria
Seema, M. D., Dehghan-Dehnavi, A., & Lowane, H. (2026) · Journal of the Colleges of Medicine of South Africa · doi:10.4102/jcmsa.v4i1.279 · Cited by 1
Harb, H., Taguelmimt, K., Benoit, D., Pham, C.-H., Nasr, B., & Bert, J. (2026) · Journal of Radiological Protection · doi:10.1088/1361-6498/ae63da · Cited by 1
Park, H., & Kim, J. (2026) · Applied Sciences · doi:10.3390/app16094466 · Cited by 1
Methodological quality of dental cone-beam CT diagnostic reference levels: a systematic review
Arunmani, B., Horner, K., Coleman, R., Fleischmann, I., & McGuigan, M. B. (2026) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twag036 · Cited by 1
Kobayashi, M., Nishihara, Y., Haba, T., & Kobayashi, S. (2026) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2026.114060 · Cited by 1
A Methodological Evaluation of Dosimetry Studies in Mammography
Ataç, G. K. (2026) · Mersin Üniversitesi Tıp Fakültesi Lokman Hekim Tıp Tarihi ve Folklorik Tıp Dergisi · doi:10.31020/mutftd.1868385 · Cited by 1
Evaluation of exposure incidents in PET-CT examinations through root cause analysis
Oliveros, A. V. O., Jaramillo, J. A. V., Alejo-Martínez, H., Trujillo, J. S., & Salazar, E. (2026) · Physica Medica · doi:10.1016/j.ejmp.2026.105843 · Cited by 1
Beltran, M., Martín, C. P., Sáiz, C. M., Juan, M. J. R. S., Sala, N. J., Gutiérrez, P. S., Monedero, M. P., & Serra, A. S. (2026) · Revista de Física Médica · doi:10.37004/sefm/2026.27.1.002 · Cited by 1
Aminaei, D., Ozlati, A., & de Melo, D. P. (2026) · Cureus · doi:10.7759/cureus.114718 · Cited by 1
Taher, M. R., Jebur, L. Y., Shakir, S. A., & Abojassim, A. A. (2026) · BIO Web of Conferences · doi:10.1051/bioconf/202625504005 · Cited by 1
Incremental Benefit of CT Perfusion to CT Coronary Angiography
Branch, K. R. (2018) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.11.027 · Cited by 1
10. The Activities of J-RIME and the Revision of the DRLs
玲子, 神. (2018) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2018_jsrt_74.6.593 · Cited by 1
Ding, A., Ria, F., & Samei, E. (2019) · Springer eBooks · doi:10.1007/978-3-030-26957-9_11 · Cited by 1
Xpektrin, un simulador de espectros fácil de usar y ampliamente distribuible para radiología general
Olate, C. A. D. L. B., & Jara, M. A. H. (2019) · Revista de Fomento Social · doi:10.4067/s0717-93082019000300094 · Cited by 1
Radiation Risk and Radiation Protection in Paediatric Radiology
Seidenbusch, M. C., Rösenberger, V., & Schneider, K. O. (2019) · Springer eBooks · doi:10.1007/978-3-030-18504-6_1 · Cited by 1
Examination of Effectiveness Verification and Additional Items in Angiography and IVR of DRLs 2015
Sakamoto, H., Igarashi, T., Kato, M., Kawauchi, S., Kato, H., Tsukamoto, A., Moritake, T., & Akahane, M. (2020) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2020_jsrt_76.2.210 · Cited by 1
Manabe, K., & Koyama, S. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa058 · Cited by 1
The Opinions of ICRP for Medical Radiation Exposure
Igarashi, T. (2020) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2020_jjrt_76.7.727 · Cited by 1
Evaluation of Patient Radiation Doses in Skull Radiography
Kaushik, C., Sandhu, I. S., & Srivastava, A. (2019) · Journal of Multidisciplinary Research in Healthcare · doi:10.15415/jmrh.2019.52006 · Cited by 1
Comparison of different approaches for estimating patient effective doses in the Leningrad region
Druzhinina, P. S., Istorik, O. A., Eremina, L. A., Водоватов, А. В., & Shatskiy, I. G. (2020) · AIP conference proceedings · doi:10.1063/5.0013280 · Cited by 1
Ainsbury, E. A. (2020) · Annals of the ICRP · doi:10.1177/0146645320946629 · Cited by 1
Seraphim, D. M., & Fischer, A. C. F. D. S. (2020) · Brazilian Journal of Radiation Sciences · doi:10.15392/bjrs.v8i3.1208 · Cited by 1
Ammari, T., Ferreira, C. D. F., Jordan, D. J., MacDonald, N., & Rust, P. (2020) · The Surgeon · doi:10.1016/j.surge.2020.08.007 · Cited by 1
Mohammed, R., Mraity2, H. A. A. B., Hadi3, B. H., & Dana3, S. H. (2020) · Medico-Legal Update · doi:10.37506/mlu.v20i4.1854 · Cited by 1
Analysis of Collocated Base Transceiver Stations And Associated Risks in Erecting Base Stations
Antwi, O. A., Owusu, A. O., Nanjo, J. W., Gidisu, G. B., Sackey, D., & Mohammed, H. (2021) · International Conference on Computing, Computational Modelling and Applications (ICCMA) · doi:10.1109/iccma53594.2021.00023 · Cited by 1
Opitz, M. K., Zensen, S., Bos, D., Wetter, A., Kleinschnitz, C., Uslar, E., Jabbarli, R., Sure, U., Radbruch, A., Li, Y., et al. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac32a2 · Cited by 1
Kracmerova, T., & Holm, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822960-6.00050-8 · Cited by 1
Ishibashi, T., Masuda, T., Kato, M., Yamashita, Y., Takei, Y., Tsukamoto, A., Matsumoto, K., & Sakamoto, H. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab185 · Cited by 1
Editorial, A. (2022) · Diagnostic radiology and radiotherapy · doi:10.22328/2079-5343-2022-13-s-159-174 · Cited by 1
Current Radiographic Practices and Radiation Dose Evaluation
Kaushik, C., Sandhu, I. S., Srivastava3, A., & Chitkara, M. (2020) · Indian Journal of Public Health Research & Development · doi:10.37506/ijphrd.v11i7.10078 · Cited by 1
Dose evaluation in paediatric patients undergoing skull examinations
Vosiak, P., Yagui, A., Bunick, A. P., Schelin, H. R., Mello, R. G., Pedrazzani, B. M., Denyak, V., Paschuk, S. A., Khoury, H. J., & Schelin, A. B. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110382 · Cited by 1
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.