ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 401–500 of 1,000
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Alhorani, Q., Alkhybari, E., Rawashdeh, M., Sabarudin, A., Latiff, R. A., Al-Ibraheem, A., & Mohamad, M. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad2c62 · Cited by 6
“According to Va ˜ nó et al [11], DRL does not signify a specific dosage limit and does not distinguish between ‘good’ and ‘bad’ practices.”
InfluentialMammography diagnostic reference levels in Western Australia
Storm, C., Harvey, A. W., & Djukelic, M. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00914-y · Cited by 6
Nalwoga, K., Nankya, E., Erem, G., Mayanja, J. M. K., Kiraga, F., Mubuuke, A. G., & Kisembo, H. N. (2023) · Research Square · doi:10.21203/rs.3.rs-2683913/v1 · Cited by 6
Establishment of typical adult CT dose indicators for PET-CT scans in Slovenia
Perić, J., Mekiš, N., & Žontar, D. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac025a · Cited by 6
PATIENT DOSES IN WHOLE-BODY PET/CT EXAMINATIONS IN THE LARGEST TERTIARY HOSPITAL IN GREECE
Tzampazidou, E., Fotina, A. A., Chatonidis, V., Tsalafoutas, I. A., Datseris, I., & Samartzis, A. P. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab169 · Cited by 6
Radiation doses from low-dose CT scans in SPECT/CT and PET/CT examinations: A survey in Germany
Rinscheid, A., Janzen, T., Alikhani, B., Beer, A. J., Braune, A., Eberhardt, N., Fechner, D., Förster, S., Freesmeyer, M. G., Furth, C., et al. (2022) · Nuklearmedizin - NuclearMedicine · doi:10.1055/a-1759-3900 · Cited by 6
Valores típicos de dosis para tomografía computada de cerebro en pacientes adultos
Andrea Serra, H., Cristián Ramírez, M., Javier Véliz, H., María Isabel Salas, O., José Pérez, A., Felipe Vera, M., & Juan Morales, G. (2020) · Revista de Fomento Social · doi:10.4067/s0717-93082020000100025 · Cited by 6
RADIATION DOSE DURING PELVIC RADIOGRAPHY IN RELATION TO BODY MASS INDEX
Zalokar, N., Resnik, A., & Mekiš, N. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa042 · Cited by 6
Pedrosa, K. F. S., Engler, C., & Nogueira, M. S. (2022) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2022.110625 · Cited by 6
ESTIMATION OF PEDIATRIC DOSE DESCRIPTORS ADAPTED TO INDIVIDUAL SPECIFIC SIZE FROM CT EXAMINATIONS
Abdulkadir, M. K., Shuaib, I. L., Achuthan, A., Nasirudin, R. A., Samsudin, A. H. Z., & Osman, N. D. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac163 · Cited by 6
Brambilla, M., D’Alessio, A., Kuchcińska, A., Šegota, D., & Súkupová, L. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac5670 · Cited by 6
Recent Trends in Medical Radiation Protection
Igarashi, T. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1311 · Cited by 6
Alonso, S. M., Montes, M. Á. P., Soto, J. M. F., Ordiales, J. M., Alejo, L., Almansa, J. F., & Gelabert, J. F. (2020) · Revista de Física Médica · doi:10.37004/sefm/2020.21.1.004 · Cited by 6
Current practices and perceptions on diagnostic reference levels: a EuroSafe Imaging Survey Analysis
Damilakis, J. E., Brkljačić, B., Frija, G. G., Bondt, T. D., Paulo, G., Tsapaki, V., Vano, E., & the European Society of Radiology (ESR) (2025) · Insights into Imaging · doi:10.1186/s13244-025-02028-z · Cited by 6
Suttho, D. (2024) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.123.266836 · Cited by 6
Patient Dose Estimation in Computed Tomography-Guided Biopsy Procedures
Siomou, E., Filippiadis, D. K., EFSTATHOPOULOS, E. P., Antonakos, I., & Panayiotakis, G. (2023) · Journal of Imaging · doi:10.3390/jimaging9120267 · Cited by 6
Alsafi, K. (2025) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2025.101304 · Cited by 6
Amalia, T., Zulkarnaien, B., Anam, C., Nurcahyo, K., Tussyadiah, H., & Pradana, D. E. (2022) · Atom Indonesia · doi:10.17146/aij.2022.1131 · Cited by 6
Kito, S., Suda, Y., Tanabe, S., Takizawa, T., Nagahata, T., Tohyama, N., Okamoto, H., Kodama, T., Fujita, Y., Miyashita, H., et al. (2023) · Journal of Radiation Research · doi:10.1093/jrr/rrad098 · Cited by 6
Local diagnostic reference levels for paediatric chest computed tomography in Morocco
Benmessaoud, M., Dadouch, A., Maghnouj, A., Lemmassi, A., Ouaggou, I. A., Hadda, H. O., & El-ouardi, Y. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.110794 · Cited by 6
Mbewe, J., & Mjenxane, T. (2022) · Polish Journal of Medical Physics And Engineering · doi:10.2478/pjmpe-2022-0021 · Cited by 6
Pediatrics organ dose and lifetime attributable cancer risk estimates in routine computed tomography
Alenazi, K., Alkhybari, E. M., Alhailiy, A. B., Alghamdi, S., Fisal, N., & Albeshan, S. M. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.112021 · Cited by 6
Brambilla, M., Chmelík, M., Cannillo, B., Klepanec, A., Lacko, M., Andreatta, P., & Šalát, D. (2024) · European Radiology · doi:10.1007/s00330-024-11240-2 · Cited by 6
Genetay, T., Gamulin, A., Lorimier, A., & Merce, M. S. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae175 · Cited by 6
Kim, J., Yeom, H.-G., Hwang, J. J., Choi, Y. J., Han, J.-W., An, S., Kim, G., Lee, J.-S., Kim, J.-S., Kim, K.-A., et al. (2025) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twaf014 · Cited by 6
Ampofo, R. Y., Kyei, K. A., Daniels, J. P., & Nyantakyi, A. Y. (2025) · BMC Medical Imaging · doi:10.1186/s12880-025-01860-5 · Cited by 6
Kržanović, N., Toroi, P., Коматина, И., Jansen, B., Boziari, A., Caldeira, M., Castro, M. C., Ciccotelli, A., Fernandes, A. C., Kojić, A., et al. (2025) · Physica Medica · doi:10.1016/j.ejmp.2025.105687 · Cited by 6
Bouaoun, A., Omrane, L. B., & Khomssi, W. D. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac767a · Cited by 6
Xu, H., Baorong, Y., Cheng, J., Deng, J., Su, Y., Zhao, Q., Xue, K., Feng, Z., Niu, Y., & Sun, Q. (2024) · Health Physics · doi:10.1097/hp.0000000000001853 · Cited by 6
Hwang, J., Yoon, H. M., Hwang, J., Choi, Y. H., Lee, Y. Y., Lee, S. M., Ryu, Y. J., You, S. K., Park, J. E., & Lee, S. K. (2025) · Korean Journal of Radiology · doi:10.3348/kjr.2024.0689 · Cited by 6
Roch, P., Célier, D., Dessaud, C., & Étard, C. (2018) · Radioprotection · doi:10.1051/radiopro/2018003 · Cited by 7
Zucca, S., Solla, I., Boi, A., Loi, S., Rossi, A., Sanna, F., & Loi, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.04.019 · Cited by 6
Praskalo, J., Beganović, A., Milanovic, J. Z., & Stanković, K. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa081 · Cited by 6
Niroshani, H. S., Jeyasugiththan, J., Senanayake, G., & Negishi, T. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/abd075 · Cited by 6
Delis, H., Homolka, P., Chapple, C.-L., Costa, P. R., Attalla, E. M., Lubis, L. E., Sackey, T. A., Fahey, F. H., Laßmann, M., & Poli, G. L. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.009 · Cited by 6
Wang, W.-H., Wei, K., Huang, W., Yen, Y.-Y., & Mar, G.-Y. (2021) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd8080099 · Cited by 6
Anasthesia, A. E., Ibrahim, U., Yusuf, S. D., Joseph, D. Z., Nkubli, F. B., Sidi, M., Shem, S., Mundi, A. A., Dare, A. T., Joseph, D. S., et al. (2022) · Journal of the Nigerian Society of Physical Sciences · doi:10.46481/jnsps.2022.734 · Cited by 6
Dose Reduction and Optimization Strategies in Computed Tomography
Seeram, E. (2023) · Springer eBooks · doi:10.1007/978-3-031-22871-1_5 · Cited by 6
Nassar, J., Rizk, C., Farah, J., & Fares, G. (2023) · Radioprotection · doi:10.1051/radiopro/2023023 · Cited by 6
Sulieman, A., Alkhorayef, M. A., Alkhaybari, E., Jaafar, R., Elnour, A., Almujally, A., Babikir, E., Abuzaid, M., Abuhadi, N. H., Salah, H., et al. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111460 · Cited by 6
Saeed, M. K., Abdallah, Y. M. Y., & Sulieman, A. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110470 · Cited by 6
Sulieman, A., Tamam, N. M., Khandaker, M. U., Bradley, D. A., & Padovani, R. (2020) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2020.108991 · Cited by 6
Self-citationDiagnostic Reference Levels for Common X-ray Procedures in Peru
Bonifaz, A. P., Rodriguez, C. S. C., & Esparza, R. P. (2021) · Cureus · doi:10.7759/cureus.18566 · Cited by 6
Clinical indication-based diagnostic reference levels in CT: a systematic review
Alim, A., Leong, S. S., Sudin, A. E. L. T., & Awla, D. H. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-104530 · Cited by 5
An image quality assessment index based on image features and keypoints for X-ray CT images
Maruyama, S., Watanabe, H., & Shimosegawa, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0304860 · Cited by 5
Aloufi, K. M., Gameraddin, M., Alhazmi, F. H., Almazroui, I. S., Osman, H., & Khandaker, M. U. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2024.111583 · Cited by 5
Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia
Said, A. A., Rahman, A. A., Halim, F. N. B. A., Albadarneh, L., Oglat, A. A., Saleh, H. H., Shloul, W., & Alshloul, Y. (2025) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf053 · Cited by 5
Ng, J. J., Arlany, L., Chiam, A., Ong, Y., & Lian, C. P. L. (2022) · Singapore Medical Journal · doi:10.11622/smedj.2022038 · Cited by 5
Clinical diagnostic reference levels and image quality metrics for CT in oncology patients
Sebelego, I., Acho, S., & Rae, W. I. D. (2024) · South African Journal of Radiology · doi:10.4102/sajr.v28i1.2960 · Cited by 5
Patil, N. B., Priyanka, S, P. P., Kadavigere, R., & Pendem, S. (2026) · Technical Innovations & Patient Support in Radiation Oncology · doi:10.1016/j.tipsro.2026.100374 · Cited by 5
The influence of patient size on the overall uncertainty in radiographic dose audit
Sutton, D., Worrall, M., Sexton, K., Loon, M. V., McVey, S., & O’Neill, J. C. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/abfff6 · Cited by 5
Kostova-Lefterova, D. Z., Shalganov, T. N., Stoyanov, M. K., TRAYKOV, V. B., Boychev, D., Protich, M., & Bonev, N. B. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.102572 · Cited by 5
Mésnard, T., Huang, Y., Schanzer, A. S., Timaran, C. H., Schneider, D. B., Mendes, B. C., Eagleton, M. J., Farber, M. A., Parodi, F. E., Gasper, W. J., et al. (2025) · Annals of Surgery · doi:10.1097/sla.0000000000006676 · Cited by 5
Radiation Safety in Nuclear Medicine: Report I. Topical Problems
Narkevich, B. Y. (2021) · Medical Radiology and radiation safety · doi:10.12737/1024-6177-2021-66-1-29-36 · Cited by 5
Relationship between radiation dose indices and patient size in adult brain computed tomography
Mitsui, K., Inoue, Y., Itoh, H., HATA, H., Miyatake, H., & Yamane, T. (2025) · Radioprotection · doi:10.1051/radiopro/2024033 · Cited by 5
Ichikawa, S., Itadani, H., & Sugimori, H. (2023) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.14080 · Cited by 5
Sebelego, I., Acho, S., van der Merwe, B., & Rae, W. I. D. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad059 · Cited by 5
Establishment of a local diagnostic reference level for dental intraoral bitewing X-rays
Storm, C., & Nezich, R. (2023) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-023-01247-2 · Cited by 5
Diagnostic Reference Levels for Common CT Examinations: Results from a Statewide dose Survey
Jusoh, I. I., Abdullah, K. A., & Ali, M. H. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac182 · Cited by 5
Elshami, W., Abuzaid, M., Zira, J. D., Tekin, H. O., & Ghonim, H. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.964104 · Cited by 5
Photon-Counting CT Scan Phantom Study: Stability of Radiomics Features
Dawi, L., Amouzouga, K., Muller, S. L., Nallet, C., Dupont, A. M., Vielliard, B., Croisille, C., Moussier, A., Garcia, G. C. T. E., Bidault, F., et al. (2025) · Diagnostics · doi:10.3390/diagnostics15060649 · Cited by 5
Hameedat, S. F., Radzi, Y. M., Salman, M. D., Alshipli, M., & Hmaidat, A. F. (2026) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2026.102207 · Cited by 5
Typical values related to the complexity of interventional treatment of acute ischemic stroke
Cavallari, M., D’Ercole, L., Klersy, C., Sanfilippo, G., Sgreccia, A., Huasen, B. B., Zappoli, F., & Lafe, E. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.09.016 · Cited by 5
Hamedat, S. F., Radzi, Y. M., Salman, M. D., & Alshipli, M. (2025) · Radiography · doi:10.1016/j.radi.2025.103158 · Cited by 5
Diagnostic reference levels in Africa: a protocol for systematic review and meta-analysis
Adekanmi, A., Akinlade, B. I., & Adedoyin, O. A. (2025) · African Health Sciences · doi:10.4314/ahs.v25i1.15 · Cited by 5
Cacioppa, L. M., Mariotti, F., Mari, A., Bruno, A., Rossini, N., Francavilla, G., Macchini, M., Rosati, M., Matteagi, D., Veccia, P., et al. (2026) · La radiologia medica · doi:10.1007/s11547-025-02163-z · Cited by 5
Laurén, J., Kaasalainen, T. T., Kesävuori, R. I., Nikulainen, V., Suominen, V., Hakulinen, U., Karjalainen, J. M., Kariniemi, J., Venermo, M. A., Aho, P., et al. (2025) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2026.06.074 · Cited by 5
Schegerer, A., Jungnickel, K., Walz, M., Verius, M., Singer, J., Renger, B. C., Oberhofer, N., Müller, C., Menz, R., Madsack, B., et al. (2026) · Insights into Imaging · doi:10.1186/s13244-026-02241-4 · Cited by 5
O’Hora, L., O’Brien, K., Tuffy, J., Craig, A., Neville, N., Sugrue, K., Keaveney, M., O’Brien, E. Z., Quinn, E., & Egan, S. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111890 · Cited by 5
Gomes, Y. E., Brown, G. C., Davies, J., Parange, N., & Chau, M. T. (2022) · Pediatric Radiology · doi:10.1007/s00247-022-05290-1 · Cited by 5
Okamoto, H., Kito, S., Tohyama, N., Yonai, S., Kawamorita, R., Nakamura, M., Fujimoto, T., Tani, S., Yomoda, A., Isobe, T., et al. (2020) · Journal of Radiation Research · doi:10.1093/jrr/rraa088 · Cited by 5
Alenazi, K., Alkhybari, E. M., Alhailiy, A. B., Alahmad, H. N., Alghamdi, S., Fisal, N., & Albeshan, S. M. (2025) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2025.101371 · Cited by 5
Clinical and technical challenges associated with CT dose optimization in practice
Dalah, E. Z., & Bradley, D. A. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.111903 · Cited by 5
Radiation Dose Tracking in Computed Tomography Using Data Visualization
Alotaibi, R. M., & Abukhodair, F. (2023) · Technologies · doi:10.3390/technologies11030074 · Cited by 5
Almuqbil, N., Hamd, Z. Y., Elshami, W., & Abuzaid, M. (2025) · Diagnostics · doi:10.3390/diagnostics15151849 · Cited by 5
An evaluation of CT radiation doses within the Yorkshire Lung Screening Trial
Iball, G. R., Beeching, C. E., Gabe, R., Tam, H. Z., Darby, M. J., Crosbie, P. A. J., & Callister, M. E. J. (2023) · British Journal of Radiology · doi:10.1093/bjr/tqad045 · Cited by 5
Diagnostic Reference Levels in Paediatric Fluoroscopy: A Single-Centre Study in South Africa
Mbewe, J., & Payne, T. (2024) · South African Radiographer · doi:10.54450/saradio.2024.62.1.825 · Cited by 5
Geryes, B. H., Bernardie, S. B. D. L., Hascoët, S., Geant, C., Dauphin, C., Douchin, S., Rousseau, J., Godart, F. R., Pontvianne, V., Reggio, C. O., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0332241 · Cited by 5
Sowa, M. S., Sowa, J., Węglarz, K., & Budzanowski, M. (2025) · Journal of Radiological Protection · doi:10.1088/1361-6498/ae1403 · Cited by 5
Dehlinger, N., Dillenseger, J., Pop, R., Hasiu, A., Bonnard, L., & Léonard-Lorant, I. (2025) · Radiography · doi:10.1016/j.radi.2025.103254 · Cited by 5
Sowa, M. S., Sowa, J., Węglarz, K., & Budzanowski, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15052059 · Cited by 5
A Decade of Change in Adult CT Radiation Doses: 2025 U.S. Diagnostic Reference Levels
Kanal, K. M., Frush, D. P., Gingold, E. L., Mahesh, M., Samei, E., Breeden, W. K., Larson, D. B., Christianson, O. I., & Griglock, T. M. (2026) · Radiology · doi:10.1148/radiol.260322 · Cited by 5
Abuzaid, M., Elshami, W., Cavlı, B., Ozturk, C., ALMisned, G., & Tekin, H. O. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111025 · Cited by 5
Stein, T., Schürmann, T., Bamberg, F., & Müller‐Peltzer, K. (2023) · Die Radiologie · doi:10.1007/s00117-023-01196-7 · Cited by 5
Modlińska, S., Kufel, J., Janik, M., Czogalik, Ł., Dudek, P., Rojek, M., & Zbroszczyk, M. (2024) · Brain Sciences · doi:10.3390/brainsci14080799 · Cited by 5
Metaxas, V. I., Savvakis, S., Skouridi, E., Kaolis, D., Gkaras, G., Hadjilampi, C., Stamatakis, E., Papadelis, E. A., Pistevos, C., & Prodromou, P. (2024) · Injury · doi:10.1016/j.injury.2024.112089 · Cited by 5
Assessment of Occupational Exposure in Some Radiology Departments in Ghana
Akyea-Larbi, K. O., Gbeddy, G., Amoatey, E. A., Manteaw, P. O., & Otoo, F. (2025) · Health Physics · doi:10.1097/hp.0000000000001973 · Cited by 5
Prabsattroo, T., Phaorod, J., Tathuwan, P., Tongluan, K., Punikhom, P., Maharantawong, T., & Sudchai, W. (2025) · Journal of Imaging · doi:10.3390/jimaging11030070 · Cited by 5
Variabilities in X-ray diagnostic reference levels
Vanaudenhove, T., Muylem, A. V., Howarth, N., Gevenois, P. A., & Tack, D. (2020) · European Radiology · doi:10.1007/s00330-020-06819-4 · Cited by 5
Makanjee, C. R., Lipscombe, E., Haniz, A. N., & Cho, Y. S. (2021) · Health Physics · doi:10.1097/hp.0000000000001427 · Cited by 5
Sasaki, M., OGINO, H., & Hattori, T. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac057f · Cited by 5
Yagui, A., Vosiak, P., Schelin, H. R., Denyak, V., Filipov, D., Paschuk, S. A., & Khoury, H. J. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110341 · Cited by 5
DIAGNOSTIC REFERENCE LEVELS IN SCREENING MAMMOGRAPHY CENTERS IN SLOVAKIA
Šalát, D., Nikodemová, D., Klepanec, A., Lehotská, V., & Šalátová, A. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac095 · Cited by 5
Dalah, E. Z., Musfari, Y. M. A., Ali, B. M. H., Hammadi, A. A. A., Beevi, H. A. A., Jaber, M. I., Al-Ali, A. A., Alkharoossi, A. K., Hashemi, F. H. A., Alkhatib, F. M., et al. (2022) · Healthcare · doi:10.3390/healthcare10101970 · Cited by 5
Muti, G., Riga, S., Berta, L., Mattia, C. D., Felisi, M., Rizzetto, F., Torresin, A., Vanzulli, A., & Colombo, P. E. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.102746 · Cited by 5
Ilo, A.-M., Waltimo‐Sirén, J., Esmaeili, E. P., Ekholm, M., & Kortesniemi, M. (2023) · Acta Odontologica Scandinavica · doi:10.1080/00016357.2023.2258981 · Cited by 5
Determination of the Diagnostic Reference Level (DRL) in Samarinda Hospitals
Jannah, R., Munir, R., & Putri, E. R. (2023) · Atom Indonesia · doi:10.55981/aij.2023.1285 · Cited by 6
Semghouli, S., Fahssi, M. E., Choukri, A., & Amaoui, B. (2024) · Radioprotection · doi:10.1051/radiopro/2024007 · Cited by 5
Rehani, M. M., Mataac, M. T., & Li, X. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.03.026 · Cited by 5
Self-citation
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.