ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 501–600 of 1,000
Radiation Protection for Patients
Dauer, L. T., Mattsson, S., Vano, E., & Yonekura, Y. (2019) · Springer eBooks · doi:10.1007/978-3-319-95564-3_12 · Cited by 5
Self-citationFarah, J., Gonzalez-Mendez, L. A., Dufay, F., Amir, S., Royer, B., Gabriel, H., & Noël, A. (2020) · Journal of Radiological Protection · doi:10.1088/1361-6498/abac4f · Cited by 5
Diklić, A., Zujić, P. V., Šegota, D., Debeljuh, D. D., Jurković, S., Brambilla, M., & Kalra, M. K. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.09.014 · Cited by 5
Investigation of a method for creating neonatal chest phantom using 3D printer
Fujibuchi, T. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1943/1/012056 · Cited by 5
Zensen, S., Opitz, M. K., Grueneisen, J. S., Li, Y., Haubold, J., Steinberg, H., Forsting, M., Theysohn, J. M., Bos, D., & Schaarschmidt, B. M. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac7e80 · Cited by 5
Dimov, A., Tsanev, I., Ivanova, D., & Simeonov, F. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_7 · Cited by 5
X-ray examination dose surveys: how accurate are my results?
Taylor, S. E., Muylem, A. V., Howarth, N., Gevenois, P. A., & Tack, D. (2019) · European Radiology · doi:10.1007/s00330-019-06055-5 · Cited by 5
Suomi, V., Järvinen, J., Kiviniemi, T., Ylitalo, A., & Pietilä, M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103725 · Cited by 5
Local diagnostic reference levels for skeletal surveys in suspected physical child abuse
Mussmann, B. R., Hardy, M., Rajalingam, R., Peters, D., McFadden, S. L., & Abdi, A. J. (2020) · Radiography · doi:10.1016/j.radi.2020.10.005 · Cited by 5
Rial, R., & Vano, E. (2021) · EJVES Vascular Forum · doi:10.1016/j.ejvsvf.2021.03.001 · Cited by 5
Garba, I., & Engel-Hills, P. (2025) · Radiography · doi:10.1016/j.radi.2024.09.058 · Cited by 4
Ridhwan, A. F. M., Chen, E.-J., Selvam, H. S. S., & Chew, M. T. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111022 · Cited by 4
Steuwe, A., Thomas, C. K., Kraus, B., Bethge, O., Aissa, J., Klosterkemper, Y., Antoch, G., & Boos, J. (2019) · Journal of Radiological Protection · doi:10.1088/1361-6498/ab4d00 · Cited by 4
Mendoza, H. I. S., González-Ruíz, A., Isaac‐Olivé, K., Flores‐Merino, M. V., Santos‐Cuevas, C., Preza-Hernandez, D., Ortiz-Oliveros, H. B., & Isidro-Ortega, F. J. (2025) · Radiography · doi:10.1016/j.radi.2025.102932 · Cited by 4
Alruwaili, T., Alsubaie, B., Altimyat, S., & Soliman, K. (2023) · Journal of Applied Mathematics and Physics · doi:10.4236/jamp.2023.117135 · Cited by 4
Estimation of diagnostic reference levels for pediatric head computed tomography in Yaoundé
Kamdem, E. F., Fotué, A. J., Kouam, B. F., Abogo, S., & Samba, O. N. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad298 · Cited by 4
Graves, S. A., Bushnell, D. L., Schultz, M. K., Jain, S., Bodeker, K. L., & Menda, Y. (2026) · Journal of Nuclear Medicine · doi:10.2967/jnumed.125.270083 · Cited by 4
Sample Size and Estimation of Standard Radiation Doses for Pediatric Brain CT
Inoue, Y., Itoh, H., Shiibashi, N., Sasa, R., & Mitsui, K. (2022) · Tomography · doi:10.3390/tomography8050207 · Cited by 4
The status of radiation protection in medicine in the Asia‐Pacific region
Ng, K. H., Brady, Z., Ng, A. H., Soh, H. S., Chou, Y., & Varma, D. (2021) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13165 · Cited by 4
Lopez, D., López, A., Santos-Gutiérrez, F., Salvador-Hernández, L., Torres-Aroche, L. A., & Renha, S. K. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.112043 · Cited by 4
Patient radiation safety in the intensive care unit
Quaia, E. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf147 · Cited by 4
The mandate and work of ICRP Committee 3 on radiological protection in medicine
Miller, D. L., Martin, C. J., & Rehani, M. M. (2018) · Annals of the ICRP · doi:10.1177/0146645318756249 · Cited by 4
Self-citationNocum, D. J., Robinson, J., Halaki, M., Båth, M., Mekiš, N., Liang, E. Y., Thompson, N., Moscova, M., & Reed, W. M. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab145 · Cited by 4
Hwang, J.-H., Park, C.-K., Lee, K.-B., & Lee, T.-S. (2021) · Journal of the Korean Physical Society · doi:10.1007/s40042-021-00189-w · Cited by 4
Druzhinina, Y. V., Lantukh, Z. A., Водоватов, А. В., Morozov, S. P., Ryzhov, S. A., Sokolov, E. N., Shatenok, M. P., Чипига, Л. А., & Tolkachev, K. V. (2022) · Meditsinskaya Fizika · doi:10.52775/1810-200x-2022-93-1-81-96 · Cited by 4
Welarathna, S., Sivakumar, V., & Sarasanandarajah, S. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/acfc51 · Cited by 4
D’Ercole, L., Rosi, A., Bernardi, G., Compagnone, G., Orlacchio, A., Padovani, R., Palma, A., & Grande, S. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad1fe1 · Cited by 4
Self-citationTzanis, E., & Damilakis, J. E. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.103140 · Cited by 4
Lyons, A., Ali, A. M., England, A., Moore, N., Young, R., Leamy, B., Tam, W., Bezzina, P., Pongnapang, N., & McEntee, M. F. (2024) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2024.04.014 · Cited by 5
Impact of equipment technology on reference levels in fluoroscopy-guided gastrointestinal procedures
Rehani, M. M., & Li, X. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.103330 · Cited by 4
Self-citationBotwe, B. O., Anim-Sampong, S., & Saizi, R. (2025) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/6464273 · Cited by 4
Albahiti, S. K., Khafaji, M. A., Batawil, N., Catipay, N., & Alsafi, K. (2024) · Cureus · doi:10.7759/cureus.54230 · Cited by 4
Garba, I., Engel-Hills, P. C., Davidson, F., & Ismail, A. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae094 · Cited by 4
Schegerer, A., Stamm, G., Aberle, C., Ammon, J., Bazrafshan, B., Borowski, M., Eßeling, R., Madsack, B., Menz, R., Müller, C., et al. (2024) · European Radiology · doi:10.1007/s00330-024-11224-2 · Cited by 4
Abulail, A., Rahman, A. A., Azman, N. Z. N., & Hassan, J. (2023) · Applied Sciences · doi:10.3390/app13084662 · Cited by 4
Nissanka, M., Satharasinghe, D., Jeyasugiththan, J., Bandara, W. R. U. A., Wijayasinghe, W., WEERAPPERUMA, I. D., Jayasuriya, N. S. S., & Jayasinghe, R. D. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae215 · Cited by 4
Borzì, G. R., Bonanno, E., Cavalli, N., D’Anna, A., Pace, M., Stella, G., Zirone, L., & Marino, C. (2025) · Applied Sciences · doi:10.3390/app15063338 · Cited by 4
Zorz, A., Morzenti, S., Bianchi, C. L., Campanaro, F., Monte, F. D., Ponti, E. D., Berti, S., Erba, P. A., Guerra, L., & Poli, G. L. (2025) · Physica Medica · doi:10.1016/j.ejmp.2025.104984 · Cited by 4
Elamri, N., Bougteb, M., Tahiri, M., Baydaoui, R. E., & Mkimel, M. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.112892 · Cited by 4
Fujikawa, A., Matsuoka, S., Saito, Y., Arizono, S., Nakamura, K., Kato, A., Tanuma, T., & Mimura, H. (2025) · Japanese Journal of Radiology · doi:10.1007/s11604-025-01887-2 · Cited by 4
Nogueira, P., & Rühm, W. (2020) · Journal of Radiological Protection · doi:10.1088/1361-6498/abbe36 · Cited by 4
Typical air kerma area product values for trauma orthopaedic surgical procedures
Škrk, D., Petek, K., Pekarovič, D., & Mekiš, N. (2021) · Radiology and Oncology · doi:10.2478/raon-2020-0066 · Cited by 4
Dambele, M. Y., Bello, S. G., Ahmad, U. F., Jessop, M., Isa, N. F., & Agwu, K. K. (2021) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.121.262084 · Cited by 4
Sothmann, P. J., Groenewald, W. A., Doubell, A. F., & Pitcher, R. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab143 · Cited by 4
Özpeynirci, Y., Trumm, C. G., Stahl, R., Liebig, T., & Forbrig, R. (2022) · Diagnostics · doi:10.3390/diagnostics12020531 · Cited by 4
Arabi, M., Rajeh, A., AlHendi, N. D., Alotaibi, K. T., Yahyan, T. A., Alyousef, K., & Ardah, H. I. (2022) · Saudi Medical Journal · doi:10.15537/smj.2022.43.9.20220194 · Cited by 4
Establishing Protocol-based Dose Metrics for Common Abdomen and Pelvis Computed Tomography Protocols
Dalah, E. Z., AlSuwaidi, J. S., AlKetbi, R., AlMulla, M., & Gupta, P. (2023) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405620666230522151357 · Cited by 4
Plain radiography has a role to play in current clinical practice in Western Switzerland
dos Reis, C. S., Gulizia, M., Champendal, M., Labouchère, S. D., Sun, Z., & Silva, C. (2023) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2023.08.007 · Cited by 4
Kakuta, K., Nemoto, S., & Ikeda, M. (2023) · Radiological Physics and Technology · doi:10.1007/s12194-023-00742-1 · Cited by 4
Cavallari, M., D’Ercole, L., Zucca, S., Paruccini, N., Solla, I., Fusaro, F., Ferrari, A., Klersy, C., Sanfilippo, G., Patassini, M., et al. (2024) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-023-04790-9 · Cited by 4
Nishida, T., Hayashi, S., Takenaka, M., & Hosono, M. (2024) · Journal of Gastroenterology · doi:10.1007/s00535-024-02106-x · Cited by 4
Albadarneh, L., Rahman, A. A., Ewaidat, H. A., Rawashdeh, M. A., Saleh, H. H., Said, A. A., Mhanna, H. Y. A., & Hatif, A. R. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.111931 · Cited by 4
Huber, R. A., Choukroun, É., Fahrenholz, H., & Notter, F. (2025) · Medical Devices Evidence and Research · doi:10.2147/mder.s491331 · Cited by 4
Arifi, M. M., & Ristova, M. M. (2025) · Diagnostics · doi:10.3390/diagnostics15060682 · Cited by 4
Banks, K. P., Gunther, R. S., Farrell, M. B., Peacock, J. G., Costello, M., & Gordon, L. L. (2021) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.120.261552 · Cited by 4
Ríos, E. A., & Arango, E. T. M. (2021) · Revista Investigaciones y Aplicaciones Nucleares · doi:10.32685/2590-7468/invapnuclear.5.2021.604 · Cited by 4
Esien-umo, E., Chiaghanam, N. O., Erim, A. E., Effa, M., & Egbe, N. (2022) · Bulletin of the National Research Centre/Bulletin of the National Research Center · doi:10.1186/s42269-022-00907-9 · Cited by 4
Abdou, S. E., Salama, D. H., Ahmad, K. A., Sallam, A., El-Sayed, E.-S., & Talaat, M. H. (2021) · Kasr Al Ainy Medical Journal · doi:10.4103/kamj.kamj_9_22 · Cited by 4
Masjedi, H., Dalvand, S., Zamani, H., Zare, M. H., & Zarei, M. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110593 · Cited by 4
Shkumat, N. A., Chiramel, G. K., Muthusami, P., Parra, D. A., Temple, M. J., & Amaral, J. (2023) · Pediatric Radiology · doi:10.1007/s00247-022-05562-w · Cited by 4
Gazdag-Hegyesi, S., Gáldi, Á., Major, T., & Pesznyák, C. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad101 · Cited by 4
Jeyasugiththan, J., Bandara, B. G. U. M., Wickramarathna, S. H. D., Thenuwara, H., Satharasinghe, D., Pallewatte, A. S., & Hettiarachchi, P. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/ace833 · Cited by 4
Al-Horani, Q., Alkhybari, E. M., Rawashdeh, M. A., Sabarudin, A., Latiff, R. A., Al‐Ibraheem, A., Vinjamuri, S., & Mohamad, M. (2023) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001748 · Cited by 4
Tokura, J., Yoshio, T., Hayashi, S., Yamamoto, M., Asai, S., Yakushijin, T., Ikezawa, K., Nagaike, K., Takagi, T. J., Fujisawa, T., et al. (2023) · JGH Open · doi:10.1002/jgh3.12993 · Cited by 4
Osman, H., Ahmed, A. M., Musa, A., Medani, A. M. A., Abouraida, R. A., Alelyani, M., Alamri, S. S., AbdElrahim, E., Hassan, W., Faizo, N. L., et al. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.111482 · Cited by 4
ESTIMATES OF PATIENT DOSES AND KERMA-AREA PRODUCT MONITORING IN DIGITAL RADIOGRAPHY
Kaushik, C., Sandhu, I. S., & Srivastava, A. K. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa072 · Cited by 4
Opitz, M. K., Zensen, S., Ludwig, J. M., Weber, M., Alatzides, G. L., Seifert, R., Grüneisen, J., Theysohn, J. M., Bos, D., & Schaarschmidt, B. M. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac8f9e · Cited by 4
Dalah, E. Z., & Bradley, D. A. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.110948 · Cited by 4
Nagaike, K., Hayashi, S., Yakushijin, T., Yamamoto, M., Sumiyoshi, T., Yamaguchi, S., Tamaru, Y., Yamada, T., Tsumura, H., Nakai, Y., et al. (2023) · British Journal of Radiology · doi:10.1259/bjr.20230086 · Cited by 4
Multicenter Survey on Radiation Dose of Cardiac Intervention
Hayashi, T., Watanabe, Y., Imazeki, M., Takeda, K., Sakiyama, K., Hasegawa, R., Tajima, O., Tsukamoto, A., Sato, H., Shiraki, H., et al. (2020) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2020_jjrt_76.7.715 · Cited by 4
Kobayashi, Y., Kobayashi, M., Kanamori, D., Fujii, N., Kataoka, Y., Satoh, K., Sano, Y., Yoshioka, S., Tateya, I., Toyama, H., et al. (2021) · The Cleft Palate-Craniofacial Journal · doi:10.1177/10556656211001732 · Cited by 4
Kritsaneepaiboon, S., & Goo, H. W. (2021) · Cardiovascular Imaging Asia · doi:10.22468/cvia.2021.00269 · Cited by 4
Optimization and image quality in CT studies: application of DRLs based on clinical indication
Picone, C., Porto, A., Fusco, R., Granata, C., Brunese, M. C., Granata, V., Ottaiano, A., Barretta, M., Caranci, F., Pecori, B., et al. (2025) · Discover Applied Sciences · doi:10.1007/s42452-025-07125-8 · Cited by 3
Abanomy, A. (2024) · Cureus · doi:10.7759/cureus.71072 · Cited by 3
Lāce, E., Mohammadian, R., Āboltiņš, A., Sosārs, D., & Apine, I. (2023) · Acta Radiologica · doi:10.1177/02841851231185347 · Cited by 3
Kumar, M. S., Kumar, C. S., Parmar, R. U., & Velmurugan, J. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac297 · Cited by 3
Priyanka, Kadavigere, R., & Sukumar, S. (2022) · Journal of X-Ray Science and Technology · doi:10.3233/xst-221172 · Cited by 3
Kuwahara, H., Ojima, M., Kawamura, T., Saitou, D., Andou, K., Ariga, E., Hasegawa, K., & Kai, M. (2025) · Tomography · doi:10.3390/tomography11110119 · Cited by 3
Effectiveness of body size stratification for patient exposure optimization in Computed Tomography
Monte, F. D., Sapignoli, S., Cortinovis, A. L., Maggio, A. D., Nardin, M., Pizzirani, E., Scagliori, E., Volpe, A., Paiusco, M., & Roggio, A. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.110804 · Cited by 3
Welarathna, S., Sivakumar, V., & Sarasanandarajah, S. (2024) · Radiation and Environmental Biophysics · doi:10.1007/s00411-024-01080-5 · Cited by 3
Nkubli, F. B., Zira, J. D., Yao, B., Rockson, P., Kenyanya, J., & Nzotta, C. C. (2021) · Radiography · doi:10.1016/j.radi.2021.02.001 · Cited by 3
Inoue, Y., Itoh, H., Koizumi, K., Sekimoto, S., Hata, H., Miyatake, H., Yamane, T., & Mitsui, K. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad6d76 · Cited by 3
Cumulative Radiation Exposure in Covid-19 Patients Admitted to the Intensive Care Unit
Hadid‐Beurrier, L., Cohen, A., Geryes, B. H., Voicu, S., Malissin, I., Deye, N., Mégarbane, B., & Bousson, V. (2022) · Radiation Research · doi:10.1667/rade-21-00203.1 · Cited by 3
Comparative analysis of radiation dose distribution in multi-phase tomography angiography procedures
Elzaki, M. M., Kamal, E., Gareeballah, A., Alrehily, F. A., Osman, H., Hamd, Z. Y., & Khandaker, M. U. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.112860 · Cited by 3
Efthymiou, F. O., Metaxas, V. I., Dimitroukas, C. P., Delis, H., Zikou, K. D., Ntzanis, E. S., Zampakis, P. E., Panayiotakis, G., & Kalogeropoulou, C. P. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/acf582 · Cited by 3
Ito, T. (2025) · Journal of Radiation Protection and Research · doi:10.14407/jrpr.2024.00143 · Cited by 3
Mardfar, S., Ghaziyani, M. F., Mortezazadeh, T., Zamani, H., Rahimiyan, M., & Khezerloo, D. (2024) · Radiation and Environmental Biophysics · doi:10.1007/s00411-024-01074-3 · Cited by 3
Ono, K., & Asada, Y. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01533-1 · Cited by 3
Hamd, Z. Y., Almohammed, H. I., Manssor, E., Bakry, A. H. A., & Gareeballah, A. (2025) · Tomography · doi:10.3390/tomography11060065 · Cited by 3
Assessment of Adult’s Abdominopelvic Computed Tomography Radiation Doses in Amhara Region, Ethiopia
Dellie, S. T., Tesfaw, A. F., & Legesse, T. K. (2022) · Ethiopian Journal of Health Sciences · doi:10.4314/ejhs.v32i6.6 · Cited by 3
Botwe, B. O., Anim-Sampong, S., & Nkansah, J. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/acb5aa · Cited by 3
Saeed, M. K., Abdallah, Y. M. Y., Hakeem, I. Y., & Alqahtani, F. F. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.110990 · Cited by 3
Abdallah, Y. M. Y., & Alamoudi, A. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113085 · Cited by 3
Fulcheri, C. P. L., Sguazzini, O., Parenti, V. D., Scarlattei, M., Baldari, G., Cervati, V., Graziani, T., Ruffini, L., & Ghetti, C. (2026) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncag003 · Cited by 3
Kikuchi, T., Yamamoto, K., Yamagishi, Y., Akashi, T., Hanaoka, S., Yoshikawa, T., Fujii, H., Mori, H., Makimoto, H., & Kohro, T. (2026) · Japanese Journal of Radiology · doi:10.1007/s11604-026-02028-z · Cited by 3
Local Diagnostic Reference Levels for Adult Computed Tomography Urography Exams
Husremović, F., Muharemović, O., Đedović, E., Efendić, A., Mušanović, J., Omerović, R., Osmanović, H., & Busuladžić, M. (2024) · Diagnostics · doi:10.3390/diagnostics14060643 · Cited by 3
Albadarneh, L., Rahman, A. A., Ewaidat, H. A., Lubad, E. A., & Alsaid, A. (2025) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-025-01600-3 · Cited by 3
Niveles de referencia diagnósticos en equipos de radiografía dental en Bogotá, Colombia
Alejo-Martínez, H., Peña-Rodríguez, A., Sevilla-Moreno, A. C., Salazar, E. C., & Jiménez, D. N. P. (2023) · Salud UIS · doi:10.18273/saluduis.55.e:23044 · Cited by 3
Journal of the Belarusian State University. Ecology.
(2022) · Journal of the Belarusian State University Ecology · doi:10.46646/2521-683x/2021-3 · Cited by 3
Murat, H., Kechik, M. M. A., Said, M. A., Saufi, S. I., Zaid, M. H. M., & Karim, M. K. A. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.112986 · Cited by 3
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.