ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 301–400 of 1,000
Assessment of pediatric radiation doses in brain CT procedures
Bawazeer, O. A., Saleem, R., Alhazmi, M., Asiri, N., Mohammed, T., Alsaab, A. A., Algethami, M., Sedayo, A., & Ajlouni, A.-W. (2022) · Radioprotection · doi:10.1051/radiopro/2022027 · Cited by 9
Analysis of a multicentre cloud-based CT dosimetric database: preliminary results
Calderoni, F., Campanaro, F., Colombo, P. E., Campoleoni, M., Mattia, C. D., Rottoli, F., Galetta, G., Zucconi, F., Pola, A., Righini, A., et al. (2019) · European Radiology Experimental · doi:10.1186/s41747-019-0105-6 · Cited by 9
Yurt, A., Özsoykal, İ., Kandemir, R., & Ada, E. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa121 · Cited by 9
Paediatric computed tomography diagnostic reference levels in Africa: A systematic review
Gyan, E., Subaar, C., Edusei, G., & Antwi, L. N. (2024) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.824 · Cited by 9
Ncwane, V. S., Gumede, L., & Wyk, B. V. (2025) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2025.102101 · Cited by 9
CT diagnostic reference levels: are they appropriately computed?
Vanaudenhove, T., Muylem, A. V., Howarth, N., Gevenois, P. A., & Tack, D. (2019) · European Radiology · doi:10.1007/s00330-019-06141-8 · Cited by 9
Zamani, H., Kavousi, N., Masjedi, H., Omidi, R., Yazdi, S. R., Perota, G., Razavi, E., Zare, M. H., & Abedi‐Firouzjah, R. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab093 · Cited by 9
Doses from cervical spine computed tomography (CT) examinations in the UK
Holroyd, J., & Edyvean, S. (2018) · British Journal of Radiology · doi:10.1259/bjr.20170834 · Cited by 9
Semghouli, S., Hamidi, L. E., Aabid, M., & Amaoui, B. (2024) · Radioprotection · doi:10.1051/radiopro/2023041 · Cited by 9
Amalaraj, T., Jeyasugiththan, J., Satharasinghe, D., & Pallewatte, A. S. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/acb1bf · Cited by 9
Karambatsakidou, A., Omar, A., Fransson, A., & Poludniowski, G. G. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.12.008 · Cited by 9
Ribeiro, J. C. D. S., Mendes, J. D. S., & de Sá, L. V. (2022) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13658 · Cited by 9
Sulieman, A., Adam, H., Tamam, N. M., Alkhorayef, M. A., Alhailiy, A. B., Alghamdi, S. S., Elnour, A., Alomair, O. I., Alashban, Y. I., Khandaker, M. U., et al. (2021) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2021.109662 · Cited by 9
AlShurbaji, M., Haout, S. E., Chanchal, A., Dhou, S., & Dalah, E. Z. (2024) · Applied Sciences · doi:10.3390/app14031071 · Cited by 9
Diagnostic reference levels in interventional neuroradiology procedures – a systematic review
Lopes, R., Teles, P., & Santos, J. (2024) · Neuroradiology · doi:10.1007/s00234-024-03445-5 · Cited by 9
Li, X., Hirsch, J. A., Rehani, M. M., Yang, K., Marschall, T. A., & Liu, B. (2021) · British Journal of Radiology · doi:10.1259/bjr.20211108 · Cited by 9
Self-citationHamad, M. S., Attalla, E. M., Amer, H. H., & Fathy, M. M. (2023) · Radiation and Environmental Biophysics · doi:10.1007/s00411-023-01031-6 · Cited by 9
Forbrig, R., Özpeynirci, Y., Fischer, T. D., Trumm, C. G., Liebig, T., & Stahl, R. (2023) · Clinical Neuroradiology · doi:10.1007/s00062-023-01288-w · Cited by 9
Establishing weight-based diagnostic reference levels for neonatal chest X-rays
Gilley, R., David, L. R., Leamy, B., Moloney, D., Moore, N., England, A., Waldron, M., Maher, M. M., & McEntee, M. F. (2023) · Radiography · doi:10.1016/j.radi.2023.05.012 · Cited by 10
Kaasalainen, T. T., Saukko, E., Lindström, O. K., Udd, M., Regnér, S., Saarela, A., Tóth, E., Johansson, G. W., Manninen, A.-L., Grönroos, J., et al. (2024) · Diagnostics · doi:10.3390/diagnostics14060656 · Cited by 9
Clinical diagnostic reference levels in neuroradiology based on clinical indication
Aly, A., Tsapaki, V., Ahmed, A. Z., Own, A. M., Patro, S. N., Naemi, H. A., & Kharita, M. H. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncae113 · Cited by 9
Dalah, E. Z., Alkaabi, M. K., Al-Awadhi, H. M., & Antony, N. A. (2024) · Journal of Imaging · doi:10.3390/jimaging10080188 · Cited by 9
Forbrig, R., Trumm, C. G., Reidler, P., Kunz, W. G., Dimitriadis, K. A., Kellert, L., Rueckel, J., Liebig, T., & Stahl, R. (2024) · Diagnostics · doi:10.3390/diagnostics14242866 · Cited by 9
Assessment of adult diagnostic reference levels for panoramic radiography in Tamil Nadu region
Kumar, A., Jose, A., Govindarajan, K., Devanand, B., & Elango, N. (2019) · Journal of Medical Physics · doi:10.4103/jmp.jmp_77_19 · Cited by 9
ASSESSMENT OF ADULT DIAGNOSTIC REFERENCE LEVELS IN INTRAORAL RADIOGRAPHY IN TAMIL NADU REGION, INDIA
Jose, A., Kumar, A., Govindarajan, K., & Manimaran, P. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa069 · Cited by 9
Alshamrani, K. M., Alkenawi, A., Alghamdi, B. N., Honain, R. H., Alshehri, H. A., Alshatiri, M. O., Mail, N., Subahi, A. E., AlSharif, S., Qurashi, A. A., et al. (2021) · Cureus · doi:10.7759/cureus.15005 · Cited by 9
Opitz, M. K., Alatzides, G. L., Zensen, S., Bos, D., Wetter, A., Guberina, N., Oppong, M. D., Wrede, K. H., Hagenacker, T., Li, Y., et al. (2021) · Clinical Neuroradiology · doi:10.1007/s00062-021-01126-x · Cited by 9
Ishii, H., Chida, K., Inaba, Y., Abe, K., Onodera, S., & Zuguchi, M. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad0a9d · Cited by 9
Li, M., Qu, W., Zhang, D., Zhong, B., Li, Z., Jiang, Z., Ni, G., & Ni, C. (2024) · Tomography · doi:10.3390/tomography10030025 · Cited by 9
Sharma, S., Kulkarni, A., & Akhilesh, P. (2019) · Radiation Protection and Environment · doi:10.4103/rpe.rpe_8_19 · Cited by 9
Abuhaimed, A., & Martin, C. J. (2020) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2020.109202 · Cited by 9
Self-citationSmith, T. B., Heil, J., Frush, D. P., & Samei, E. (2021) · Pediatric Radiology · doi:10.1007/s00247-020-04909-5 · Cited by 9
O’Hora, L., Neville, N., Tuffy, J., Craig, A., O’Brien, K., Sugrue, K., McGarry, M., Duggan, B., & Egan, S. (2023) · European Radiology · doi:10.1007/s00330-023-09992-4 · Cited by 8
Establishment of CT diagnostic reference levels (DRLs) for a Singapore healthcare cluster
Arlany, L., Toh, H. G., Nazir, B., Ng, J. J., Tay, Y. H., Tay, Y. S., Poon, C. J. X., Lee, L., Fum, W. K. S., Lee, E. Y. T., et al. (2022) · Radiography · doi:10.1016/j.radi.2022.11.002 · Cited by 9
Abdulkadir, M. K., Izge, I. Y., Yunusa, G. H., Mohammed, A., & Osman, N. D. (2021) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2021.109380 · Cited by 8
Alkhybari, E. M., Alhulail, A. A., Sulieman, A., Faqeeh, J. M., Albatly, A. A., & Alqarni, A. (2022) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2022.08.011 · Cited by 8
Impact of new X-ray technology reducing patient and staff doses in interventional cardiology
Sánchez, R. M., Vañó-Carruana, E., & Fernández, J. M. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf095 · Cited by 8
Takenaka, M., Rehani, M. M., Hosono, M., Yamazaki, T., Omoto, S., Minaga, K., Kamata, K., Yamao, K., Hayashi, S., Nishida, T., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11061705 · Cited by 8
Self-citationSIZE-SPECIFIC DOSE ESTIMATES IN PEDIATRIC BRAIN CT IN RELATION TO AGE AND WEIGHT
Fujii, K., Inoue, Y., Itoh, H., Sasa, R., Hata, H., & Mitsui, K. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad133 · Cited by 8
Making CT Dose Monitoring Meaningful: Augmenting Dose with Imaging Quality
Alsaihati, N., Ria, F., Solomon, J., Ding, A., Frush, D. P., & Samei, E. (2023) · Tomography · doi:10.3390/tomography9020065 · Cited by 8
Hakme, M., Rizk, C., Francis, Z., & Fares, G. (2023) · Radioprotection · doi:10.1051/radiopro/2023013 · Cited by 8
Alhailiy, A. B., Alkhybari, E. M., Alshuhri, M. S., Al-Othman, A. Y., Hegazi, T. M., Alsuhaimi, M. A., Alghamdi, S., Alenazi, K., Alashban, Y. I., Alghamdi, S. A., et al. (2024) · Diagnostics · doi:10.3390/diagnostics14141523 · Cited by 8
Brambilla, M., Berton, L., Balzano, R. F., Cannillo, B., Carriero, A., Chauvie, S., Gallo, T., Cornacchia, S., Cutaia, C., D’Alessio, A., et al. (2023) · European Radiology · doi:10.1007/s00330-023-10520-7 · Cited by 8
Geryes, B. H., Moalla, S., Etienne, E. D. S., Moussier, A., Pontana, F., Boddaert, N., Pontvianne, V., Dangouloff‐Ros, V., Berteloot, L., Lozach, C., et al. (2025) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2025.11.010 · Cited by 8
General model for estimation of indoor radon concentration dynamics
Dvorzhak, A., Mora, J. C., Real, A., Sàinz, C., & Merino, I. F. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-021-14422-3 · Cited by 8
Ashworth, E., Woods, L., & Cook, J. V. (2021) · British Journal of Radiology · doi:10.1259/bjr.20201269 · Cited by 8
Babikir, E., Al-Mallah, A., Al-Sehlawi, M., Tamam, N. M., & Sulieman, A. (2020) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2020.108888 · Cited by 8
Saeed, M. K. (2021) · Radiological Physics and Technology · doi:10.1007/s12194-020-00598-9 · Cited by 8
Feghali, J. A., Delépierre, J., Ciraj‐Bjelac, O., Dabin, J., Deleu, M., Monte, F. D., Dobric, M. R., Gallagher, A., Hadid‐Beurrier, L., Henry, P., et al. (2021) · Acta Radiologica · doi:10.1177/02841851211061438 · Cited by 8
Talbi, M., Mansouri, M. E., Nhila, O., Tahiri, Z., Eddaoui, K., & Khalis, M. (2022) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2022.03.008 · Cited by 8
Nationwide survey on radiation doses received by patients in nuclear medicine imaging procedures
Skovorodko, K., Komiagienė, R., Maciusovic, M., Gilys, L., Vajauskas, D., Grigonienė, V., Žiliukas, J., Raudonienė, J., & Gricienė, B. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac8202 · Cited by 8
Almujally, A., Alenezi, S. B., Aldosary, K. N., Otayni, A., Sulieman, A., Abdelghani, A. A., Tamam, N. M., Mohtasib, R., Masawi, A., Moftah, B., et al. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110628 · Cited by 8
Park, H., Kim, J. S., Kang, E., Kim, Y., Jo, H., Heo, J.-H., Yang, W., & Yoon, Y. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e20760 · Cited by 8
Farah, J., Pariente, D., Esaki, A., Deleuze, C., Adamsbaum, C., & Franchi‐Abella, S. (2020) · Pediatric Radiology · doi:10.1007/s00247-020-04627-y · Cited by 8
Benderitter, M., Herrera-Reyes, E., Benadjaoud, M. A., Vanhavere, F., Impens, N. R. E. N., Mayerhofer-Sebera, U., Hierath, M., Jourdain, J.-R., Frija, G. G., & Repussard, J. (2021) · Radioprotection · doi:10.1051/radiopro/2021030 · Cited by 8
Niveles de referencia de dosis de radiación para la toma de imágenes en pediatría
Álvarez, L. M. C., Bolaños, J. F. P., Montoya, M. I. P., Londoño, J. F. G., & Arango, M. F. S. (2020) · Revista colombiana de radiología · doi:10.53903/01212095.43 · Cited by 8
Jambi, L. K., Alkhorayef, M. A., Almuwanis, M., Omer, H. B., Alhasan, N., Tài, D. T., Sulieman, A., & Bradley, D. A. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110351 · Cited by 8
Martin, C. J., & Abuhaimed, A. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac85fa · Cited by 8
Self-citationWelarathna, S., Sivakumar, V., Wanninayake, M., & Sarasanandarajah, S. (2022) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13852 · Cited by 8
Weir, A., Schofield, K., & McCurrach, A. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/abcf8b · Cited by 8
Kudo, H., Yoshinaga, S., Li, X., Lei, S., Shouzhi, Z., Sun, Q., Koriyama, C., Akiba, S., & Tokonami, S. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.764201 · Cited by 8
Wong, S., Vigneswaran, G., Maclean, D., Bryant, T., Hacking, N., Maher, B., Somani, B. K., Manoharan, S., Brownlee, E. M., Griffin, S. J., et al. (2021) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2021.12.013 · Cited by 8
Alhujaili, S. F., Alshabibi, A. S., Alafer, F., Alrowaili, Z., Salah, H., Sulieman, A., Subahi, M., Al-Raddadi, K., & Abuzaid, M. (2024) · Diagnostics · doi:10.3390/diagnostics14242882 · Cited by 7
Matsubara, K., Matsunaga, Y., Yanagawa, N., Muramatsu, Y., Ida, Y., Suzuki, S., Akahane, K., & Ishiguchi, T. (2018) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2018_jsrt_74.7.700 · Cited by 7
Inoue, Y., Takahashi, K., Miyatake, H., Nagahara, K., & Iwasaki, R. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac6a89 · Cited by 7
National diagnostic reference levels for digital diagnostic and screening mammography in Uganda
Odongo, D., Musisi, A., Okello, R., Bongomin, F., & Erem, G. (2024) · PLoS ONE · doi:10.1371/journal.pone.0294541 · Cited by 7
Bohang, S. A. M., & Sohaimi, N. (2023) · Malaysian Journal of Medical Sciences · doi:10.21315/mjms2023.30.3.5 · Cited by 7
Amalaraj, T., Satharasinghe, D., Pallewatte, A. S., & Jeyasugiththan, J. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac40e8 · Cited by 7
Marshall, E. L., Rajderkar, D. A., Brown, J. L., Stepusin, E. J., Borrego, D., Duncan, J. R., Sammet, C. L., Munneke, J. R., Kwan, M. L., Miglioretti, D. L., et al. (2019) · Radiation Research · doi:10.1667/rr15445.1 · Cited by 7
Osman, N. D., Abdulkadir, M. K., Shuaib, I. L., & Nasirudin, R. A. (2023) · Radiography · doi:10.1016/j.radi.2023.11.012 · Cited by 7
Peter, Y., Speelman, A. C., & Daries, V. (2020) · Radiography · doi:10.1016/j.radi.2020.07.019 · Cited by 7
Aloufi, K. M., Alhazmi, F. H., Alrehily, F. A., Alraddadi, N. S., Alharbi, A. S., Alamin, A. M., Alraddadi, N. S., Alenezi, A. A., & Hadi, F. H. (2024) · Applied Sciences · doi:10.3390/app14177583 · Cited by 7
Establishment of National Diagnostic Reference Levels 2025 for nuclear medicine in Japan
Abe, K., Baba, S., Etani, R., Fujimto, T., Hosono, M., Iimori, T., Inaki, A., Ishiguro, M., Miyaji, N., Okizaki, A., et al. (2025) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02102-y · Cited by 7
Omojola, A. D., Akpochafor, M. O., Adeneye, S. O., Akala, I. O., & Agboje, A. A. (2021) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-021-00445-w · Cited by 7
Syrgiamiotis, V., Ploussi, A., Rallis, S., Gavra, M. M., Alexopoulou, E., Platoni, K., & EFSTATHOPOULOS, E. P. (2025) · Cureus · doi:10.7759/cureus.85284 · Cited by 7
Sekkat, H., Khallouqi, A., Rhazouani, O. E., Halimi, A., Elmansouri, & Madkouri, Y. (2025) · Radioprotection · doi:10.1051/radiopro/2024024 · Cited by 7
Viry, A., Vitzthum, V., Monnin, P., Bize, J., Rotzinger, D. C., & Racine, D. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.103365 · Cited by 7
Eze, K. C., Uduma, F. U., Omidiji, O. A. T., Ibekwe, N. K., Ahidjo, A., Ibinaiye, P. O., Anas, I., Itanyi, U. D., Igbinedion, B. O.-E., Ogbole, G. I., et al. (2022) · Chinese Journal of Academic Radiology · doi:10.1007/s42058-022-00097-3 · Cited by 7
Srimahachota, S., Krisanachinda, A., Roongsangmanoon, W., Sansanayudh, N., Limpijankit, T., Chandavimol, M., Athisakul, S., Siriyotha, S., & Rehani, M. M. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.02.013 · Cited by 7
Self-citationDIAGNOSTIC REFERENCE LEVELS AND COMPLEXITY INDICES IN INTERVENTIONAL RADIOLOGY
Vosou, M., Spiliοpoulos, S., Palialexis, K., Antonakos, I., & EFSTATHOPOULOS, E. P. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac267 · Cited by 7
Ubeda, C., Vano, E., Pérez, M. D. R., Ramirez, R., Miranda, P., Azcurra, P., de Oliveira, M. V. L., Schelin, H. R., Yagui, A., Khoury, H. J., et al. (2025) · Journal of Radiological Protection · doi:10.1088/1361-6498/ae0650 · Cited by 7
Rizk, C., Chedid, G. A., Salem, C., & Farah, J. (2020) · Neuroradiology · doi:10.1007/s00234-020-02580-z · Cited by 7
Dellie, S. T. (2022) · PubMed Central · doi:10.4314/ejhs.v32i1.3s · Cited by 7
Is it necessary to define new diagnostic reference levels during pandemics like the Covid19-?
Zeinali-Rafsanjani, B., Alavi, A., Lotfi, M., Haseli, S., Saeedi-Moghadam, M., & Moradpour, M. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110739 · Cited by 7
Impact of Electronic Collimation on Reducing Unnecessary Patient Dose in Digital Radiography
Esmaeilian, A. M., Aliakbari, S., Hejazi, P., & Jadidi, M. (2024) · Journal of Biomedical Physics and Engineering · doi:10.31661/jbpe.v0i0.2401-1707 · Cited by 7
Estimation of lifetime attributable cancer risk from abdominal-pelvic pediatric CT procedures
Aloufi, K. M. (2024) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2024.101261 · Cited by 7
Sulieman, A., Salah, H., Mahgoub, O., Alanazi, N., Al-Garni, A., Otayni, A., Tamam, N. M., Alkhorayef, M., & Bradley, D. A. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.112644 · Cited by 7
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Gotanda, T., Hasuo, T., Nishihara, S., Matsuura, K., Kawaji, Y., Yatake, H., Imai, S., Akagawa, T., Tanki, N., & Katsuda, T. (2025) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.70117 · Cited by 7
The unnecessary dose behind cropped radiographs
Guðjónsdóttir, J. (2019) · Radiography Open · doi:10.7577/radopen.3611 · Cited by 7
Four-decade follow-up of a plutonium-contaminated puncture wound treated with Ca-DTPA
Avtandilashvili, M., & Tolmachev, S. Y. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac04b8 · Cited by 7
Radiation dose during catheter ablation in children using a low fluoroscopy frame rate
Riche, M., Monfraix, S., Balduyck, S., Voglimacci-Stephanopoli, Q., Rollin, A., Mondoly, P., Mandel, F., Beneyto, M. M., Delasnerie, H., Derval, N., et al. (2022) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2022.02.001 · Cited by 7
Popkowski, A., Rhodes, S. C., & Hatton, J. F. (2024) · Journal of Endodontics · doi:10.1016/j.joen.2024.02.006 · Cited by 7
Giannone, A., Monte, F. D., Colangelo, M., Salvo, G. D., Fraccaro, C., Sirico, D., Paiusco, M., & Castaldi, B. (2024) · Physica Medica · doi:10.1016/j.ejmp.2024.104487 · Cited by 7
Ngaile, J. E., Msaki, P., Nyanda, P., Muhulo, A., Muhogora, W. E., & Mvungi, R. (2019) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2019.108535 · Cited by 7
Morota, K., Moritake, T., Nagamoto, K., Matsuzaki, S., Nakagami, K., Sun, L., & Kunugita, N. (2020) · Diagnostics · doi:10.3390/diagnostics11010014 · Cited by 7
Anim-Sampong, S., Antwi, W. K., Adomako, J. B., Botwe, B. O., Sarkodie, B. D., & Brakohiapa, E. K. (2023) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2022.12.010 · Cited by 7
The establishment of national diagnostic reference levels for adult SPECT-CT in Saudi Arabia
Al-Qahtani, S. M., Alidasroos, M. A., Alkhybari, E. M., Althomali, M., Alomari, A., Bawazeer, O. A., Hawsawi, H. B., Aamry, A. I., Asiri, J. A., Aloufi, A. A., et al. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/ace452 · Cited by 7
Masuku, R. S. (2023) · Nautical Jurnal Ilmiah Multidisiplin Indonesia · doi:10.55904/nautical.v2i8.593 · Cited by 7
Kwon, T.-E., Park, M. S., Jung, G.-H., Chung, Y., Ha, W.-H., & Jin, Y. W. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz139 · Cited by 7
Age-specific DRLs for pediatric brain CT: A review for exploring the practices in Saudi Arabia
Aljuaid, L. M., Althobaiti, S. F., Althobaiti, A. A., Alsufyani, A. H., Alotaibi, M. H., Elkhader, B. A., Osman, H., Althoibe, M. M., Raafat, B. M., Dahlawi, H. A., et al. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.111664 · Cited by 6
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.