ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
The DOI matches its Crossref record.
Abstract
Abstract –: The International Commission on Radiological Protection (ICRP) first introduced the term ‘diagnostic reference level’ (DRL) in 1996 in Publication 73. The concept was subsequently developed further, and practical guidance was provided in 2001. The DRL has been proven to be an effective tool that aids in optimisation of protection in the medical exposure of patients for diagnostic and interventional procedures. However, with time, it has become evident that additional advice is needed. There are issues related to definitions of the terms used in previous guidance, determination of the values for DRLs, the appropriate interval for re-evaluating and updating these values, appropriate use of DRLs in clinical practice, methods for practical application of DRLs, and application of the DRL concept to newer imaging technologies. This publication is intended as a further source of information and guidance on these issues. Some terminology has been clarified. In addition, this publication recommends quantities for use as DRLs for various imaging modalities, and provides information on the use of DRLs for interventional procedures and in paediatric imaging. It suggests modifications in the conduct of DRL surveys that take advantage of automated reporting of radiation-dose-related quantities, and highlights the importance of including information on DRLs in training programmes for healthcare workers. The target audience for this publication is national, regional, and local authorities; professional societies; and facilities that use ionising radiation for medical purposes, and responsible staff within these facilities. A full set of the Commission’s recommendations is provided.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effective dose is not appropriate for DRLs because the effective dose cannot be measured; it can only be calculated. 1”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [1]
In the citing paper
“They encourage evaluation and possible remedial measures without undermining diagnostic effectiveness.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.2”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
In the citing paper
“To mitigate these issues, Diagnostic Reference Levels (DRLs) have been instituted as an effective mechanism for optimizing radiation dosage, ensuring that patient exposure is minimized to the lowest extent feasible without sacrificing diagnostic integrity.2,3”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [2]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Items 101–200 of 1,000
Alkhybari, E. M., McEntee, M. F., Brennan, P., Willowson, K. P., & Kench, P. L. (2019) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12857 · Cited by 26
Radiation Exposure in Pediatric Interventional Procedures
Ploussi, A., Brountzos, Ε., Rammos, S., Apostolopoulou, S. C., & EFSTATHOPOULOS, E. P. (2021) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02752-7 · Cited by 26
Rehani, M. M., Miller, D. L., & Baliyan, V. (2020) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02703-2 · Cited by 26
Self-citationBerner, K., Hernes, E., Kvassheim, M., Revheim, M.-E. R., Bastiansen, J., Selboe, S., Bakken, C. L., Grønningsæter, S. R., Bruland, Ø. S., Larsen, R. H., et al. (2025) · Journal of Nuclear Medicine · doi:10.2967/jnumed.124.269299 · Cited by 26
National Diagnostic Reference Levels for Nuclear Medicine in Kuwait
Alnaaimi, M., Alduaij, M., Shenawy, F. A., Algaily, M. M., Mohammedzein, T., Alkandri, F. A., Shaban, M. O., & Alenezi, S. A. (2021) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.121.262175 · Cited by 25
Becker, M. D., Butler, P. F., Siam, M., Gress, D. A., Ghesani, M., Harkness, B. A., Yoo, D. C., & Oates, M. E. (2019) · Radiology · doi:10.1148/radiol.2019190623 · Cited by 25
Nam, S., Park, H., Kwon, S., Cho, P.-K., Yoon, Y., Yoon, S.-W., & Kim, J. S. (2022) · Tomography · doi:10.3390/tomography8050203 · Cited by 25
Wachabauer, D., Beyer, T., Ditto, M., Gallowitsch, H. J., Hinterreiter, M., Ibi, B., Malle, P., Mirzaei, S., Smetana, F., Staudenherz, A., et al. (2022) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2021.11.007 · Cited by 25
Hwang, J., Choi, Y. H., Yoon, H. M., Ryu, Y. J., Shin, H. J., Kim, H. G., Lee, S. M., You, S. K., & Park, J. E. (2021) · Korean Journal of Radiology · doi:10.3348/kjr.2020.0890 · Cited by 25
Steffensen, C., Trypis, G., Mander, G., & Munn, Z. (2020) · Radiography · doi:10.1016/j.radi.2020.08.012 · Cited by 25
Järvinen, J., Sierpowska, J., Siiskonen, T., Järvinen, H., Kiviniemi, T., Rissanen, T. T., Matikka, H., Niskanen, E. I., Hurme, S. A. M., Larjava, H. R. S., et al. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz041 · Cited by 25
National Diagnostic Reference Levels for Endovascular Aneurysm Repair and Optimisation Strategies
Rial, R., Vano, E., del Río-Solá, M. L., Fernández, J. M., Sánchez, R. M., Santervás, L. A. C., Bellmunt-Montoya, S., Blanco-Cañibano, E., Joutey, M. E. A., Cañas, E. G., et al. (2020) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2020.08.006 · Cited by 25
on behalf of the European Society of Radiology (ESR), Vano, E., Frija, G. G., Stiller, W., EFSTATHOPOULOS, E. P., Granata, C., Loose, R., Paulo, G., Pekarovič, D., Sjöberg, J., et al. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00859-6 · Cited by 24
Schwarz, B. C., Godwin, W. J., Wayson, M. B., Dewji, S. A., Jokisch, D. W., Lee, C., & Bolch, W. E. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abc708 · Cited by 24
Xie, T., & Zaidi, H. (2019) · European Radiology · doi:10.1007/s00330-019-06296-4 · Cited by 23
Radiation exposure of patients during endourological procedures: IAEA-SEGUR study
Vassileva, J., Zagórska, A., Bašić, D., Karagiannis, A., Petkova, K., Sabuncu, K., Saltirov, I., Sarıca, K., Skolarikos, A. A., Ставридис, С., et al. (2020) · Journal of Radiological Protection · doi:10.1088/1361-6498/abc351 · Cited by 24
Patient dose in angiographic interventional procedures: A multicentre study in Italy
Isoardi, P., D’Ercole, L., Cavallari, M., Gianusso, L., Pini, S., Giordano, C., Angelini, L., Colombo, P. E., Canne, S. D., Vecchio, A. D., et al. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.06.008 · Cited by 23
Wachabauer, D., Röthlin, F., Moshammer, H. M., & Homolka, P. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.02.015 · Cited by 23
Al-Othman, A. Y., Al-Sharydah, A. M., Abuelhia, E., Mohtasib, R., Dahmash, A. B., Hegazi, T. M., Tajaldeen, A. A., Al-Shehri, S. S., Al-Malki, F. M., & Alghamdi, S. S. (2022) · Applied Sciences · doi:10.3390/app122211504 · Cited by 23
Percutaneous screw fixation of pelvic bone metastases using cone-beam computed tomography navigation
Cornélis, F., Razakamanantsoa, L., Ammar, M. B., Najdawi, M., Mouhadi, S. E., Gardavaud, F., & Barral, M. (2022) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.01.002 · Cited by 23
Norsuddin, N. M., Segar, S., Ravintaran, R., Zain, N. M., & Karim, M. K. A. (2022) · Healthcare · doi:10.3390/healthcare10101917 · Cited by 23
JCS 2021 Guideline on Radiation Safety in Cardiology
Kozuma, K., Chikamori, T., Hashimoto, J., Honye, J., Ikeda, T., Ishiwata, S., Kato, M., Kondo, H., Matsubara, K., Matsumoto, K., et al. (2022) · Circulation Journal · doi:10.1253/circj.cj-21-0379 · Cited by 22
Smith‐Bindman, R., Kang, T., Chu, P., Wang, Y., Stewart, C., Das, M., Duong, P.-A. T., Cervantes, L. F., Lamba, R., Lee, R. K., et al. (2023) · European Radiology · doi:10.1007/s00330-023-10076-6 · Cited by 22
Witkowska, A., Petre, E. N., Moussa, A. M., Santos, E., Sarkar, D., Lis, E., & Cornélis, F. (2023) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2023.08.040 · Cited by 22
Patient dose reference levels in surgery: a multicenter study
Greffier, J., Étard, C., Marès, O., Pereira, F., Defez, D., Duverger, C., Branchereau, P., Beregi, J. P., Coulomb, R., & Larbi, A. (2018) · European Radiology · doi:10.1007/s00330-018-5600-2 · Cited by 22
Seguridad y Protección Radiológica en Procedimientos Imagenológicos Dentales
Ubeda, C., Nocetti, D., & Aragón, M. (2018) · International journal of odontostomatology · doi:10.4067/s0718-381x2018000300246 · Cited by 22
A Benchmark for automatic noise measurement in clinical computed tomography
Ahmad, M. U., Jacobsen, M. C., Thomas, M. A., Chen, H., Layman, R. R., & Jones, A. K. (2020) · Medical Physics · doi:10.1002/mp.14635 · Cited by 22
Faj, D., Edyvean, S., Lajunen, A., Katukhov, A., & Vassileva, J. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.102565 · Cited by 21
Radiation Dose Management in Computed Tomography: Introduction to the Practice at a Single Facility
Inoue, Y. (2023) · Tomography · doi:10.3390/tomography9030078 · Cited by 21
Martin, C. J. (2020) · Annals of the ICRP · doi:10.1177/0146645320927849 · Cited by 21
Self-citationRadiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables
Inoue, Y., Itoh, H., Waga, A., Sasa, R., & Mitsui, K. (2022) · Tomography · doi:10.3390/tomography8020079 · Cited by 22
Almén, A., Guðjónsdóttir, J., Heimland, N., Højgaard, B., Waltenburg, H., & Widmark, A. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.05.035 · Cited by 21
Lechner, J., Zimmermann, B., Schmidt, M., & von Baehr, V. (2020) · Clinical Cosmetic and Investigational Dentistry · doi:10.2147/ccide.s247345 · Cited by 21
Junda, M., Muller, H., & Friedrich-Nel, H. (2021) · Health SA Gesondheid · doi:10.4102/hsag.v26i0.1622 · Cited by 21
DOSE BENCHMARKS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY EXAMINATION IN NIGERIA
Ekpo, E. U., Adejoh, T., & Erim, A. E. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz036 · Cited by 20
Satharasinghe, D., Jeyasugiththan, J., Wanninayake, W. M. N. M. B., Pallewatte, A. S., & Samarasinghe, R. A. N. K. K. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.09.004 · Cited by 20
Opitz, M. K., Zenk, C., Zensen, S., Bos, D., Li, Y., Styczen, H., Oppong, M. D., Jabbarli, R., Hagenacker, T., Forsting, M., et al. (2022) · Neuroradiology · doi:10.1007/s00234-022-03092-8 · Cited by 20
Ria, F., D’Ercole, L., Origgi, D., Paruccini, N., Pierotti, L., Rampado, O., Rossetti, V., Strocchi, S., Torresin, A., Pierotti, L., et al. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01155-1 · Cited by 20
Miller, D. L. (2020) · Medical Physics · doi:10.1002/mp.13990 · Cited by 20
Self-citationPrabsattroo, T., Wachirasirikul, K., Tansangworn, P., Punikhom, P., & Sudchai, W. (2023) · Journal of Imaging · doi:10.3390/jimaging9120264 · Cited by 20
Ubeda, C., Vano, E., Salazar, L., Retana, Santos, F. A. V. G., Gutierrez, R., & Manterola, C. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aa9c09 · Cited by 20
Weyland, C. S., Şeker, F., Potreck, A., Hametner, C., Ringleb, P. A., Möhlenbruch, M. A., Bendszus, M., & Pfaff, J. A. R. (2020) · European Radiology · doi:10.1007/s00330-020-06837-2 · Cited by 19
Local diagnostic reference levels for paediatric non-cardiac interventional radiology procedures
Morcillo, A. B., Alejo, L., Huerga, C., Bayón, J., Obesso, A., Corredoira, E., Novo, J. R., Hernández, T., Ponce, M. D., Fernández, L., et al. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.03.001 · Cited by 19
Advanced Computational Methods for Radiation Dose Optimization in CT
Rao, S., Sharan, K., Chandraguthi, S. G., Dsouza, R. N., David, L. R., Ravichandran, S., Mustapha, M. T., Shettigar, D., Uzun, B., Kadavigere, R., et al. (2024) · Diagnostics · doi:10.3390/diagnostics14090921 · Cited by 19
Awad, M. F., Karout, L., Arnous, G., Rawashdeh, M. A., Hneiny, L., & Saade, C. (2020) · Journal of Radiological Protection · doi:10.1088/1361-6498/ab826f · Cited by 19
Hadid‐Beurrier, L., Dabli, D., Royer, B., Demonchy, M., & Roy, J. L. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.05.013 · Cited by 19
Retrospective study of patients radiation dose during cardiac catheterization procedures
Osei, B., Xu, L., Johnston, A., Darko, S., Darko, J., & Osei, E. K. (2019) · British Journal of Radiology · doi:10.1259/bjr.20181021 · Cited by 19
Kumsa, M. J., Nguse, T. M., Ambessa, H. B., Gele, T. T., Fantaye, W. G., & Dellie, S. T. (2023) · BMC Medical Imaging · doi:10.1186/s12880-023-00963-1 · Cited by 18
Radiation Protection among South African Diagnostic Radiographers—A Mixed Method Study
Lewis, S., Downing, C., & Hayre, C. M. (2023) · Health Physics · doi:10.1097/hp.0000000000001655 · Cited by 18
ESTIMATION OF ENTRANCE SURFACE AIR KERMA IN DIGITAL RADIOGRAPHIC EXAMINATIONS
Kaushik, C., Sandhu, I. S., Srivastava, A. K., & Chitkara, M. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab018 · Cited by 18
Naik, S., Varghese, A. P., Andrabi, S. A. U. H., Tivaskar, S. P., Luharia, A. A., & Mishra, G. (2024) · Cureus · doi:10.7759/cureus.66198 · Cited by 18
National reference levels of CT procedures dedicated for treatment planning in radiation oncology
Božanić, A., Šegota, D., Debeljuh, D. D., Kolacio, M. Š., Radojčić, Đ. S., Ružić, K., Budanec, M., Kasabašić, M., Hrepić, D., Zujić, P. V., et al. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.03.001 · Cited by 18
Provision of Italian diagnostic reference levels for diagnostic and interventional radiology
Compagnone, G., Padovani, R., D’Ercole, L., Orlacchio, A., Bernardi, G., D’Avanzo, M. A., Grande, S., Palma, A., Campanella, F., & Rosi, A. (2020) · La radiologia medica · doi:10.1007/s11547-020-01165-3 · Cited by 18
Self-citationEffective radiation doses in pediatric PET/CT examinations: Pilot study
Alkhorayef, M. A. (2020) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2020.109412 · Cited by 18
Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu
Jose, A., Kumar, A., Govindarajan, K., & Sharma, S. D. (2022) · Journal of Medical Physics · doi:10.4103/jmp.jmp_119_21 · Cited by 18
Jasieniak, J., Kuchcińska, A., Podgórska, J., & Cieszanowski, A. (2023) · Polish Journal of Radiology · doi:10.5114/pjr.2023.124376 · Cited by 17
Hasan, N., Rizk, C., & Babikir, E. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110147 · Cited by 17
Recurrent medical imaging exposures for the care of patients: one way forward
Frush, D. P., Vassileva, J., Brambilla, M., Mahesh, M., Rehani, M. M., Samei, E., Applegate, K. E., Bourland, J. D., Ciraj‐Bjelac, O., Dahlstrom, D., et al. (2024) · European Radiology · doi:10.1007/s00330-024-10659-x · Cited by 17
Self-citationAlbahiti, S. K., Barnawi, R. A., Alsafi, K., Khafaji, M. A., Aljondi, R., Alghamdi, S. S., Awan, Z. A., Sulieman, A., Jafer, M., Tamam, N. M., et al. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110477 · Cited by 17
Nishida, T., Hayashi, S., Takenaka, M., Hosono, M., Kogure, H., Hasatani, K., Yamaguchi, S., Maruyama, H., Doyama, H., Ihara, H., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033604 · Cited by 17
Patient dose in CT angiography examinations: An institutional survey
Metaxas, V. I., Dimitroukas, C. P., Efthymiou, F. O., Zampakis, P. E., Panayiotakis, G., & Kalogeropoulou, C. P. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110083 · Cited by 17
Abuzaid, M. (2025) · Diagnostics · doi:10.3390/diagnostics15060740 · Cited by 17
LOW BMI PATIENT DOSE IN DIGITAL RADIOGRAPHY
Efthymiou, F. O., Metaxas, V. I., Dimitroukas, C. P., & Panayiotakis, G. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa007 · Cited by 17
Vano, E., Sánchez, R. M., Fernández, J. M., & Ten, J. I. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.11.013 · Cited by 17
Typical doses and typical values for fluoroscopic diagnostic and interventional procedures
Tristram, J., Steuwe, A., Kröpil, F., Thomas, C. K., Rubbert, C., Antoch, G., & Boos, J. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac5294 · Cited by 17
Almohammed, H. I., Elshami, W., Hamd, Z. Y., & Abuzaid, M. (2024) · BMC Health Services Research · doi:10.1186/s12913-024-11369-2 · Cited by 17
Beganović, A., Ciraj‐Bjelac, O., Dyakov, I., Gershan, V., Kralik, I., Milatović, A., Šalát, D., Stepanyan, K., Vladimirov, A., & Vassileva, J. (2019) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20190157 · Cited by 17
Takenaka, M., Hosono, M., Rehani, M. M., Chiba, Y., Ishikawa, R., Okamoto, A., Yamazaki, T., Nakai, A., Omoto, S., Minaga, K., et al. (2021) · Digestive Endoscopy · doi:10.1111/den.14060 · Cited by 17
Self-citationRadaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R. (2023) · Polish Journal of Medical Physics and Engineering · doi:10.2478/pjmpe-2023-0003 · Cited by 16
Relationships of radiation dose indices with body size indices in adult body computed tomography
Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K. (2023) · Tomography · doi:10.3390/tomography9040110 · Cited by 16
Simplified size adjusted dose reference levels for adult CT examinations: A regional study
Moghadam, N., Lecomte, R., Mercure, S., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109861 · Cited by 16
Self-citationKahraman, G., Haberal, K. M., & Ağıldere, A. M. (2024) · Diagnostic and Interventional Radiology · doi:10.4274/dir.2023.232265 · Cited by 16
Bos, D., Wang, Y., Stewart, C., Chu, P., Luong, J., Haubold, J., Schröer, B., Zensen, S., Duong, P.-A. T., Schindera, S. T., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11724-9 · Cited by 16
Patient dose audit in common CT examinations
Dimitroukas, C. P., Metaxas, V. I., Efthymiou, F. O., Kalogeropoulou, C. P., Zampakis, P. E., & Panayiotakis, G. (2021) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2021.109924 · Cited by 16
Hayashi, S., Nishida, T., Kuriki, S., Chang, L.-S., Aochi, K., Meren, E., Sakamoto, T., Tomita, R., Higaki, Y., Osugi, N., et al. (2020) · Endoscopy International Open · doi:10.1055/a-1287-9066 · Cited by 16
Hayashi, S., Takenaka, M., Hosono, M., & Nishida, T. (2018) · World Journal of Clinical Cases · doi:10.12998/wjcc.v6.i16.1087 · Cited by 16
The system of radiological protection and the UN sustainable development goals
Rühm, W., Applegate, K. E., Bochud, F. O., Laurier, D., Schneider, T., Bouffler, S. D., Cho, K.-W., Clement, C. H., German, O., Hirth, G., et al. (2024) · Radiation and Environmental Biophysics · doi:10.1007/s00411-024-01089-w · Cited by 16
Diagnostic reference levels and optimisation in radiology: where do we go from here?
Martin, C. J., & Vano, E. (2017) · Journal of Radiological Protection · doi:10.1088/1361-6498/aa9cfd · Cited by 16
Self-citationRao, S., Sharan, K., Sukumar, S., Chandraguthi, S. G., Dsouza, R. N., David, L. R., Ravichandran, S., Uzun, B., Kadavigere, R., & Ozsahin, D. U. (2023) · Diagnostics · doi:10.3390/diagnostics13061072 · Cited by 16
Bernardo, M. O., Karout, L., Morgado, F. E. F., Ebrahimian, S., Santos, A. S., Amorim, C., Filho, H. M. L., Moscatelli, A., Muglia, V. F., Schroeder, H., et al. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.111191 · Cited by 16
Tzanis, E., Ioannou, C. V., Tsetis, D. K., Lioudaki, S., Ματθαίου, Ν., & Damilakis, J. E. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.04.015 · Cited by 16
Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco
Talbi, M., Tahiri, Z., Eddaoui, K., Mansouri, M. E., Nhila, O., Benmessaoud, M., Ouaggou, I. A., Chakir, E. M., Sebihi, R., & Khalis, M. (2022) · Radioprotection · doi:10.1051/radiopro/2022008 · Cited by 16
National Diagnostic Reference Levels for Nuclear Medicine in Qatar
Fayad, H. J., Ahmed, S., khatib, A. E., Ghujeh, A., Aly, A., Kharita, M. H., & AlNaemi, H. (2022) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.122.264415 · Cited by 16
Aristizábal, A. M., Gutiérrez, J., Ramirez, E., Mejía‐Quiñones, V., Ubeda, C., Mosquera, W. F., & Mosquera, W. (2023) · Children · doi:10.3390/children10101588 · Cited by 16
Bärenfänger, F., Block, A., & Rohde, S. (2019) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-0924-5945 · Cited by 16
Local Diagnostic Reference Levels in Interventional Radiology
Ou-Saada, I., Boujemaa, S., Campoleoni, M., Brambilla, R., & Bentayeb, F. (2020) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2020.02.004 · Cited by 16
Primary operator radiation dose in the cardiac catheter laboratory
Crowhurst, J. A., Whitby, M., Aroney, N. P., Dautov, R. F., Walters, D., & Raffel, O. (2020) · British Journal of Radiology · doi:10.1259/bjr.20200018 · Cited by 16
Tan, W. S., Foley, S., & Ryan, M. L. (2023) · Radiography · doi:10.1016/j.radi.2023.05.003 · Cited by 15
Sebelego, I., Acho, S., van der Merwe, B., & Rae, W. I. D. (2023) · Radiography · doi:10.1016/j.radi.2023.07.011 · Cited by 15
Vano, E., Loose, R., Frija, G. G., Paulo, G., EFSTATHOPOULOS, E. P., Granata, C., Corridori, R., Torresin, A., Andersson, J., Tsapaki, V., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08675-w · Cited by 15
Evaluation of radiation dose in lumbar spine computed tomography in a single Moroccan center
Mansouri, M. E., Choukri, A., Nhila, O., & Talbi, M. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110089 · Cited by 15
Benmessaoud, M., Housni, A., Elmabrouki, M., Essasnaoui, F., Sadiki, N., Dadouch, A., & Labzour, A. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab095 · Cited by 15
An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries
Malik, M. M. U. D., Alqahtani, M. M., Hadadi, I., AlQhtani, A. G. M., & Alqarni, A. (2024) · Diagnostics · doi:10.3390/diagnostics14151585 · Cited by 17
Establishing Diagnostic Reference Levels for Paediatric CT Imaging: A Multi-Centre Study
Bouchareb, Y., Kharusi, M. A., Maqbali, A. A., Maimani, A. A., Al-Maskari, H., Sirasanagandla, S. R., Jabri, A. A., Kindi, F. A. A., Shabibi, S. A., & Baawain, S. (2025) · Healthcare · doi:10.3390/healthcare13141728 · Cited by 15
Current status of diagnostic reference levels in interventional cardiology
Sánchez, R. M., Siiskonen, T., & Vano, E. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/aca2b3 · Cited by 15
National UK Survey of Radiation Doses During Endovascular Aortic Interventions
Tsitsiou, Y., Velan, B., Ross, R., Lakshminarayan, R., Rogers, A., Hamady, M., RADEVAIR, Khan, L., Krishnan, A., Hennessy, M., et al. (2023) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-023-03592-x · Cited by 15
Self-citationEstimating Local Diagnostic Reference Levels for Mammography in Dubai
Noor, K. A., Norsuddin, N. M., Karim, M. K. A., Isa, I. N. C., & Alshamsi, W. (2023) · Diagnostics · doi:10.3390/diagnostics14010008 · Cited by 15
Radiation protection knowledge and practices among Moroccan dentists: A cross-sectional study
Elmorabit, N., Obtel, M., Azougagh, M., & Ennibi, O. K. (2024) · Radiation Medicine and Protection · doi:10.1016/j.radmp.2024.03.001 · Cited by 15
Kim, J. S., Lee, B., Ryu, D. R., Chun, K. J., Choi, H.-H., Roh, Y., Kwon, S., & Cho, B. R. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa016 · Cited by 15
Radiation risk for patients undergoing cardiac computed tomography examinations
Alkhorayef, M. A., Sulieman, A., Alzahrani, K., Abuzaid, M., Alomair, O. I., Almuwanis, M., Alghamdi, S. S., Tamam, N. M., & Bradley, D. A. (2020) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2020.109520 · Cited by 15
Metadata
- Authors
- Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A.
- Venue
- Annals of the ICRP
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 46
- Issue
- 1
- Pages
- 1-144
- ISSN
- 0146-6453 (ISSN-L)
- 1872-969X
- OpenAlex
- W2765599824
- Cited by
- 1,043
- References
- 0
- Citations by year
- 2026: 155 · 2025: 173 · 2024: 137 · 2023: 136 · 2022: 110 · 2021: 124 · 2020: 108 · 2019: 65 · 2018: 31 · 2017: 4
- FWCI
- 43.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of the ICRP (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, diagnostic imaging, radiation protection, patient radiation dose, dose optimization, interventional procedures, pediatric radiology, health professions education
- MeSH terms
- Radiation Exposure, Diagnostic Imaging, Humans, Radiation Dosage, Radiation Protection, Reference Values, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.