Sensitivity of the Human Circadian Pacemaker to Moderately Bright Light
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The aim of the present study was to evaluate the sensitivity of the human circadian pacemaker to the resetting effect of moderately bright light (∼1260 lux), and to assess the direct effect of such light exposure by comparison to a control group of subjects undergoing the same behavioral manipulations but with a similarly timed exposure to darkness instead of light. Endogenous circadian phase and amplitude were assessed in dim light (∼10-15 lux) before and after two consecutive series of three 5-hr exposures to ∼1260 lux or to darkness (∼0.03 lux) in two different groups of young healthy men, using the constant-routine technique. The light or darkness exposure was centered 1.5 hr after the initial fitted endogenous temperature minimum and 12 hr opposite the newly scheduled midpoint of the sleep episode, in order to induce a phase advance in the light-exposed subjects. The phase of the endogenous circadian pacemaker was assessed by a dual-harmonic regression model from core body temperature recorded every minute during constant routines. Urinary volume was measured at each micturition, subjective alertness every 20 min, and cognitive performance hourly. The endogenous circadian phase shifted to a significantly earlier time after each series of light exposures in the treatment group than it did in the control group (two-way analysis of variance for repeated measures: F = 67.91, p = 0.0001). The analysis of circadian curves of urine production, subjective alertness, and cognitive performance scores revealed that all variables maintained stable temporal relationships with the endogenous circadian temperature minimum—an indication that these rhythms shifted in the same direction and by an equivalent amount. Despite comparable behavioral schedules, including the timing of bedrest/sleep and social contacts, circadian temperature rhythm of control subjects free-ran under dim light conditions, indicating that moderately bright light exerted a direct biological effect on the human circadian pacemaker in the treatment group. The present study also demonstrated that light of ∼1260 lux (which is of substantially lower intensity that the ∼7000-12,000 lux used in prior experiments) produces robust phase advances of the endogenous circadian temperature rhythm, which has been shown to be an accurate marker of the output of the circadian pacemaker (Czeisler et al., 1989). These results support the hypothesis that the phase-shifting effect of light on the human circadian pacemaker has a strongly nonlinear relationship to illuminance levels, such that it is preserved despite marked reductions in light intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Suppresses Melatonin Secretion in Humans
Lewy, A. J., Wehr, T. A., Goodwin, F. K., Newsome, D. A., & Markey, S. P. (1980) · Science · doi:10.1126/science.7434030 · Cited by 1,913
Bright Light Induction of Strong (Type 0) Resetting of the Human Circadian Pacemaker
Czeisler, C. A., Kronauer, R. E., Allan, J. S., Duffy, J. F., Jewett, M. E., Brown, E. N., & Ronda, J. M. (1989) · Science · doi:10.1126/science.2734611 · Cited by 946
Self-citationBright light resets the human circadian pacemaker independent of the timing of the sleep-wake cycle
Czeisler, C. A., Allan, J. S., Strogatz, S. H., Ronda, J. M., Sánchez, R., Ríos, C. D., Freitag, W. O., Richardson, G. S., & Kronauer, R. E. (1986) · Science · doi:10.1126/science.3726555 · Cited by 770
Human Melatonin Suppression by Light is Intensity Dependent
Mclntyre, I. M., Norman, T. R., Burrows, G. D., & Armstrong, S. M. (1989) · Journal of Pineal Research · doi:10.1111/j.1600-079x.1989.tb00412.x · Cited by 389 · cited 2×
“, 1991); in the eclosion rate of Drosophila pseudoobscura (Chandrashekaran and Loher, 1969); in the flight activity of the bat Hipposideros speoris (Joshi and Chandrashekaran, 1985); in the locomotor activity of the Syrian hamster Mesocricetus auratus (Takahashi et al., 1984); and in the core body temperature rhythm o…”
BackgroundAdaptation to abrupt time shifts of the oscillator(s) controlling human circadian rhythms.
Mills, J. N., Minors, D. S., & Waterhouse, J. M. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012582 · Cited by 285
Brainard, G. C., Lewy, A. J., Menaker, M., Fredrickson, R. H., Miller, L. S., Weleber, R. G., Cassone, V., & Hudson, D. (1988) · Brain Research · doi:10.1016/0006-8993(88)90820-7 · Cited by 233
Cited by
Zeitzer, J. M., Dijk, D., Kronauer, R. E., Brown, E. N., & Czeisler, C. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00695.x · Cited by 1,175
“1), during a 9 day protocol (for screening procedures and more extensive protocol details, refer to Boivin et al. 1994 and Duffy et al. 1996).”
MethodSelf-citationDose-response relationships for resetting of human circadian clock by light
Boivin, D. B., Duffy, J. F., Kronauer, R. E., & Czeisler, C. A. (1996) · Nature · doi:10.1038/379540a0 · Cited by 559
Self-citationEffect of Light on Human Circadian Physiology
Duffy, J. F., & Czeisler, C. A. (2009) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2009.01.004 · Cited by 472
Self-citationDuffy, J. F., Dijk, D.-J., Hall, E. F., & Czeisler, C. A. (1999) · Journal of Investigative Medicine · doi:10.1177/108155899904700310 · Cited by 430
Self-citationSocial influences on mammalian circadian rhythms: animal and human studies
Mistlberger, R. E., & Skene, D. J. (2004) · Biological Reviews · doi:10.1017/s1464793103006353 · Cited by 404
CIRCADIAN RHYTHMS: Basic Neurobiology and Clinical Applications
Moore MD, R. Y. (1997) · Annual Review of Medicine · doi:10.1146/annurev.med.48.1.253 · Cited by 400
Complex Interaction of the Sleep-Wake Cycle and Circadian Phase Modulates Mood in Healthy Subjects
Boivin, D. B. (1997) · Archives of General Psychiatry · doi:10.1001/archpsyc.1997.01830140055010 · Cited by 378
Self-citationLight Treatment for Sleep Disorders: Consensus Report: VI. Shift Work
Eastman, C. I., Boulos, Z., Terman, M., Campbell, S. S., Dijk, D.-J., & Lewy, A. J. (1995) · Journal of Biological Rhythms · doi:10.1177/074873049501000208 · Cited by 271
Nonphotic Entrainment in Humans?
Mistlberger, R. E., & Skene, D. J. (2005) · Journal of Biological Rhythms · doi:10.1177/0748730405277982 · Cited by 267
Effects of circadian disruption on the cardiometabolic system
Rüger, M., & Scheer, F. A. J. L. (2009) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-009-9122-8 · Cited by 232
Harper, D. G., Stopa, E. G., McKee, A. C., Satlin, A., Harlan, P. C., Goldstein, R., & Volicer, L. (2001) · Archives of General Psychiatry · doi:10.1001/archpsyc.58.4.353 · Cited by 230
“These patients also were studied without the benefit of a constant routine.(56) A constant routine protocol would allow for more precise quantification of endogenous circadian phase and amplitude of corebody temperature.”
BackgroundInteractive Mathematical Models of Subjective Alertness and Cognitive Throughput in Humans
Jewett, M. E., & Kronauer, R. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129000920 · Cited by 211
Self-citationDevelopment and Evaluation of the Sleep Treatment and Education Program for Students (STEPS)
Brown, F. C., Buboltz Jr., W. C., & Soper, B. (2006) · Journal of American College Health · doi:10.3200/jach.54.4.231-237 · Cited by 207
Sleep-Wake as a Biological Rhythm
Lavie, P. (2001) · Annual Review of Psychology · doi:10.1146/annurev.psych.52.1.277 · Cited by 185
Dijk, D.-J., Duffy, J. F., Silva, E. J., Shanahan, T. L., Boivin, D. B., & Czeisler, C. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030037 · Cited by 170
“This corroborates previous findings [39] [8] [25,40] and indicates that all these rhythms are driven by the same lightsensitive pacemaker, presumably the SCN.”
ResultSelf-citationMood and the circadian system: investigation of a circadian component in positive affect
Murray, G., Allen, N. B., & Trinder, J. (2002) · Chronobiology International · doi:10.1081/cbi-120015956 · Cited by 167
“Boivin et al.([29]) have used this method in finding that alertness shifts in parallel with core body temperature under various light manipulations.”
MethodAtkinson, G., Edwards, B., Reilly, T., & Waterhouse, J. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0361-z · Cited by 167
“Only within the last 20 years has it emerged that the environmental light–dark cycle is actually the key entrainment signal of human circadian rhythms (see, for example, Boivin et al. 1994 ).”
BackgroundThe Effect of Light on the Human Circadian Pacemaker
Czeisler, C. A. (2007) · Novartis Foundation Symposia · doi:10.1002/9780470514597.ch14 · Cited by 164
Self-citationDynamic resetting of the human circadian pacemaker by intermittent bright light
Rimmer, D. W., Boivin, D. B., Shanahan, T. L., Kronauer, R. E., Duffy, J. F., & Czeisler, C. A. (2000) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2000.279.5.r1574 · Cited by 139
Self-citationJames, F. O., Cermakian, N., & Boivin, D. B. (2007) · Sleep · doi:10.1093/sleep/30.11.1427 · Cited by 135
Self-citationEdwards, B. J., Reilly, T., & Waterhouse, J. (2009) · Biological Rhythm Research · doi:10.1080/09291010802067072 · Cited by 31
Metadata
- Authors
- Boivin, D. B., Duffy, J. F., Kronauer, R. E., & Czeisler, C. A.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1994-12
- Volume
- 9
- Issue
- 3-4
- Pages
- 315-331
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2003354740
- Cited by
- 91
- References
- 6
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.