REVIEW ■ : Prospects for a Visual Prosthesis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Diseases of the retina and optic nerve are common causes of irreversible blindness. Given the lack of effective treatments, several laboratories are utilizing microelectronic technology to develop either a cortical or retinal prosthesis. Each strategy offers certain advantages, but both face numerous and formidable chal lenges. Consequently, a clinically useful device of either type is still conceptual. The technological means to build prostheses are available, but the ultimate obstacle is the integration of the technology with the brain. This article reviews achievements of the ongoing efforts and focuses on our project to develop a retinal prosthesis. NEUROSCIENTIST 3:251-262, 1997
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“ments (5) demonstrated that: 1) current delivered to the visual cortex evoked perceptions of bright spots of light called phosphenes, 2) multiple spots of light could be perceived simultaneously following multiple points of stimulation, and 3) there was a perceptual alignment that roughly correlated with the then-know…”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299
“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253 · cited 1×
“ments (5) demonstrated that: 1) current delivered to the visual cortex evoked perceptions of bright spots of light called phosphenes, 2) multiple spots of light could be perceived simultaneously following multiple points of stimulation, and 3) there was a perceptual alignment that roughly correlated with the then-know…”
Background
Cited by
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
“Several research groups have investigated various aspects of retinal prostheses, ranging from electrical stimulation of retinal neurons to surgical implantation methods (Chow & Chow, 1997; Eckmiller, 1997; Humayun, 2001; Rizzo & Wyatt, 1997; Zrenner et al., 1997).”
BackgroundWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Age-Related Macular Degeneration
Fine, S. L., Berger, J. W., Maguire, M. G., & Ho, A. C. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420707 · Cited by 418
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Whether this could result in the atrophy of the retinal tissues around the implant area in the long term is under debate (Peachey and Chow, 1999; Rizzo and Wyatt, 1997; Sailer et al., 2007).”
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Demonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195
Multi-electrode stimulation and recording in the isolated retina
Grumet, A. E., Wyatt, J. L., & Rizzo, J. F. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00246-6 · Cited by 167
Self-citationBiostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Sommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
“Visual prostheses for the blind are currently being developed by several research groups (Chow & Chow, 1997; Dobelle, 2000; Humayun, 2001; Normann, Maynard, Rousche, & Warren, 1999; Rizzo & Wyatt, 1997; Veraart et al., 1998; Zrenner, 2002).”
Simulation of artificial vision: I. Eccentric reading of isolated words, and perceptual learning
Sommerhalder, J., Oueghlani, E., Bagnoud, M., Leonards, U., Safran, A. B., & Pelizzone, M. (2003) · Vision Research · doi:10.1016/s0042-6989(02)00481-9 · Cited by 111
“If other systems using an external camera to capture the stimuli are considered, such as those envisioned in the projects of Humayun et al. (1999) or Rizzo and Wyatt (1997), the transmitting hardware could possibly include remapping routines.”
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Self-citation
Metadata
- Authors
- Rizzo, J. F., & Wyatt, J.
- Venue
- The Neuroscientist
- Publisher
- SAGE Publications
- Published
- 1997-07
- Volume
- 3
- Issue
- 4
- Pages
- 251-262
- ISSN
- 1073-8584 (ISSN-L)
- 1089-4098
- OpenAlex
- W2063413975
- Cited by
- 114
- References
- 5
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.