A review of green systems within the indoor environment
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
This paper reviews the state of art of vegetation systems and their effect on the indoor environmental quality (IEQ), based on scientific studies from the past 30 years. Some studies have shown that biophilic workspaces and interaction with plants may change human attitudes, behaviours, improve productivity and the overall well-being. Evapotranspiration from plants helps lowering the temperature around the planting environment and this can be utilised for air cooling and humidity control. Also, indoor greenery can be used to reduce sound levels as a passive acoustic insulation system. Living wall systems in combination with biofiltration are emerging technologies to provide beneficial effects on improvement of indoor comfort. Several studies have indicated that green systems may improve indoor air quality and that they have different pathways for pollutant removal of volatile organic compounds. The plant root zone in potted plants may be an effective area for removing volatile organic compounds under controlled conditions. In conclusion, the full capacity of plants in real-life settings will need to be clarified to establish the true pollutant-removal mechanisms and the general effect on IEQ. The effects of green systems in combination with mechanical elements such as conventional heating, ventilation and air conditioning would need to be studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microbial Fuel Cells: Methodology and Technology
Logan, B. E., Hamelers, B., Rozendal, R., Schröder, U., Keller, J., Freguia, S., Aelterman, P., Verstraete, W., & Rabaey, K. (2006) · Environmental Science & Technology · doi:10.1021/es0605016 · Cited by 6,065 · cited 2×
“Logan et al.(97) created a plant microbial fuel cell, which is based on the following principle: with the aid of sunlight, plants convert CO2 into organic compounds (photosynthesis).”
BackgroundSalt, D. E., Smith, R. D., & Raskin, I. (1998) · Annual Review of Plant Physiology and Plant Molecular Biology · doi:10.1146/annurev.arplant.49.1.643 · Cited by 2,085
Pilon-Smits, E. (2005) · Annual Review of Plant Biology · doi:10.1146/annurev.arplant.56.032604.144214 · Cited by 2,020
Plant and mycorrhizal regulation of rhizodeposition
Jones, D. L., Hodge, A., & Kuzyakov, Y. (2004) · New Phytologist · doi:10.1111/j.1469-8137.2004.01130.x · Cited by 1,371
WHO Guidelines for Indoor Air Quality: Selected Pollutants
Who Regional Office for Europe (2011) · Cited by 1,300
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Rhizosphere processes and management in plant-assisted bioremediation (phytoremediation) of soils
Wenzel, W. W. (2009) · Plant and Soil · doi:10.1007/s11104-008-9686-1 · Cited by 588 · cited 1×
“It has been shown that roots can absorb pollutants by themselves,(79) but can also increase the availability of pollutants for the microorganisms.(80) Increased bioavailability has been achieved through the excretion of root exudates.”
BackgroundFrontczak, M., Schiavon, S., Goins, J., Arens, E., Zhang, H., & Wargocki, P. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00745.x · Cited by 562
Exploitation of plants for the removal of organics in environmental remediation
Macek, T., Macková, M., & Káš, J. (2000) · Biotechnology Advances · doi:10.1016/s0734-9750(99)00034-8 · Cited by 535
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
Biofiltration of Air: A Review
Delhoménie, M.-C., & Heitz, M. (2005) · Critical Reviews in Biotechnology · doi:10.1080/07388550590935814 · Cited by 409
Interior Plants May Improve Worker Productivity and Reduce Stress in a Windowless Environment
Lohr, V. I., Pearson-Mims, C. H., & Goodwin, G. K. (1996) · Journal of Environmental Horticulture · doi:10.24266/0738-2898-14.2.97 · Cited by 387 · cited 5×
“%) and dry irritated throat (20%).5 Although the prevalence of most of these symptoms was most likely multifactorial (individual, occupational and environmental risk factors were involved), several indoor air pollution sources were pointed out as important risk factors, in particular for dry eyes complaints, showing t…”
BackgroundInfluentialDevelopments in odour control and waste gas treatment biotechnology: a review
Burgess, J. E., Parsons, S. A., & Stuetz, R. M. (2001) · Biotechnology Advances · doi:10.1016/s0734-9750(00)00058-6 · Cited by 364
Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017) · Indoor Air · doi:10.1111/ina.12284 · Cited by 360 · cited 2×
“Nevertheless, CO2 has not been considered to be a pollutant but rather an indicator of the presence of pollutants that are related to the presence of people indoors.(56) Plants use energy caught in leaf pigments during the photosynthetic process, for the conversion of CO2 and water to cellulose, while producing oxygen.”
BackgroundEvaluation of green walls as a passive acoustic insulation system for buildings
Azkorra, Z., Pérez, G., Coma, J., Cabeza, L. F., Bures, S., Álvaro, J. E., Erkoreka, A., & Urrestarazu, M. (2015) · Applied Acoustics · doi:10.1016/j.apacoust.2014.09.010 · Cited by 325 · cited 1×
“Finally, sound levels can be reduced by the destructive interference of sound waves due to the growth media.(99,100) Thus, there are several factors that influence noise reduction in an LWS, such as the depth of the growing medium, the materials used as structural components and the overall coverage.”
BackgroundBiological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308 · cited 3×
“The growth media is generally a natural material, which is biodegradable and provides nutrients to the microorganisms, although intensive research has been done on using synthetic materials.(29,89) There are different green systems and strategies that can be used within the indoor environment, such as living wall syst…”
BackgroundIranpour, R., Cox, H. H. J., Deshusses, M. A., & Schroeder, E. D. (2005) · Environmental Progress · doi:10.1002/ep.10077 · Cited by 297
Direct Observation of Organic Contaminant Uptake, Storage, and Metabolism within Plant Roots
Wild, E., Dent, J., Thomas, G. O., & Jones, K. C. (2005) · Environmental Science & Technology · doi:10.1021/es048136a · Cited by 291
Benefits of indoor plants on attention capacity in an office setting
Raanaas, R. K., Evensen, K. H., Rich, D., Sjøstrøm, G., & Patil, G. (2011) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2010.11.005 · Cited by 282 · cited 1×
“performance to indoor environment.(8,11,43,44) In active”
Road traffic noise shielding by vegetation belts of limited depth
Van Renterghem, T., Botteldooren, D., & Verheyen, K. (2012) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2012.01.006 · Cited by 226 · cited 2×
“Finally, sound levels can be reduced by the destructive interference of sound waves due to the growth media.(99,100) Thus, there are several factors that influence noise reduction in an LWS, such as the depth of the growing medium, the materials used as structural components and the overall coverage.”
BackgroundRemoval of Benzene by the Indoor Plant/Substrate Microcosm and Implications for Air Quality
Orwell, R. L., Wood, R. L., Tarran, J., Torpy, F., & Burchett, M. D. (2004) · Water, Air, and Soil Pollution · doi:10.1023/b:wate.0000038896.55713.5b · Cited by 220 · cited 1×
“indoor air.(2,40,68,78) It has been shown that roots can absorb pollutants by themselves,(79) but can also increase the availability of pollutants for the microorganisms.”
BackgroundPsychological Benefits of Indoor Plants in Workplaces: Putting Experimental Results into Context
Bringslimark, T., Hartig, T., & Patil, G. G. (2007) · HortScience · doi:10.21273/hortsci.42.3.581 · Cited by 218 · cited 1×
“performance to indoor environment.(8,11,43,44) In active”
Foliage plants for removing indoor air pollutants from energy-efficient homes
Wolverton, B. C., Mcdonald, R. C., & Watkins, E. A. (1984) · Economic Botany · doi:10.1007/bf02858837 · Cited by 204 · cited 6×
“Consequently, health professionals, architects, researchers and building industry undertook actions to improve IAQ through different systems and techniques.45 In the 1980s, the NASA Clean Air Study presented some studies about the behaviour of plants regarding IAQ.”
BackgroundInfluentialHealth Effects of Mycotoxins in Indoor Air: A Critical Review
Robbins, C. A., Swenson, L. J., Nealley, M. L., Kelman, B. J., & Gots, R. E. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050129419 · Cited by 197 · cited 1×
“This beneficial effect when indoor air is too dry (moisture contents of 30–70% are generally recommended for comfort) could also cause an excessive growth of fungi with negative impact on IAQ,(93) although these effects are still uncertain.(94,95) Darlington et al.”
BackgroundScreening Indoor Plants for Volatile Organic Pollutant Removal Efficiency
Yang, D. S., Pennisi, S. V., Son, K.-C., & Kays, S. J. (2009) · HortScience · doi:10.21273/hortsci.44.5.1377 · Cited by 194
Formaldehyde removal by common indoor plant species and various growing media
Aydogan, A., & Montoya, L. D. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.02.062 · Cited by 191 · cited 1×
“Some studies have shown that activated carbon is the most effective microbial biofilter.(84,85)”
BackgroundCan ornamental potted plants remove volatile organic compounds from indoor air? — a review
Dela Cruz, M., Christensen, J. H., Thomsen, J. D., & Müller, R. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3240-x · Cited by 190 · cited 8×
“However, the pollutant may be excreted by the roots and subsequently degraded by microorganisms in the soil or adsorbed to the soil particles.(62) Microorganisms existing in the soil of potted plants have appeared to be essential in removal of VOCs from Figure 2.”
BackgroundInfluentialGray, T. L., & Birrell, C. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph111212204 · Cited by 182 · cited 2×
“Some benefits perceived by workers using vegetation within the working environment that have been put forward are enhanced collaboration amongst staff, including across teams, improved morale, reduced stress and decreased absenteeism.(11,14) Additionally, Mangone and van der Linden(61) stated that the use of vegetatio…”
BackgroundDarlington, A. B., Dat, J. F., & Dixon, M. A. (2001) · Environmental Science & Technology · doi:10.1021/es0010507 · Cited by 181 · cited 1×
“• Finally, existing research suggests that in an active vegetation system (green systems in combination with mechanical fans), air-cleaning rates may be significantly higher than in a passive vegetation system (potted plants).(37,96)”
BackgroundBotanical biofiltration of indoor gaseous pollutants – A mini-review
Soreanu, G., Dixon, M., & Darlington, A. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.06.074 · Cited by 179 · cited 6×
“Gas diffusion models can be used to analyse the exchange of water vapour, CO2 and other pollutants between the atmosphere and the plant leaves.63 According to Soreanu et al.,47 about 120 individual plants species have been analysed by different researchers in several pot-based studies for VOC removal and the following…”
BackgroundInfluentialThe effect of perceived indoor air quality on productivity loss
Kosonen, R., & Tan, F. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.06.005 · Cited by 177
The Potted-Plant Microcosm Substantially Reduces Indoor Air VOC Pollution: I. Office Field-Study
Wood, R. A., Burchett, M. D., Alquezar, R., Orwell, R. L., Tarran, J., & Torpy, F. (2006) · Water, Air, and Soil Pollution · doi:10.1007/s11270-006-9124-z · Cited by 172 · cited 1×
“It has also been stated that rhizosphere degradation (rhizoremediation) could play a major role in VOC removal by botanical biofiltration.(30) Some studies have shown that most plants have limited pollutant removal capacity in the absence of rhizosphere microorganisms.”
BackgroundFruit Tree model for uptake of organic compounds from soil and air†
Trapp, S. (2007) · SAR and QSAR in Environmental Research · doi:10.1080/10629360701303693 · Cited by 171 · cited 1×
“The relative importance of the stomatal uptake, compared to the cuticular uptake, seemed therefore to be dependent on the VOC in question.(76,77) After entering the leaf, a compound can suffer degradation, storage or excretion, either at site of uptake or after translocation to other parts of the plant.”
BackgroundPotted-plant/growth media interactions and capacities for removal of volatiles from indoor air
Wood, R. A., Orwell, R. L., Tarran, J., Torpy, F., & Burchett, M. (2002) · The Journal of Horticultural Science and Biotechnology · doi:10.1080/14620316.2002.11511467 · Cited by 167 · cited 1×
“indoor air.(2,40,68,78) It has been shown that roots can absorb pollutants by themselves,(79) but can also increase the availability of pollutants for the microorganisms.”
BackgroundBluyssen, P. M., Roda, C., Mandin, C., Fossati, S., Carrer, P., de Kluizenaar, Y., Mihucz, V. G., de Oliveira Fernandes, E., & Bartzis, J. (2016) · Indoor Air · doi:10.1111/ina.12196 · Cited by 167 · cited 1×
“In a recent study named OFFICAIR, performed in 167 office buildings in eight European countries, the most prevailing building-related health symptoms of the 7441 office workers included in the survey were dry eyes (31%), headache (29%) and dry irritated throat (20%).(5) Although the prevalence of most of these symptom…”
BackgroundSelf-citationBacterial degradation of airborne phenol in the phyllosphere
Sandhu, A., Halverson, L. J., & Beattie, G. A. (2007) · Environmental Microbiology · doi:10.1111/j.1462-2920.2006.01149.x · Cited by 163 · cited 1×
“Additionally, it was found that some bacteria growing on plant leaves also contribute to VOC biodegradation.(48) Wetzel and Doucette(16) stated that the waxy cuticle coating on leaves may provide a simple, costeffective means to sample indoor air for VOCs and to help improve IAQ.”
BackgroundPhytoremediation of particulate matter from indoor air by Chlorophytum comosum L. plants
Gawrońska, H., & Bakera, B. (2015) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-014-0285-4 · Cited by 158
Kim, K. J., Kil, M. J., Song, J. S., Yoo, E. H., Son, K.-C., & Kays, S. J. (2008) · Journal of the American Society for Horticultural Science · doi:10.21273/jashs.133.4.521 · Cited by 158 · cited 1×
“It was therefore concluded that these compounds were taken up through the stomata, as stomata open in light and close in darkness.(28,67,74,75) The pathway for VOC uptake by the above-ground plant parts seems likely to dependent on the properties of VOCs.”
BackgroundMeasuring the Impact of Selected Plants on Indoor CO2 Concentrations
Çetin, M., & Şevik, H. (2016) · Polish Journal of Environmental Studies · doi:10.15244/pjoes/61744 · Cited by 152 · cited 1×
“55 CO2 concentrations change based on human activity in indoor living spaces.(55) In fact, research has shown that in non-industrial indoor environments such as offices, schools and homes, the major source of CO2 is human metabolism.”
BackgroundThe Potted-Plant Microcosm Substantially Reduces Indoor Air VOC Pollution: II. Laboratory Study
Orwell, R. L., Wood, R. A., Burchett, M. D., Tarran, J., & Torpy, F. R. (2006) · Water Air & Soil Pollution · doi:10.1007/s11270-006-9092-3 · Cited by 150
Which ornamental plant species effectively remove benzene from indoor air?
Liu, Y., Mu, Y., Zhu, Y., Ding, H., & Arens, N. C. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.001 · Cited by 148
Irga, P. J., Paull, N. J., Abdo, P., & Torpy, F. R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.01.035 · Cited by 140
Lambers, H., Chapin, F. S., & Pons, T. L. (2008) · Springer eBooks · doi:10.1007/978-0-387-78341-3_2 · Cited by 139
Irga, P. J., Torpy, F. R., & Burchett, M. D. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.04.078 · Cited by 137 · cited 1×
“indoor air.(2,40,68,78) It has been shown that roots can absorb pollutants by themselves,(79) but can also increase the availability of pollutants for the microorganisms.”
BackgroundFormaldehyde removal by potted plant–soil systems
Xu, Z., Wang, L., & Hou, H. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.05.020 · Cited by 137 · cited 5×
“It was therefore concluded that these compounds were taken up through the stomata, as stomata open in light and close in darkness.28,67,74,75 The pathway for VOC uptake by the above-ground plant parts seems likely to dependent on the properties of VOCs.”
BackgroundInfluentialInfluence of an active living wall on indoor temperature and humidity conditions
Urrestarazu, L. P., Cañero, R. F., Salas, A. F., & Egea, G. (2016) · Ecological Engineering · doi:10.1016/j.ecoleng.2016.01.050 · Cited by 134 · cited 1×
“It is shown to be possible to use the evapotranspiration of plants for air cooling and humidity control.(90,101,102) In 2011, a study of indoor living systems performed in warm climates tested different substrates, and the following was concluded:(103)”
BackgroundVariation in Formaldehyde Removal Efficiency among Indoor Plant Species
Kim, K. J., Jeong, M. I., Lee, D. W., Song, J. S., Kim, H., Yoo, E. H., Jeong, S. J., Han, S. W., Kays, S. J., Lim, Y.-W., et al. (2010) · HortScience · doi:10.21273/hortsci.45.10.1489 · Cited by 126
Gao, Y., Cheng, Z., Ling, W., & Huang, J. H. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.03.122 · Cited by 125
Wang, Z., & Zhang, J. S. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.10.008 · Cited by 121 · cited 2×
“Some studies have shown that activated carbon is the most effective microbial biofilter.(84,85)”
BackgroundThe Effect of Interior Planting on Health and Discomfort among Workers and School Children
Fjeld, T. (2000) · HortTechnology · doi:10.21273/horttech.10.1.46 · Cited by 118 · cited 1×
“People spend on average 80% of their time indoors,(1,2) therefore, the health risks due to indoor air pollution may be greater than outdoor air pollution.(3,4) From past studies, it is clear that indoor environmental quality (IEQ) can play an important role in work performance, productivity and the health of building…”
BackgroundRemoval of benzene from indoor air by Dracaena sanderiana: Effect of wax and stomata
Treesubsuntorn, C., & Thiravetyan, P. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.04.016 · Cited by 117 · cited 1×
“It was therefore concluded that these compounds were taken up through the stomata, as stomata open in light and close in darkness.(28,67,74,75) The pathway for VOC uptake by the above-ground plant parts seems likely to dependent on the properties of VOCs.”
BackgroundWang, Z., Pei, J., & Zhang, J. S. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.07.059 · Cited by 108
Schmitz, H., HILGERS, U., & Weidner, M. (2000) · New Phytologist · doi:10.1046/j.1469-8137.2000.00701.x · Cited by 106
Air Pollution and Plant Biotechnology
(2002) · Springer eBooks · doi:10.1007/978-4-431-68388-9 · Cited by 104 · cited 1×
“Gas diffusion models can be used to analyse the exchange of water vapour, CO2 and other pollutants between the atmosphere and the plant leaves.(63) According to Soreanu et al.”
MethodHwa Yoo, M., Kwon, Y. J., Son, K.-C., & Kays, S. J. (2006) · Journal of the American Society for Horticultural Science · doi:10.21273/jashs.131.4.452 · Cited by 103 · cited 1×
“It was therefore concluded that these compounds were taken up through the stomata, as stomata open in light and close in darkness.(28,67,74,75) The pathway for VOC uptake by the above-ground plant parts seems likely to dependent on the properties of VOCs.”
BackgroundThe Biofiltration of Indoor Air: Implications for Air Quality
Darlington, A. B., Chan, M.-Y., Malloch, D., Pilger, C. W., & Dixon, M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010001039.x · Cited by 97 · cited 2×
“There are different green systems and strategies that can be used within the indoor environment, such as living wall systems (LWSs) that are vertical hydroponical systems pictured as ecological cores that can be also used as a biofilter (biowall).(37) An LWS supports vegetation that is either rooted on the walls or in…”
BackgroundDavis, M. J. M., Tenpierik, M., Ramírez, F., & Pérez, M. E. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.01.010 · Cited by 96 · cited 2×
“An LWS can also be used as a passive acoustical insulation system.(98) Some studies show that vegetation can reduce sound levels in three ways.”
BackgroundMangone, G., Kurvers, S. R., & Luscuere, P. G. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.07.019 · Cited by 93 · cited 3×
“While some researchers found that vegetation may improve worker productivity and creativity(4,12,58) other researchers found that vegetation may improve occupant comfort and their overall perception of the quality of their environment creating a more desirable place to work.(13,59,60) Some benefits perceived by worker…”
BackgroundStudies on the Decontamination of Air by Plants
Cornejo, J., Muñoz, F. G., Ma, C. Y., & Stewart, A. J. (1999) · Ecotoxicology · doi:10.1023/a:1008937417598 · Cited by 90
Davis, M. J. M., & Hirmer, S. A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.033 · Cited by 81 · cited 3×
“Moreover, it is possible to use the evapotranspiration of plants for air cooling and humidity control.(90) LWSs can work as biofilters when they work as an active vegetation system.”
BackgroundZhan, X., Xiao, L., Xu, G., & Zhou, L. (2013) · Environmental Pollution · doi:10.1016/j.envpol.2013.04.033 · Cited by 80 · cited 1×
“Uptake by roots has been found to depend on the root morphology where the lipid content and specific surface area are significant parameters.(83) Once absorbed by the root, the pollutant could therefore undergo the same processes as in the leaf (i.”
BackgroundGenes and Enzymes for In-Planta Phytoremediation of Air, Water and Soil
Schäffner, A. R., Meßner, B., Langebartels, C., & Sandermann, H. (2002) · Acta Biotechnologica · doi:10.1002/1521-3846(200205)22:1/2<141::aid-abio141>3.0.co;2-7 · Cited by 80
Uptake of Aldehydes and Ketones at Typical Indoor Concentrations by Houseplants
Tani, A., & HEWITT, C. N. (2009) · Environmental Science & Technology · doi:10.1021/es9020316 · Cited by 75
Formaldehyde biofiltration as affected by spider plant
Xu, Z., Qin, N., Wang, J., & Tong, H. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.03.128 · Cited by 65
Chen, L., Yurimoto, H., Li, K., Orita, I., Akita, M., Kato, N., Sakai, Y., & Izui, K. (2010) · Bioscience Biotechnology and Biochemistry · doi:10.1271/bbb.90847 · Cited by 58 · cited 1×
“Some studies have shown that most plants have limited pollutant removal capacity in the absence of rhizosphere microorganisms.(72) Guieysse et al.”
BackgroundOffice characteristics and dry eye complaints in European workers–The OFFICAIR study
de Kluizenaar, Y., Roda, C., Dijkstra, N. E., Fossati, S., Mandin, C., Mihucz, V. G., Hänninen, O., Fernandes, E. D. O., Silva, G. V., Carrer, P., et al. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.013 · Cited by 56 · cited 1×
“involved), several indoor air pollution sources were pointed out as important risk factors, in particular for dry eyes complaints, showing the potential for green systems.(57) In 1996, Lohr et al.”
BackgroundSelf-citationEffects on air pollutant removal by plant absorption and adsorption
Fujii, S., Cha, H., Kagi, N., 宮村, 壽., & Kim, Y.-S. (2004) · Building and Environment · doi:10.1016/j.buildenv.2004.04.015 · Cited by 54
Assessment of volatile organic compound removal by indoor plants—a novel experimental setup
Cruz, M. D., Müller, R., Svensmark, B., Pedersen, J. S., & Christensen, J. H. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2695-0 · Cited by 54
Relationships between Plants, Behavior, and Attitudes in an Office Environment
Shoemaker, C. A., Randall, K., Relf, P. D., & Geller, E. S. (1992) · HortTechnology · doi:10.21273/horttech.2.2.205 · Cited by 51 · cited 1×
“While some researchers found that vegetation may improve worker productivity and creativity(4,12,58) other researchers found that vegetation may improve occupant comfort and their overall perception of the quality of their environment creating a more desirable place to work.(13,59,60) Some benefits perceived by worker…”
BackgroundChanges in the Phytoremediation Potential of Indoor Plants with Exposure to Toluene
Kim, K. J., Yoo, E. H., Jeong, M. I., Song, J. S., Lee, S. Y., & Kays, S. J. (2011) · HortScience · doi:10.21273/hortsci.46.12.1646 · Cited by 47
Improvement of Indoor Air Quality by Houseplants in New-built Apartment Buildings
Lim, Y.-W., Kim, H.-H., Yang, J.-Y., Kim, K. J., Lee, J., & Shin, D.-C. (2009) · Journal of the Japanese Society for Horticultural Science · doi:10.2503/jjshs1.78.456 · Cited by 41
More than just a Green Façade: Vertical Gardens as Active Air Conditioning Units
Davis, M. J. M., Ramírez, F. C., & Pérez, M. E. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.04.161 · Cited by 35 · cited 2×
“• Vegetation has been found to improve occupant comfort, as well as their perception of the quality of their environment, including thermal comfort and acoustics.(59,98,104) • Several research studies indicate the possible effect of vegetation on IAQ.”
BackgroundReflections on the state of research: indoor environmental quality
Clausen, G., Bekö, G., Corsi, R. L., Gunnarsen, L., Nazaroff, W. W., Olesen, B. W., Sigsgaard, T., Sundell, J., Toftum, J., & Weschler, C. J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00706.x · Cited by 34 · cited 2×
“Clausen et al.(71) recommended to use a large leaf surface area in combination with an appropriate ventilation rate to obtain an appropriate performance with potted plants.”
BackgroundThe potential for indoor ultrafine particle reduction using vegetation under laboratory conditions
Stapleton, E. M., & Ruiz-Rudolph, P. (2016) · Indoor and Built Environment · doi:10.1177/1420326x16668388 · Cited by 34
Psychological and Sociological Response to Plants: Implications for Horticulture
Relf, P. D. (1990) · HortScience · doi:10.21273/hortsci.25.1.11 · Cited by 31 · cited 1×
“Some benefits perceived by workers using vegetation within the working environment that have been put forward are enhanced collaboration amongst staff, including across teams, improved morale, reduced stress and decreased absenteeism.(11,14) Additionally, Mangone and van der Linden(61) stated that the use of vegetatio…”
BackgroundPlant leaves as indoor air passive samplers for volatile organic compounds (VOCs)
Wetzel, T. A., & Doucette, W. J. (2014) · Chemosphere · doi:10.1016/j.chemosphere.2014.10.065 · Cited by 28
Mangone, G., & van der Linden, K. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.11.012 · Cited by 28
Decay Kinetics of Toluene Phytoremediation Stimulation
Kim, K. J., Yoo, E. H., & Kays, S. J. (2012) · HortScience · doi:10.21273/hortsci.47.8.1195 · Cited by 20
Technical Note: Purification Characteristics of Golden Pothos for Atmospheric Gasoline
Oyabu, T., Takenaka, K., Wolverton, B. C., Onodera, T., & Nanto, H. (2003) · International Journal of Phytoremediation · doi:10.1080/713779225 · Cited by 16
Cited by
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
Dzhambov, A. M., Lercher, P., Browning, M. H. E. M., Stoyanov, D., Petrova, N., Novakov, S., & Dimitrova, D. D. (2021) · Environmental Research · doi:10.1016/j.envres.2020.110420 · Cited by 285
Indoor Air Quality: A Review of Cleaning Technologies
Mata, T. M., Martins, A. A., Calheiros, C. S. C., Villanueva, F., Alonso-Cuevilla, N. P., Gabriel, M. F., & Silva, G. V. (2022) · Environments · doi:10.3390/environments9090118 · Cited by 176
“In general terms, active vegetation systems (in combination with mechanical systems) and passive vegetation systems (without additional energy requirements) can be considered for the present purpose [130,133].”
BackgroundInfluentialNature-based solutions as tools for air phytoremediation: A review of the current knowledge and gaps
Prigioniero, A., Zuzolo, D., Niinemets, Ü., & Guarino, C. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.116817 · Cited by 51
Sharma, S., Bakht, A., Jahanzaib, M., Lee, H., & Park, D. (2022) · doi:10.21203/rs.3.rs-2091762/v1 · Cited by 44
Metadata
- Authors
- Moya, T. A., van den Dobbelsteen, A., Ottelé, M., & Bluyssen, P. M.
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 2018-06-20
- Volume
- 28
- Issue
- 3
- Pages
- 298-309
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W2809518184
- Cited by
- 160
- References
- 79
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.