Signal encoding in magnetic particle imaging: properties of the system function
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Magnetic particle imaging (MPI) is a new tomographic imaging technique capable of imaging magnetic tracer material at high temporal and spatial resolution. Image reconstruction requires solving a system of linear equations, which is characterized by a "system function" that establishes the relation between spatial tracer position and frequency response. This paper for the first time reports on the structure and properties of the MPI system function. METHODS: An analytical derivation of the 1D MPI system function exhibits its explicit dependence on encoding field parameters and tracer properties. Simulations are used to derive properties of the 2D and 3D system function. RESULTS: It is found that for ideal tracer particles in a harmonic excitation field and constant selection field gradient, the 1D system function can be represented by Chebyshev polynomials of the second kind. Exact 1D image reconstruction can thus be performed using the Chebyshev transform. More realistic particle magnetization curves can be treated as a convolution of the derivative of the magnetization curve with the Chebyshev functions. For 2D and 3D imaging, it is found that Lissajous excitation trajectories lead to system functions that are closely related to tensor products of Chebyshev functions. CONCLUSION: Since to date, the MPI system function has to be measured in time-consuming calibration scans, the additional information derived here can be used to reduce the amount of information to be acquired experimentally and can hence speed up system function acquisition. Furthermore, redundancies found in the system function can be removed to arrive at sparser representations that reduce memory load and allow faster image reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Chebyshev and Fourier Spectral Methods
Boyd, J. P. (2001) · Cited by 4,216
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Self-citationBean, C. P., & Livingston, J. D. (1959) · Journal of Applied Physics · doi:10.1063/1.2185850 · Cited by 1,773
Bronshtein, I. N., & Semendjaev, K. A. (1966) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,467
Wörle, H., Rumpf, H.-J., & Erven, J. (1994) · De Gruyter eBooks · doi:10.1515/9783486785449 · Cited by 1,465
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Self-citationElectromagnetic Analysis and Design in Magnetic Resonance Imaging
Jin, J. (2018) · Routledge eBooks · doi:10.1201/9780203758731 · Cited by 502
Principles of Magnetic Resonance Imaging
Liang, Z.-P., & Lauterbur, P. C. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545652 · Cited by 412
Cited by
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Goodwill, P. W., & Conolly, S. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2052284 · Cited by 395
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
X‐Space MPI: Magnetic Nanoparticles for Safe Medical Imaging
Goodwill, P. W., Saritas, E. U., Croft, L. R., Kim, T. N., Krishnan, K. M., Schaffer, D. V., & Conolly, S. M. (2012) · Advanced Materials · doi:10.1002/adma.201200221 · Cited by 301
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“The first is a system matrix-based reconstruction that depends on a supplemental calibration scan that is performed by moving a delta-sample by robotic means, 1,21,22 and the second is a direct reconstruction known as x-space MPI, which is based on some idealized assumptions.”
BackgroundDu, Y., Liu, X., Liang, Q., Liang, X.-J., & Tian, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b00630 · Cited by 260
Magnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222
Self-citationHigh-performance iron oxide nanoparticles for magnetic particle imaging – guided hyperthermia (hMPI)
Bauer, L. M., Situ, S. F., Griswold, M. A., & Samia, A. C. S. (2016) · Nanoscale · doi:10.1039/c6nr01877g · Cited by 222
A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging
Wu, L. C., Zhang, Y., Steinberg, G., Qu, H., Huang, S., Cheng, M., Bliss, T., Du, F., Rao, J., Song, G., et al. (2019) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5896 · Cited by 205
Weighted iterative reconstruction for magnetic particle imaging
Knopp, T., Rahmer, J., Sattel, T. F., Biederer, S., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/6/003 · Cited by 199
“The individual frequency components show similarity to 2D tensor products of Chebyshev polynomials (Rahmer et al 2009).”
BackgroundSelf-citationProjection X-Space Magnetic Particle Imaging
Goodwill, P. W., Konkle, J. J., Zheng, B., Saritas, E. U., & Conolly, S. T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2185247 · Cited by 185
“Gradient Strength: The native resolution of MPI potentially improves cubically with the nanoparticle diameter and linearly with the gradient strength [8], [17], [18].”
BackgroundMethodInfluentialAnalysis of a 3-D System Function Measured for Magnetic Particle Imaging
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188639 · Cited by 171
Self-citationMonodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
Khandhar, A. P., Ferguson, R. M., Arami, H., & Krishnan, K. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.087 · Cited by 152
“In the x-space approach [19], image reconstruction is achieved by a convolution of the tracer distribution and PSF;”
MethodMagnetic particle imaging: visualization of instruments for cardiovascular intervention
Haegele, J., Rahmer, J., Gleich, B., Borgert, J., Wojtczyk, H., Panagiotopoulos, N., Buzug, T. M., Barkhausen, J., & Vogt, F. M. (2012) · Radiology · doi:10.1148/radiol.12120424 · Cited by 151
Self-citationDesign of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81
“theoretical magnetization curve expressed by Equation (1) and G is the gradient of the selection field [19,22].”
BackgroundFirst in vivo traveling wave magnetic particle imaging of a beating mouse heart
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W. H., Jakob, P. M., & Behr, V. C. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/18/6620 · Cited by 60
Metadata
- Authors
- Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J.
- Venue
- BMC Medical Imaging
- Published
- 2009-04-01
- Volume
- 9
- Issue
- 1
- Pages
- 4-4
- ISSN
- 1471-2342 (ISSN-L)
- OpenAlex
- W2058917901
- Cited by
- 345
- References
- 14
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.