Advances in wearable technology and applications in physical medicine and rehabilitation
Open accessAbstract
The development of miniature sensors that can be unobtrusively attached to the body or can be part of clothing items, such as sensing elements embedded in the fabric of garments, have opened countless possibilities of monitoring patients in the field over extended periods of time. This is of particular relevance to the practice of physical medicine and rehabilitation. Wearable technology addresses a major question in the management of patients undergoing rehabilitation, i.e. have clinical interventions a significant impact on the real life of patients? Wearable technology allows clinicians to gather data where it matters the most to answer this question, i.e. the home and community settings. Direct observations concerning the impact of clinical interventions on mobility, level of independence, and quality of life can be performed by means of wearable systems. Researchers have focused on three main areas of work to develop tools of clinical interest: 1)the design and implementation of sensors that are minimally obtrusive and reliably record movement or physiological signals, 2)the development of systems that unobtrusively gather data from multiple wearable sensors and deliver this information to clinicians in the way that is most appropriate for each application, and 3)the design and implementation of algorithms to extract clinically relevant information from data recorded using wearable technology. Journal of NeuroEngineering and Rehabilitation has devoted a series of articles to this topic with the objective of offering a description of the state of the art in this research field and pointing to emerging applications that are relevant to the clinical practice in physical medicine and rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Finally, applications in rehabilitation of remote monitoring systems relying on wearable sensors [36] have largely relied upon inertial sensors for movement detection and tracking.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [36]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 615
Physical rehabilitation outcome measures : a guide to enhanced clinical decision making
Finch, E. (2002) · Lippincott Williams & Wilkins eBooks · Cited by 399
Aminian, K., Robert, P. A., Buchser, E., Rutschmann, B., Hayoz, D., & Depairon, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513304 · Cited by 309
User‐adaptive control of a magnetorheological prosthetic knee
Herr, H., & Wilkenfeld, A. (2003) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439910310457706 · Cited by 294
Motion pattern and posture: Correctly assessed by calibrated accelerometers
Foerster, F., & Fahrenberg, J. (2000) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200815 · Cited by 188
Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185
Quantification of physical activities by means of ambulatory accelerometry: A validation study
Bussmann, J. B. J., Tulen, J. H. M., van Herel, E. C. G., & Stam, H. J. (1998) · Psychophysiology · doi:10.1017/s0048577298971153 · Cited by 142
Kay, T., & Huijbregts, M. P. J. (2003) · Physiotherapy Canada · doi:10.2310/6640.2003.35271 · Cited by 139
Automatic assessment of levodopa‐induced dyskinesias in daily life by neural networks
Keijsers, N., Horstink, M. W. I. M., & Gielen, S. C. A. M. (2002) · Movement Disorders · doi:10.1002/mds.10310 · Cited by 139
Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?
Giansanti, D., Macellari, V., Maccioni, G., & Cappozzo, A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.809490 · Cited by 127
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Self-citationA Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Gait variability: methods, modeling and meaning
Hausdorff, J. M. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-19 · Cited by 942
The relevance of clinical balance assessment tools to differentiate balance deficits.
Mancini, M., & Horak, F. B. (2010) · PubMed · Cited by 695
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Self-citationLyons, E. J., Lewis, Z. H., Mayrsohn, B. G., & Rowland, J. L. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.3469 · Cited by 547
Timmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Video task analysis of turning during activities of daily living
Glaister, B. C., Bernatz, G. C., Klute, G. K., & Orendurff, M. S. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.04.003 · Cited by 420
Noise‐enhanced balance control in patients with diabetes and patients with stroke
Priplata, A. A., Patritti, B. L., Niemi, J. B., Hughes, R. L., Gravelle, D. C., Lipsitz, L. A., Veves, A., Stein, J. M., Bonato, P., & Collins, J. J. (2005) · Annals of Neurology · doi:10.1002/ana.20670 · Cited by 377
Self-citationActivity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. A. A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 350
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
Self-citationA Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Self-citationPolymer based thermoelectric nanocomposite materials and devices: Fabrication and characteristics
Nandihalli, N., Liu, C., & Mori, T. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105186 · Cited by 296
Postural Instability in Patients with Parkinson’s Disease
Kim, S. D., Allen, N. E., Canning, C. G., & Fung, V. S. C. (2012) · CNS Drugs · doi:10.1007/s40263-012-0012-3 · Cited by 238
Design and Modeling of a Textile Pressure Sensor for Sitting Posture Classification
Meyer, J. T., Bert Arnrich, A., Schumm, J., & Tröster, G. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2037330 · Cited by 236
Pain and Stress Detection Using Wearable Sensors and Devices—A Review
Chen, J., Abbod, M., & Shieh, J.-S. (2021) · Sensors · doi:10.3390/s21041030 · Cited by 234
Wearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205
Artificial Intelligence-Based Wearable Robotic Exoskeletons for Upper Limb Rehabilitation: A Review
Vélez-Guerrero, M. A., Callejas-Cuervo, M., & Mazzoleni, S. (2021) · Sensors · doi:10.3390/s21062146 · Cited by 202
Development of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333698 · Cited by 183
Wearable Sensor Systems for Fall Risk Assessment: A Review
Subramaniam, S., Faisal, A. I., & Deen, M. J. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.921506 · Cited by 178
Mancini, M., Zampieri, C., Carlson‐Kuhta, P., Chiari, L., & Horak, F. B. (2009) · European Journal of Neurology · doi:10.1111/j.1468-1331.2009.02641.x · Cited by 177
A Novel Approach to Monitor Rehabilitation Outcomes in Stroke Survivors Using Wearable Technology
Patel, S., Hughes, R., Hester, T., Stein, J., Akay, M., Dy, J. G., & Bonato, P. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038727 · Cited by 170
Self-citationMomentary assessment technology as a tool to help patients with depression help themselves
Wichers, M., Simons, C. J. P., Kramer, I., Hartmann, J., Menne‐Lothmann, C., Myin‐Germeys, I., van Bemmel, A. L., Peeters, F. P. M. L., Delespaul, P., & van Os, J. (2011) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.2011.01749.x · Cited by 164
Thill, S., Pop, C., Belpaeme, T., Tom Ziemke, B., & Vanderborght, B. (2012) · Paladyn Journal of Behavioral Robotics · doi:10.2478/s13230-013-0107-7 · Cited by 157
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L. E., & Rodgers, M. M. (2011) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 148
Self-citationA survey on wearable biosensor systems for health monitoring
Pantelopoulos, A., & Bourbakis, N. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650309 · Cited by 147
Ranavolo, A., Draicchio, F., Varrecchia, T., Silvetti, A., & Iavicoli, S. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15092001 · Cited by 158
Adans-Dester, C., Hankov, N., O’Brien, A., Vergara-Diaz, G., Black-Schaffer, R., Zafonte, R., Dy, J., Lee, S. I., & Bonato, P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00328-w · Cited by 130
Self-citationIntelligent Wearable Systems: Opportunities and Challenges in Health and Sports
Yang, L., Amin, O., & Shihada, B. (2024) · ACM Computing Surveys · doi:10.1145/3648469 · Cited by 159
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Noisy vestibular stimulation improves dynamic walking stability in bilateral vestibulopathy
Wuehr, M., Nusser, E., Decker, J., KRAFCZYK, S., Straube, A. M., Brandt, T., Jahn, K., & Schniepp, R. (2016) · Neurology · doi:10.1212/wnl.0000000000002748 · Cited by 119
A low-cost game framework for a home-based stroke rehabilitation system
Saini, S., Rambli, D. R. A., Sulaiman, S. B., Zakaria, M. N., & Shukri, S. R. M. (2012) · doi:10.1109/iccisci.2012.6297212 · Cited by 107
Shah, I. A., & Mishra, S. (2024) · Journal of Occupational Health · doi:10.1093/joccuh/uiad017 · Cited by 156
Shu, F., & Shu, J. (2021) · Scientific Reports · doi:10.1038/s41598-021-81115-9 · Cited by 103
Marci, C. D., & Orr, S. P. (2006) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-006-9008-4 · Cited by 135
Noise-Enhanced Vestibular Input Improves Dynamic Walking Stability in Healthy Subjects
Wuehr, M., Nusser, E., KRAFCZYK, S., Straube, A. M., Brandt, T., Jahn, K., & Schniepp, R. (2015) · Brain stimulation · doi:10.1016/j.brs.2015.08.017 · Cited by 101
Development of a real-time three-dimensional spinal motion measurement system for clinical practice
Goodvin, C., Park, E. J., Huang, K. I., & Sakaki, K. D. R. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0132-3 · Cited by 102
The Manumeter: A Wearable Device for Monitoring Daily Use of the Wrist and Fingers
Friedman, N., Rowe, J. B., Reinkensmeyer, D. J., & Bachman, M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2329841 · Cited by 99
Concurrent Validity of a Commercial Wireless Trunk Triaxial Accelerometer System for Gait Analysis
Ridder, R. D., Lebleu, J., Willems, T. M., Blaiser, C. D., Detrembleur, C., & Roosen, P. (2019) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2018-0295 · Cited by 99
Monitoring Motor Symptoms During Activities of Daily Living in Individuals With Parkinson's Disease
Thorp, J. E., Adamczyk, P. G., Ploeg, H., & Pickett, K. A. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.01036 · Cited by 98
Nasri, N., Orts‐Escolano, S., & Cazorla, M. (2020) · Sensors · doi:10.3390/s20226451 · Cited by 96
Karar, M. E., Shehata, H. I., & Reyad, O. (2022) · Applied Sciences · doi:10.3390/app12073276 · Cited by 94
Training the Body: The Potential of AIED to Support Personalized Motor Skills Learning
Santos, O. C. (2016) · International Journal of Artificial Intelligence in Education · doi:10.1007/s40593-016-0103-2 · Cited by 92
Using machine learning to predict hypertension from a clinical dataset
Lafrenière, D., Zulkernine, F. H., Barber, D., & Martin, K. (2016) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2016.7849886 · Cited by 90
Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors
Del Din, S., Patel, S., Cobelli, C., & Bonato, P. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091444 · Cited by 90
Self-citationMitchell, J., Shirota, C., & Clanchy, K. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01194-9 · Cited by 94
Tactile Robots as a Central Embodiment of the Tactile Internet
Haddadin, S., Johannsmeier, L., & Ledezma, F. D. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2879870 · Cited by 89
Arora, S., Venkataraman, V., Donohue, S., Biglan, K., Dorsey, E. R., & Little, M. A. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854280 · Cited by 85
Smart E-textiles: A review of their aspects and applications
Younes, B. (2023) · Journal of Industrial Textiles · doi:10.1177/15280837231215493 · Cited by 82
Meijer, H. A. W., Graafland, M., Goslings, J. C., & Schijven, M. P. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.10.018 · Cited by 82
Αναστασοπούλου, Π., Tubic, M., Schmidt, S., Neumann, R., Wöll, A., & Härtel, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090606 · Cited by 88
Minimum-Order Kalman Filter With Vector Selector for Accurate Estimation of Human Body Orientation
Lee, J. K., & Park, E. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2017146 · Cited by 81
Wireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 78
Reyes-Guzmán, A. D. L., Gil-Agudo, A. M., Peñasco-Martín, B., Solís-Mozos, M., del‐Ama, A. J., & Pérez-Rizo, E. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-41 · Cited by 76
Muscillo, R., Conforto, S., Schmid, M., Caselli, P., & D’Alessio, T. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353446 · Cited by 76
Liu, Y., Li, J., Xiao, S., Liu, Y., Bai, M., Gong, L., Zhao, J., & Chen, D. (2023) · Biosensors · doi:10.3390/bios13070726 · Cited by 77
The impact of threat and cognitive stress on speech motor control in people who stutter
Lieshout, P. H. H. M. V., Ben‐David, B. M., Lipski, M., & Namasivayam, A. K. (2014) · Journal of Fluency Disorders · doi:10.1016/j.jfludis.2014.02.003 · Cited by 74
Steins, D., Dawes, H., Esser, P., & Collett, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-36 · Cited by 71
Technologies for Assessment of Motor Disorders in Parkinson’s Disease: A Review
Oung, Q. W., Muthusamy, H., Lee, H. L., Basah, S. N., Yaacob, S., Sarillee, M., & Lee, C. K. (2015) · Sensors · doi:10.3390/s150921710 · Cited by 70
Sundararajan, A., Sarwat, A. I., & Pons, A. (2019) · ACM Computing Surveys · doi:10.1145/3309550 · Cited by 73
E-textiles in Clinical Rehabilitation: A Scoping Review
Fleury, A., Sugar, M., & Chau, T. T. (2015) · Electronics · doi:10.3390/electronics4010173 · Cited by 75
Point-of-care biosensor system
Vasan, A. S. S. (2012) · Frontiers in Bioscience-Scholar · doi:10.2741/s357 · Cited by 72
Acceptance of Wearable Technology by People With Alzheimer’s Disease: Issues and Accommodations
Mahoney, E., & Mahoney, D. F. (2010) · American Journal of Alzheimer s Disease & Other Dementias® · doi:10.1177/1533317510376944 · Cited by 69
Advances in health rehabilitation devices based on triboelectric nanogenerators
Gai, Y., Jiang, Y., & Li, Z. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108787 · Cited by 69
Yoon, J., Park, H., & Damiano, D. L. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-62 · Cited by 68
Atashzar, S. F., Carriere, J., & Tavakoli, M. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.610529 · Cited by 68
Real-World Gait Speed Estimation Using Wrist Sensor: A Personalized Approach
Soltani, A., Dejnabadi, H., Savary, M., & Aminian, K. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2914940 · Cited by 66
Application of wearable sensors for human gait analysis using fuzzy computational algorithm
Alaqtash, M., Yu, H., Brower, R. D., Abdelgawad, A. H. K., & Sarkodie-Gyan, T. (2011) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2011.04.010 · Cited by 65
User-Based Motion Sensing and Fuzzy Logic for Automated Fall Detection in Older Adults
Boissy, P., Choquette, S., Hamel, M., & Noury, N. (2007) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2007.0007 · Cited by 60
Novel fabric pressure sensors: design, fabrication, and characterization
Wang, Y., Hua, T., Zhu, B., Li, Q., Yi, W., & Tao, X. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/6/065015 · Cited by 59
A Fast Quaternion-Based Orientation Optimizer via Virtual Rotation for Human Motion Tracking
Lee, J. K., & Park, E. J. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2001285 · Cited by 58
Toh, S. F. M., Fong, K. N. K., González, P. C., & Tang, Y. M. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3252880 · Cited by 62
Hordacre, B. G., Barr, C., & Crotty, M. (2014) · Sensors · doi:10.3390/s140405845 · Cited by 56
Wearable Chemosensors: A Review of Recent Progress
Qian, R., & Long, Y. (2017) · ChemistryOpen · doi:10.1002/open.201700159 · Cited by 59
Ranavolo, A., Varrecchia, T., Iavicoli, S., Marchesi, A., Rinaldi, M., Serrao, M., Conforto, S., Cesarelli, M., & Draicchio, F. (2018) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2018.06.003 · Cited by 55
Bio-feedback System for Rehabilitation Based on a Wireless Body Area Network
Brunelli, D., Farella, E., Rocchi, L., Dozza, M., Chiari, L., & Luca Benini, C. (2006) · IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops) · doi:10.1109/percomw.2006.27 · Cited by 52
Pandey, P., Maharjan, P., Seo, M.-K., Thapa, K., & Sohn, J. I. (2024) · International Journal of Energy Research · doi:10.1155/2024/5572736 · Cited by 54
Mechatronics – More questions than answers
Bradley, D. (2010) · Mechatronics · doi:10.1016/j.mechatronics.2010.07.011 · Cited by 51
Methods and Tools Used for the Measurement of Burn Scar Contracture
Parry, I. S., Walker, K., Niszczak, J., Palmieri, T. L., & Greenhalgh, D. G. (2010) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e3181f9354f · Cited by 51
Benocci, M., Rocchi, L., Farella, E., Chiari, L., & Luca Benini, C. (2009) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth2009.6032 · Cited by 49
Ricci, L., Formica, D., Sparaci, L., Lasorsa, F. R., Taffoni, F., Tamilia, E., & Guglielmelli, E. (2014) · Sensors · doi:10.3390/s140101057 · Cited by 48
Advances in the Application of Technology to Epilepsy: The CIMIT/NIO Epilepsy Innovation Summit
Schachter, S. C., Guttag, J. V., Schiff, S. J., & Schomer, D. L. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.06.028 · Cited by 46
Vital Sign Measurement in Telemedicine Rehabilitation Based on Intelligent Wearable Medical Devices
Fan, Y., Xu, P., Jin, H., Ma, J., & Qin, L. (2019) · IEEE Access · doi:10.1109/access.2019.2913189 · Cited by 47
Advances in Wearable Technology for Rehabilitation
Bonato, P. (2009) · Studies in health technology and informatics · doi:10.3233/978-1-60750-018-6-145 · Cited by 47
Self-citationA Comprehensive Survey on Wearable Computing for Mental and Physical Health Monitoring
Elfouly, T., & Alouani, A. T. (2025) · Electronics · doi:10.3390/electronics14173443 · Cited by 59
Wirelessly accessible sensor populations (WASP) for elderly care monitoring
Atallah, L., Lo, B. P. L., Yang, G., & Siegemund, F. (2008) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1109/pcthealth.2008.4571011 · Cited by 46
Fasel, B., Duc, C., Dadashi, F., Bardyn, F., Savary, M., Farine, P.-A., & Aminian, K. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1621-2 · Cited by 46
Kim, J., Kong, M., Hong, T., Jeong, K., & Lee, M. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.09.018 · Cited by 47
Telemedical Wearable Sensing Platform for Management of Chronic Venous Disorder
Li, R., Nie, B., Zhai, C., Cao, J., Pan, J., Chi, Y., & Pan, T. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1498-x · Cited by 46
Vogel, J., Auinger, A., Riedl, R., Kindermann, H., Helfert, M., & Ocenasek, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186261 · Cited by 51
A New Jellyfish Type of Underwater Microrobot
Guo, S., Shi, L., Ye, X., & Li, L. (2007) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2007.4303595 · Cited by 45
Stuart, T., Kasper, K. A., Iwerunmor, I. C., McGuire, D. T., Peralta, R., Hanna, J., Johnson, M., Farley, M., LaMantia, T., Udorvich, P., et al. (2021) · Science Advances · doi:10.1126/sciadv.abj3269 · Cited by 47
Clinical applications of wearable technology
Bonato, P. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333997 · Cited by 43
Self-citationDesign of a Wearable Sensing System for Human Motion Monitoring in Physical Rehabilitation
González-Villanueva, L., Cagnoni, S., & Ascari, L. (2013) · Sensors · doi:10.3390/s130607735 · Cited by 43
Design and Accuracy of an Instrumented Insole Using Pressure Sensors for Step Count
Ngueleu, A.-M., Blanchette, A. K., Bouyer, L. J., Maltais, D. B., McFadyen, B. J., Moffet, H., & Batcho, C. S. (2019) · Sensors · doi:10.3390/s19050984 · Cited by 43
Li, Y., Liu, P., Fang, Y., Wu, X., Xie, Y., Xu, Z., Ren, H., & Jing, F. (2025) · Sensors · doi:10.3390/s25072205 · Cited by 42
Probabilistic gait classification in children with cerebral palsy: A Bayesian approach
Gestel, L. V., Laet, T. D., Lello, E. D., Bruyninckx, H., Molenaers, G., Campenhout, A. V., Aertbeliën, E., Schwartz, M., Wambacq, H., Cock, P. D., et al. (2011) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2011.07.004 · Cited by 42
Arafsha, F., Hanna, C., Aboualmagd, A., Fraser, S., & Saddik, A. E. (2018) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan7030036 · Cited by 42
Measuring Kinematic Variables in Front Crawl Swimming Using Accelerometers: A Validation Study
Callaway, A. J. (2015) · Sensors · doi:10.3390/s150511363 · Cited by 42
Metadata
- Authors
- Bonato, P.
- Affiliations
- Harvard University (US)
- Corresponding author
- Bonato, Paolo
- ORCID
- Bonato, Paolo
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2005-02-25
- Volume
- 2
- Issue
- 1
- Pages
- 2-2
- ISSN
- 1743-0003 (ISSN-L)
- PMC
- PMC552335
- OpenAlex
- W2095736475
- Cited by
- 385
- References
- 25
- Citations by year
- 2026: 4 · 2025: 18 · 2024: 22 · 2023: 18 · 2022: 20 · 2021: 14 · 2020: 16 · 2019: 17 · 2018: 31 · 2017: 22 · 2016: 23 · 2015: 22 · 2014: 22 · 2013: 20 · 2012: 21
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- wearable sensors, rehabilitation medicine, remote patient monitoring, mobility assessment, physiological signal recording, sensor fusion, quality of life
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review