X-ray computed tomography in life sciences
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Recent developments within micro-computed tomography (μCT) imaging have combined to extend our capacity to image tissue in three (3D) and four (4D) dimensions at micron and sub-micron spatial resolutions, opening the way for virtual histology, live cell imaging, subcellular imaging and correlative microscopy. Pivotal to this has been the development of methods to extend the contrast achievable for soft tissue. Herein, we review the new capabilities within the field of life sciences imaging, and consider how future developments in this field could further benefit the life sciences community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gold Nanoparticles in Biology: Beyond Toxicity to Cellular Imaging
Murphy, C. J., Gole, A. M., Stone, J. W., Sisco, P. N., Alkilany, A. M., Goldsmith, E. C., & Baxter, S. C. (2008) · Accounts of Chemical Research · doi:10.1021/ar800035u · Cited by 1,807
Medical image analysis using convolutional neural networks: a review
Anwar, S. M., Majid, M., Qayyum, A., Awais, M., Alnowami, M., & Khan, M. K. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-1088-1 · Cited by 1,431
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Self-citationMetscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086
Shu, X., Lev-Ram, V., Deerinck, T. J., Qi, Y., Ramko, E. B., Davidson, M. W., Jin, Y., Ellisman, M. H., & Tsien, R. Y. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1001041 · Cited by 827 · cited 1×
“[80]), whilst electron microscopy provides the ultrastructural context.”
BackgroundA guide to light-sheet fluorescence microscopy for multiscale imaging
Power, R. M., & Huisken, J. (2017) · Nature Methods · doi:10.1038/nmeth.4224 · Cited by 636
Dual-Energy CT: General Principles
Johnson, T. R. C. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9116 · Cited by 631 · cited 1×
“4d for imaging feline skin [62], dual energy CT involves imaging tissue first with X-rays of one energy range and then again with X-rays of a different energy range [71].”
BackgroundMetscher, B. D. (2009) · Developmental Dynamics · doi:10.1002/dvdy.21857 · Cited by 607 · cited 3×
“Indium [43] Gallocyanin-chromalum Cell nuclei.”
BackgroundInfluentialGignac, P. M., Kley, N. J., Clarke, J. A., Colbert, M. W., Morhardt, A. C., Cerio, D., Cost, I. N., Cox, P. G., Daza, J. D., Early, C. M., et al. (2016) · Journal of Anatomy · doi:10.1111/joa.12449 · Cited by 541
Deep and fast live imaging with two-photon scanned light-sheet microscopy
Truong, T. V., Supatto, W., Koos, D. S., Choi, J. M., & Fraser, S. E. (2011) · Nature Methods · doi:10.1038/nmeth.1652 · Cited by 489
Withers, P. J. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70305-x · Cited by 371
Self-citationLarge volume serial section tomography by Xe Plasma FIB dual beam microscopy
Burnett, T. L., Kelley, R., Winiarski, B., Contreras, L., Daly, M., Gholinia, A., Burke, M. G., & Withers, P. J. (2016) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.11.001 · Cited by 339
Self-citationElliott, J. C., & Dover, S. D. (1982) · Journal of Microscopy · doi:10.1111/j.1365-2818.1982.tb00376.x · Cited by 272
Altered morphology and 3D architecture of brain vasculature in a mouse model for Alzheimer's disease
Meyer, E. P., Ulmann-Schuler, A., Staufenbiel, M., & Krucker, T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709788105 · Cited by 260
Endrizzi, M. (2017) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.07.036 · Cited by 260
Gignac, P. M., & Kley, N. J. (2014) · Journal of Experimental Zoology Part B: Molecular and Developmental Evolution · doi:10.1002/jez.b.22561 · Cited by 247
Stradiotti, P., Curti, A., Castellazzi, G., & Zerbi, A. (2009) · European Spine Journal · doi:10.1007/s00586-009-0998-5 · Cited by 241
Meir, R., Shamalov, K., Betzer, O., Motiei, M., Horovitz-Fried, M., Yehuda, R., Popovtzer, A., Popovtzer, R., & Cohen, C. J. (2015) · ACS Nano · doi:10.1021/acsnano.5b01939 · Cited by 239
Local Mechanical Stimuli Regulate Bone Formation and Resorption in Mice at the Tissue Level
Schulte, F. A., Ruffoni, D., Lambers, F. M., Christen, D., Webster, D. J., Kuhn, G., & Müller, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062172 · Cited by 231 · cited 2×
“invasive nature of X-ray imaging presents the opportunity to track cells over time in vivo [24], observe changes in a sample over time in response to external stimuli [25, 26] or to use CT correlatively to complement other techniques.”
Methodvan Lenthe, G. H., Hagenmüller, H., Bohner, M., Hollister, S. J., Meinel, L., & Müller, R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.017 · Cited by 214
PAUWELS, E., VAN LOO, D., CORNILLIE, P., BRABANT, L., & VAN HOOREBEKE, L. (2013) · Journal of Microscopy · doi:10.1111/jmi.12013 · Cited by 212
Concentration‐dependent specimen shrinkage in iodine‐enhanced micro CT
Vickerton, P., Jarvis, J., & Jeffery, N. (2013) · Journal of Anatomy · doi:10.1111/joa.12068 · Cited by 189
Scheller, E. L., Troiano, N., VanHoutan, J. N., Bouxsein, M. A., Fretz, J. A., Xi, Y., Nelson, T., Katz, G., Berry, R., Church, C. D., et al. (2014) · Methods in Enzymology · doi:10.1016/b978-0-12-411619-1.00007-0 · Cited by 187
Quantitative analysis of yeast internal architecture using soft X‐ray tomography
Uchida, M., Sun, Y., McDermott, G., Knoechel, C., Le Gros, M. A., Parkinson, D., Drubin, D. G., & Larabell, C. A. (2011) · Yeast · doi:10.1002/yea.1834 · Cited by 187
Soft X-ray tomography and cryogenic light microscopy: the cool combination in cellular imaging
McDermott, G., Le Gros, M. A., Knoechel, C. G., Uchida, M., & Larabell, C. A. (2009) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.08.005 · Cited by 185
In-vivo dark-field and phase-contrast x-ray imaging
Bech, M., Tapfer, A., Velroyen, A., Yaroshenko, A., Pauwels, B., Hostens, J., Bruyndonckx, P., Sasov, A., & Pfeiffer, F. (2013) · Scientific Reports · doi:10.1038/srep03209 · Cited by 176
Buytaert, J., Goyens, J., De Greef, D., Aerts, P., & Dirckx, J. (2014) · Microscopy and Microanalysis · doi:10.1017/s1431927614001329 · Cited by 173
X-Ray Phase Nanotomography Resolves the 3D Human Bone Ultrastructure
Langer, M., Pacureanu, A., Suhonen, H., Grimal, Q., Cloetens, P., & Peyrin, F. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035691 · Cited by 169
Quantitative computed tomography in assessment of osteoporosis
Genant, H. K., Block, J. E., Steiger, P., Glueer, C.-C., & Smith, R. (1987) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(87)80024-7 · Cited by 167
Three-dimensional virtual histology of human cerebellum by X-ray phase-contrast tomography
Töpperwien, M., van der Meer, F., Stadelmann, C., & Salditt, T. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1801678115 · Cited by 160
Cryo-soft X-ray tomography: using soft X-rays to explore the ultrastructure of whole cells
Harkiolaki, M., Darrow, M. C., Spink, M. C., Kosior, E., Dent, K. C., & Duke, E. (2018) · Emerging Topics in Life Sciences · doi:10.1042/etls20170086 · Cited by 152
Chhour, P., Naha, P. C., O'Neill, S. M., Litt, H. I., Reilly, M. P., Ferrari, V. A., & Cormode, D. P. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.009 · Cited by 151
Helliwell, J., Sturrock, C. J., Mairhofer, S., Craigon, J., Ashton, R. W., Miller, T., Whalley, W. R., & Mooney, S. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-14904-w · Cited by 145 · cited 1×
“Time-lapse μCT has also proven useful in the study of developing root systems, resulting in greater understanding of the root–soil interface in different soil types, and unexpectedly demonstrating reduced root–soil contact and increased soil porosity over time [103].”
BackgroundA structure-based extracellular matrix expansion mechanism of fibrous tissue growth
Kalson, N. S., Lu, Y., Taylor, S. H., Starborg, T., Holmes, D. F., & Kadler, K. E. (2015) · eLife · doi:10.7554/elife.05958 · Cited by 141
Completing the picture through correlative characterization
Burnett, T. L., & Withers, P. J. (2019) · Nature Materials · doi:10.1038/s41563-019-0402-8 · Cited by 129
Self-citationSchneider, G., Guttmann, P., Rehbein, S., Werner, S., & Follath, R. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.023 · Cited by 126
Effect of X-ray irradiation on ancient DNA in sub-fossil bones – Guidelines for safe X-ray imaging
Immel, A., Cabec, A. L., Bonazzi, M., Herbig, A., Temming, H., Schuenemann, V. J., Bos, K. I., Langbein, F., Harvati, K., Bridault, A., et al. (2016) · Scientific Reports · doi:10.1038/srep32969 · Cited by 125
SEM sample preparation for cells on 3D scaffolds by freeze‐drying and HMDS
Lee, J. T. Y., & Chow, K. L. (2011) · Scanning · doi:10.1002/sca.20271 · Cited by 124
Cartmell, S. H., Huynh, K. A., Lin, A., Nagaraja, S., & Guldberg, R. E. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20118 · Cited by 113 · cited 3×
“Data can also be correlated across images acquired at different times (temporal correlation), for example to observe mineral formation over time in 3D scaffolds [18], or across multiple length scales using multi-scale CT, sometimes termed zoom tomography, as used to identify the location of macrophages within mouse lu…”
BackgroundSelf-citationWalton, L. A., Bradley, R. S., Withers, P. J., Newton, V. L., Watson, R. E. B., Austin, C., & Sherratt, M. J. (2015) · Scientific Reports · doi:10.1038/srep10074 · Cited by 111 · cited 6×
“6 Gold fiducial marker (Au) in a rat aorta, allowing co-registry of multi-scale CT imaging, reproduced with permission from [34].”
BackgroundMethodInfluentialSelf-citationKoç, M. M., Aslan, N., Kao, A. P., & Barber, A. H. (2019) · Microscopy Research and Technique · doi:10.1002/jemt.23225 · Cited by 110
Serial block face scanning electron microscopy in cell biology: Applications and technology
Smith, D., & Starborg, T. (2018) · Tissue and Cell · doi:10.1016/j.tice.2018.08.011 · Cited by 105
The Site and Nature of Airway Obstruction after Lung Transplantation
Verleden, S. E., Vasilescu, D. M., Willems, S., Ruttens, D., Vos, R., Vandermeulen, E., Hostens, J., McDonough, J. E., Verbeken, E. K., Verschakelen, J., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201310-1894oc · Cited by 104
3D chemical imaging in the laboratory by hyperspectral X-ray computed tomography
Egan, C., Jacques, S. D. M., Wilson, M. D., Veale, M. C., Seller, P., Beale, A. M., Pattrick, R. A. D., Withers, P. J., & Cernik, R. J. (2015) · Scientific Reports · doi:10.1038/srep15979 · Cited by 104
Self-citationElgass, K. D., Smith, E. A., LeGros, M. A., Larabell, C. A., & Ryan, M. T. (2015) · Journal of Cell Science · doi:10.1242/jcs.169136 · Cited by 100 · cited 2×
“with permission from [61], Journal of Cell Science: Elgass KD, Smith EA, LeGros MA, Larabell CA, Ryan MT.”
BackgroundDíaz, A., Malkova, B., Holler, M., Guizar‐Sicairos, M., Lima, E., Panneels, V., Pigino, G., Bittermann, A. G., Wettstein, L., Tomizaki, T., et al. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.10.008 · Cited by 94
Phase-contrast zoom tomography reveals precise locations of macrophages in mouse lungs
Krenkel, M., Markus, M. A., Bartels, M.-B., Dullin, C., Alves, F., & Salditt, T. (2015) · Scientific Reports · doi:10.1038/srep09973 · Cited by 84
In-vitro Optimization of Nanoparticle-Cell Labeling Protocols for In-vivo Cell Tracking Applications
Betzer, O., Meir, R., Dreifuss, T., Shamalov, K., Motiei, M., Shwartz, A., Baranes, K., Cohen, C. J., Shraga‐Heled, N., Ofir, R., et al. (2015) · Scientific Reports · doi:10.1038/srep15400 · Cited by 83
Optical tomography complements light sheet microscopy forin totoimaging of zebrafish development
Bassi, A. L., Schmid, B., & Huisken, J. (2015) · Development · doi:10.1242/dev.116970 · Cited by 77
Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography
Shearer, T., Bradley, R. S., Hidalgo‐Bastida, A., Sherratt, M. J., & Cartmell, S. H. (2016) · Journal of Cell Science · doi:10.1242/jcs.179077 · Cited by 77
Self-citationWehrl, H. F., Bezrukov, I., Wiehr, S., Lehnhoff, M., Fuchs, K., Mannheim, J. G., Quintanilla‐Martínez, L., Kohlhofer, U., Kneilling, M., Pichler, B. J., et al. (2015) · PubMed · doi:10.14670/hh-30.601 · Cited by 77 · cited 1×
“Chemical fixation 10% neutral buffered formalin [54] 1% glutaraldehyde in acetone [55] Copenhagen mix (for plants: 70% absolute alcohol, 2% glycerol, 28% water) [41] • Typically used before heavy metal staining to minimise sample shrinkage • Imaging may be performed in liquid or air (typically ethanol or distilled wat…”
MethodNon-invasive imaging methods applied to neo- and paleo-ontological cephalopod research
Hoffmann, R., Schultz, J. A., Schellhorn, R., Rybacki, E., Keupp, H., Gerden, S. R., Lemanis, R. E., & Zachow, S. (2014) · Biogeosciences · doi:10.5194/bg-11-2721-2014 · Cited by 72
Fernández, M. P., Cipiccia, S., Dall’Ara, E., et al. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.08.012 · Cited by 61
Biological applications of cryo‐soft X‐ray tomography
Duke, E., Dent, K. C., Razi, M., & Collinson, L. (2014) · Journal of Microscopy · doi:10.1111/jmi.12139 · Cited by 59 · cited 5×
“Using soft nCT, cells are typically vitrified, both to embed the cells in a medium and to minimise X-ray damage during imaging [19].”
BackgroundMethodInfluentialX-ray micro-computed tomography (μCT): an emerging opportunity in parasite imaging
O’Sullivan, J. D. B., Behnsen, J., Starborg, T., MacDonald, A. S., Phythian‐Adams, A., Else, K. J., Cruickshank, S. M., & Withers, P. J. (2017) · Parasitology · doi:10.1017/s0031182017002074 · Cited by 58
Self-citationEpah, J., Pálfi, K., Dienst, F. L., Malacarne, P. F., Bremer, R., Salamon, M., Kumar, S., Jo, H., Schürmann, C., & Brandes, R. P. (2018) · Theranostics · doi:10.7150/thno.22610 · Cited by 58 · cited 1×
“Whilst in its infancy, correlative lightsheet fluorescent microscopy (LSFM) and CT imaging can enable the imaging of small and large features, respectively [87].”
BackgroundMyelinated mouse nerves studied by X-ray phase contrast zoom tomography
Bartels, M.-B., Krenkel, M., Cloetens, P., Möbius, W., & Salditt, T. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.11.001 · Cited by 57
Deep learning for image analysis: Personalizing medicine closer to the point of care
Xie, Q. Y., Faust, K., Ommeren, R. V., Sheikh, A., Djuric, U., & Diamandis, P. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1536111 · Cited by 53 · cited 1×
“Looking forwards, segmentation of CT datasets is set to benefit from the emergence of machine learning techniques, which are currently in development within the medical field for disease recognition and to approach personalised medicine [106] as well as in other fields of computer vision analysis [93].”
BackgroundThe use of contrast enhancement techniques in X-ray imaging of lithium–ion battery electrodes
Taiwo, O. O., Finegan, D. P., Gelb, J., Holzner, C., Brett, D. J. L., & Shearing, P. R. (2016) · Chemical Engineering Science · doi:10.1016/j.ces.2016.04.023 · Cited by 52
Application of X‐ray microscopy in analysis of living hydrated cells
Yamamoto, Y., & Shinohara, K. (2002) · The Anatomical Record · doi:10.1002/ar.10166 · Cited by 51
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48 · cited 3×
“4d for imaging feline skin [62], dual energy CT involves imaging tissue first with X-rays of one energy range and then again with X-rays of a different energy range [71].”
Blaser, S. R. G. A., Schlüter, S., & Vetterlein, D. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193669 · Cited by 47
Nondestructive cryomicro-CT imaging enables structural and molecular analysis of human lung tissue
Vasilescu, D. M., Phillion, A. B., Tanabe, N., Kinose, D., Paige, D. F., Kantrowitz, J. J., Liu, G., Liu, H., Fishbane, N., Verleden, S. E., et al. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00838.2016 · Cited by 45
Disney, C., Madi, K., Bodey, A. J., Lee, P. D., Hoyland, J. A., & Sherratt, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-16354-w · Cited by 45
MicroCT versus sTSLIM 3D Imaging of the Mouse Cochlea
Buytaert, J. A. N., Johnson, S. B., Dierick, M., Salih, W. H. M., & Santi, P. A. (2013) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155413478613 · Cited by 45
Novel computed tomography-based tools reliably quantify plant reproductive investment
Staedler, Y. M., Kreisberger, T., Manafzadeh, S., Chartier, M., Handschuh, S., Pamperl, S., Sontag, S., Paun, O., & Schönenberger, J. (2017) · Journal of Experimental Botany · doi:10.1093/jxb/erx405 · Cited by 42
Element-specific spectral imaging of multiple contrast agents: a phantom study
Panta, R. K., Bell, S. T., Healy, J. L., Aamir, R., Bateman, C., Moghiseh, M., Butler, A. P. H., & ANDERSON, N. G. (2018) · Journal of Instrumentation · doi:10.1088/1748-0221/13/02/t02001 · Cited by 41
LI, Z., Ketcham, R. A., Yan, F., Maisano, J. A., & Clarke, J. A. (2016) · Journal of Experimental Zoology Part B Molecular and Developmental Evolution · doi:10.1002/jez.b.22692 · Cited by 36 · cited 1×
“Few studies have considered the merits of different iodine staining protocols, although iodine-ethanol solution has been found to be more effective than iodine potassium iodide at achieving greater contrast [47].”
BackgroundMok, P. L., Leow, S. N., Koh, A. E.-H., Hairul, N. M., Ding, S. L. S., Luu, C. D., Ruhaslizan, R., Wong, H., Halim, W. H. W. A., Ng, M. H., et al. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18020345 · Cited by 35
Zehbe, R., Riesemeier, H., Kirkpatrick, C. J., & Brochhausen, C. (2012) · Micron · doi:10.1016/j.micron.2012.05.001 · Cited by 33
Mürer, F. K., Sanchez, S., Álvarez-Murga, M., Michiel, M. D., Pfeiffer, F., Bech, M., & Breiby, D. W. (2018) · Scientific Reports · doi:10.1038/s41598-018-28269-1 · Cited by 33
Oliveira-Filho, E. C., Filho, J. S., Novais, L. A., Peternele, W. S., Azevedo, R. B., & Grisólia, C. K. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-6998-1 · Cited by 32
3D X-Ray Nanotomography of Cells Grown on Electrospun Scaffolds
Bradley, R. S., Robinson, I. K., & Yusuf, M. (2016) · Macromolecular Bioscience · doi:10.1002/mabi.201600236 · Cited by 28
Correlative multiscale tomography of biological materials
Bradley, R. S., & Withers, P. J. (2016) · MRS Bulletin · doi:10.1557/mrs.2016.137 · Cited by 26 · cited 1×
“Similarly, correlative CT exploits multiple techniques or imaging modalities to obtain different types of information from a given ROI or volume of interest [81].”
BackgroundSelf-citationSilva, J. M. D. S. E., Utsch, J., Kimm, M. A., Allner, S., Epple, M., Achterhold, K., & Pfeiffer, F. (2017) · Scientific Reports · doi:10.1038/s41598-017-17064-z · Cited by 24 · cited 1×
“Staining duration is sample- and stain-specific; full staining is achieved in murine heart and lungs in just 3 h using an iodine or gadolinium stain [48], whereas larger specimens, such as alligator and emu heads, can require weeks of staining [28].”
MethodShort bursts of cyclic mechanical compression modulate tissue formation in a 3D hybrid scaffold
Brunelli, M., Perrault, C. M., & Lacroix, D. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.03.008 · Cited by 23
Jacob, D. E., Ruthensteiner, B., Trimby, P. W., Henry, H., Martha, S. O., Leitner, J., Otter, L. M., & Scholz, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-47848-4 · Cited by 21
X-ray phase contrast imaging of the bone–cartilage interface
Ismail, E. C., Kaabar, W., Garrity, D. J., Gundogdu, O., Bunk, O., Pfeiffer, F., Farquharson, M., & Bradley, D. A. (2009) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2009.09.042 · Cited by 20
Marxen, J. C., Prymak, O., Beckmann, F., Neues, F., & Epple, M. (2007) · Journal of Molluscan Studies · doi:10.1093/mollus/eym044 · Cited by 19 · cited 1×
“Image in b reproduced from [7], Marxen JC, Prymark O, Beckmann F, Neues F, Epple M.”
BackgroundAstolfo, A., Qie, F., Kibleur, A., Hao, X., Menk, R. H., Arfelli, F., Rigon, L., Hinton, T. M., Wickramaratna, M., Tan, T., et al. (2014) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2014.06.008 · Cited by 19
Experimental steering of electron microscopy studies using prior X-ray computed tomography
Starborg, T., O’Sullivan, J. D. B., Carneiro, C. M., Behnsen, J., Else, K. J., Grencis, R. K., & Withers, P. J. (2019) · Ultramicroscopy · doi:10.1016/j.ultramic.2019.03.002 · Cited by 18
Self-citationMitchell, R. L., Coleman, M., Davies, P., North, L., Pope, E. C., Pleydell‐Pearce, C., Harris, W., & Johnston, R. E. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0218 · Cited by 18
Lin, Q., Andrew, M. G., Thompson, W., Blunt, M. J., & Bijeljic, B. (2018) · Advances in Water Resources · doi:10.1016/j.advwatres.2018.03.007 · Cited by 16
Optimal Iodine Staining of Cardiac Tissue for X-Ray Computed Tomography
Butters, T. D., Castro, S. J., Lowe, T., Zhang, Y., Lei, M., Withers, P. J., & Zhang, H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105552 · Cited by 16
Self-citation3D vessel-wall virtual histology of whole-body perfused mice using a novel heavy element stain
Dunmore‐Buyze, J., Cruje, C., Nong, Z., Lee, J. J., Kiernan, J. A., Pickering, J. G., & Drangova, M. (2019) · Scientific Reports · doi:10.1038/s41598-018-36905-z · Cited by 10
Post-processing techniques for making reliable measurements from curve-skeletons
Bradley, R. S., & Withers, P. J. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.03.008 · Cited by 10
Self-citationRawson, S. D., Shearer, T., Lowe, T., O’Brien, M., Wong, J. K. F., Margetts, L., & Cartmell, S. H. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b09700 · Cited by 7 · cited 3×
“invasive nature of X-ray imaging presents the opportunity to track cells over time in vivo [24], observe changes in a sample over time in response to external stimuli [25, 26] or to use CT correlatively to complement other techniques.”
BackgroundMethodSelf-citationLi, Z., Yan, F., Ketcham, R. A., Colbert, M. W., & Clarke, J. A. (2018) · Palaeoworld · doi:10.1016/j.palwor.2018.10.004 · Cited by 4 · cited 1×
“Mathematical models are being developed to predict the staining uptake within tissues, based on mass transfer theory [49].”
BackgroundMustansar, Z., McDonald, S. A., Sellers, W. I., Manning, P. L., Lowe, T., Withers, P. J., & Margetts, L. (2017) · PeerJ · doi:10.7717/peerj.3416 · Cited by 3
Self-citation
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Self-citationPeddie, C. J., Genoud, C., Kreshuk, A., Meechan, K., Micheva, K. D., Narayan, K., Pape, C., Parton, R. G., Schieber, N. L., Schwab, Y., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00131-9 · Cited by 225
Scharf, J., Chouchane, M., Finegan, D. P., Lu, B., Redquest, C., Kim, M.-C., Yao, W., Franco, A. A., Gostovic, D., Liu, Z., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01081-9 · Cited by 219
Metadata
- Authors
- Rawson, S. D., Maksimcuka, J., Withers, P. J., & Cartmell, S. H.
- Venue
- BMC Biology
- Published
- 2020-02-27
- Volume
- 18
- Issue
- 1
- Pages
- 21-21
- ISSN
- 1741-7007 (ISSN-L)
- OpenAlex
- W3012755458
- Cited by
- 164
- References
- 89
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.