Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Blood pressure is a critical bio-signal and its importance has been increased with the aged society and the growth of cardiovascular disease population. However, most of hypertensive patients have been suffered the inconvenience in monitoring blood pressure in daily life because the measurement of the blood pressure depends on the cuff-based technique. Nowadays there are many trials to measure blood pressure without cuff, especially, photoplethysmography (PPG) based research is carried out in various ways. METHODS: Our research is designed to hypothesis the relationship between vessel wall movement and pressure-flow relationship of PPG and to validate its appropriateness by experimental methods. PPG waveform is simplified by approximate model, and then it is analyzed as the velocity and the acceleration of blood flow using the derivatives of PPG. Finally, we develop pressure index (PI) as an estimation factor of blood pressure by combining of statistically significant segments of photoplethysmographic waveform. RESULTS: Twenty-five subjects were participated in the experiment. As a result of simulation, correlation coefficients between developed PI and blood pressure were represented with R = 0.818, R = 0.827 and R = 0.615 in systolic blood pressure, pulse pressure and mean arterial pressure, respectively, and both of result showed the meaningful statistically significance (P < 0.05). CONCLUSIONS: Current study can estimate only the relative variation of blood pressure but could not find the absolute pressure value. Moreover, proposed index has the limitation of diastolic pressure tracing. However, the result shows that the proposed PI is statistically significantly correlated with blood pressures, and it suggests that the proposed PI as a promising additional parameter for the cuff less blood pressure monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202 · cited 2×
“Morphological analysis of PPG has been applied in vascular assessment such as vascular disease [9–11], aging [7, 8, 12, 13], and arterial compliance [14].”
MethodResultWearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor
Shaltis, P. A., Reisner, A., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260027 · Cited by 77 · cited 1×
“Modified volume-oscillometric technique [25, 26] and hydrostatic method [27] is another BP estimation technique based on PPG sensor and two micro-electro mechanical systems (MEMS) accelerometers.”
MethodWippermann, C. F., Schranz, D., & Huth, R. G. (1995) · Journal of Clinical Monitoring · doi:10.1007/bf01616991 · Cited by 36
Cited by
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Self-citationFlexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China
Liang, Y., Chen, Z., Liu, G., & Elgendi, M. (2018) · Scientific Data · doi:10.1038/sdata.2018.20 · Cited by 215
Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S. (2022) · Healthcare · doi:10.3390/healthcare10030547 · Cited by 188
Khalid, S. G., Zhang, J., Chen, F., & Zheng, D. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1548647 · Cited by 171
“Some studies only included normotensive subjects [10, 17, 37].”
Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring
Hosanee, M., Chan, G., Welykholowa, K., Cooper, R., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030723 · Cited by 136
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70
Metadata
- Authors
- Shin, H., & Min, S. D.
- Venue
- BioMedical Engineering OnLine
- Published
- 2017-01-10
- Volume
- 16
- Issue
- 1
- Pages
- 10-10
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2576387397
- Cited by
- 142
- References
- 7
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.