Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Open accessThe DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Gait disorders can reduce the quality of life for people with neuromuscular impairments. Therefore, walking recovery is one of the main priorities for counteracting sedentary lifestyle, reducing secondary health conditions and restoring legged mobility. At present, wearable powered lower-limb exoskeletons are emerging as a revolutionary technology for robotic gait rehabilitation. This systematic review provides a comprehensive overview on wearable lower-limb exoskeletons for people with neuromuscular impairments, addressing the following three questions: (1) what is the current technological status of wearable lower-limb exoskeletons for gait rehabilitation?, (2) what is the methodology used in the clinical validations of wearable lower-limb exoskeletons?, and (3) what are the benefits and current evidence on clinical efficacy of wearable lower-limb exoskeletons? We analyzed 87 clinical studies focusing on both device technology (e.g., actuators, sensors, structure) and clinical aspects (e.g., training protocol, outcome measures, patient impairments), and make available the database with all the compiled information. The results of the literature survey reveal that wearable exoskeletons have potential for a number of applications including early rehabilitation, promoting physical exercise, and carrying out daily living activities both at home and the community. Likewise, wearable exoskeletons may improve mobility and independence in non-ambulatory people, and may reduce secondary health conditions related to sedentariness, with all the advantages that this entails. However, the use of this technology is still limited by heavy and bulky devices, which require supervision and the use of walking aids. In addition, evidence supporting their benefits is still limited to short-intervention trials with few participants and diversity among their clinical protocols. Wearable lower-limb exoskeletons for gait rehabilitation are still in their early stages of development and randomized control trials are needed to demonstrate their clinical efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lack of Exercise Is a Major Cause of Chronic Diseases
Booth, F. W., Roberts, C. K., & Laye, M. J. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110025 · Cited by 2,575
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Sex Differences in Stroke Epidemiology: A Systematic Review
Appelros, P., Stegmayr, B., & Terént, A. (2009) · Stroke · doi:10.1161/strokeaha.108.540781 · Cited by 1,027
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Anatomical Data for Analyzing Human Motion
Plagenhoef, S., Evans, F. G., & Abdelnour, T. (1983) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1983.10605290 · Cited by 647
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Werner, C., Kugler, J., Pohl, M., & Elsner, B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub4 · Cited by 564
Chronic complications of spinal cord injury
Sezer, N. (2015) · World Journal of Orthopedics · doi:10.5312/wjo.v6.i1.24 · Cited by 525
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
Rehabilitation robots for the treatment of sensorimotor deficits: a neurophysiological perspective
Gassert, R., & Dietz, V. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0383-x · Cited by 440
Benabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404
Driven gait orthosis for improvement of locomotor training in paraplegic patients
Colombo, G., Wirz, M., & Dietz, V (2001) · Spinal Cord · doi:10.1038/sj.sc.3101154 · Cited by 396
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Who wants to walk? Preferences for recovery after SCI: a longitudinal and cross-sectional study
Ditunno, P. L., Patrick, M., Stineman, M., & Ditunno, J. F. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102172 · Cited by 332
Miller, L., Zimmermann, A., & Herbert, W. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s103102 · Cited by 313
Recovery from a Spinal Cord Injury: Significance of Compensation, Neural Plasticity, and Repair
Curt, A., Van Hedel, H. J. A., Klaus, D., Dietz, V., & for the EM-SCI Study Group (2008) · Journal of Neurotrauma · doi:10.1089/neu.2007.0468 · Cited by 308
Annals of Clinical Laboratory Science
Kay, H. E. M. (1973) · Journal of Clinical Pathology · doi:10.1136/jcp.26.1.82-c · Cited by 303
Biofeedback for robotic gait rehabilitation
Lünenburger, L., Colombo, G., & Riener, R. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-1 · Cited by 297
A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Physical inactivity: associated diseases and disorders.
Knight, J. A. (2012) · PubMed · Cited by 286
Mahlknecht, P., Kiechl, S., Bloem, B. R., Willeit, J., Scherfler, C., Gasperi, A., Rungger, G., Poewe, W., & Seppi, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0069627 · Cited by 271
Gait rehabilitation machines based on programmable footplates
Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-2 · Cited by 256
Bruni, M. F., Melegari, C., De Cola, M. C., Bramanti, A., Bramanti, P., & Calabrò, R. S. (2018) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.10.048 · Cited by 240
Rupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., & Virk, G. S. (2017) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881417743554 · Cited by 228
Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Physical Activity Levels Are Low in Free‐Living Adults with Chronic Paraplegia
Buchholz, A. C., McGillivray, C. F., & Pencharz, P. B. (2003) · Obesity Research · doi:10.1038/oby.2003.79 · Cited by 220
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
Powered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
Robotic Rehabilitation and Spinal Cord Injury: a Narrative Review
Mekki, M., Delgado, A. D., Fry, A., Putrino, D., & Huang, V. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0642-3 · Cited by 216
Farris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208
Robotic exoskeletons: The current pros and cons
Gorgey, A. S. (2018) · World Journal of Orthopedics · doi:10.5312/wjo.v9.i9.112 · Cited by 205
Schmidt, K., Duarte, J. E., Grimmer, M., Sancho-Puchades, A., Wei, H., Easthope, C. S., & Riener, R. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00057 · Cited by 202
Mobility Outcomes Following Five Training Sessions with a Powered Exoskeleton
Hartigan, C., Kandilakis, C., Dalley, S., Clausen, M., Wilson, E., Morrison, S., Etheridge, S., & Farris, R. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-93 · Cited by 201
Jensen, M. P., Truitt, A. R., Schomer, K. G., Yorkston, K. M., Baylor, C., & Molton, I. R. (2013) · Spinal Cord · doi:10.1038/sc.2013.112 · Cited by 199
Kozlowski, A., Bryce, T., & Dijkers, M. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-110 · Cited by 193
Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton
del-Ama, A. J., Gil-Agudo, Á., Pons, J. L., & Moreno, J. C. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-27 · Cited by 190
Kolakowsky-Hayner, S. A. (2013) · Journal of Spine · doi:10.4172/2165-7939.s4-003 · Cited by 190
Buesing, C., Fisch, G., O’Donnell, M., Shahidi, I., Thomas, L., Mummidisetty, C. K., Williams, K. J., Takahashi, H., Rymer, W. Z., & Jayaraman, A. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0062-0 · Cited by 187
Lerner, Z. F., Damiano, D. L., & Bulea, T. C. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aam9145 · Cited by 187
Calabrò, R. S., Naro, A., Russo, M., Bramanti, P., Carioti, L., Balletta, T., Buda, A., Manuli, A., Filoni, S., & Bramanti, A. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0377-8 · Cited by 185
Development of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333698 · Cited by 182
A portable powered ankle-foot orthosis for rehabilitation
Shorter, K. A., Kogler, G. F., Loth, E., Durfee, W. K., & Hsiao-Wecksler, E. T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.04.0054 · Cited by 180
Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346193 · Cited by 177
Bach Baunsgaard, C., Vig Nissen, U., Katrin Brust, A., Frotzler, A., Ribeill, C., Kalke, Y.-B., León, N., Gómez, B., Samuelsson, K., Antepohl, W., et al. (2018) · Spinal Cord · doi:10.1038/s41393-017-0013-7 · Cited by 177
Physical Disability and Obesity
Liou, T.-H., Pi-Sunyer, F. X., & Laferrere, B. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00110.x · Cited by 176
Tsukahara, A., Hasegawa, Y., Eguchi, K., & Sankai, Y. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2364618 · Cited by 174
Benson, I., Hart, K., Tussler, D., & van Middendorp, J. J. (2016) · Clinical Rehabilitation · doi:10.1177/0269215515575166 · Cited by 174
Risk management and regulations for lower limb medical exoskeletons: a review
He, Y., Eguren, D., Luu, T. P., & Contreras-Vidal, J. L. (2017) · Medical Devices Evidence and Research · doi:10.2147/mder.s107134 · Cited by 174
Exercise after spinal cord injury as an agent for neuroprotection, regeneration and rehabilitation
Sandrow-Feinberg, H. R., & Houlé, J. D. (2015) · Brain Research · doi:10.1016/j.brainres.2015.03.052 · Cited by 173
Lajeunesse, V., Vincent, C., Routhier, F., Careau, E., & Michaud, F. (2016) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2015.1080766 · Cited by 170
Use of Prolonged Standing for Individuals With Spinal Cord Injuries
Eng, J. J., Levins, S. M., Townson, A. F., Mah-Jones, D., Bremner, J., & Huston, G. (2001) · Physical Therapy · doi:10.1093/ptj/81.8.1392 · Cited by 168
Tefertiller, C., Hays, K., Jones, J., Jayaraman, A., Hartigan, C., Bushnik, T., & Forrest, G. F. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci17-00014 · Cited by 165
Lerner, Z. F., Damiano, D. L., Park, H., Gravunder, A. J., & Bulea, T. C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2595501 · Cited by 164
Veale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
Näf, M. B., Junius, K., Rossini, M., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042523 · Cited by 158
Prevalence of gait disorders in hospitalized neurological patients
Stolze, H., Klebe, S., Baecker, C., Zechlin, C., Friege, L., Pohle, S., & Deuschl, G. (2005) · Movement Disorders · doi:10.1002/mds.20266 · Cited by 154
Yeung, L.-F., Ockenfeld, C., Pang, M., Wai, H., Soo, O.-Y., Li, S.-W., & Tong, R. K. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0394-7 · Cited by 152
Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., et al. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8461046 · Cited by 145
Goal Priorities Identified through Client-Centred Measurement in Individuals with Chronic Stroke
Harris, J. E., & Eng, J. J. (2004) · Physiotherapy Canada · doi:10.2310/6640.2004.00017 · Cited by 144
Federici, S., Meloni, F., Bracalenti, M., & Filippis, M. L. D. (2015) · Neurorehabilitation · doi:10.3233/nre-151265 · Cited by 143
Overexpression of ANXA1 in Penile Carcinomas Positive for High-Risk HPVs
Calmon, M. F., Mota, M. T. D. O., Babeto, É., Candido, N. M., Girol, A. P., Mendiburu, C. F., Bonilha, J. L., Silvestre, R. V. D., Rosa, B. M., Thomé, J. A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053260 · Cited by 136
Durandau, G., Farina, D., Asín-Prieto, G., Dimbwadyo-Terrer, I., Lara, S. L., Pons, J. L., Moreno, J. C., & Sartori, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0559-z · Cited by 136
Yang, A. H., Asselin, P. K., Knezevic, S., Kornfeld, S. D., & Spungen, A. M. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-100 · Cited by 125
Technologies for Powered Ankle-Foot Orthotic Systems: Possibilities and Challenges
Shorter, K. A., Xia, J., Hsiao‐Wecksler, E. T., Durfee, W. K., & Kogler, G. F. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2174799 · Cited by 120
A wearable exoskeleton suit for motion assistance to paralysed patients
Chen, B., Zhong, C.-H., Zhao, X., Ma, H., Guan, X., Li, X., Liang, F., Cheng, J. C. Y., Qin, L., Law, S. W., et al. (2017) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2017.02.007 · Cited by 118
Mehrholz, J., Harvey, L. A., Thomas, S., & Elsner, B. (2017) · Spinal Cord · doi:10.1038/sc.2017.31 · Cited by 118
Fehlings, M. G., Tetreault, L. A., Aarabi, B., Anderson, P. A., Arnold, P. M., Brodke, D. S., Chiba, K., Dettori, J. R., Furlan, J. C., Harrop, J. S., et al. (2017) · Global Spine Journal · doi:10.1177/2192568217701910 · Cited by 118
Fisahn, C., Aach, M., Jansen, O., Moisi, M. D., Mayadev, A. S., Pagarigan, K. T., Dettori, J. R., & Schildhauer, T. A. (2016) · Global Spine Journal · doi:10.1055/s-0036-1593805 · Cited by 106
Stride management assist exoskeleton vs functional gait training in stroke: A randomized trial
Jayaraman, A., O’Brien, M. K., Madhavan, S., Mummidisetty, C. K., Roth, H., Hohl, K., Tapp, A., Brennan, K., Kocherginsky, M., Williams, K. J., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000006782 · Cited by 105
Prevalence of Obesity After Spinal Cord Injury
Gorgey, A., & Gater, D. (2007) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1204-1 · Cited by 104
Baunsgaard, C. B., Nissen, U., Brust, A., Frotzler, A., Ribeill, C., Kalke, Y., León, N., Gómez, B., Samuelsson, K., Antepohl, W., et al. (2018) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2372 · Cited by 102
Strickland, E. (2012) · IEEE Spectrum · doi:10.1109/mspec.2012.6117830 · Cited by 101
Contreras-Vidal, J. L., & Grossman, R. G. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609816 · Cited by 97
Design and Actuator Selection of a Lower Extremity Exoskeleton
Önen, Ü., Botsalı, F. M., Kalyoncu, M., Tınkır, M., Yılmaz, N., & Şahin, Y. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2250295 · Cited by 97
Molteni, F., Gasperini, G., Gaffuri, M., Colombo, M. D. H. P., Giovanzana, C., Lorenzon, C., Farina, N., Cannaviello, G., Scarano, S., Proserpio, D. M., et al. (2017) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.17.04591-9 · Cited by 95
McGibbon, C. A., Sexton, A., Jayaraman, A., Deems-Dluhy, S., Gryfe, P., Novak, A. C., Dutta, T., Fabara, E. E., Adans-Dester, C. P., & Bonato, P. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0468-6 · Cited by 94
Control and implementation of a powered lower limb orthosis to aid walking in paraplegic individuals
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975481 · Cited by 88
Effect of Spatial Smoothing on Task fMRI ICA and Functional Connectivity
Chen, Z., & Calhoun, V. D. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00015 · Cited by 86
Robotics for Lower Limb Rehabilitation
Esquenazi, A., & Talaty, M. C. (2019) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2018.12.012 · Cited by 83
From cortex to cord: motor circuit plasticity after spinal cord injury
Martinez, M., & Brown, A. R. (2019) · Neural Regeneration Research · doi:10.4103/1673-5374.262572 · Cited by 83
Sale, P., Russo, E. F., Russo, M., Masiero, S., Piccione, F., Calabrò, R. S., & Filoni, S. (2016) · BMC Neurology · doi:10.1186/s12883-016-0536-0 · Cited by 79
Gagnon, D. H., Escalona, M. J., Vermette, M., Carvalho, L. P., Karelis, A. D., Duclos, C., & Aubertin‐Leheudre, M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0354-2 · Cited by 74
Carpino, G., Pezzola, A., Urbano, M., & Guglielmelli, E. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/7492024 · Cited by 74
Alamro, R. A., Chisholm, A. E., Williams, A. M. M., Carpenter, M. G., & Lam, T. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0453-0 · Cited by 73
Chang, S., Afzal, T., Berliner, J., & Francisco, G. E. (2018) · Pilot and Feasibility Studies · doi:10.1186/s40814-018-0247-y · Cited by 72
Perspectives of people with spinal cord injury learning to walk using a powered exoskeleton
Manns, P. J., Hurd, C., & Yang, J. F. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0565-1 · Cited by 71
Platz, T., Gillner, A., Nicole, B., Kroll, S., & Roschka, S. (2016) · BioMed Research International · doi:10.1155/2016/8459018 · Cited by 68
Pasma, J. H., van Kordelaar, J., de Kam, D., Weerdesteyn, V., Schouten, A. C., & van der Kooij, H. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0299-x · Cited by 66
Ueba, T., Hamada, O., Ogata, T., Inoue, T., Shiota, E., & Sankai, Y. (2013) · Neurologia medico-chirurgica · doi:10.2176/nmc.53.287 · Cited by 65
Juszczak, M., Gallo, E., & Bushnik, T. L. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci17-00055 · Cited by 65
Training Persons with Spinal Cord Injury to Ambulate Using a Powered Exoskeleton
Asselin, P. K., Avedissian, M., Knezevic, S., Kornfeld, S. D., & Spungen, A. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54071 · Cited by 64
Wu, C.-H., Mao, H., Hu, J., Wang, T.-Y., Tsai, Y.-J., & Hsu, W. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0355-1 · Cited by 62
Wearable Power-Assist Locomotor (WPAL) for supporting upright walking in persons with paraplegia
Tanabe, S., Hirano, S., & Saitoh, E. (2013) · Neurorehabilitation · doi:10.3233/nre-130932 · Cited by 61
Tan, C. K., Kadone, H., Watanabe, H., Marushima, A., Yamazaki, M., Sankai, Y., & Suzuki, K. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00276 · Cited by 61
Tamburella, F., Moreno, J. C., Valenzuela, D. S. H., Pisotta, I., Iosa, M., Cincotti, F., Mattia, D., Pons, J. L., & Molinari, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0558-0 · Cited by 59
Neural Decoding of Robot-Assisted Gait During Rehabilitation After Stroke
Contreras-Vidal, J. L., Bôrtole, M., Zhu, F., Nathan, K., Venkatakrishnan, A., Francisco, G. E., Soto, R., & Pons, J. L. (2018) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000914 · Cited by 52
Robot-assisted training using Hybrid Assistive Limb® for cerebral palsy
Matsuda, M., Iwasaki, N., Mataki, Y., Mutsuzaki, H., Yoshikawa, K., Takahashi, K., Enomoto, K., Sano, K., Kubota, A., Nakayama, T., et al. (2018) · Brain and Development · doi:10.1016/j.braindev.2018.04.004 · Cited by 51
A muscle-driven approach to restore stepping with an exoskeleton for individuals with paraplegia
Chang, S. R., Nandor, M. J., Li, L., Kobetic, R., Foglyano, K. M., Schnellenberger, J. R., Audu, M. L., Pinault, G., Quinn, R. D., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0258-6 · Cited by 49
State of the Art: Bipedal Robots for Lower Limb Rehabilitation
Yang, X., She, H., Lu, H., Fukuda, T., & Shen, Y. (2017) · Applied Sciences · doi:10.3390/app7111182 · Cited by 48
Chisholm, A. E., Alamro, R. A., Williams, A. M. M., & Lam, T. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0236-z · Cited by 45
Goffredo, M., Iacovelli, C., Russo, E. F., Pournajaf, S., Blasi, C. D., Galafate, D., Pellicciari, L., Agosti, M., Filoni, S., Aprile, I. G., et al. (2019) · Applied Sciences · doi:10.3390/app9132627 · Cited by 44
EUROBENCH: Preparing Robots for the Real World
Torricelli, D., & Pons, J. L. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01887-0_72 · Cited by 39
Use of Hybrid Assistive Limb (HAL®) for a postoperative patient with cerebral palsy: a case report
Mataki, Y., Kamada, H., Mutsuzaki, H., Shimizu, Y., Takeuchi, R., Mizukami, M., Yoshikawa, K., Takahashi, K., Matsuda, M., Iwasaki, N., et al. (2018) · BMC Research Notes · doi:10.1186/s13104-018-3311-z · Cited by 34
Ekelem, A., & Goldfarb, M. T. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00374 · Cited by 32
Shimizu, Y., Kadone, H., Kubota, S., Suzuki, K., Abe, T., Ueno, T., Soma, Y., Sankai, Y., Hada, Y., & Yamazaki, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00649 · Cited by 30
Improved walking ability with wearable robot-assisted training in patients suffering chronic stroke
Li, L., Ding, L., Chen, N., Mao, Y., Huang, D., & Li, L. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151320 · Cited by 29
Evaluation of robot-assisted gait training using integrated biofeedback in neurologic disorders
Stoller, O., Waser, M., Stammler, L., & Schuster‐Amft, C. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.031 · Cited by 27
Real-time biofeedback device for gait rehabilitation of post-stroke patients
Khoo, I., Marayong, P., Krishnan, V., Balagtas, M. N., Rojas, O., & Leyba, K. A. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-017-0036-1 · Cited by 27
Predictors of exoskeleton motor learning in spinal cord injured patients
van Dijsseldonk, R. B., Rijken, H., van Nes, I. J. W., van de Meent, H., & Keijsers, N. (2019) · Disability and Rehabilitation · doi:10.1080/09638288.2019.1689578 · Cited by 23
Tsukahara, A., Yoshida, K., Matsushima, A., Ajima, K., Kuroda, C., Mizukami, N., & Hashimoto, M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0425-4 · Cited by 21
Robot-Aided Gait Training in an Individual With Chronic Spinal Cord Injury: A Case Study
Bishop, L., Stein, J. M., & Wong, C. K. (2012) · Neurology Report · doi:10.1097/npt.0b013e3182624c87 · Cited by 18
Lower extremity robotic exoskeleton training: Case studies for complete spinal cord injury walking
Lemaire, E. D., Smith, A., Herbert-Copley, A., & Sreenivasan, V. A. (2017) · Neurorehabilitation · doi:10.3233/nre-171461 · Cited by 18
Kawasaki, S., Ohata, K., Tsuboyama, T., Sawada, Y., & Higashi, Y. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009264 · Cited by 16
Cited by
Interactive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“Several reviews have also been published on LLERs [9], [37], [38], [39], [40], [41], [42].”
BackgroundBen Chaabane, N., Conze, P.-H., Lempereur, M., Quellec, G., Rémy-Néris, O., Brochard, S., Cochener, B., & Lamard, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-49883-8 · Cited by 24
A compliant metastructure design with reconfigurability up to six degrees of freedom
Yang, H., Patel, D. K., Johnson, T., Zhong, K., Olson, G., Majidi, C., Islam, M. F., Zhang, T., & Yao, L. (2025) · Nature Communications · doi:10.1038/s41467-024-55591-2 · Cited by 17
Metadata
- Authors
- Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2021-02-01
- Volume
- 18
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W3107239624
- Cited by
- 435
- References
- 123
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.