Glucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Background: Glycaemic control of Type 1 Diabetes Mellitus (T1DM) remains a challenge due to hypoglycaemic episodes and the burden of insulin self-management. Advancements have been made with the development of automated insulin delivery (AID) devices, yet, previous reviews have only assessed the use of AID over days or weeks, and potential benefits with longer time of AID use in this population remain unclear. Methods: We performed a systematic review and meta-analysis of randomised controlled trials comparing AID (hybrid and fully closed-loop systems) to usual care (sensor augmented pumps, multiple daily insulin injections, continuous glucose monitoring and predictive low-glucose suspend) for adults and children with T1DM with a minimum duration of 3 months. We searched PubMed, Embase, Cochrane Central, and Clinicaltrials.gov for studies published up until April 4, 2023. Main outcomes included time in range 70–180 mg/dL as the primary outcome, and change in HbA1c (%, mmol/mol), glucose variability, and psychosocial impact (diabetes distress, treatment satisfaction and fear of hypoglycaemia) as secondary outcomes. Adverse events included diabetic ketoacidosis (DKA) and severe hypoglycaemia. Statistical analyses were conducted using mean differences and odds ratios. Sensitivity analyses were performed according to age, study duration and type of AID device. The protocol was registered in PROSPERO, CRD42022366710. Results: We identified 25 comparisons from 22 studies (six crossover and 16 parallel designs) including a total of 2376 participants (721 in adult studies, 621 in paediatric studies, and 1034 in combined studies) which were eligible for analysis. Use of AID devices ranged from 12 to 96 weeks. Patients using AID had 10.87% higher time in range [95% CI 9.38 to 12.37; p < 0.0001, I 2 = 87%) and 0.37% (4.77 mmol/mol) lower HbA1c (95% CI − 0.49% (− 6.39 mmol/mol) to – 0.26 (− 3.14 mmol/mol); p < 0·0001, I 2 = 77%]. AID systems decreased night hypoglycaemia, time in hypoglycaemia and hyperglycaemia and improved patient distress, with no increase in the risk of DKA or severe hypoglycaemia. No difference was found regarding treatment satisfaction or fear of hypoglycaemia. Among children, there was no difference in glucose variability or time spent in hypoglycaemia between the use of AID systems or usual care. In sensitivity analyses, results remained consistent with the overall analysis favouring AID. Conclusion: The use of AID systems over 12 weeks, regardless of technical or clinical differences, improved glycaemic outcomes and diabetes distress without increasing the risk of adverse events in adults and children with T1DM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 34,787
Wan, X., Wang, W., Liu, J., & Tong, T. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-135 · Cited by 11,735 · cited 1×
“For missing means data, we used the formula proposed by Wan et al. [19] using medians and interquartile ranges as recommended by the Cochrane Collaboration [18].”
MethodCumpston, M., Li, T., Page, M. J., Chandler, J., Welch, V. A., Higgins, J. P., & Thomas, J. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.ed000142 · Cited by 7,218
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“Although HbA1c is currently the metric of choice by most endocrinology and diabetes societies [54, 55], TIR and HbA1c should be used as complementary parameters to guide care [56] and allow evaluation in clinical research [57].”
BackgroundState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831 · cited 1×
“Although HbA1c is currently the metric of choice by most endocrinology and diabetes societies [54, 55], TIR and HbA1c should be used as complementary parameters to guide care [56] and allow evaluation in clinical research [57].”
BackgroundValidation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793 · cited 1×
“Although HbA1c is currently the metric of choice by most endocrinology and diabetes societies [54, 55], TIR and HbA1c should be used as complementary parameters to guide care [56] and allow evaluation in clinical research [57].”
BackgroundLong-term Glycemic Variability and Risk of Adverse Outcomes: A Systematic Review and Meta-analysis
Gorst, C., Kwok, C. S., Aslam, S., Buchan, I., Kontopantelis, E., Myint, P. K., Heatlie, G., Loke, Y., Rutter, M. K., & Mamas, M. A. (2015) · Diabetes Care · doi:10.2337/dc15-1188 · Cited by 530
Buchberger, B., Huppertz, H., Krabbe, L., Lux, B., Mattivi, J. T., & Siafarikas, A. (2016) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2016.04.019 · Cited by 471 · cited 1×
“A high cognitive load for T1DM patients and care team is required and previous studies show distress or depressive symptoms in up to 40% of patients [53].”
BackgroundThe relationship of hemoglobin A1C to time-in-range in patients with diabetes
Vigersky, R. A., & McMahon, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0310 · Cited by 464
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · cited 3×
“Most studies in our analysis did not assess fully automated systems [8, 29, 31–38, 40– 46], which still require manual Finally, this was the first meta-analysis to assess how long-term use of AID impacts patient-reported outcomes with a considerable number of studies.”
BackgroundMethodTauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440 · cited 1×
“…[28, 34, 43, 44, 46]; five (n = 605) assessed t:slim X2 with Control IQ (Tandem) [33, 35, 36, 38, 45]; two (n = 144) assessed Modified Florence [30, 31]; two (n = 119) assessed MiniMed 780G (Medtronic) [8, 29]; two assessed openAPS (n = 129) [34, 41]; one (n = 63) assessed DBLG1 (Dbl-diabetes)…”
Benhamou, P.-Y., Franc, S., Reznik, Y., Thivolet, C., Schaepelynck, P., Renard, E., Guerci, B., Chaillous, L., Lukas-Croisier, C., Jeandidier, N., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30003-2 · Cited by 217
Multicenter, randomized trial of a bionic pancreas in type 1 diabetes
Bionic Pancreas Research Group (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205225 · Cited by 216
Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C., Evans, M., Ré, R., de Portu, S., Vorrink, L., Shin, J., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00212-1 · Cited by 204 · cited 3×
“Most studies in our analysis did not assess fully automated systems [8, 29, 31–38, 40– 46], which still require manual Finally, this was the first meta-analysis to assess how long-term use of AID impacts patient-reported outcomes with a considerable number of studies.”
BackgroundMethodTrial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes
Wadwa, R. P., Reed, Z. W., Buckingham, B. A., DeBoer, M. D., Ekhlaspour, L., Forlenza, G. P., Schoelwer, M., Lum, J., Kollman, C., Beck, R. W., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2210834 · Cited by 191 · cited 1×
“…five (n = 636) assessed MiniMed 670G (Medtronic) [28, 34, 43, 44, 46]; five (n = 605) assessed t:slim X2 with Control IQ (Tandem) [33, 35, 36, 38, 45]; two (n = 144) assessed Modified Florence [30, 31]; two (n = 119) assessed MiniMed 780G (Medtronic) [8, 29]; two assessed openAPS (n = 129) [34,…”
Open-source automated insulin delivery in type 1 diabetes
Burnside, M. J., Lewis, D. M., Crocket, H. R., Meier, R. A., Williman, J. A., Sanders, O. J., Jefferies, C. A., Faherty, A. M., Paul, R. G., Lever, C. S., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2203913 · Cited by 183 · cited 2×
“…(Tandem) [33, 35, 36, 38, 45]; two (n = 144) assessed Modified Florence [30, 31]; two (n = 119) assessed MiniMed 780G (Medtronic) [8, 29]; two assessed openAPS (n = 129) [34, 41]; one (n = 63) assessed DBLG1 (Dbl-diabetes) [40]; and one (n = 219) assessed iLet Bionic Pancreas (Beta Bionics) [12].”
MethodMcAuley, S. A., Lee, M. H., Paldus, B., Vogrin, S., de Bock, M. I., Abraham, M. B., Bach, L. A., Burt, M. G., Cohen, N. D., Colman, P. G., et al. (2020) · Diabetes Care · doi:10.2337/dc20-1447 · Cited by 158 · cited 2×
“…were rated as “some concerns’’ due to missing outcome data [7] and deviations from the protocol (machine errors) [35, 40], and seven were rated as “high risk” due to lack of laboratory-measured HbA1c assessment [44, 46] or due to insufficient washout time [36, 38, 43, 47] in crossover studies.”
BackgroundMethodBoughton, C. K., Hartnell, S., Thabit, H., Mubita, W. M., Draxlbauer, K., Poettler, T., Wilinska, M. E., Hood, K. K., Mader, J. K., Narendran, P., et al. (2022) · The Lancet Healthy Longevity · doi:10.1016/s2666-7568(22)00005-8 · Cited by 127
McAuley, S. A., Trawley, S., Vogrin, S., Ward, G. M., Fourlanos, S., Grills, C. A., Lee, M. H., Alipoor, A. M., O’Neal, D. N., O’Regan, N. A., et al. (2022) · Diabetes Care · doi:10.2337/dc21-1667 · Cited by 117
Runge, A. S., Kennedy, L., Brown, A. S., Dove, A. E., Levine, B. J., Koontz, S. P., Iyengar, V. S., Odeh, S. A., Close, K. L., Hirsch, I. B., et al. (2018) · Clinical Diabetes · doi:10.2337/cd17-0094 · Cited by 87 · cited 1×
“Although HbA1c is currently the metric of choice by most endocrinology and diabetes societies [54, 55], TIR and HbA1c should be used as complementary parameters to guide care [56] and allow evaluation in clinical research [57].”
BackgroundThe Do-It-Yourself Artificial Pancreas: A Comprehensive Review
Kesavadev, J., Srinivasan, S., Saboo, B., Krishna B, M., & Krishnan, G. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00823-z · Cited by 85 · cited 1×
“Furthermore, there is a growing body of literature assessing the use of openAPS, or “do-it-yourself” (DIY) devices which are remotely controlled by open-source algorithms [61].”
BackgroundInvestigating the Use of a Hybrid Search Strategy for Systematic Reviews
Mourao, E., Kalinowski, M., Murta, L., Mendes, E., & Wohlin, C. (2017) · 2017 ACM/IEEE International Symposium on Empirical Software Engineering and Measurement (ESEM) · doi:10.1109/esem.2017.30 · Cited by 77 · cited 1×
“We also utilised a technique of backward snowballing, searching for additional eligible studies through a review of the references from prior publications [17].”
MethodJiao, X., Shen, Y., & Chen, Y. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002633 · Cited by 76 · cited 2×
“To our knowledge, only one published meta-analysis with 11 RCTs has discussed the potential of these devices up to 8 weeks of use [14].”
BackgroundResultPsychometric properties of the parent and child problem areas in diabetes measures
Evans, M. A., Weil, L. E. G., Shapiro, J. B., Anderson, L. M., Vesco, A. T., Rychlik, K., Hilliard, M. E., Antisdel, J., & Weissberg-Benchell, J. (2019) · Journal of Pediatric Psychology · doi:10.1093/jpepsy/jsz018 · Cited by 75
Matejko, B., Juza, A., Kieć-Wilk, B., Cyranka, K., Krzyżowska, S., Chen, X., Cohen, O., Da Silva, J., Malecki, M. T., & Klupa, T. (2022) · Diabetes Care · doi:10.2337/dc22-0470 · Cited by 72
Garg, S. K., Grunberger, G., Weinstock, R., Lawson, M. L., Hirsch, I. B., DiMeglio, L. A., Pop-Busui, R., Philis-Tsimikas, A., Kipnes, M., Liljenquist, D. R., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0421 · Cited by 63
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, B., Anderson, S. M., Raghinaru, D., Kudva, Y. C., Laffel, L. M., Levy, C., Pinsker, J. E., Wadwa, R. P., Buckingham, B., Doyle, F. J., et al. (2020) · Diabetes Care · doi:10.2337/dc19-1310 · Cited by 60 · cited 1×
“…(Tandem) [33, 35, 36, 38, 45]; two (n = 144) assessed Modified Florence [30, 31]; two (n = 119) assessed MiniMed 780G (Medtronic) [8, 29]; two assessed openAPS (n = 129) [34, 41]; one (n = 63) assessed DBLG1 (Dbl-diabetes) [40]; and one (n = 219) assessed iLet Bionic Pancreas (Beta Bionics) [12].”
Bionic Pancreas Research Group, Messer, L. H., Buckingham, B. A., Cogen, F., Daniels, M., Forlenza, G., Jafri, R. Z., Mauras, N., Muir, A., Wadwa, R. P., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0201.pub · Cited by 59
Pinsker, J. E., Dassau, E., Deshpande, S., Raghinaru, D., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Church, M. M., Desrochers, H., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0084 · Cited by 18 · cited 4×
“Most studies in our analysis did not assess fully automated systems [8, 29, 31–38, 40– 46], which still require manual Finally, this was the first meta-analysis to assess how long-term use of AID impacts patient-reported outcomes with a considerable number of studies.”
BackgroundMethodInfluential
Cited by
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Eichorst, B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s005 · Cited by 305
The role of automated insulin delivery technology in diabetes
Boughton, C. K., & Hovorka, R. (2024) · Diabetologia · doi:10.1007/s00125-024-06165-w · Cited by 57
Xu, C., Fan, S., Tian, Y., Liu, F., Furuya-Kanamori, L., Clark, J., Zhang, C., Li, S., Lin, L., Chu, H., et al. (2025) · BMJ · doi:10.1136/bmj-2024-082068 · Cited by 39
Shah, V. N., Peters, A. L., Umpierrez, G. E., Sherr, J. L., Akturk, H. K., Aleppo, G., Bally, L., Cengiz, E., Cinar, A., Dungan, K., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241291512 · Cited by 36
“60,61 As people with T1D become accustomed to the performance of current AID system, there will be a desire for further improvements including methods to further increase in % TIR, eliminate the need for manual entry of meals or to announce exercise, improved diagnosis of faults of the AID system,…”
Metadata
- Authors
- Godoi, A., Reis Marques, I., Padrão, E. M. H., Mahesh, A., Hespanhol, L. C., Riceto Loyola Júnior, J. E., de Souza, I. A. F., Moreira, V. C. S., Silva, C. H., Miyawaki, I. A., Oommen, C., Gomes, C., Silva, A. C., Advani, K., & de Sa, J. R.
- Venue
- Diabetology & Metabolic Syndrome
- Published
- 2023-09-28
- Volume
- 15
- Issue
- 1
- Pages
- 190-190
- ISSN
- 1758-5996 (ISSN-L)
- OpenAlex
- W4387078689
- Cited by
- 67
- References
- 36
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.