Degradation of poly-L-lactide. Part 1: in vitro and in vivo physiological temperature degradation
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Poly-L-lactide (PLLA) is one of the most significant members of a group of polymers regarded as bioresorbable. The degradation of PLLA proceeds through hydrolysis of the ester linkage in the polymer's backbone and is influenced by the polymer's initial molecular weight and degree of crystallinity. To evaluate its degradation PLLA pellets were processed by compression moulding into tensile test specimens and by extrusion into 2 mm diameter lengths of rod, prior to being sterilized by ethylene oxide gas (EtO) and degraded in both in vitro and in vivo environments. On retrieval at predetermined time intervals, procedures were used to evaluate the material's molecular weight, crystallinity, mechanical strength, and thermal properties. Additionally, the in vivo host tissue's biological response was analysed. The results from this study suggest that in both the in vitro and in vivo environments, degradation proceeded at the same rate and followed the general sequence of aliphatic polyester degradation, ruling out enzymes contributing and accelerating the degradation rate in vivo. Additionally, the absence of cells marking an inflammatory response suggests that the PLLA rods investigated in vivo were biocompatible throughout the 44 weeks duration of the study, before any mass loss was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765
Fischer, E. W., Sterzel, H. J., & Wegner, G. (1973) · Kolloid-Zeitschrift und Zeitschrift für Polymere · doi:10.1007/bf01498927 · Cited by 1,704
Why degradable polymers undergo surface erosion or bulk erosion
Burkersroda, F. V., Schedl, L., & Göpferich, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00170-9 · Cited by 1,146
Polylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Bioresorbability and biocompatibility of aliphatic polyesters
Vert, M., Li, S. M., Spenlehauer, G., & Guerin, P. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00701240 · Cited by 770
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Aliphatic polyesters. I. The degradation of poly(ϵ‐caprolactone) in vivo
Pitt, C. G., Chasalow, F. I., Hibionada, Y. M., Klimas, D. M., & Schindler, A. (1981) · Journal of Applied Polymer Science · doi:10.1002/app.1981.070261124 · Cited by 712
Research works printed but not linked: 9
- Li S., Degradable Polymers Principles & Applications, 43
- Chu C. C., The Biomedical Engineering Handbook, 611
- Barber F. A., 2002, Orthopedic Special Edn, 8, 29
- Chu C. C., Biomedical Applications of Synthetic Biodegradable Polymers, 103
- Anderson J. M., Biomedical Applications of Synthetic Biodegradable Polymers, 223
- Dickson G. R., Methods of Calcified Tissue Preparation, 79
- Boyde A., Methods of Calcified Tissue Preparation, 251
- 10.1016/0142-9612(90)90065-X · doi:10.1016/0142-9612(90)90065-x
- Timmins M. R., 1994, Trends in Polymer Science (TRIP), 2, 15
Cited by
Lifetime prediction of biodegradable polymers
Laycock, B., Nikolić, M., Colwell, J. M., Gauthier, E., Halley, P., Bottle, S., & George, G. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.02.004 · Cited by 662
Abiotic and biotic environmental degradation of the bioplastic polymer poly(lactic acid): A review
Karamanlioglu, M., Preziosi, R., & Robson, G. D. (2017) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2017.01.009 · Cited by 636
Photopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Karamanlioglu, M., & Robson, G. D. (2013) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2013.07.004 · Cited by 301
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Kempin, W., Franz, C., Koster, L.-C., Schneider, F., Bogdahn, M., Weitschies, W., & Seidlitz, A. (2017) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2017.02.014 · Cited by 180
Strategies and progress in synthetic textile fiber biodegradability
Egan, J., & Salmon, S. (2022) · SN Applied Sciences · doi:10.1007/s42452-021-04851-7 · Cited by 178
“Crystallinity of non-thermoplastic materials, like cellulosic fibers, is measured using X-ray diffraction [79], whereas changes in enthalpy of fusion (ΔHmelt), measured by Differential Scanning Calorimetry (DSC) relative to a standard with known crystallinity, is used to calculate crystallinity of thermoplastics, like…”
MethodGleadall, A., Pan, J., Kruft, M.-A., & Kellomäki, M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.039 · Cited by 165
“A large number of experiments have been conducted to understand the degradation of bioresorbable polymers such as polylactic acid (PLA), polyglycolic acid (PGA) and polycaprolactone (PCL) [1-31] which are used for various medical applications.”
BackgroundMethodInfluentialFelfel, R. M., Poocza, L., Gimeno-Fabra, M., Milde, T., Hildebrand, G., Ahmed, I., Scotchford, C., Sottile, V., Grant, D. M., & Liefeith, K. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/1/015011 · Cited by 106
Gleadall, A., Pan, J., & Atkinson, H. (2012) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2012.06.023 · Cited by 67
“Experimental data points [4,5] (discrete symbols) are plotted for three”
BackgroundMethodAccelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites
Felfel, R. M., Hossain, K. M. Z., Parsons, A. J., Rudd, C. D., & Ahmed, I. (2015) · Journal of Materials Science · doi:10.1007/s10853-015-8946-8 · Cited by 61
Chausse, V., Iglesias, C., Bou-Petit, E., Ginebra, M.-P., & Pegueroles, M. (2023) · Polymer Testing · doi:10.1016/j.polymertesting.2022.107817 · Cited by 39
Azhari, Z., McMahon, S., Pierucci, L., Wang, W., & Cameron, R. E. (2018) · Polymer International · doi:10.1002/pi.5563 · Cited by 13
Metadata
- Authors
- Weir, N. A., Buchanan, F. J., Orr, J. F., & Dickson, G. R.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2004-05-01
- Volume
- 218
- Issue
- 5
- Pages
- 307-319
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2117688233
- Cited by
- 182
- References
- 50
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.