Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To examine the test-retest reliability and validity of ten activity trackers for step counting at three different walking speeds. METHODS: Thirty-one healthy participants walked twice on a treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test-retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland-Altman plots. RESULTS: Test-retest reliability varied with ICC ranging from -0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland-Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results. CONCLUSION: Test-retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To correct for multiple testing, the significance level for the paired-sample t tests and Wilcoxon tests was adjusted by using the post hoc correction method of Bonferroni (12).”
MethodHASKELL, W. L., LEE, I.-M., PATE, R. R., POWELL, K. E., BLAIR, S. N., FRANKLIN, B. A., MACERA, C. A., HEATH, G. W., THOMPSON, P. D., & BAUMAN, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180616b27 · Cited by 4,616
Abellan Van Kan, G., Rolland, Y., Andrieu, S., Bauer, J., Beauchet, O., Bonnefoy, M., Cesari, M., Donini, L. M., Gillette-Guyonnet, S., Inzitari, M., et al. (2009) · The Journal of nutrition, health and aging · doi:10.1007/s12603-009-0246-z · Cited by 2,003 · cited 1×
“The latter could be an issue when self-tracking is used for the assessment of daily physical activity of patients with limited physical abilities or the elderly population (1,14).”
BackgroundSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“Many trackers demonstrate acceptable validity and reliability of step counting, however, other activity trackers perform relatively inadequately (4,13).”
BackgroundHow many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694 · cited 2×
“A systematic underestimation at slow walking speed has been described before in literature (2).”
BackgroundReliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Self-citationValidation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites
TUDOR-LOCKE, C., BARREIRA, T. V., & SCHUNA, J. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000476 · Cited by 218
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundHenriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“The top five vendors in 2015 [27] and 2016 [6], in sold units, were Fitbit, Xiaomi, Apple, Garmin, and Samsung.”
MethodInfluentialShin, G., Jarrahi, M. H., Fei, Y., Karami, A., Gafinowitz, N., Byun, A., & Lu, X. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103153 · Cited by 326
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
“We recognize that this is more lenient than some prior health sciences research on wearable HR accuracy [7] and pedometer step counting accuracy [40,41] that have defined an acceptable error rate to be ±5%.”
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001471 · Cited by 205
“(16) suggest a MAPE threshold of e5%, whereas Nelson et al.”
BackgroundReview of Wearable Device Technology and Its Applications to the Mining Industry
Mardonova, M., & Choi, Y. (2018) · Energies · doi:10.3390/en11030547 · Cited by 201
“Two major types of wearable cameras are used: small cameras that can be attached to either the body or clothes, or can even be worn in the ear, and larger cameras with mounting attachments to affix to caps or helmets [16].”
BackgroundCurrent State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194
“Misfit Family of Devices One investigation evaluated the Misfit Shine (1), and another the Misfit Flash (8).”
BackgroundMethodInfluentialBauer, M., Glenn, T., Geddes, J., Gitlin, M., Grof, P., Kessing, L. V., Monteith, S., Faurholt-Jepsen, M., Severus, E., & Whybrow, P. C. (2020) · International Journal of Bipolar Disorders · doi:10.1186/s40345-019-0164-x · Cited by 163
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001569 · Cited by 154
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140
“However, the accuracy might vary across brands [16,31] in terms of activity patterns or speed, exercise intensities [10,14,31], skin tone [10], room temperature [32], placement of sensors [29], or compression-induced and motion-induced artifacts [13,32-34].”
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116
Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0222569 · Cited by 53
Thijs, I., Fresiello, L., Oosterlinck, W., Sinnaeve, P., & Rega, F. (2019) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9865 · Cited by 44
“Studies showed that step count accuracy is dependent on gait patterns in healthy volunteers [18,19].”
Osborn, C. Y., van Ginkel, J. R., Marrero, D. G., Rodbard, D., Huddleston, B., & Dachis, J. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.8781 · Cited by 31
Nyenhuis, S. M., Balbim, G. M., Ma, J., Marquez, D. X., Wilbur, J., Sharp, L. K., & Kitsiou, S. (2020) · JMIR Formative Research · doi:10.2196/13900 · Cited by 18
Validity and Reliability Evaluation of Four Commercial Activity Trackers' Step Counting Performance
Tophøj, K. H., Petersen, M. G., Sæbye, C., Baad-Hansen, T., & Wagner, S. (2018) · Telemedicine and e-Health · doi:10.1089/tmj.2017.0264 · Cited by 18
Congruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T. (2018) · International Journal of Exercise Science · doi:10.70252/ubbt6886 · Cited by 16
“com 581 similar to the current study (2, 5, 10, 13, 18).”
BackgroundResultInfluential
Metadata
- Authors
- FOKKEMA, T., KOOIMAN, T. J. M., KRIJNEN, W. P., VAN DER SCHANS, C. P., & DE GROOT, M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2017-04
- Volume
- 49
- Issue
- 4
- Pages
- 793-800
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2548839520
- Cited by
- 212
- References
- 11
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.