Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Purpose: The purpose of this study was to determine the accuracy of 14-step counting methods under free-living conditions. Methods: Twelve adults (mean ± SD age, 35 ± 13 yr) wore a chest harness that held a GoPro camera pointed down at the feet during all waking hours for 1 d. The GoPro continuously recorded video of all steps taken throughout the day. Simultaneously, participants wore two StepWatch (SW) devices on each ankle (all programmed with different settings), one activPAL on each thigh, four devices at the waist (Fitbit Zip, Yamax Digi-Walker SW-200, New Lifestyles NL-2000, and ActiGraph GT9X (AG)), and two devices on the dominant and nondominant wrists (Fitbit Charge and AG). The GoPro videos were downloaded to a computer and researchers counted steps using a hand tally device, which served as the criterion method. Results: The SW devices recorded between 95.3% and 102.8% of actual steps taken throughout the day ( P > 0.05). Eleven step counting methods estimated less than 100% of actual steps; Fitbit Zip, Yamax Digi-Walker SW-200, and AG with the moving average vector magnitude algorithm on both wrists recorded 71% to 91% of steps ( P > 0.05), whereas the activPAL, New Lifestyles NL-2000, and AG (without low-frequency extension (no-LFE), moving average vector magnitude) worn on the hip, and Fitbit Charge recorded 69% to 84% of steps ( P < 0.05). Five methods estimated more than 100% of actual steps; AG (no-LFE) on both wrists recorded 109% to 122% of steps ( P > 0.05), whereas the AG (LFE) on both wrists and the hip recorded 128% to 220% of steps ( P < 0.05). Conclusions: Across all waking hours of 1 d, step counts differ between devices. The SW, regardless of settings, was the most accurate method of counting steps.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“step counting error routinely above 20% in both consumer and research-grade wrist-worn devices.”
From Development and Validation of a Machine Learning Wrist-worn Step Detection Algorithm with Deployment in the UK Biobank (2023) · cites this paper as [6]
Citations
Cites
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Self-citationPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Self-citationAccuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Self-citationStep Counting: A Review of Measurement Considerations and Health-Related Applications
Bassett, D. R., Toth, L. P., LaMunion, S. R., & Crouter, S. E. (2017) · Sports Medicine · doi:10.1007/s40279-016-0663-1 · Cited by 460
Self-citationA Meta-Analysis of Pedometer-Based Walking Interventions and Weight Loss
Richardson, C. R., Newton, T. L., Abraham, J. J., Sen, A., Jimbo, M., & Swartz, A. M. (2008) · The Annals of Family Medicine · doi:10.1370/afm.761 · Cited by 421
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Yamanouchi, K., Shinozaki, T., Chikada, K., Nishikawa, T., Ito, K., Shimizu, S., Ozawa, N., Suzuki, Y., Maeno, H., Kato, K., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.775 · Cited by 330
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[34,45,46,51,88,89,92,93,96,103,112,119,127,129, 131,141,149-161] Ankle/foot, pant pocket, shin, or waist/hip Current model 2012 Zip Fitbit”
Association of daily step count and step intensity with mortality among US adults
Saint-Maurice, P. F., Troiano, R. P., Bassett, D. R., Graubard, B. I., Carlson, S. A., Shiroma, E. J., Fulton, J. E., & Matthews, C. E. (2020) · JAMA · doi:10.1001/jama.2020.1382 · Cited by 660
Self-citationAssociation of Step Volume and Intensity With All-Cause Mortality in Older Women
Lee, I.-M., Shiroma, E. J., Kamada, M., Bassett, D. R., Matthews, C. E., & Buring, J. E. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.0899 · Cited by 604
Self-citationDaily steps and all-cause mortality: a meta-analysis of 15 international cohorts
Paluch, A. E., Bajpai, S., Bassett, D. R., Carnethon, M. R., Ekelund, U., Evenson, K. R., Galuska, D. A., Jefferis, B. J., Kraus, W. E., Lee, I.-M., et al. (2022) · The Lancet Public Health · doi:10.1016/s2468-2667(21)00302-9 · Cited by 582
Self-citationWindows into human health through wearables data analytics
Witt, D. R., Kellogg, R. A., Snyder, M. P., & Dunn, J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.01.001 · Cited by 157
Relationship of Daily Step Counts to All-Cause Mortality and Cardiovascular Events
Stens, N. A., Bakker, E. A., Mañas, A., Buffart, L. M., Ortega, F. B., Lee, D.-C., Thompson, P. D., Thijssen, D. H. J., & Eijsvogels, T. M. H. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.07.029 · Cited by 345
Doherty, C., Baldwin, M., Keogh, A., Caulfield, B., & Argent, R. (2024) · Sports Medicine · doi:10.1007/s40279-024-02077-2 · Cited by 133
“These include variability in the algorithms used by different devices to estimate metrics such as heart rate, sleep or physical activity [20]; user-specific factors such as age, body size or skin tone [21]; and differences in device placement and wear time [22].”
Johnston, W., Judice, P. B., Molina García, P., Mühlen, J. M., Lykke Skovgaard, E., Stang, J., Schumann, M., Cheng, S., Bloch, W., Brønd, J. C., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103147 · Cited by 128
Prospective Association of Daily Steps With Cardiovascular Disease: A Harmonized Meta-Analysis
Paluch, A. E., Bajpai, S., Ballin, M., Bassett, D. R., Buford, T. W., Carnethon, M. R., Chernofsky, A., Dooley, E. E., Ekelund, U., Evenson, K. R., et al. (2022) · Circulation · doi:10.1161/circulationaha.122.061288 · Cited by 131
Self-citationA Framework to Evaluate Devices That Assess Physical Behavior
Keadle, S. K., Lyden, K. A., Strath, S. J., STAUDENMAYER, J. W., & Freedson, P. S. (2019) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000206 · Cited by 124
Assessment of Physical Activity in Adults Using Wrist Accelerometers
Liu, F., Wanigatunga, A. A., & Schrack, J. A. (2021) · Epidemiologic Reviews · doi:10.1093/epirev/mxab004 · Cited by 126
Consumer Wearable Health and Fitness Technology in Cardiovascular Medicine
Petek, B. J., Al‐Alusi, M. A., Moulson, N., Grant, A. J., Besson, C., Guseh, J. S., Wasfy, M. M., Grémeaux, V., Churchill, T. W., & Baggish, A. L. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.054 · Cited by 129
Burchartz, A., Anedda, B., Auerswald, T., Giurgiu, M., Hill, H., Ketelhut, S., Kolb, S., Mall, C., Manz, K., Nigg, C. R., et al. (2020) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2020.101703 · Cited by 113
Wu, Y., Petterson, J. L., Bray, N. W., Kimmerly, D. S., & O'Brien, M. W. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.08.002 · Cited by 96
Jayedi, A., Gohari, A., & Shab‐Bidar, S. (2021) · Sports Medicine · doi:10.1007/s40279-021-01536-4 · Cited by 104
Sheng, M., Yang, J., Bao, M., Chen, T., Cai, R., Zhang, N., Chen, H., Liu, M., Wu, X., Zhang, B., et al. (2021) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2021.09.004 · Cited by 79
Ngueleu, A.-M., Barthod, C., Best, K. L., Routhier, F., Otis, M. J.-D., & Batcho, C. S. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01085-5 · Cited by 81
John, D., Morton, A. L., ARGUELLO, D. J., Lyden, K. A., & Bassett, D. R. (2018) · Sensors · doi:10.3390/s18041206 · Cited by 81
Self-citationKatz, N. P., Dworkin, R. H., North, R. B., Thomson, S., Eldabe, S. S., Hayek, S. M., Kopell, B. H., Markman, J. D., Rezai, A. R., Taylor, R. S., et al. (2021) · Pain · doi:10.1097/j.pain.0000000000002204 · Cited by 83
Comprehensive comparison of Apple Watch and Fitbit monitors in a free-living setting
Bai, Y., Tompkins, C. L., Gell, N., Dione, D. R., Zhang, T., & Byun, W. (2021) · PLoS ONE · doi:10.1371/journal.pone.0251975 · Cited by 78
Walking for health during pregnancy: A literature review and considerations for future research
Connolly, C. P., Conger, S. A., Montoye, A. H. K., Marshall, M. R., Schlaff, R. A., Badon, S. E., & Pivarnik, J. M. (2018) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2018.11.004 · Cited by 74
Mañas, A., del Pozo Cruz, B., Ekelund, U., Losa Reyna, J., Rodríguez Gómez, I., Carnicero Carreño, J. A., Rodríguez Mañas, L., García García, F. J., & Ara, I. (2022) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2021.05.004 · Cited by 54
Hansen, B. H., Dalene, K. E., Ekelund, U., Wang Fagerland, M., Kolle, E., Steene‐Johannessen, J., Tarp, J., & Alfred Anderssen, S. (2020) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13726 · Cited by 54
Moore, C. C., McCullough, A. K., Aguiar, E. J., Ducharme, S. W., & Tudor-Locke, C. E. (2020) · Journal of Physical Activity and Health · doi:10.1123/jpah.2019-0205 · Cited by 55
Mikkelsen, M.-L. K., Berg‐Beckhoff, G., Frederiksen, P., Horgan, G. W., O’Driscoll, R., Palmeira, A. L., Scott, S., Stubbs, R. J., Heitmann, B. L., & Larsen, S. C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234426 · Cited by 59
Ballin, M., Nordström, P., Niklasson, J., Alamäki, A., Condell, J., Tedesco, S., & Nordström, A. (2020) · BMC Public Health · doi:10.1186/s12889-020-09929-2 · Cited by 47
Giurgiu, M., Timm, I., Becker, M. L., Schmidt, S., Wunsch, K., Nissen, R., Davidovski, D., Bussmann, J. B. J., Nigg, C. R., Reichert, M., et al. (2022) · JMIR mhealth and uhealth · doi:10.2196/36377 · Cited by 55
Gardner, A. W., Montgomery, P. S., Wang, M., & Shen, B. (2022) · Vascular Medicine · doi:10.1177/1358863x211072913 · Cited by 48
Assessing Physical Activity After ACL Injury: Moving Beyond Return to Sport
Kuenze, C. M., Collins, K. A., Pfeiffer, K. A., & Lisee, C. M. (2021) · Sports Health A Multidisciplinary Approach · doi:10.1177/19417381211025307 · Cited by 44
Rowlands, A. V., Maylor, B. D., Dawkins, N. P., Dempsey, P. C., Edwardson, C. L., Soczawa-Stronczyk, A. A., Bocian, M., Patterson, M., & Yates, T. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2147134 · Cited by 39
Gorzelitz, J., Farber, C., Gangnon, R. E., & Cadmus‐Bertram, L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0072 · Cited by 41
Nakagata, T., Murakami, H., Kawakami, R., Tripette, J., Nakae, S., Yamada, Y., Ishikawa‐Takata, K., Tanaka, S., & Miyachi, M. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.08.004 · Cited by 34
Watanabe, D., Yoshida, T., Watanabe, Y., Yamada, Y., Miyachi, M., & Kimura, M. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003133 · Cited by 36
Giurgiu, M., von Haaren‐Mack, B., Fiedler, J., Woll, S., Burchartz, A., Kolb, S., Ketelhut, S., Kubica, C., Nigg, C., Timm, I., et al. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.101006 · Cited by 45
Hartung, V., Sarshar, M., Karle, V. L., Shammas, L., Rashid, A., Roullier, P., Eilers-Petri, C., Mäurer, M., Flachenecker, P., Pfeifer, K., et al. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17249314 · Cited by 36
Femiano, R., Werner, C., Wilhelm, M., & Eser, P. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.035 · Cited by 31
“Only few studies have validated step-counting algorithms in a daily living setting [18,27,28], which is time consuming and tedious as large video files have to be watched and analyzed.”
BackgroundHöchsmann, C., Knaier, R., Infanger, D., & Schmidt‐Trucksäss, A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab635f · Cited by 36
A Transparent Method for Step Detection Using an Acceleration Threshold
Ducharme, S. W., Lim, J., Busa, M. A., Aguiar, E. J., Moore, C. C., Schuna, J. M., Barreira, T. V., STAUDENMAYER, J. W., Chipkin, S. R., & Tudor-Locke, C. E. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2021-0011 · Cited by 33
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
Bezuidenhout, L., Thurston, C., Hagströmer, M., & Conradsson, D. M. (2021) · Sensors · doi:10.3390/s21093154 · Cited by 37
Small, S. R., Chan, S., Walmsley, R., von Fritsch, L., Acquah, A., Mertes, G., Feakins, B., Creagh, A. P., Strange, A., Matthews, C., et al. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003478 · Cited by 22
Cardiometabolic thresholds for peak 30-min cadence and steps/day
Adams, B. E., Fidler, K., Demoes, N., Aguiar, E. J., Ducharme, S. W., McCullough, A. K., Moore, C. C., Tudor-Locke, C. E., & Thomas, D. M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0219933 · Cited by 33
Klasnja, P., Rosenberg, D. E., Zhou, J., Anau, J., Gupta, A. S., & Arterburn, D. E. (2020) · Translational Behavioral Medicine · doi:10.1093/tbm/ibaa040 · Cited by 33
Viciana, J., Casado-Robles, C., Guijarro-Romero, S., & Mayorga-Vega, D. (2022) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2022.356 · Cited by 39
A Cluster-Randomized Trial on Small Incentives to Promote Physical Activity
Kramer, J.-N., Tinschert, P., Scholz, U., Fleisch, E., & Kowatsch, T. (2018) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2018.09.018 · Cited by 32
Accurate Step Count with Generalized and Personalized Deep Learning on Accelerometer Data
Luu, L., Pillai, A., Lea, H., Buendía, R., Khan, F. M., & Dennis, G. (2022) · Sensors · doi:10.3390/s22113989 · Cited by 28
Johnston, W., Keogh, A., Dickson, J., Leslie, S. J., Megyesi, P., Connolly, R., Burke, D., & Caulfield, B. (2022) · JMIR Formative Research · doi:10.2196/34257 · Cited by 31
Effects of Brief Intermittent Walking Bouts on Step Count Accuracy of Wearable Devices
Toth, L. P., Park, S., Pittman, W. L., Sarisaltik, D., Hibbing, P. R., Morton, A. L., Springer, C. M., Crouter, S. E., & Bassett, D. R. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0050 · Cited by 26
Self-citationMartindale, C. F., Šprager, S., & Eskofier, B. M. (2019) · Sensors · doi:10.3390/s19081820 · Cited by 28
Comparison of Wrist- and Hip-Worn Activity Monitors When Meeting Step Guidelines
Nelson, R. K., Hasanaj, K., Connolly, G., Millen, L. S., Muench, J. P., Bidolli, N. S. C., Preston, M. A., & Montoye, A. H. K. (2022) · Preventing Chronic Disease · doi:10.5888/pcd19.210343 · Cited by 26
Small, S. R., Chan, S., Walmsley, R., Fritsch, L. V., Acquah, A., Mertes, G., Feakins, B. G., Creagh, A., Strange, A., Matthews, C. E., et al. (2023) · doi:10.1101/2023.02.20.23285750 · Cited by 22
Keadle, S. K., Meuter, L., Phelan, S., & Phillips, S. M. (2021) · Journal of Behavioral Medicine · doi:10.1007/s10865-021-00218-w · Cited by 24
Toth, L. P., Paluch, A. E., Bassett, D. R., Rees‐Punia, E., EBERL, E. M., Park, S., & Evenson, K. R. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003282 · Cited by 22
Self-citationSuau, Q., Bianchini, E., Bellier, A., Chardon, M., Milane, T., Hansen, C., & Vuillerme, N. (2024) · Sensors · doi:10.3390/s24030825 · Cited by 26
Niela‐Vilén, H., Azimi, I., Suorsa, K., Sarhaddi, F., Stenholm, S., Liljeberg, P., Rahmani, A. M., & Axelin, A. (2022) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000885 · Cited by 27
Pregnancy walking cadence does not vary by trimester
Marshall, M. R., Montoye, A. H. K., & George, A. J. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.06.175 · Cited by 21
Park, S., Marcotte, R. T., STAUDENMAYER, J. W., Strath, S. J., Freedson, P. S., & Chasan‐Taber, L. (2022) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-022-05236-3 · Cited by 17
Self-citationWearable Activity Trackers in Clinical Research and Practice
Bassett, D. R., Freedson, P. S., & John, D. (2019) · Kinesiology Review · doi:10.1123/kr.2018-0060 · Cited by 19
Self-citationNakagata, T., Yamada, Y., Taniguchi, M., Nanri, H., Kimura, M., Miyachi, M., & Ono, R. (2024) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-024-00943-0 · Cited by 15
Goldstein, S. P., Thomas, J. G., Vithiananthan, S., Blackburn, G. L., Jones, D. B., Webster, J., Jones, R. N., Evans, E. W., Dushay, J. R., Moon, J., et al. (2018) · BMC Obesity · doi:10.1186/s40608-018-0204-6 · Cited by 14
Clevenger, K. A., Molesky, M. J., Vusich, J., & Montoye, A. H. K. (2019) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2019.1577737 · Cited by 13
“Future research should be conducted in a free-living setting with a criterion measure such as directly observed steps (Toth et al., 2018), with a previously validated monitor, like the Stepwatch”
MethodFuchita, M., Ridgeway, K. J., Kimzey, C., Melanson, E. L., & Fernandez-Bustamante, A. (2023) · Interactive Journal of Medical Research · doi:10.2196/46629 · Cited by 21
Free-Living Validation and Harmonization of 10 Wearable Step Count Monitors
Park, S., Marcotte, R. T., Toth, L. P., Paulus, P. F., Lauricella, L. P., Kim, A. H., Crouter, S. E., Springer, C. M., STAUDENMAYER, J. W., & Bassett, D. R. (2021) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000172 · Cited by 16
Self-citationEven a small dose of physical activity can be good medicine
Lee, I.-M. M., Powell, K. E., Sarmiento, O. L., & Hallal, P. C. (2025) · Nature Medicine · doi:10.1038/s41591-024-03396-7 · Cited by 18
Daily Step Counts in Participants With and Without Peripheral Artery Disease
Gardner, A. W., Montgomery, P. S., Wang, M., Shen, B., Casanegra, A. I., Silva-Palacios, F., Zhang, S., Pomilla, W. A., Esponda, O. L., & Kuroki, M. T. (2020) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000554 · Cited by 13
Kowahl, N., Shin, S., Barman, P., Rainaldi, E., Popham, S. F., & Kapur, R. (2023) · JMIR Human Factors · doi:10.2196/48270 · Cited by 12
Comparison of Activity Monitors Accuracy in Assessing Intermittent Outdoor Walking
Taoum, A., Chaudru, S., de Müllenheim, P., Congnard, F., Emily, M., Noury-Desvaux, B., Bickert, S., Carrault, G., Mahé, G., & Faucheur, A. L. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002587 · Cited by 15
Ballin, M., Antonsson, O., Rosenqvist, V., Nordström, P., & Nordström, A. (2021) · BMC Public Health · doi:10.1186/s12889-021-12401-4 · Cited by 17
Popham, S. F., Burq, M., Rainaldi, E., Shin, S., Dunn, J., & Kapur, R. (2023) · JMIR Biomedical Engineering · doi:10.2196/43726 · Cited by 10
Gardner, A. W., Montgomery, P. S., Wang, M., Shen, B., Afaq, A., & Khurana, A. (2022) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2021.12.071 · Cited by 11
Singh, R., Gehlot, A., Khilrani, J. K., & Mittal, M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815369-7.00001-x · Cited by 10
Gustafsson, M. E. A. K., Schiøttz‐Christensen, B., Wedderkopp, N., & Brønd, J. C. (2022) · Spine · doi:10.1097/brs.0000000000004385 · Cited by 11
Raw Photoplethysmography as an Enhancement for Research-Grade Wearable Activity Monitors
Hibbing, P. R., & Khan, M. M. (2024) · JMIR mhealth and uhealth · doi:10.2196/57158 · Cited by 10
Pan, J., & Wei, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-78684-w · Cited by 13
Playing With a Purpose: The Impact of Therapeutic Recreation During Hospitalization
Hoag, J. A., Bingen, K. M., Karst, J. S., Palou‐Torres, A., Yan, K., & Zhang, J. (2022) · Journal of Pediatric Hematology/Oncology Nursing · doi:10.1177/27527530211059437 · Cited by 11
Hyde, E. T., Nguyen, S., Tuz‐Zahra, F., Moore, C. C., Greenwood-Hickman, M. A., Walker, R. L., Natarajan, L., Rosenberg, D. E., & Bellettiere, J. (2022) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0001 · Cited by 9
Dominant vs. Non-Dominant Wrist Placement of Activity Monitors: Impact on Steps per Day
Park, S., Toth, L. P., Hibbing, P. R., Springer, C. M., Kaplan, A. S., Feyerabend, M. D., Crouter, S. E., & Bassett, D. R. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0060 · Cited by 10
Self-citationLynn, R., Pfitzer, R., Rogers, R. R., Ballmann, C. G., Williams, T. D., & Marshall, M. R. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0055 · Cited by 9
Núñez-Gaunaurd, A., & Tovin, M. M. (2024) · Journal of Developmental and Physical Disabilities · doi:10.1007/s10882-024-09951-x · Cited by 7
Daily Steps as a Public Health Metric for Physical Activity Monitoring and Promotion
Paluch, A. E., Matthews, C. E., Doherty, A., Ekelund, U., Evenson, K. R., Galuska, D. A., Jefferis, B. J. M. H., Kong, L., Kraus, W. E., Lee, I.-M. M., et al. (2025) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000375 · Cited by 11
Using Computer Vision to Annotate Video-Recoded Direct Observation of Physical Behavior
Keadle, S. K., Eglowski, S., Ylarregui, K., Strath, S. J., Martinez, J., Dekhtyar, A., & Kagan, V. (2024) · Sensors · doi:10.3390/s24072359 · Cited by 11
Keadle, S. K., Martinez, J., Strath, S. J., Sirard, J. R., John, D., Intille, S. S., ARGUELLO, D. J., Amalbert‐Birriel, M. A., Barnett, R., Thapa-Chhetry, B., et al. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0048 · Cited by 10
Mischler, B., Hilfiker, R., Hund‐Georgiadis, M., & Maguire, C. C. (2023) · Neurorehabilitation · doi:10.3233/nre-220248 · Cited by 6
Koffman, L. J., & Muschelli, J. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0008 · Cited by 8
Fan, J., Liu, Q., Dai, H., Zhou, D., Guo, Y., Xu, J., Wang, L., Hu, P., Jiang, J., Lin, X., et al. (2023) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.123.010066 · Cited by 7
Effect of Monitor Placement on the Daily Step Counts of Wrist and Hip Activity Monitors
Park, S., Toth, L. P., Crouter, S. E., Springer, C. M., Marcotte, R. T., & Bassett, D. R. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0065 · Cited by 6
Self-citationAccuracy of Physical Activity Monitors for Steps and Calorie Measurement During Pregnancy Walking
Montoye, A. H. K., Dahmen, J. B., Campbell, N., & Connolly, C. P. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0067 · Cited by 6
Chukwuemeka, U. M., Nnalue, A. D., Obiekwe, S. J., Maruf, F. A., Anakor, A. C., Moses, M. O., Amaechi, C., Okonkwo, U. P., & Amaechi, I. A. (2025) · BMC Digital Health · doi:10.1186/s44247-025-00159-3 · Cited by 6
Estimates of Physical Activity in Older Adults Using the ActiGraph Low-Frequency Extension Filter
Hicks, H. J., Laffer, A., Meyer, K., & Watts, A. S. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0034 · Cited by 5
Buchan, D. S. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0026 · Cited by 8
Methods for Step Count Data: Determining “Valid” Days and Quantifying Fragmentation of Walking Bouts
Reider, L. M., Bai, J., Scharfstein, D. O., & Zipunnikov, V. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.07.149 · Cited by 7
Gardner, A. W., Montgomery, P. S., Wang, M., Shen, B., Zhang, S., & Pomilla, W. A. (2022) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000686 · Cited by 5
Robertson, E. E., Naghavi, N., Wipperman, M. F., Tuckwell, K., Effendi, M. K., Alaj, R., Urbanek, J. K., Lederer, D. J., Fredenburgh, L. E., & Stuart, S. (2024) · Digital Health · doi:10.1177/20552076241277174 · Cited by 4
Validity of Smartwatches for Estimating Energy Expenditure During Aerobic Dance
Zhao, X., Ding, X., Yang, J., Yan, S., Wang, H., Tao, K., & Qiu, J. (2025) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-025-00339-7 · Cited by 6
Mehta, S., Allen, L. H., Bailey, R. L., Boushey, C. J., Duggan, C., Crouter, S. E., Engle‐Stone, R., Fahim, S. M., Gibbs, K., Hernández, E., et al. (2025) · Journal of Nutrition · doi:10.1016/j.tjnut.2025.10.030 · Cited by 9
Concurrent validity of Nokia Go activity tracker in walking and free‐living conditions
Lebleu, J., Detrembleur, C., Guebels, C., Hamblenne, P., & Valet, M. (2019) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13125 · Cited by 4
Mendoza, A., Lyden, K. A., Sirard, J. R., STAUDENMAYER, J. W., Tudor-Locke, C. E., & Freedson, P. S. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0035 · Cited by 5
Montoye, A. H. K., WESTGATE, B. S., Clevenger, K. A., PFEIFFER, K. A., VONDRASEK, J. D., FONLEY, M. R., BOCK, J. M., & Kaminsky, L. A. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002752 · Cited by 4
Connolly, C. P., Dahmen, J. B., Catena, R. D., Campbell, N., & Montoye, A. H. K. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0059 · Cited by 5
Gao, S., Zhou, X., Koffman, L. J., Wanigatunga, A. A., Schrack, J. A., Crainiceanu, C. M., & Muschelli, J. (2025) · The Journals of Gerontology Series A · doi:10.1093/gerona/glaf034 · Cited by 6
Metadata
- Authors
- TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R.
- Affiliations
- University of Tennessee at Knoxville (US)
- Maryville College (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-06
- Volume
- 50
- Issue
- 6
- Pages
- 1315-1322
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2792653514
- Cited by
- 154
- References
- 38
- Citations by year
- 2026: 17 · 2025: 13 · 2024: 20 · 2023: 14 · 2022: 25 · 2021: 21 · 2020: 19 · 2019: 15 · 2018: 10
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- University of North Florida Digital Commons (University of North Florida) (submittedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- step count accuracy, free-living conditions, accelerometry, ActiGraph GT9X, activPAL, Fitbit, wrist-worn devices, low-frequency extension, physical activity monitoring
- MeSH terms
- Fitness Trackers, Wearable Electronic Devices, Adult, Female, Humans, Male, Video Recording, Reproducibility of Results, Walking, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.