Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Purpose: The purpose of this study was to determine the accuracy of 14-step counting methods under free-living conditions. Methods: Twelve adults (mean ± SD age, 35 ± 13 yr) wore a chest harness that held a GoPro camera pointed down at the feet during all waking hours for 1 d. The GoPro continuously recorded video of all steps taken throughout the day. Simultaneously, participants wore two StepWatch (SW) devices on each ankle (all programmed with different settings), one activPAL on each thigh, four devices at the waist (Fitbit Zip, Yamax Digi-Walker SW-200, New Lifestyles NL-2000, and ActiGraph GT9X (AG)), and two devices on the dominant and nondominant wrists (Fitbit Charge and AG). The GoPro videos were downloaded to a computer and researchers counted steps using a hand tally device, which served as the criterion method. Results: The SW devices recorded between 95.3% and 102.8% of actual steps taken throughout the day ( P > 0.05). Eleven step counting methods estimated less than 100% of actual steps; Fitbit Zip, Yamax Digi-Walker SW-200, and AG with the moving average vector magnitude algorithm on both wrists recorded 71% to 91% of steps ( P > 0.05), whereas the activPAL, New Lifestyles NL-2000, and AG (without low-frequency extension (no-LFE), moving average vector magnitude) worn on the hip, and Fitbit Charge recorded 69% to 84% of steps ( P < 0.05). Five methods estimated more than 100% of actual steps; AG (no-LFE) on both wrists recorded 109% to 122% of steps ( P > 0.05), whereas the AG (LFE) on both wrists and the hip recorded 128% to 220% of steps ( P < 0.05). Conclusions: Across all waking hours of 1 d, step counts differ between devices. The SW, regardless of settings, was the most accurate method of counting steps.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“step counting error routinely above 20% in both consumer and research-grade wrist-worn devices.”
From Development and Validation of a Machine Learning Wrist-worn Step Detection Algorithm with Deployment in the UK Biobank (2023) · cites this paper as [6]
Citations
Cites
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Self-citationPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Self-citationAccuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Self-citationStep Counting: A Review of Measurement Considerations and Health-Related Applications
Bassett, D. R., Toth, L. P., LaMunion, S. R., & Crouter, S. E. (2017) · Sports Medicine · doi:10.1007/s40279-016-0663-1 · Cited by 460
Self-citationA Meta-Analysis of Pedometer-Based Walking Interventions and Weight Loss
Richardson, C. R., Newton, T. L., Abraham, J. J., Sen, A., Jimbo, M., & Swartz, A. M. (2008) · The Annals of Family Medicine · doi:10.1370/afm.761 · Cited by 421
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Yamanouchi, K., Shinozaki, T., Chikada, K., Nishikawa, T., Ito, K., Shimizu, S., Ozawa, N., Suzuki, Y., Maeno, H., Kato, K., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.775 · Cited by 330
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Taraldsen, K., Askim, T., Sletvold, O., Einarsen, E. K., Grüner Bjåstad, K., Indredavik, B., & Helbostad, J. L. (2011) · Physical Therapy · doi:10.2522/ptj.20100159 · Cited by 282
Increasing daily walking lowers blood pressure in postmenopausal women
MOREAU, K. L., DEGARMO, R., LANGLEY, J., MCMAHON, C., HOWLEY, E. T., BASSETT, D. R., & THOMPSON, D. L. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00005 · Cited by 280
Self-citationMotion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites
TUDOR-LOCKE, C., BARREIRA, T. V., & SCHUNA, J. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000476 · Cited by 218
IWANE, M., ARITA, M., TOMIMOTO, S., SATANI, O., MATSUMOTO, M., MIYASHITA, K., & NISHIO, I. (2000) · Hypertension Research · doi:10.1291/hypres.23.573 · Cited by 212
Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
FOKKEMA, T., KOOIMAN, T. J. M., KRIJNEN, W. P., VAN DER SCHANS, C. P., & DE GROOT, M. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001146 · Cited by 212
Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types
NELSON, M. B., KAMINSKY, L. A., DICKIN, D. C., & MONTOYE, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 205
Increasing daily walking improves glucose tolerance in overweight women
Swartz, A. M., Strath, S. J., Bassett, D. R., Moore, J. B., Redwine, B. A., Groër, M., & Thompson, D. L. (2003) · Preventive Medicine · doi:10.1016/s0091-7435(03)00144-0 · Cited by 192
Self-citationEvaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Self-citationEffects of a 10,000 Steps per Day Goal in Overweight Adults
Schneider, P. L., Bassett, D. R., Thompson, D. L., Pronk, N. P., & Bielak, K. M. (2006) · American Journal of Health Promotion · doi:10.4278/0890-1171-21.2.85 · Cited by 144
Self-citationComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Self-citationSandroff, B. M., Motl, R. W., Pilutti, L. A., Learmonth, Y. C., Ensari, I., Dlugonski, D., Klaren, R. E., Balantrapu, S., & Riskin, B. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093511 · Cited by 122
Accelerometer-Determined Steps/Day and Metabolic Syndrome
Sisson, S. B., Camhi, S. M., Church, T. S., Tudor-Locke, C., Johnson, W. D., & Katzmarzyk, P. T. (2010) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.02.015 · Cited by 116
Utility of a step activity monitor for the measurement of daily ambulatory activity in children
McDonald, C. M., Widman, L. M., Abresch, R. T., Walsh, S. A., & Walsh, D. D. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.10.011 · Cited by 111
Floegel, T. A., Florez-Pregonero, A., Hekler, E. B., & Buman, M. P. (2017) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glw098 · Cited by 109
Mudge, S., Stott, N. S., & Walt, S. E. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.039 · Cited by 105
Accuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90
Validity and Reliability of the Omron HJ-303 Tri-Axial Accelerometer-Based Pedometer
Steeves, J. A., Tyo, B. M., Connolly, C. P., Gregory, D. A., Stark, N. A., & Bassett, D. R. (2011) · Journal of Physical Activity and Health · doi:10.1123/jpah.8.7.1014 · Cited by 79
Self-citationEvaluation of the Omron HJ-720ITC Pedometer under Free-Living Conditions
SILCOTT, N. A., BASSETT, D. R., THOMPSON, D. L., FITZHUGH, E. C., & STEEVES, J. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318212888c · Cited by 78
Self-citationValidity of Activity Monitor Step Detection Is Related to Movement Patterns
Hickey, A., John, D., Sasaki, J. E., Mavilia, M., & Freedson, P. (2016) · Journal of Physical Activity and Health · doi:10.1123/jpah.2015-0203 · Cited by 71
Ng, L. W. C., JENKINS, S. C., & Hill, K. (2011) · Disability and Rehabilitation · doi:10.3109/09638288.2011.641666 · Cited by 64
Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
Self-citationAn Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations
Beevi, F. H. A., Miranda, J., Pedersen, C. F., & Wagner, S. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0120 · Cited by 62
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Self-citationDondzila, C. J., Swartz, A. M., Miller, N. E., Lenz, E. K., & Strath, S. J. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-143 · Cited by 34
Hornbuckle, L. M., Kingsley, J. D., Kushnick, M. R., Moffatt, R. J., Haymes, E. M., Miles, R., Toole, T., & Panton, L. B. (2016) · Clinical Medicine Insights Women s Health · doi:10.4137/cmwh.s39636 · Cited by 18
Step Count Filters in Wearable Step Counters
Toth, L. P., Park, S., Pittman, W. L., Sarasaltik, D., Morton, A. L., & Bassett, D. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000517885.68396.5b · Cited by 9
Self-citationSources of Error with Wearable Step Counters
Park, S., Toth, L. P., Morton, A. L., Pittman, W. L., Sarasaltik, D., & Bassett, D. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000517884.60773.a2 · Cited by 1
Self-citation
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[34,45,46,51,88,89,92,93,96,103,112,119,127,129, 131,141,149-161] Ankle/foot, pant pocket, shin, or waist/hip Current model 2012 Zip Fitbit”
Association of daily step count and step intensity with mortality among US adults
Saint-Maurice, P. F., Troiano, R. P., Bassett, D. R., Graubard, B. I., Carlson, S. A., Shiroma, E. J., Fulton, J. E., & Matthews, C. E. (2020) · JAMA · doi:10.1001/jama.2020.1382 · Cited by 660
Self-citationAssociation of Step Volume and Intensity With All-Cause Mortality in Older Women
Lee, I.-M., Shiroma, E. J., Kamada, M., Bassett, D. R., Matthews, C. E., & Buring, J. E. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.0899 · Cited by 604
Self-citationDaily steps and all-cause mortality: a meta-analysis of 15 international cohorts
Paluch, A. E., Bajpai, S., Bassett, D. R., Carnethon, M. R., Ekelund, U., Evenson, K. R., Galuska, D. A., Jefferis, B. J., Kraus, W. E., Lee, I.-M., et al. (2022) · The Lancet Public Health · doi:10.1016/s2468-2667(21)00302-9 · Cited by 582
Self-citationWindows into human health through wearables data analytics
Witt, D. R., Kellogg, R. A., Snyder, M. P., & Dunn, J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.01.001 · Cited by 157
Metadata
- Authors
- TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R.
- Affiliations
- University of Tennessee at Knoxville (US)
- Maryville College (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-06
- Volume
- 50
- Issue
- 6
- Pages
- 1315-1322
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2792653514
- Semantic Scholar
- f530681ed0004c1fbdf7e86eb9b0586668adc096
- Cited by
- 154
- References
- 38
- Citations by year
- 2026: 17 · 2025: 13 · 2024: 20 · 2023: 14 · 2022: 25 · 2021: 21 · 2020: 19 · 2019: 15 · 2018: 10
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- University of North Florida Digital Commons (University of North Florida) (submittedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- step count accuracy, free-living conditions, accelerometry, ActiGraph GT9X, activPAL, Fitbit, wrist-worn devices, low-frequency extension, physical activity monitoring
- MeSH terms
- Fitness Trackers, Wearable Electronic Devices, Adult, Female, Humans, Male, Video Recording, Reproducibility of Results, Walking, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.