Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 201–300 of 650
Solera-Sanchez, A., Adelantado‐Renau, M., Moliner‐Urdiales, D., & Beltran‐Valls, M. R. (2020) · Quality of Life Research · doi:10.1007/s11136-020-02699-9 · Cited by 31
Godoy-Cumillaf, A. E. R., Fuentes-Merino, P., Farías‐Valenzuela, C., Bastías, D. M. D., Giakoni-Ramírez, F., Bruneau-Chávez, J., & Merellano-Navarro, E. (2023) · Children · doi:10.3390/children10060981 · Cited by 34
“, Cambridgeshire, UK), which has been shown to provide valid measures of sedentary behavior, physical activity, and sleep [45,46].”
BackgroundLi, X., Kearney, P. M., Keane, E., Harrington, J. M., & Fitzgerald, T. (2017) · Journal of Epidemiology & Community Health · doi:10.1136/jech-2016-207691 · Cited by 30
Data Analytics in Physical Activity Studies With Accelerometers: Scoping Review
Liang, Y., Wang, C. I., & Hsiao, C. K. (2024) · Journal of Medical Internet Research · doi:10.2196/59497 · Cited by 37
Concurrent Validity of the MOX Activity Monitor Compared to the ActiGraph GT3X
van der Weegen, S., Essers, J. M. N. H., Spreeuwenberg, M. D., Verwey, R., Tange, H. J., de Witte, L., & Meijer, K. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2014.0097 · Cited by 30
“21 Also, in other studies the variance of the counts increased with speed, 22–24 and even the variance in volume of O 2 (in mL/kg/min) increased with speed.”
Kim, Y., Wijndaele, K., Sharp, S. J., Strain, T., Pearce, M., White, T., Wareham, N. J., & Brage, S. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0802-9 · Cited by 31
Watson, A., Maher, C. A., Tomkinson, G. R., Golley, R. K., Fraysse, F., Dumuid, D., Lewthwaite, H., & Olds, T. (2019) · BMC Public Health · doi:10.1186/s12889-019-7671-7 · Cited by 30
Minaeva, O., Riese, H., Lamers, F., Antypa, N., Wichers, M., & Booij, S. H. (2020) · Journal of Medical Internet Research · doi:10.2196/22634 · Cited by 29
“98) [39] and a good ability to determine sedentary behavior in adults (aged 18 to 55 years) (Pearson r=0.”
BackgroundMetabolic View on Human Healthspan: A Lipidome-Wide Association Study
Carrard, J., Gallart‐Ayala, H., Infanger, D., Teav, T., Wagner, J., Knaier, R., Colledge, F., Streese, L., Königstein, K., Hinrichs, T., et al. (2021) · Metabolites · doi:10.3390/metabo11050287 · Cited by 31
“99 Metabolic Equivalent of Task (METS) and vigorous ≥ 7 METS) [104].”
BackgroundInfluentialWrist-independent energy expenditure prediction models from raw accelerometer data
Montoye, A. H. K., Pivarnik, J. M., Mudd, L. M., Biswas, S. K., & Pfeiffer, K. A. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/10/1770 · Cited by 28
Adelantado‐Renau, M., Jiménez‐Pavón, D., Beltran‐Valls, M. R., & Moliner‐Urdiales, D. (2019) · Pediatric Research · doi:10.1038/s41390-019-0285-z · Cited by 34
Sandoz, V., Deforges, C., Stuijfzand, S., Epiney, M., Vial, Y., Sekarski, N., Messerli‐Bürgy, N., Ehlert, U., Graz, M. B., Harari, M. M., et al. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-032469 · Cited by 32
Adolescent circadian patterns link with psychiatric problems: A multimodal approach
Kuula, L., Halonen, R., Lipsanen, J. O., & Pesonen, A. (2022) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2022.03.056 · Cited by 29
Longitudinal determinants of 12-month changes on bone health in adolescent male athletes
Ubago‐Guisado, E., Vlachopoulos, D., Fatouros, I. G., Deli, C. K., Leontsini, D., Moreno, L. A., Courteix, D., & Gracia‐Marco, L. (2018) · Archives of Osteoporosis · doi:10.1007/s11657-018-0519-4 · Cited by 28
Baldwin, C. E., Rowlands, A. V., Fraysse, F., & Johnston, K. (2019) · Australian Critical Care · doi:10.1016/j.aucc.2019.10.006 · Cited by 29
Self-citationMarshall, Z. A., Mackintosh, K. A., Gregory, J. W., & McNarry, M. A. (2021) · Pediatric Diabetes · doi:10.1111/pedi.13288 · Cited by 32
“The GENEActiv has been validated and reported to provide reliable representations of physical activity behaviors in children.(37,38) Accelerometer data were downloaded from each device utilizing the GENEActiv PC software v2.”
MethodWatson, A., Dumuid, D., Maher, C. A., Fraysse, F., Mauch, C. E., Tomkinson, G. R., Ferguson, T., & Olds, T. (2022) · Childhood Obesity · doi:10.1089/chi.2022.0054 · Cited by 26
“When compared to other accelerometers, the GENEActiv has excellent convergent validity ( r = 0.98), 32 and has good test-retest reliability (intraclass correlation coefficient [ICC] = 0.67–0.87).”
InfluentialOrtega‐Gómez, S., Adelantado‐Renau, M., Carbonell‐Baeza, A., Moliner‐Urdiales, D., & Jiménez‐Pavón, D. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14431 · Cited by 29
Dirks, M. L., Stephens, F. B., Jackman, S. R., Gordo, J. G., Machin, D. J., Pulsford, R. M., van Loon, L. J. C., & Wall, B. T. (2018) · Experimental Physiology · doi:10.1113/ep086961 · Cited by 31
“using previously validated cut points (Esliger et al., 2011).”
Gómez‐Bruton, A., González‐Agüero, A., Casajús, J. A., & Vicente‐Rodríguez, G. (2014) · PubMed · doi:10.3305/nh.2014.30.2.7603 · Cited by 33
“487 update 531), via USB-to-PC connection, 47 GENEA accelerometers were initialized to collect unfiltered, triaxial acceleration data at a sampling rate of 80 Hz.(19)”
BackgroundMethodInfluentialVergara-Diaz, G. P., Daneault, J., Parisi, F., Admati, C., Alfonso, C., Bertoli, M., Bonizzoni, E., Carvalho, G. F., Costante, G., Fabara, E. E., et al. (2021) · Scientific Data · doi:10.1038/s41597-021-00831-z · Cited by 26
Yano, S., Koohsari, M. J., Shibata, A., Ishii, K., Frehlich, L., McCormack, G. R., & Oka, K. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16091597 · Cited by 26
“However, previous studies using an accelerometer in a mechanical shaker demonstrated that accelerometer output provided a valid prediction of physical activity intensity [29].”
ResultMaier, R. H., Kasim, A., Zacharias, J., Vale, L. D., Graham, R., Walker, A., Łaskawski, G., Deshpande, R., Goodwin, A. T., Kendall, S. W. H., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047676 · Cited by 26
Dumuid, D., Mellow, M. L., Olds, T., Tregoweth, E., Greaves, D., Keage, H. A. D., & Smith, A. E. (2022) · Journal of Alzheimer s Disease · doi:10.3233/jad-220181 · Cited by 26
“…Waking day behaviors were classified as time in moderate-vigorous intensity physical activity (MVPA;>806 gravitational units per min, g-min), light intensity physical activity (LPA; 378–806, g-min) or sedentary behavior (<377 g-min, excluding sleep time) using previously published cut points [18].”
Children's activity and diet behaviours in the summer holidays versus school year
Watson, A., Maher, C. A., Golley, R. K., Dumuid, D., Manson, A., Tomkinson, G. R., Fraysse, F., & Olds, T. (2023) · Pediatric Obesity · doi:10.1111/ijpo.13029 · Cited by 25
“98).(23) Specific types of activity were self-reported by children using the Multimedia Activity Recall for Children and Adolescents (MARCA).”
MethodWhite, J. W., Finnegan, O., Tindall, N., Nelakuditi, S., Brown, D. E., Pate, R. R., Welk, G. J., de Zambotti, M., Ghosal, R., Wang, Y., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0286898 · Cited by 30
Duncan, M. J., Roscoe, C. M. P., Faghy, M. A., Tallis, J. A., & Eyre, E. L. J. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00242 · Cited by 29
“9), the raw 80 Hz signal from all three axes were summarized into a single vector magnitude (gravity subtracted) (SVM gs), congruent with prior work by other authors (Esliger et al., 2011; Phillips et al., 2014; Roscoe et al., 2017).”
MethodResultInfluentialBeltran‐Valls, M. R., Adelantado‐Renau, M., & Moliner‐Urdiales, D. (2020) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2020.04.012 · Cited by 26
Landon‐Cardinal, O., Bachasson, D., Guillaume-Jugnot, P., Vautier, M., Champtiaux, N., Hervier, B., Rigolet, A., Aggarwal, R., Benvéniste, O., Hogrel, J., et al. (2020) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2020.06.014 · Cited by 27
Kwan, R. Y. C., Liu, J. Y. W., Lee, D., Tse, A. C. Y., & Lee, P. H. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.09.022 · Cited by 26
Schwendinger, F., Wagner, J., Infanger, D., Schmidt‐Trucksäss, A., & Knaier, R. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01350-6 · Cited by 25
“Firstly, cut-off values are used to enable the classification of performed activities into light, moderate, or vigorous intensity of PA (LPA, MPA, VPA) and are usually linked to more coherent units such as metabolic equivalents (METs) [11].”
MethodPerceived green space quality, child biomarkers and health-related outcomes: A longitudinal study
Putra, I. G. N. E., Astell‐Burt, T., & Feng, X. (2022) · Environmental Pollution · doi:10.1016/j.envpol.2022.119075 · Cited by 27
Transforming Big Data into AI‐ready data for nutrition and obesity research
Thomas, D. M., Knight, R. D., Gilbert, J. A., Cornelis, M. C., Gantz, M. G., Burdekin, K., Cummiskey, K., Sumner, S., Pathmasiri, W., Sazonov, E. E., et al. (2024) · Obesity · doi:10.1002/oby.23989 · Cited by 27
“Specifically, thresholds need to be set to distinguish non-wear time from sleep [85, 86], and similar thresholds need to be defined to classify each epoch as time spent within a distinct physical activity intensity category (e.g., sedentary, light, moderate, and vigorous-intensity physical…”
BackgroundInterventions outside the workplace for reducing sedentary behaviour in adults under 60 years of age
Murtagh, E., MURPHY, M. H., Milton, K. E., Roberts, N. W., O’Gorman, C. S., & Foster, C. E. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012554.pub2 · Cited by 28
“Ellingson 2016 employed the sojourn method (Lyden 2014) and Williams used the thresholds developed by Esliger 2011.”
BackgroundMethodPromoting physical activity in rural Australian adults using an online intervention
Mitchell, B. L., Smith, A. E., Rowlands, A. V., Fraysse, F., Parfitt, G., Lewis, N., & Dollman, J. (2018) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2018.07.002 · Cited by 24
Self-citationDomingo, C. H., Hernando, C., Collado‐Boira, E., Panizo, N., Martínez‐Navarro, I., & Hernando, B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202815 · Cited by 28
Klompstra, L. V., Kyriakou, M., Lambrinou, E., Piepoli, M. F., Coats, A. J. S., Solal, A. C., Cornelis, J., Gellen, B., Marqués‐Sulé, E., Niederseer, D., et al. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.2035 · Cited by 26
Bonn, S. E., Bergman, P., Lagerros, Y. T., Sjölander, A., & Bälter, K. A. (2015) · JMIR Research Protocols · doi:10.2196/resprot.3896 · Cited by 25
“Each SVM gs value was further multiplied with 2 in order to make our SVM gs values comparable to those reported by Esliger et al. [11], who used sampling frequency K =2 × 40 = 80 ( K is the number of samples per second).”
InfluentialBenadjaoud, M. A., Menai, M., van Hees, V. T., Zipunnikov, V., Régnaux, J.-P., Kivimäki, M., Singh‐Manoux, A., & Sabia, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-46771-y · Cited by 24
Duncan, M. J., Wilson, S., Tallis, J. A., & Eyre, E. L. J. (2016) · European Journal of Pediatrics · doi:10.1007/s00431-016-2795-6 · Cited by 25
“The GENEActiv has been shown to be reliable and valid measure of PA in adults [1] and children [3].”
BackgroundMethodInfluentialBuchan, D. S., Boddy, L. M., & McLellan, G. (2020) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1801441 · Cited by 24
Díaz, C., Galy, O., Caillaud, C., & Yacef, K. (2020) · IEEE Access · doi:10.1109/access.2020.3044295 · Cited by 24
“acceleration data frame into gravity-subtracted Signal Vector Magnitudes (SVMgs) [40] quantities within a 1 second epoch (see Formula 1).”
BackgroundLi, X., & Zhao, H. (2020) · PLoS Genetics · doi:10.1371/journal.pgen.1009089 · Cited by 27
“to provide equivalent output to the GENEActiv accelerometer, which has been validated against free-living energy expenditure assessment methods.(75-77) This study was covered by the general ethical approval for UK Biobank studies from the National Research Ethics Service by National Health Service on 17th June 2011 (R…”
Lapointe, J., Comtois, A. S., Romain, A. J., & Bernard, P. (2023) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2023.102430 · Cited by 21
Knuth, A. G., Assunção, M. C. F., Gonçalves, H., Menezes, A. M. B., Santos, I. S., Barros, A. J. D., Matijasevich, A., Ramires, V. V., Crochemore‐Silva, I., & Hallal, P. C. (2013) · Cadernos de Saúde Pública · doi:10.1590/s0102-311x2013000300013 · Cited by 26
Wang, Q., Lohit, S., Toledo, M. J. L., Buman, M. P., & Turaga, P. K. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591270 · Cited by 26
“88) was close to the one reported in [5] (0.”
BackgroundMethodResultInfluentialClemes, S. A., Varela-Mato, V., Munir, F., Edwardson, C. L., Chen, Y., Hamer, M., Gray, L. J., Jaicim, N. B., Richardson, G. A., Johnson, V., et al. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-030175 · Cited by 22
Almuklass, A. M., Davis, L. A., Hamilton, L. D., Hebert, J. R., Álvarez, E., & Enoka, R. M. (2018) · Neurorehabilitation and neural repair · doi:10.1177/1545968317753681 · Cited by 22
“21 MSWS-12 43 ± 11 (17-57) 35 ± 13 (12-55) 38 ± 13 (16-55) .”
Daily activities are associated with non-invasive measures of neuroplasticity in older adults
Smith, A. E., Dumuid, D., Goldsworthy, M. R., Graetz, L. J., Hodyl, N. A., Thornton, N. L. R., & Ridding, M. C. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.01.016 · Cited by 25
Cao, Z., Min, J., Hou, Y., Si, K., Wang, M., & Xu, C. (2024) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwae248 · Cited by 26
Tomkins‐Lane, C., & Haig, A. J. (2012) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-2012-0325 · Cited by 22
“A large body of literature supports the validity and reliability of accelerometers for measurement of physical activity in adults [7–14,17,17,20–66], children [67– 72], and older adults [18,73–76].”
Stability of the K4b2portable metabolic analyser during rest, walking and running
Howe, C. C. F., Matzko, R. O., Piaser, F., Pitsiladis, Y. P., & Easton, C. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.812231 · Cited by 22
“Despite this, the K4b(2) is often employed as the criterion method for the validation of energy expenditure predictions derived from accelerometers and other such devices with exercise protocols lasting up to and in excess of 1 h (e.g. Crouter, Churilla, & Bassett, 2006; Crouter, Kuffel, Frongillo, & Basset Jr, 2010;…”
MethodWireless system for monitoring and real-time classification of functional activity
Butala, P. M., Zhang, Y., Little, T. D. C., & WAGENAAR, R. C. (2012) · International Conference on Communication Systems & Networks (COMSNETS) · doi:10.1109/comsnets.2012.6151378 · Cited by 25
Objectively measured 24-hour activity profiles before and after total hip arthroplasty
Thewlis, D., Bahl, J. S., Fraysse, F., Curness, K., Arnold, J. B., Taylor, M., Callary, S. A., & Solomon, L. B. (2019) · The Bone & Joint Journal · doi:10.1302/0301-620x.101b4.bjj-2018-1240.r1 · Cited by 21
Psychosocial factors affecting sleep misperception in middle-aged community-dwelling adults
Park, S., Park, K., Shim, J., Youm, Y., Kim, J., Lee, E. M., & Kim, H. C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0241237 · Cited by 22
“Signal vector magnitude measurement was used to indicate behavioral changes [38].”
MethodChow, C. H., Fraysse, F., & Hillier, S. (2021) · Topics in Stroke Rehabilitation · doi:10.1080/10749357.2021.2006982 · Cited by 21
“It has also been validated to classify the intensity of PA in adults compared with ActiGraph accelerometer.(21) The GENEActiv has previously been used to monitor PA and sleep in stroke populations.”
MethodDiaz, K. M., Krupka, D. J., Chang, M. J., Kronish, I. M., Moise, N., Goldsmith, J., & Schwartz, J. E. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1293279 · Cited by 23
“Similar to other calibration studies (Esliger et al., 2011; Evenson et al., 2008; Pulsford et al., 2011; Schaefer et al., 2014; Sirard, Trost, Pfeiffer, Dowda, & Pate, 2005), the 1031 and 3589 cut-points for moderate and vigorous activity were selected based on the accelerometer counts that…”
ResultLAMA2 -Related Muscular Dystrophy Across the Life Span: A Cross-sectional Study
Bouman, K., Groothuis, J. T., Doorduin, J., van Alfen, N., ten Cate, F. E. A. U., van den Heuvel, F. M. A., Nijveldt, R., Kamsteeg, E., Dittrich, A. T. M., Draaisma, J. M. T., et al. (2023) · Neurology Genetics · doi:10.1212/nxg.0000000000200089 · Cited by 23
Schwendinger, F., Wagner, J., Knaier, R., Infanger, D., Rowlands, A. V., Hinrichs, T., & Schmidt‐Trucksäss, A. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003299 · Cited by 22
Self-citationRegular Practice of Competitive Sports Does Not Impair Sleep in Adolescents: DADOS Study
Beltran‐Valls, M. R., Artero, E. G., Seder, A. C., Legaz‐Arrese, A., Adelantado‐Renau, M., & Moliner‐Urdiales, D. (2017) · Pediatric Exercise Science · doi:10.1123/pes.2017-0129 · Cited by 21
Lim, R., Bereznicki, L., Corlis, M. E., Ellett, L. M. K., Kang, A. C., Merlin, T., Parfitt, G., Pratt, N. L., Rowett, D. S., Torode, S., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-032851 · Cited by 22
Jimenez‐Moreno, C., Charman, S. J., Nikolenko, N., Larweh, M., Turner, C., Gorman, G. S., Lochmüller, H., & Catt, M. (2018) · Disability and Rehabilitation · doi:10.1080/09638288.2018.1482376 · Cited by 23
“Wrist-worn GENEActiv data have demonstrated strong validity against indirect calorimetry for both physical activity and sedentary behaviour [26,27].”
BackgroundSelf-citationLock, M., Post, D., Dollman, J., & Parfitt, G. (2018) · Frontiers in Public Health · doi:10.3389/fpubh.2018.00341 · Cited by 20
“Accelerometer data will be processed using the cutpoints outlined by Esliger, Rowlands (100) to determine total minutes of sedentary, light, moderate and vigorous activity for each 7 day period of continuous accelerometry.”
BackgroundMethodInfluentialTarca, B. D., Wycherley, T. P., Bennett, P. N., Meade, A., & Ferrar, K. (2020) · Journal of Physical Activity and Health · doi:10.1123/jpah.2019-0338 · Cited by 24
Christian, D. L., Todd, C., Rance, J. Y., Stratton, G., Mackintosh, K. A., Rapport, F., & Brophy, S. T. (2020) · PLoS ONE · doi:10.1371/journal.pone.0230745 · Cited by 21
Glaus, J., Kang, S. J., Guo, W., Lamers, F., Strippoli, M. F., Leroux, A., Dey, D., Plessen, K. J., Vaucher, J., Vollenweider, P., et al. (2023) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2023.05.042 · Cited by 22
Buendía, R., Karpefors, M., Folkvaljon, F., HUNTER, R., Sillén, H., LUU, L., Docherty, K. F., & Cowie, M. (2024) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2024.01.016 · Cited by 19
Mitchell, B. L., Lewis, N., Smith, A. E., Rowlands, A. V., Parfitt, G., & Dollman, J. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-969 · Cited by 21
“ger and colleagues [43] from 60-second epochs using a custom-made algorithm in Microsoft Excel.”
MethodSelf-citationDairo, Y. M., Collett, J., & Dawes, H. (2017) · British Journal of Learning Disabilities · doi:10.1111/bld.12188 · Cited by 19
“…the same software, but the GENEActiv data were converted by means of an in- house custom written program into how much time a participant spends in sedentary, light, moderate- or vigorous- intensity physical activity (MVPA) using PA cut points based on the Eslinger’s study (Esliger et al., 2011).”
MethodInnerd, P., Harrison, R., & Coulson, M. (2018) · BMC Public Health · doi:10.1186/s12889-018-5215-1 · Cited by 23
“(≤100 Hz), raw acceleration data compatible with opensource, freely available analytical methods which estimate physical activity intensity [12], physical activity type [13] and sedentary behaviour [14].”
BackgroundShedding light on light exposure in elderly with intellectual disabilities
Böhmer, M. N., Valstar, M. J., Aarts, M. M., Bindels, P., Oppewal, A., Someren, E. J. W. V., & Festen, D. A. M. (2021) · Journal of Intellectual Disability Research · doi:10.1111/jir.12822 · Cited by 19
Bouman, K., Groothuis, J. T., Doorduin, J., van Alfen, N., ten Cate, F. E. A. U., van den Heuvel, F. M. A., Nijveldt, R., van Tilburg, W. C. M., Buckens, S. C. F. M., Dittrich, A. T. M., et al. (2021) · BMC Neurology · doi:10.1186/s12883-021-02336-z · Cited by 22
Williams, J., Stubbs, B., Gaughran, F., & Craig, T. (2016) · Trials · doi:10.1186/s13063-016-1660-2 · Cited by 20
“99 METs) and vigorous (>7+ METs), based on standardised algorithms with high sensitivity and specificity with oxygen consumption [23].”
BackgroundHuerta‐Uribe, N., Chueca-Guindulain, M. J., Berrade‐Zubiri, S., Sánchez, E. B., Izquierdo, M., & García‐Hermoso, A. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14369 · Cited by 18
Rovero, M., Preisig, M., Marques-Vidal, P. M., Strippoli, M. F., Vollenweider, P., Vaucher, J., Berney, A., Merikangas, K. R., Vandeleur, C. L., & Glaus, J. (2023) · Comprehensive Psychiatry · doi:10.1016/j.comppsych.2023.152442 · Cited by 20
Guu, T., Brem, A., Albertyn, C. P., Kandangwa, P., Aarsland, D., & Ffytche, D. H. (2024) · Alzheimer s & Dementia · doi:10.1002/alz.13772 · Cited by 19
“TheRmarkdownpackagedevelopedbyActivinsight 21 wasusedtogen-erate a daily personal activity report to visually inspect specific shift periods of non-wear (i.e., whether the non-wear fell within day shift 06:01-14:00, evening shift 14:01-22:00, or night shift 22:01-06:00).”
BackgroundPerceived somatic and affective barriers for self-efficacy and physical activity
Warner, L. M., Wolff, J. K., Spuling, S. M., & Wurm, S. (2017) · Journal of Health Psychology · doi:10.1177/1359105317705979 · Cited by 18
“Therefore, activity levels from seven consecutive days (days 3–9) were transformed into moderate and vigorous minutes of physical activity per week according to validated thresholds for older adults published by Esliger et al. (2011), and summed up.”
BackgroundMethodJackman, S. R., Brook, M. S., Pulsford, R. M., Cockcroft, E., Campbell, M. I., Rankin, D., Atherton, P. J., Smith, K., & Bowtell, J. L. (2018) · Experimental Gerontology · doi:10.1016/j.exger.2018.06.007 · Cited by 20
“Data were then averaged over 60s-epochs and previously validated acceleration cutpoints were then applied to identify sedentary time and time spent performing light, moderate and vigorous physical activity over the one week period (Esliger et al., 2011).”
Celis-Morales, C. A., Lyall, D. M., Petermann-Rocha, F. E., Anderson, J. J., Ward, J., Iliodromiti, S., Mackay, D., Welsh, P. I., Bailey, M. E. S., Pell, J. P., et al. (2019) · International Journal of Obesity · doi:10.1038/s41366-019-0381-5 · Cited by 21
McDevitt, B., Moore, L. D., Akhtar, N., Connolly, J., Doherty, R., & Scott, W. (2021) · Sensors · doi:10.3390/s21062034 · Cited by 21
“[48] reported that a waist-worn GENEA triaxial accelerometer produced an almost identical correlation with energy expenditure as the same model worn on the wrist.”
BackgroundMethodPancardo, P., Hernández-Nolasco, J. A., & Acosta, F. (2018) · Mobile Information Systems · doi:10.1155/2018/4216172 · Cited by 20
“Many other solutions are focused on predefined activities such as walking and running without considering physiological parameters of each person, giving results that are not clearly differentiated [9, 11].”
BackgroundStrutz, E. M., Browning, R. C., Smith, S., Lohse, B., & Cunningham-Sabo, L. D. (2018) · Journal of Physical Activity and Health · doi:10.1123/jpah.2016-0645 · Cited by 19
“16,17 Body-worn accelerometers (ACCs) provide an objective measurement of the frequency, intensity, and duration of PA. 17 The GENEActiv ACC (Activinsights Ltd, Cambridge, UK) is one such device that collects raw (ie, not processed) acceleration data and allows for a user-determined sampling…”
BackgroundMethodDuncan, M. J., Brown, W. J., Burrows, T. L., Collins, C. E., Fenton, S., Glozier, N., Kolt, G. S., Morgan, P. J., Hensley, M., Holliday, E. G., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-026179 · Cited by 19
“Physical activity outcomes will include daily minutes of sedentary, light, moderate and vigorous intensity physical activity during waking hours estimated using established cut points.(47) 48 Self-report measures of physical activity, sitting and sleep will also be collected.”
MethodTarca, B. D., Jesudason, S., Wycherley, T. P., Leu, R. K. L., Ovenden, M., Meade, A., Bennett, P. N., Boyle, T., & Ferrar, K. (2023) · Kidney International Reports · doi:10.1016/j.ekir.2023.12.024 · Cited by 17
Prechtl, L. M., Carrard, J., Gallart‐Ayala, H., Borreggine, R., Teav, T., Königstein, K., Wagner, J., Knaier, R., Infanger, D., Streese, L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-76835-7 · Cited by 17
“Data analysis was conducted using the validated open-source Excel macro file "General physical activity" (version 2), with total and moderate-to-vigorous physical activity quantified in minutes per day (moderate defined as 4.00–6.99 Metabolic Equivalent of Task (METS) and vigorous as ≥ 7 METS) 17 .”
MethodInfluentialMethodological Choices on 24-h Movement Behavior Assessment by Accelerometry: A Scoping Review
Rodrigues, B., Videira‐Silva, A., Lopes, L., Sousa‐Sá, E., Vale, S. M. C. G., Cliff, D. P., Mendes, R., & Santos, R. (2025) · Sports Medicine - Open · doi:10.1186/s40798-025-00820-1 · Cited by 20
Huberty, J., Matthews, J., Leiferman, J. A., Cacciatore, J., & Gold, K. J. (2017) · Pilot and Feasibility Studies · doi:10.1186/s40814-017-0162-7 · Cited by 19
“standing), and moderate to vigorous physical activity [83, 84].”
BackgroundWrist-worn Accelerometry for Runners: Objective Quantification of Training Load
Stiles, V. H., PEARCE, M., Moore, I. S., Langford, J., & Rowlands, A. V. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001704 · Cited by 20
Self-citationVerhoog, S., Gubelmann, C., Guessous, I., Bano, A., Franco, O. H., & Marques-Vidal, P. M. (2019) · Maturitas · doi:10.1016/j.maturitas.2019.08.004 · Cited by 17
Guo, G., Zhang, H., Yao, L., Li, H., Xu, C., Li, Z., & Xu, W. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3494970 · Cited by 21
“For the sedentary-light threshold (62.8 mg), sensitivity and specificity are 98% and 96%; for the light-moderate threshold (112.9 mg), sensitivity and specificity are 98% and 64%; for the moderate-vigorous threshold, sensitivity and specificity are 78% and 98% [42].”
BackgroundMethodInfluentialCoe, S., Axelsson, E., Murphy, V., dos Santos, M. B., Collett, J., Clegg, M., Izadi, H., Harrison, J. M., Buckingham, E., & Dawes, H. (2017) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2017.07.002 · Cited by 19
Schrire, Z. M., Phillips, C. L., Duffy, S. L., Marshall, N. S., Mowszowski, L., LaMonica, H. M., Stranks, L., Gordon, C. J., Chapman, J. L., Saini, B., et al. (2024) · Journal of Pineal Research · doi:10.1111/jpi.70019 · Cited by 18
Dunkley, A. J., Tyrer, F., Spong, R., Gray, L. J., Gillett, M., Doherty, Y., Martin-Stacey, L., Patel, N., Yates, T. E., Bhaumik, S., et al. (2017) · Programme Grants for Applied Research · doi:10.3310/pgfar05110 · Cited by 16
“Subsequently, time spent in sedentary, light-intensity and MVPA activities was calculated for each participant-day using validated cut-points.(230) Sleep time was estimated using a defined algorithm (Activinsights Ltd) and subtracted from total sedentary time, in order to calculate time spent sedentary whilst awake.”
MethodBernard, P., Hains-Monfette, G., Atoui, S., & Moullec, G. (2018) · Canadian Respiratory Journal · doi:10.1155/2018/9107435 · Cited by 17
“*e digitized values are summed over a user-specified interval of 1 minute, resulting in a count value per minute (cpm) and steps accumulated per minute [21].”
BackgroundMatricciani, L., Paquet, C., Fraysse, F., Wake, M. A., & Olds, T. (2020) · Sleep Medicine · doi:10.1016/j.sleep.2020.04.017 · Cited by 17
Fenton, S., Burrows, T. L., Collins, C. E., Holliday, E. G., Kolt, G. S., Murawski, B., Rayward, A. T., Stamatakis, E., Vandelanotte, C., & Duncan, M. J. (2021) · Appetite · doi:10.1016/j.appet.2021.105273 · Cited by 16
Mitchell, B. L., Smith, A. E., Rowlands, A. V., Parfitt, G., & Dollman, J. (2018) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2018.05.002 · Cited by 18
Self-citationDomingo, C. H., Hernando, C., Martínez‐Navarro, I., Collado‐Boira, E., Panizo, N., & Hernando, B. (2020) · Scientific Reports · doi:10.1038/s41598-020-58492-8 · Cited by 20
Camerlingo, N., Kabiri, N. S., Psaltos, D., Kelly, M., Wicker, M. K., Messina, I., Auerbach, S. H., Zhang, H., Messere, A., Karahanoğlu, F. I., et al. (2023) · Gerontology · doi:10.1159/000535283 · Cited by 15
Kolk, M. Z. H., Frodi, D. M., Langford, J., Meskers, C. J. W., Andersen, T. O., Jacobsen, P. K., Risum, N., Tan, H. L., Svendsen, J. H., Knops, R. E., et al. (2023) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcad069 · Cited by 18
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.