Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 601–650 of 650
Gough, C., Lewis, L. K., Barr, C. J., Maeder, A., & George, S. (2021) · Figshare · doi:10.6084/m9.figshare.14337636
Gough, C., Barr, C., Lewis, L. K., Hutchinson, C. L., Maeder, A., & George, S. (2024) · Figshare · doi:10.6084/m9.figshare.26564205
Gough, C., Barr, C., Lewis, L. K., Hutchinson, C., Maeder, A., & George, S. (2024) · Figshare · doi:10.6084/m9.figshare.26564202
Wrist-Worn Accelerometer Measures of Activity by People with Parkinson's Attending Dance Classes
Hadley, R. (2022) · University of Hertfordshire Research Archive (University of Hertfordshire) · doi:10.18745/th.27448
Raslescu, A. (2024) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-pv8avbxdq · Cited by 1
Gough, C., Lewis, L. K., Barr, C. J., Maeder, A., & George, S. (2021) · Figshare · doi:10.6084/m9.figshare.14337630
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.25566238
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759525
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759534
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759528
Additional file 1 of Physical activity assessment by accelerometry in people with heart failure
Dibben, G. O., Gandhi, M. M., Taylor, R. S., Dalal, H. M., Metcalf, B. S., Doherty, P., Tang, L. H., Kelson, M., & Hillsdon, M. M. (2020) · Figshare · doi:10.6084/m9.figshare.12799483
Schwendinger, F., Wagner, J., Infanger, D., Schmidt-Trucksäss, A., & Knaier, R. (2021) · Figshare · doi:10.6084/m9.figshare.17010147
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.26703823
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759531
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.25566404
Additional file 2 of Physical activity assessment by accelerometry in people with heart failure
Dibben, G. O., Gandhi, M. M., Taylor, R. S., Dalal, H. M., Metcalf, B. S., Doherty, P., Tang, L. H., Kelson, M., & Hillsdon, M. M. (2020) · Figshare · doi:10.6084/m9.figshare.12799486
Flammer, F., Paraschiv-Ionescu, A., & Marques-Vidal, P. M. (2024) · Figshare · doi:10.6084/m9.figshare.25210585
Calibration and application of intensity thresholds to measure physical activities in adults
Mendes, M. D. A. (2018) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Laroche, M.-A. (2023) · Archipel (Université du Québec à Montréal)
Coirolo del Río, N. C. (2021) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 2
Using Bio-logging to Improve Sheep Health and Performance
(13704931), E. P. (2023) · Open Research Exeter (University of Exeter) · Cited by 1
Sleep of pre-school children and their parents : FinAdo substudy
Rönnlund, H. (2023) · UTUPub (University of Turku) · Cited by 1
Hains-Monfette, G. (2020) · Archipel (Université du Québec à Montréal) · Cited by 1
Ritmos circadianos humanos desafiados por las condiciones ambientales de la Antártida
Castillo, J. (2023) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Gilić, B., Vuletić, P. R., & Matijašević, P. (2025) · Kinesiologia Slovenica scientific journal on sport · doi:10.52165/kinsi.31.3.67-83 · Cited by 1
Sharma, Y., Castellanos, J., Suero-Tejeda, N. M., Bockting, W. O., Kronish, I. M., Schwartz, J. E., Wall, M. M., & Caceres, B. A. (2025) · BMC Public Health · doi:10.1186/s12889-025-24061-9
“GENEActiv has been shown to be valid and reliable for measuring sleep and physical activity (Activ-insights Ltd, Kimbolton, UK) in over 800 peer-reviewed publications [80–82].”
Sleep assessment using accelerometry: Not all algorithms are equal
Zhou, R., & Marques-Vidal, P. M. (2026) · Sleep research. · doi:10.1002/slp2.70021
“26 This software provides information on sleep duration (in minutes), sleep efficiency (in percentage), and sleep onset (in hours:minutes).”
Boudreaux, B. D., Xu, C., Sanchez, G. J., Murdock, M. E., Cruz, G. J., Jurado, A., Gonzales, A., Ellis, J., Diaz, F., Chang, M. J., et al. (2026) · Journal of General Internal Medicine · doi:10.1007/s11606-025-10137-0
Boord, M. S., Brown, P., Soriano, J., Meola, T. R., Dumuid, D., Milte, R., Roughead, E. E., Lovell, N. H., Janetzki, J. L., Lim, E., et al. (2026) · doi:10.2196/preprints.91107
Voutsas, G. T. (2025) · TSpace (University of Toronto)
Acute Effect of a Physical Education Lesson on Attention in a Population of Adolescents
Cocca, A., Unterkircher, J., Cocca, M., & Kopp, M. (2026) · Quest · doi:10.1080/00336297.2026.2641133
Garnotel, M. (2019) · theses.fr (ABES) · doi:10.70675/549cbe00z8e96z4c64z80d2za992673734e9
Continuous observation of Parkinsonian symptoms using symptom diaries & wearable accelerometry
Nesser, T. P. R., van der Linden, C., Schedlich‐Teufer, C., Brandt, G. A., Barbe, M. T., & Dembek, T. A. (2026) · Scientific Data · doi:10.1038/s41597-026-06999-6
“No technical validation was performed for this study since the GENEActiv device is a validated and widely used raw data accelerometry device 15,23,25–27 .”
Resting-state brain activity and association with physical activity
Koromila, G., Dyrba, M., Wolf, D., Fischer, F., Knaepen, K., Kollmann, B., Binder, H., Mierau, A., Riedel, D., Fellgiebel, A., et al. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1765112
“These devices are validated (Esliger et al., 2011) and were found to be comparable to the well-established ActiGraph (ActiGraph, Pensacola, United States) (Hildebrand et al., 2014).”
Piccolo, D. D., Corbett, J., Exell, T., Moore, J. M., Wright, A., Alnajjar, M. G. A., Hudson, L. C., Marsh, P. A., Praskacova, V., McNarry, M. A., et al. (2026) · Experimental Physiology · doi:10.1113/ep093501
“Habitual physical activity (PA) was assessed using GENEActiv (Activinsights, Kimbolton, UK) accelerometers, which are accurate and reliable for assessing PA and sedentary time in adults (Esliger et al., 2011; Pavey et al., 2016).”
Rest-activity rhythm across the clinical spectrum of depression among adolescents
Cho, T. S. M., So, S. F., Wu, D. C. H., Chau, S. W. H., Chan, S. S., Mo, F. Y. M., Ching, E. W.-K., Wong, O. W. H., Lai, K. Y. C., Ma, S. L., et al. (2026) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2026.05.030
Krikorian, A., Lecocq, B., Pen, M. L., Rollet, A., Gouy, E., Mura, M., Métais, A., Spiegel, K., Pelloux, S., Haesebaert, J., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-9094809/v1
Armstrong, D. G., Mikosiński, J., Pańczak, K., Węgrzynowski, A., Piechota, D., Kotala, M., Lipiński, P., Rybołowicz, K., Lipinska, A., Veličković, V. M., et al. (2026) · Medical Devices Evidence and Research · doi:10.2147/mder.s619815 · Cited by 1
“21 The final study visit occurred at week 6 or earlier in the event of complete healing, withdrawal, or dressing discontinuation.”
Schlatter, S., Mura, M., Bertrand, M. F., Morel, B., Loisel, O., Aouidat, M., Gouraud, É., Henry, A., Hautier, C. A., Pialoux, V., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-8944455/v1
de Vries, E. A., Grauwmeijer, E., Ista, E., Heer, S. J. A. B.-D., Cramm, J. M., Ribbers, G. M., van den Berg-Emons, R. J. G., & Heijenbrok‐Kal, M. H. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-118358
Recacha-Ponce, P., Hernando, C., Seder, A. C., Collado‐Boira, E., Suárez-Alcázar, M. P., Medina, P. S., & Domingo, C. H. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2026.1793624
“Objective monitoring of daily PA through accelerometers provides a robust method to quantify movement patterns and energy consumption across the MC (14 – 17).”
Svensen, E., Koscien, C. P., Abdelrahman, D. R., Murton, A. J., Alamdari, N., Wall, B. T., & Stephens, F. B. (2026) · The Journal of Nutritional Physiology · doi:10.1016/j.jnphys.2026.100038
van de Camp, S. A. J. H., Brenninkmeijer, R., van Doorn, J. L. M., de Laat, E. C. M., Pomp, L., Stinissen, L., Cameron, D., Groothuis, J. T., van Alfen, N., Jungbluth, H., et al. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-119529
Camerlingo, N., Koffman, L. J., Adamowicz, L., Moustridi, E., & Karahanoğlu, F. I. (2026) · Sensors · doi:10.3390/s26165194
“The development and validation of these algorithms require reference measures of energy expenditure or activity intensity, such as calorimetry devices [23], or standardized resources like the Compendium of Physical Activities [17].”
Firkin, C. J. (2025) · Library, Museums and Press - UDSpace (University of Delaware)
Physical Activity and Frailty in patients with Advanced Chronic Liver Disease: A prospective study
Williams, F. R., Quinlan, J. I., Dhaliwal, A., Nicholson, T. A., Breen, L., Greig, C. A., Elsharkawy, A. M., Lord, J. M., Rowlands, A. V., & Armstrong, M. J. (2026) · JHEP Reports · doi:10.1016/j.jhepr.2026.102072
Self-citationLangford, J., Chua, J. Y., Long, I., Williams, A. C., & Hillsdon, M. M. (2026) · PLoS ONE · doi:10.1371/journal.pone.0346458
“The typical sedentary to active threshold for AGSA of 62.5m g [66,73] is shown vertically in Fig 4.”
InfluentialCnudde, K., Maenhout, L., Backere, F. D., Ongenae, F., & Dyck, D. V. (2026) · British Journal Of Nutrition · doi:10.1017/s0007114526108526
Use of accelerometry to predict energy expenditure in military tasks
Horner, F. E. (2012) · The University of Bath Online Publications Store (The University of Bath)
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.