PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 501–600 of 650
Eyre, E. L. J., Tallis, J. A., Wilson, S., Wilde, L., Akhurst, L., Wanderleys, R., & Duncan, M. J. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0028 · Cited by 1
Flammer, F., Paraschiv-Ionescu, A., & Marques-Vidal, P. M. (2024) · BMC Cardiovascular Disorders · doi:10.1186/s12872-024-03755-9 · Cited by 1
“Data were then analysed using the GENEActiv macro file ‘General physical activity’ version 1.9, which had been previously validated [18].”
MethodInfluentialJäger, C., Ryan, M., Rommers, N., Schär, J., Weibel, R., Kressig, R. W., Schmidt‐Trucksäss, A., Engelter, S. T., Peters, N., Hinrichs, T., et al. (2024) · SAGE Open Medicine · doi:10.1177/20503121241281147 · Cited by 1
“Acceler-ometer data were converted into the metabolic equivalent of task (MET) using the protocol by Esliger et al. 23 In short, they synchronized accelerometer data during various activities with the measurement of V’O 2 .”
Sequeira, L., Fadaiefard, P., Seat, J., Aitken, M., Strauss, J., Wang, W., Szatmári, P., & Battaglia, M. (2024) · Child and Adolescent Psychiatry and Mental Health · doi:10.1186/s13034-024-00843-8 · Cited by 1
“The GENEActiv device has been validated against reference methods and proved reliable and valid by several studies [30–33].”
Booth, G., Bearne, L., D’Lima, D., Hudda, M. T., & USSHER, M. H. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-103763 · Cited by 1
Nissen, R., Fraga, K., Wöll, A., Vega‐López, S., Krell‐Roesch, J., & Crespo, N. C. (2025) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2025.1560435 · Cited by 1
Williams, C. A., Button, B., Dwyer, T., Hatziagorou, E., Mackintosh, K. A., McNarry, M. A., Paris, D., Shelley, J., Hebestreit, H. U., Bradley, J. M., et al. (2025) · European Respiratory Review · doi:10.1183/16000617.0279-2024 · Cited by 1
Zout, G., Höver, C., Eggert, E., Gunga, H., Ouèrmi, L., Sié, A., Huhn, S., Bunker, A., Barteit, S., Mendt, S., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0330835 · Cited by 2
“The GENEActiv accelerometer has been previously validated regarding its technical reliability against a mechanical shaker and for its estimation of physical activity against VO2 as the criterion measure [29].”
Vella‐Baldacchino, M., Heegaard, J., Snorre, S., Soeren, R., Kristensen, W. P., Zahid, A., Liddle, A. D., Cobb, J. P., & Odgaard, A. (2025) · Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · doi:10.1016/j.jisako.2025.101037 · Cited by 2
Gilić, B., Vuletić, P. R., Maras, N., Sekulić, D., & Šajber, D. (2025) · Applied Sciences · doi:10.3390/app152312728 · Cited by 1
Cherednichenko, A., Baena-Pérez, M., Beltran‐Valls, M. R., Moliner‐Urdiales, D., & Ávila, C. (2026) · Behavioral and Brain Functions · doi:10.1186/s12993-026-00318-0 · Cited by 1
“It also features a body temperature sensor to distinguish wear from non-wear periods, and has demonstrated strong reliability, with intra-and inter-instrument coefficients of variation of 1.4% and 2.1%, respectively, and has been validated for assessing PA in young adults [36].”
InfluentialLi, B., Liu, Y., Li, W., Ma, Y. T. J., Huss, A., Chan, J. W. Y., Wing, Y. K., & Tse, L. A. (2026) · Occupational and Environmental Medicine · doi:10.1136/oemed-2026-111078 · Cited by 1
Xie, H., Xue, F., & Wang, X. (2026) · Lifetime Data Analysis · doi:10.1007/s10985-026-09721-1 · Cited by 1
Musculoskeletal and physiological responses to vortex wave stimulation in older adults
Waddell, A., Korzepa, M., Belfield, A., Fry, B., Mesquita, R. C., Smith, D. R., Quinlan, J. I., & Breen, L. (2026) · The Journal of Physiology · doi:10.1113/jp291437 · Cited by 1
“Time spent in sedentary, light, moderate and vigorous activity was calculated based on previously published cut-off values (Esliger et al., 2011).”
Woodman, J. A. (2015) · Cited by 1
Validity of activity measurement using a smart phone
Hammoud, A., Jaber, R., & Othman, H. (2017) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme.2017.8167520 · Cited by 2
“Previous researchers have recognized that this in one of the difficulties encountered in these types of validation studies [20, 24, 26, 27].”
BackgroundAtkins, C., Jones, A., & Wilson, A. M. (2018) · Sarcoidosis vasculitis and diffuse lung diseases · doi:10.36141/svdld.v35i1.5848 · Cited by 1
“Thresholds for activity vigour within this spreadsheet were taken from previous data by Esliger et al(25) and adjusted for the sampling frequency of the accelerometers, leading to differences in”
MethodPhysische Aktivität bei älteren Menschen mit Augenerkrankungen
Heinemann, M., Welker, S., Holz, F. G., & Finger, R. P. (2018) · Der Ophthalmologe · doi:10.1007/s00347-018-0688-y · Cited by 1
Tickell, A. M., Rohleder, C., Garland, A., Song, Y. J. C., Carpenter, J. S., Harel, K., Parker, L., Hickie, I. B., & Scott, E. M. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-038787 · Cited by 1
Zillmer, R., Newby, B., & Treloar, R. L. (2014) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0004789701780182 · Cited by 2
“The reliability and performance of this sensor has been validated in several studies (Esliger et al., 2011; Zhang et al., 2012).”
Health Promotion in Children and Adolescents through Sport and Physical Activities
Bianco, A. (2019) · MDPI eBooks · doi:10.3390/books978-3-03897-887-9 · Cited by 1
Quantitative assessment of sitting time in ambulant adults with Muscular Dystrophy
Jacques, M. F., Onambélé-Pearson, G. L., Edwards, B. T., Goede, C. G. E. L. D., & Morse, C. I. (2021) · PLoS ONE · doi:10.1371/journal.pone.0260491 · Cited by 2
Green, E. T., Cox, N. S., & Holland, A. E. (2021) · Journal of Aging and Physical Activity · doi:10.1123/japa.2021-0256 · Cited by 1
Albertyn, C. P., Johar, I., Creese, B., Young, A. H., Carter, B., Velayudhan, L., Bhattacharyya, S., Silva, M. V. D., Samsi, K., Jafari, H., et al. (2023) · Health Open Research · doi:10.12688/healthopenres.13311.1 · Cited by 2
Salway, R., Augustin, N. H., & Armstrong, M. E. G. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20146401 · Cited by 1
“For the purposes of this paper, sedentary refers to accelerations of <60 mg [25,26].”
BackgroundMethodInfluentialASPECTOS E FATORES ASSOCIADOS À OBESIDADE NA ADOLESCÊNCIA
Durans, L. H. F., Miranda, T. D. C., Silva, H. N. D. S. E., Santos, E. R. V., Leitão, S., & Mostarda, C. T. (2023) · doi:10.22533/at.ed.3512328099 · Cited by 1
척수손상 장애인 신체활동 평가도구 개발을 위한 타당도 검증*
이, 나., 박, 세., & 이, 민. (2024) · 한국체육학회지 · doi:10.23949/kjpe.2024.9.63.5.29 · Cited by 1
Kinuthia, S. K., Stratton, G., Wachira, L.-J. M., Okoth, V., Owino, G., Ochola, S., Kiplamai, F., Onywera, V. O., & Swindell, N. J. (2025) · PLoS ONE · doi:10.1371/journal.pone.0329173 · Cited by 1
Gosal, R., Weaver, G., Parker, H., Burkart, S. A., McAninch, J., Lane, A. D., Smith, M. T., HILL, S., PATE, R. R., Chandrashekhar, M. V. S., et al. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003841 · Cited by 1
Filáková, K., Štěpánová, J., & Jakubec, L. (2019) · Tělesná kultura · doi:10.5507/tk.2019.002 · Cited by 1
“V zahraničních studiích se autoři nejčastěji přiklánějí k upnutí akcelerometrů na tělo probandů do oblasti hrudního koše, do oblasti pasu, na stehno nebo na dorzální stranu zápěstí (Esliger et al., 2011; García-Massó et al., 2013).”
Acceptability and efficacy of a low intensity family-based weight loss intervention
Benzo, R. M., Carr, L. J., Janz, K. F., & Tucker, S. J. (2015) · doi:10.17077/etd.zvk2s3r2 · Cited by 1
Physical Activity in Adolescents with respect to Movement Quality and Quantity
Weedon, B. D. (2020) · Radar (Oxford Brookes University) · doi:10.24384/381r-t238 · Cited by 3
Mansoubi, M., Esser, P., Meaney, A., Metz, R., Beunder, K., & Dawes, H. (2019) · doi:10.21203/rs.2.18186/v1 · Cited by 1
“Below equation used to calculate the signal vector magnitude (gravity-subtracted) (SVMgs), in 1s epochs.33 According to Esliger et al (2011) the unit of the following equation result would be gs.34 [Due to technical limitations the formula could not be displayed here.”
MethodSánchez, A. S. (2022) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · doi:10.6035/14112.2022.806228 · Cited by 1
Kapteyn, A., Kapteyn, A., & Darling, J. E. (2021) · Survey research methods · doi:10.18148/srm/2024.v18i3.8308 · Cited by 1
Evaluation de la fragilité chez les personnes âgées avec un smartphone
Hammoud, A. (2015) · theses.fr (ABES) · doi:10.70675/20c3d4bcz3012z4be6zaf60z07412c113f87 · Cited by 3
Forseth, B. M. (2014) · Cited by 4
SEMI-AUTOMATIC FALLS RISK ESTIMATION OF ELDERLY ADULTS USING SINGLE WRIST WORN ACCELEROMETER
Pandi, S. G., & Kumar, S. A. (2014)
Self-monitoring of physical frailty : a proactive approach in community-dwelling elderly people
Vermeulen, J. (2014) · Research Publications (Maastricht University) · doi:10.26481/dis.20141216jv · Cited by 1
Physical activity, body mass index and prostate cancer : studies of risk, progression and mortality
Bonn, S. E. (2015) · Figshare
Metcalf, K. M. (2013) · doi:10.17077/etd.ujsum0tt · Cited by 1
“Validated acceleration magnitude cutpoints from Esliger and colleagues were used to classify activity intensity (Esliger et al., 2011).”
BackgroundMethodInfluentialDIAVIP - Diabetes Prevention in Primary Care - Implications for Physical Activity
Hellgren, M. I. (2014) · Gothenburg University Publications Electronic Archive (Gothenburg University)
Implementation and pilot testing of an Android-based real-time activity detection system
Sun, Y. (2013) · Digital Repository Service (Northeastern University) · doi:10.17760/d20003208
Remaining Questions Concerning Wearable Devices
Lee, P. H. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2016.4750
Gait monitoring : from the clinics to the daily life
Storm, F. A. (2016) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Objectively measured sedentary behaviour, physical activity and health in adolescent females
Dowd, K. (2012) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/7228
Fadel, W. F. (2017) · doi:10.7912/c26q0j
“However, the usual method for describing PA in the free-living environment is to use activity counts and a cut-point approach which classifies intensities of PA rather than the specific activity occurring [Esliger et al. (2011); Straczkiewicz et al.”
MethodInfluentialGorzelniak, L. (2013) · mediaTUM (Technical University of Munich)
Rowlands, A. V., & Stiles, V. H. (2011) · Open Research Exeter (University of Exeter)
Self-citationDaniels, B. T. (2018) · Journal of the Arkansas Academy of Science
손윤선, Kwang, K. J., Lee, D., 황봉연, 이종도, & 김기언 (2016) · The Korean Journal of Measurement and Evaluation in Physical Education and Sports Science · doi:10.21797/ksme.2016.18.2.001
Exploring Sedentary Behavior as a Secondary Prevention Target for Heart Disease
Duran, A. T. (2019) · Columbia Academic Commons (Columbia University) · doi:10.7916/d8-fcbj-ab52
García, C. S. (2019) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · doi:10.6035/14113.2019.253115 · Cited by 2
Lines, R. L. J. (2019) · eSpace (Curtin University)
The next day effects of a normal night's drinking on cognition and human performance
Devenney, L. E. (2019) · Ulster University Research Portal (Ulster University)
Dyadic Interventions to Promote Physical Activity
Carr, R. M. (2019) · eSpace (Curtin University)
La composición de los espacios verdes y niveles de actividad física de la gente mayor en Barcelona
Vich, G., Dopico, J., & Miralles‐Guasch, C. (2019) · 9° Congresso Città e Territorio Virtuale, Roma, 2, 3 e 4 ottobre 2013 · doi:10.5821/ctv.8555
“Siguiendo a Esliger et al. (2011), se usó un umbral de <216 recuentos de VM por minuto para definir el tiempo sedentario, donde más de 216 recuentos de VM se clasificaron como "activos".”
BackgroundWearable Technology and the Measurement of Physical Activity Intensity and Volume
Weber, K. S. (2020) · UWSpace (University of Waterloo)
Kim, H. J., Yoon, J. K., Kim, S. H., & Jae, S. Y. (2020) · The Korean Journal of Sports Medicine · doi:10.5763/kjsm.2020.38.4.225
Schilling, R. (2020) · edoc (University of Basel) · doi:10.5451/unibas-ep78116
Gough, C., Hutchinson, C. L., Barr, C., Maeder, A., & George, S. (2021) · The Allied Health Scholar · doi:10.21913/tahs.v2i1.1572 · Cited by 1
Physical Activity and Sleep in Gynecological Cancer Survivors
Lopez, P. (2020) · TSpace (University of Toronto) · Cited by 1
Dairo, Y. M. (2017) · Radar (Oxford Brookes University) · doi:10.24384/a8tb-w925
Ezekiel, L. (2020) · Radar (Oxford Brookes University) · doi:10.24384/2zdw-pz12
Accelerometer measurement differences between the preferred and non-preferred wrist
Daniels, B. T., Gallagher, K. M., Gray, M., & Howie, E. K. (2021) · Health and Technology · doi:10.1007/s12553-021-00608-9
Tired of being tired: Fatigue and sleep following traumatic brain injury
Bruijel, J. (2021) · Research Publications (Maastricht University) · doi:10.26481/dis.20211201jb
Wrench, L. (2021) · Lancaster EPrints (Lancaster University) · doi:10.17635/lancaster/thesis/1476
Marshall, Z. A. (2021) · Cronfa (Swansea University) · doi:10.23889/suthesis.58608
Algunos aspectos de la fisiopatología hipofisaria
de Cañete, J. M. S. F. (1968) · Seminario médico
東南アジアの住居と居住環境に関する研究 その22 : インドネシアにおけるカンポンの変容過程とKIPの評価 その3 KIPの評価とインパクト・スタディー : 建築計画
内田, 雄., 前田, 尚., 太田, 邦., 上杉, 啓., 勝瀬, 義., 布野, 修., & 浅井, 賢. (1984) · 学術講演梗概集. 計画系
Bajo la RSE se pueden introducir lastres enormes para la eficiencia empresarial
Fernández, D., & Martín, J. E. I. (2006) · Corresponsables
García‐Alonso, Y. (2023) · Academica-e (Universidad Pública de Navarra) · doi:10.48035/tesis/2454/45481
Measures of Physical Activity in Parkinson’s Disease (MAPD)
Gilby, J., Carroll, C., & Marsden, J. F. (2023) · International Journal of Neurologic Physical Therapy · doi:10.11648/j.ijnpt.20230901.11 · Cited by 1
APTIDÃO FÍSICA, SAÚDE MENTAL E NUTRIÇÃO NO ADOLESCENTE
da Silva, L. P., Lima, G. D. S. O., Noleto, D. C. D. S., & do Nascimento, M. A. (2023) · doi:10.22533/at.ed.3512328097
EXERCÍCIO FÍSICO E ANSIEDADE NO ADOLESCENTE
Rabelo, A. S., de Oliveira, K. H. D. S., Abreu, L. M. S., Correia, M. B., & RIBEIRO, F. B. (2023) · doi:10.22533/at.ed.3512328092
Exercício físico e saúde do adolescente
Dias, C. J. M., Filho, C. A. A. D., Mostarda, C. T., & Costa, H. A. (2023) · doi:10.22533/at.ed.351232809
DEFINIÇÕES E CLASSIFICAÇÃO DA ADOLESCÊNCIA
Pereira, M. E. V., Oliveira, N. G., Ribeiro, P. R. F., da Silva, T. M. C., & Dias, C. J. M. (2023) · doi:10.22533/at.ed.3512328091 · Cited by 2
ASPECTOS ETIOPATOGÊNICOS DO CÂNCER DE TESTÍCULO EM ADOLESCENTES E SEU IMPACTO NA SAÚDE MENTAL
Filho, C. A. A. D., Ferreira, F. D., Ferreira, F. R. D., Carneiro, J. G. P., Neto, J. C. G. P., & Cardoso, M. E. S. (2023) · doi:10.22533/at.ed.3512328096
EXERCÍCIO FÍSICO E ADOLESCÊNCIA
Soares, N. D. J. S., Pires, F. D. O., & Cavalcante, L. F. P. (2023) · doi:10.22533/at.ed.3512328093
COMPORTAMENTO PARENTAL ASSOCIADO A FATORES DE RISCO CARDIOVASCULAR EM ADOLESCENTES
Costa, H. A., Rabelo, A. S., Costa, V. D. A. M., da Silva, F. E. L., & Pinto, B. F. P. (2023) · doi:10.22533/at.ed.3512328098
DIABETES MELLITUS TIPO 2 EM ADOLESCENTES E OS RISCOS DO DESENVOLVIMENTO DE INSUFICIÊNCIA CARDÍACA
Filho, C. A. A. D., de Carvalho, R. G. V., Carneiro, J. G. P., Neto, J. C. G. P., Rocha, L. T. S., & Rodrigues, P. A. V. (2023) · doi:10.22533/at.ed.3512328095
HIPERTENSÃO ARTERIAL NO ADOLESCENTE
Soares, N. D. J. S., Pires, F. D. O., & Cavalcante, L. F. P. (2023) · doi:10.22533/at.ed.3512328094
TREINAMENTO DE FORÇA, CRESCIMENTO E DESENVOLVIMENTO EM CRIANÇAS E ADOLESCENTES
Marques, R. F., & Ribeiro, R. M. (2023) · doi:10.22533/at.ed.35123280910
Salamin, O., Carrard, J., Teav, T., Schmidt‐Trucksäss, A., Gallart‐Ayala, H., & Ivanišević, J. (2023) · Learning materials in biosciences · doi:10.1007/978-3-031-44256-8_12
Methods of sedentary lifestyle study: possibilities and limitations
Pomeshkina, S. A., & Demchenko, E. A. (2024) · Russian Journal of Preventive Medicine · doi:10.17116/profmed20242705197
Tse-Hau, T. O. N. G., & Haozhen, W. A. N. G. (2024) · Gazzetta Medica Italiana Archivio per le Scienze Mediche · doi:10.23736/s0393-3660.23.05217-8
VonLanthen, G., & Marques-Vidal, P. M. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078929 · Cited by 1
Sepulveda, R. A. Y., Vargas-Silva, J., Serey-Galindo, F., Cristi‐Montero, C., Herrera-Amante, C. A., Arancibia, J. E. O., Cortés-Roco, G., & Zavala-Crichton, J. P. (2024) · Retos · doi:10.47197/retos.v61.108954
Cheung, M. A., Moulson, N., Gelinas, J. C., Daraei, A., Bradwell, S. M., Taylor, C. M., Eves, N. D., Koelwyn, G. J., & Roston, T. M. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100501 · Cited by 1
“Data from the GeneActiv watch will be uploaded monthly to an anonymized offline database for downstream analysis to calculate total physical activity (including light, moderate, and vigorous physical activity) using established methods [22 – 24].”
Maroni, T. D., Myers, S., Draper, L., Ashdown, K., Walker, F. S., Alexander, M. B., & Blacker, S. D. (2025) · Ergonomics · doi:10.1080/00140139.2025.2456538
“…a high instrument reliability and criterion validity, as well as demonstrate excellent classification accuracy of different intensities of physical activity (sedentary, light, moderate, and vigorous (Esliger et al. 2011)) and energy expenditure (EE) (Blacker et al. 2019; Siddall et al. 2019).”
InfluentialCaudroit, J., Lapointe, J., Comtois, Romain, A. J., & Bernard, P. (2024) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/zyh36_v1
Hoffman, M., Mellerick, C., Burge, A. T., & Holland, A. E. (2025) · Chronic Respiratory Disease · doi:10.1177/14799731251358584
“22 Data was extracted using the Geneactiv software that generates Excel fi les classifying recorded data for time spent in: no wear, bed, sedentary, light, moderate and vigorous intensity physical activity.”
Mobility During an Acute Medical Hospitalization: A Prospective Cohort Study
Liechti, F. D., Leuenberger, J. M. S., Verra, M. L., & Aubert, C. E. (2025) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2025.105915
Schlatter, S., Mura, M., Morel, B., Loisel, O., Aouidat, M., Gouraud, É., Henry, A., Hautier, C. A., Pialoux, V., Rode, G., et al. (2025) · Research Square · doi:10.21203/rs.3.rs-7441836/v1 · Cited by 1
Romeo, A., Edney, S. M., Plotnikoff, R. C., Olds, T., Vandelanotte, C., Ryan, J., Curtis, R., & Maher, C. A. (2021) · Figshare · doi:10.6084/m9.figshare.13544392
Gough, C., Lewis, L. K., Barr, C. J., Maeder, A., & George, S. (2021) · Figshare · doi:10.6084/m9.figshare.14337633
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.