Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 101–200 of 650
Kim, Y., White, T., Wijndaele, K., Sharp, S. J., Wareham, N. J., & Brage, S. (2017) · International Journal of Obesity · doi:10.1038/ijo.2017.122 · Cited by 66
Minaeva, O., Booij, S. H., Lamers, F., Antypa, N., Schoevers, R. A., Wichers, M., & Riese, H. (2020) · Translational Psychiatry · doi:10.1038/s41398-020-00952-w · Cited by 70
Gao, Z., Liu, W., McDonough, D. J., Zeng, N., & Lee, J. E. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10245951 · Cited by 74
Feasibility of three wearable sensors for 24 hour monitoring in middle-aged women
Huberty, J., Ehlers, D. K., Kurka, J. M., Ainsworth, B. E., & Buman, M. P. (2015) · BMC Women s Health · doi:10.1186/s12905-015-0212-3 · Cited by 69
“For behavioral feedback, the Esliger algorithm [25] was used to quantify wake periods and an excel macro provided by the manufacturer and consistent with the Sadeh algorithm [23] was used to quantify sleep periods.”
MethodActivity Classification Using the GENEA: Optimum Sampling Frequency and Number of Axes
ZHANG, S., MURRAY, P., ZILLMER, R., ESTON, R. G., CATT, M., & ROWLANDS, A. V. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31825e19fd · Cited by 58
Self-citationChallenges and Opportunities for Harmonizing Research Methodology: Raw Accelerometry
van Hees, V., Thaler-Kall, K., Wolf, K.-H., Brønd, J., Bonomi, A., Schulze, M., Vigl, M., Morseth, B., Hopstock, L. A., Gorzelniak, L., et al. (2016) · Methods of Information in Medicine · doi:10.3414/me15-05-0013 · Cited by 58
“of raw accelerometry has been around since the 1990s but has only become fea sible for the use in the assessment of weeklong human physical activity since the first decade of this century [2, 3].”
BackgroundSanders, G. J., Boddy, L. M., Sparks, S. A., Curry, W. B., Roe, B. H., Kaehne, A., & Fairclough, S. J. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1555904 · Cited by 71
“Interunit reliability is acceptable for both brands (Esliger et al., 2011; Santos-Lozano et al., 2012).”
BackgroundDaneault, J., Vergara-Diaz, G. P., Parisi, F., Admati, C., Alfonso, C., Bertoli, M., Bonizzoni, E., Carvalho, G. F., Costante, G., Fabara, E. E., et al. (2021) · Scientific Data · doi:10.1038/s41597-021-00830-0 · Cited by 73
Effects of Standing and Light-Intensity Walking and Cycling on 24-h Glucose
CRESPO, N. C., MULLANE, S. L., ZEIGLER, Z. S., BUMAN, M. P., & GAESSER, G. A. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001062 · Cited by 58
“Time spent in sedentary, light-, moderate-, and vigorous-intensity physical activities was calculated using published algorithms (15).”
MethodSchimpl, M., Lederer, C., & Däumer, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023080 · Cited by 62
“Comparable devices such as GENEA [23] and Philips DirectLife [24] lack a standardized method of attachment.”
MethodActive Video Games Improve Muscular Fitness and Motor Skills in Children with Overweight or Obesity
Comeras-Chueca, C., Villalba-Heredia, L., Pérez-Lasierra, J. L., Marín-Puyalto, J., Lozano‐Berges, G., Matute-Llorente, Á., Vicente‐Rodríguez, G., González‐Agüero, A., & Casajús, J. A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052642 · Cited by 72
Dillon, C. B., McMahon, E. M., Cully, G., & Perry, I. J. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-018978 · Cited by 65
Calibration and cross‐validation of a wrist‐worn Actigraph in young preschoolers
Johansson, E., Ekelund, U., Nero, H., Marcus, C., & Hagströmer, M. (2015) · Pediatric Obesity · doi:10.1111/j.2047-6310.2013.00213.x · Cited by 57
“Wrist-worn accelerometers have shown good validity regarding accelerometer counts and PA energy expenditure in school-aged children and adults (14,15).”
BackgroundLee, P. H., & Tse, A. C. Y. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.023 · Cited by 62
Issues Related to Measuring and Interpreting Objectively Measured Sedentary Behavior Data
Janssen, X., & Cliff, D. P. (2015) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2015.1045908 · Cited by 67
“In addition, studies examining both accelerometers on the hip and wrist reported the accuracy of the wrist-worn devices was comparable or lower to the accuracy of hip-worn devices when examining sedentary behavior (Esliger et al., 2011; Phillips et al., 2013; Welch et al., 2014, 2013; Zhang et al., 2012).”
BackgroundResultInfluentialFairclough, S. J., Tyler, R., Dainty, J. R., Dumuid, D., Richardson, C., Shepstone, L., & Atkin, A. J. (2021) · Journal of Sports Sciences · doi:10.1080/02640414.2021.1890351 · Cited by 59
“Wrist-worn accelerometers have demonstrated excellent validity against energy expenditure (37) and can accurately classify physical activity intensities in youth (38, 39).”
BackgroundNightingale, T. E., Walhin, J., Thompson, D., & Bilzon, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126086 · Cited by 62
“This device has been explained in detail elsewhere [20].”
MethodEstablishing Raw Acceleration Thresholds to Classify Sedentary and Stationary Behaviour in Children
Hurter, L., Fairclough, S. J., Knowles, Z. R., Porcellato, L. A., Cooper-Ryan, A. M., & Boddy, L. M. (2018) · Children · doi:10.3390/children5120172 · Cited by 62
“Two studies that compared wrist placements [19,20] found no significant differences between these two sites; however, these studies did not differentiate between dominant and non-dominant wrists, but rather compared the right side with the left.”
ResultVich, G., Delclòs‐Alió, X., Maciejewska, M., Marquet, O., Schipperijn, J., & Miralles‐Guasch, C. (2021) · Urban forestry & urban greening · doi:10.1016/j.ufug.2021.127225 · Cited by 59
The feasibility of online video calling to engage patients with cystic fibrosis in exercise training
Tomlinson, O. W., Shelley, J., Trott, J., Bowhay, B., Chauhan, R., & Sheldon, C. D. (2019) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x19828630 · Cited by 59
Physical Activity Intensity Cut-Points for Wrist-Worn GENEActiv in Older Adults
Fraysse, F., Post, D., Eston, R. G., Kasai, D., Rowlands, A. V., & Parfitt, G. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.579278 · Cited by 58
“nondominant wrist, and we know that acceleration, and therefore cutpoints, can be different between wrists for the same activity (Esliger et al., 2011; Phillips et al., 2013; Duncan et al., 2019).”
BackgroundSelf-citationWalton, M. K., Cappelleri, J. C., Byrom, B., Goldsack, J. C., Eremenco, S., Harris, D. A., Potero, E., Patel, N., Flood, E. M., & Däumer, M. (2020) · Contemporary Clinical Trials · doi:10.1016/j.cct.2020.105962 · Cited by 54
Curtis, R., Dumuid, D., Olds, T., Plotnikoff, R. C., Vandelanotte, C., Ryan, J. C., Edney, S. M., & Maher, C. A. (2020) · Journal of Physical Activity and Health · doi:10.1123/jpah.2018-0687 · Cited by 61
Novel CPET Reference Values in Healthy Adults: Associations with Physical Activity
Wagner, J., Knaier, R., Infanger, D., Königstein, K., Klenk, C., Carrard, J., Hanssen, H., Hinrichs, T., Seals, D. R., & Schmidt‐Trucksäss, A. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002454 · Cited by 58
Stiles, V. H., Metcalf, B. S., Knapp, K. M., & Rowlands, A. V. (2017) · International Journal of Epidemiology · doi:10.1093/ije/dyx080 · Cited by 50
“non-dominant wrist are minimal at higher intensities.(31) Therefore, unless an activity that dominates on one side is taking place, e.”
BackgroundMethodSelf-citationRowlands, A. V., Plekhanova, T., Yates, T. E., Mirkes, E. M., Davies, M. J., Khunti, K., & Edwardson, C. L. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0073 · Cited by 60
Self-citationPredicting Physical Activity Energy Expenditure in Manual Wheelchair Users
Nightingale, T. E., Walhin, J., Thompson, D., & Bilzon, J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000291 · Cited by 56
“The authors also used a smaller-scale vibration table as opposed to a MAST rig; it is unclear whether the vibration table was separated from the electric motor to minimize the mechanical vibration, as advocated previously (10).”
MethodRoscoe, C. M. P., James, R. S., & Duncan, M. J. (2017) · European Journal of Pediatrics · doi:10.1007/s00431-017-2948-2 · Cited by 52
“Accelerometer counts for the activities were coded into binary indicator variables (0 or 1), as multiple separate analyses were completed, based on the intensity (sedentary versus > sedentary, less than moderate versus moderate) allowing receiver operator characteristic (ROC) curve analysis to be performed and the cal…”
MethodInfluentialImpact of study design on development and evaluation of an activity-type classifier
van Hees, V. T., Golubic, R., Ekelund, U., & Brage, S. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00984.2012 · Cited by 49
“The triaxial accelerometer (GENEA, Unilever Discover) has been described in detail elsewhere (10, 28).”
MethodTaylor, A. H., Taylor, R. S., Ingram, W. M., Anokye, N., Dean, S. G., Jolly, K. B., Mutrie, N., Lambert, J. D., Yardley, L., Greaves, C. J., et al. (2020) · Health Technology Assessment · doi:10.3310/hta24630 · Cited by 55
Pentecost, C., Farrand, P., Greaves, C. J., Taylor, R. S., Warren, F. C., Hillsdon, M., Green, C., Welsman, J. R., Rayson, K., Evans, P. H., et al. (2015) · Trials · doi:10.1186/s13063-015-0881-0 · Cited by 44
“2; ActivInsights, Kimbolton, UK [36]) and converted to a signal vector magnitude using a previously published equation [39].”
MethodNygaard, I., Clark, E., Clark, L., Egger, M. J., Hitchcock, R. W., Hsu, Y., Norton, P., Sanchez-Birkhead, A., Shaw, J. M., Sheng, X., et al. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-014252 · Cited by 49
Cooper, N., Bassett, D. S., & Falk, E. B. (2017) · Scientific Reports · doi:10.1038/srep43250 · Cited by 48
Sleep after Heavy Alcohol Consumption and Physical Activity Levels during Alcohol Hangover
Devenney, L. E., Coyle, K. B., Roth, T. G., & Verster, J. C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8050752 · Cited by 48
“[29] has validated and calibrated the GENEActiv accelerometer using Metabolic Equivalent of Tasks (METs) and Signal Vector Magnitudes (SVM, magnitude of watch movement).”
BackgroundMethodMaher, C. A., Olds, T., Vandelanotte, C., Plotnikoff, R. C., Edney, S. M., Ryan, J. C., DeSmet, A., & Curtis, R. (2022) · Games for Health Journal · doi:10.1089/g4h.2021.0207 · Cited by 52
“Each 60-second epoch of waking time was classified using Esliger’s cutpoints.(21) A 5:2 weighting was applied ((5 · [average of week days] + 2 · [average of weekend days])/7) to calculate daily minutes of MVPA.”
Assessment of sleep and circadian rhythm disorders in the very old: the Newcastle 85+ Cohort Study
Anderson, K. N., Catt, M., Collerton, J. C., Davies, K., von Zglinicki, T., Kirkwood, T. B. L., & Jagger, C. (2013) · Age and Ageing · doi:10.1093/ageing/aft153 · Cited by 47
“The GENEA records continuous acceleration rather than epoch-based summary measures more typical of studies employing commercial actiwatches (actigraphy) and has been validated for monitoring activity levels [13].”
BackgroundSelf-citationDeterminants of Bone Outcomes in Adolescent Athletes at Baseline: The PRO-BONE Study
Vlachopoulos, D., Ubago‐Guisado, E., BARKER, A. R., Metcalf, B. S., Fatouros, I. G., Avloniti, A. A., KNAPP, K. M., Moreno, L. A., Williams, C. A., & Gracia‐Marco, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001233 · Cited by 50
“Physical activity was measured for seven consecutive days using validated wrist accelerometers (GENEActiv, GENEA, UK) (7).”
MethodFunctional aging in health and heart failure: the COmPLETE Study
Wagner, J., Knaier, R., Infanger, D., Arbeev, K. G., Briel, M., Dieterle, T., Hanssen, H., Faude, O., Roth, R., Hinrichs, T., et al. (2019) · BMC Cardiovascular Disorders · doi:10.1186/s12872-019-1164-6 · Cited by 50
Matricciani, L., Dumuid, D., Paquet, C., Fraysse, F., Wang, Y., Baur, L. A., Juonala, M., Ranganathan, S., Lycett, K., Kerr, J. A., et al. (2021) · Sleep Medicine · doi:10.1016/j.sleep.2020.12.001 · Cited by 46
Roberts-Lewis, S. F., White, C. M., Ashworth, M. J., & Rose, M. R. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1983042 · Cited by 53
McKendry, J., Joanisse, S., Baig, S., Liu, B., Parise, G., Greig, C. A., & Breen, L. (2020) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glz142 · Cited by 44
Validity of energy expenditure estimation methods during 10 days of military training
Siddall, A. G., Powell, S. D., Needham‐Beck, S. C., Edwards, V. C., Thompson, J. E. S., Kefyalew, S. S., Singh, P., Orford, E. R., Venables, M., Jackson, S., et al. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13488 · Cited by 44
Routen, A. C., Upton, D., Edwards, M., & Peters, D. M. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.709266 · Cited by 50
Gilson, N. D., Ng, N., Pavey, T., Ryde, G. C., Straker, L. M., & Brown, W. J. (2016) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.01.009 · Cited by 43
Warner, L. M., Wolff, J. K., Ziegelmann, J. P., Schwarzer, R., & Wurm, S. (2016) · Psychology and Health · doi:10.1080/08870446.2016.1185523 · Cited by 44
“After this selection, data from seven consecutive days (day 3 to 9) were transformed into minutes of moderate and vigorous PA per week according to validated thresholds for older adults published by Esliger et al. (2011).”
MethodHayman, M., Reaburn, P. R. J., Browne, M., Vandelanotte, C., Alley, S., & Short, C. E. (2017) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-017-1277-9 · Cited by 51
“to classify activity into light, moderate and vigorous intensities [24].”
BackgroundMcDonald, S., Vieira, R., Godfrey, A., O’Brien, N., White, M., & Sniehotta, F. F. (2017) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0623-7 · Cited by 45
“PA data were interpreted based on cut-points which defined when the participant was performing PA of any intensity; ≥215 raw counts was used when the device was worn on the left (non-dominant) wrist and ≥385 raw counts was used for the right (dominant) wrist, based on a comparable association [29] to a wrist-worn devi…”
MethodWilliams, J., Stubbs, B., Richardson, S., Flower, C., Barr-Hamilton, L., Grey, B., Hubbard, K., Spaducci, G., Gaughran, F., & Craig, T. (2019) · BMC Psychiatry · doi:10.1186/s12888-019-2274-5 · Cited by 54
“99 METs), and vigorous (> 7+ METs) based on standardised algorithms with high sensitivity and specificity [22].”
BackgroundSedentary behaviour among elite professional footballers: health and performance implications
Weiler, R., Aggio, D., Hamer, M., Taylor, T., & Kumar, B. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000023 · Cited by 50
“We used previously defined cut-off points to calculate daily times in each activity intensity band.(24) Activity intensity was categorised as sedentary activity (<1.”
MethodHäusler, N., Marques-Vidal, P. M., Haba‐Rubio, J., & Heinzer, R. C. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.02.008 · Cited by 47
Fraysse, F., Grobler, A. C., Muller, J., Wake, M. A., & Olds, T. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-023194 · Cited by 48
Romeo, A., Edney, S. M., Plotnikoff, R. C., Olds, T., Vandelanotte, C., Ryan, J. C., Curtis, R., & Maher, C. A. (2021) · BMC Public Health · doi:10.1186/s12889-020-10100-0 · Cited by 48
“Accelerometer files were processed with 60 s epochs and the Esliger cutpoints [38] were used to define MVPA as any activity above 645 counts per minute.”
MethodAdelantado‐Renau, M., Beltran‐Valls, M. R., Migueles, J. H., Artero, E. G., Legaz‐Arrese, A., Capdevila‐Seder, A., & Moliner‐Urdiales, D. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12811 · Cited by 41
Segmenting accelerometer data from daily life with unsupervised machine learning
van Kuppevelt, D., Heywood, J., Hamer, M., Sabia, S., Fitzsimons, E., & van Hees, V. (2019) · PLOS ONE · doi:10.1371/journal.pone.0208692 · Cited by 41
Morgan, K., Rahman, M. A., Hill, R. A., Zhou, S., Bijlsma, G., Khanom, A., Lyons, R. A., & Brophy, S. T. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094532 · Cited by 51
Li, W., Kwok, C. C.-H., Chan, D. C.-W., Ho, A. W.-Y., Ho, C.-S., Zhang, J., Wing, Y. K., Wang, F., & Tse, L. A. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2018.11.022 · Cited by 40
Segmenting accelerometer data from daily life with unsupervised machine learning
van Kuppevelt, D., Heywood, J., Hamer, M., Sabia, S., Fitzsimons, E., & van Hees, V. (2018) · doi:10.1101/263046 · Cited by 41
Use of Accelerometry to Classify Activity Beneficial to Bone in Premenopausal Women
STILES, V. H., GRIEW, P. J., & ROWLANDS, A. V. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829ba765 · Cited by 36
Self-citationMooney, R., Quinlan, L. R., Corley, G. J., Godfrey, A., Osborough, C. D., & OLaighin, G. M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0170902 · Cited by 40
Price, E., Langford, J., Fawcett, T. W., Wilson, A. J., & Croft, D. P. (2022) · Applied Animal Behaviour Science · doi:10.1016/j.applanim.2022.105630 · Cited by 46
“GENEActiv accelerometers are wrist-worn devices designed to measure activity in humans (Esliger et al., 2011; Rowlands et al., 2014).”
Real-Time Personalized Monitoring to Estimate Occupational Heat Stress in Ambient Assisted Working
Pancardo, P., Acosta, F., Hernández-Nolasco, J. A., Wister, M. A., & López–de–Ipiña, D. (2015) · Sensors · doi:10.3390/s150716956 · Cited by 46
“The chosen value is mapped to METs using Equation (8) obtained in the calibration step of the smartphone’s accelerometer, and we map METs to the workload level in accordance with the proposal of [24].”
MethodResultInfluentialVroege, D. P., Wijsman, C. A., Broekhuizen, K., de Craen, A. J., van Heemst, D., van der Ouderaa, F. J., van Mechelen, W., Slagboom, P. E., Catt, M., Westendorp, R. G., et al. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.3643 · Cited by 39
“As a derivative outcome, we calculated the minutes per day spent in moderate-to-vigorous intensity physical activity from the wrist accelerometer, which has been validated against indirect calorimetry [18].”
Self-citationCostigan, S. A., Ridgers, N. D., Eather, N., Plotnikoff, R. C., Harris, N., & Lubans, D. R. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1356026 · Cited by 47
“Evidence of a difference in physical activity was observed; MPA and VPA were higher on the first HIIT intervention day, in comparison to a usual school day or PE day at baseline.”
BackgroundMethodInfluentialCompliance of Adolescent Girls to Repeated Deployments of Wrist-Worn Accelerometers
Rowlands, A. V., Harrington, D. M., Bodicoat, D. H., Davies, M. J., Sherar, L. B., Gorely, T., Khunti, K., & Edwardson, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001588 · Cited by 44
Self-citationPhysical activity, sleep, and fatigue in community dwelling Stroke Survivors
Shepherd, A. I., Pulsford, R. M., Poltawski, L., Förster, A., Taylor, R. S., Spencer, A. E., Hollands, L., James, M. A., Allison, R., Norris, M., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26279-7 · Cited by 41
FilterK: A new outlier detection method for k-means clustering of physical activity
Jones, P. J., James, M. K., Davies, M. J., Khunti, K., Catt, M., Yates, T. E., Rowlands, A. V., & Mirkes, E. M. (2020) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2020.103397 · Cited by 39
Self-citationSchilling, R., Schärli, E., Fischer, X., Donath, L., Faude, O., Brand, S., Pühse, U., Zahner, L., Rosenbaum, S., Ward, P. B., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203525 · Cited by 42
Hall, C. J. S., Eyre, E. L. J., Oxford, S. W., & Duncan, M. J. (2018) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk3040057 · Cited by 42
“Accelerometers were worn for 4 consecutive days on the child’s dominant hand [24] during all waking hours, except for water based activities to prevent skin irritation when drying.”
BackgroundMethodThe efficacy of morning versus evening exercise for weight loss: A randomized controlled trial
Brooker, P. G., Gomersall, S. R., King, N. A., & LEVERITT, M. D. (2022) · Obesity · doi:10.1002/oby.23605 · Cited by 45
“[30] were used to classify each 60-second epoch of waking wear time into one of four physical activity levels: sedentary, light, moderate, or vigorous.”
MethodJaremków, A., Markiewicz−Górka, I., Hajdusianek, W., Czerwińska, K., & Gać, P. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm13010050 · Cited by 37
“Time spent sleeping was deducted, and the collected data were grouped based on specific cut-off points [6].”
BackgroundMethodInfluentialDelextrat, A. A., Bateman, J., Esser, P., Targen, N., & Dawes, H. (2016) · Complementary Therapies in Medicine · doi:10.1016/j.ctim.2016.05.009 · Cited by 44
Horsch, A., Gilbert, L., Lanzi, S., Gross, J., Kayser, B., Vial, Y., Siméoni, U., Hans, D. B., Berney, A., Scholz, U., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020462 · Cited by 43
“Physical activity and fitness measures Physical activity (total physical activity and its intensity) is assessed using an accelerometer (GeneActiv) that is worn on the right wrist during 10 consecutive days.(169) The Chester Step Test, a multistage submaximal exercise test, is performed to estimate aerobic fitness (ma…”
MethodBuchan, D. S., McSeveney, F., & McLellan, G. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12538 · Cited by 42
“As these early wrist accelerometer calibration studies were undertaken using the GENEActiv accelerometer, however (Esliger et al., 2011; Zhang et al., 2012; Phillips et al., 2013), more recent studies using non-proprietary accelerations have suggested that activity estimates may not be equivalent between different bra…”
MethodCunningham-Sabo, L., Lohse, B., Smith, S., Browning, R., Strutz, E., Nigg, C., Balgopal, M., Kelly, K., & Ruder, E. (2016) · BMC Public Health · doi:10.1186/s12889-016-3118-6 · Cited by 36
“, Natick, MA) program and previously published cutpoints [60] are used to process the acceleration data and output minutes spent in activities of sedentary, light, moderate, and vigorous intensities for each day that the device was worn and for specific intervals of the day (i.”
MethodOrme, M. W., STEINER, M. C., Morgan, M. D., Kingsnorth, A. P., Esliger, D., Singh, S., & Sherar, L. B. (2019) · International Journal of COPD · doi:10.2147/copd.s183029 · Cited by 38
“5 metabolic equivalents (METs), while in a sitting, reclining, or lying posture,”(10) has been put forward as a potentially more achievable target for patients.(11) As time-based behaviors are inherently constrained by the 24-hour day, reducing time spent sedentary must result in spending more time in at least one oth…”
Self-citationStrączkiewicz, M., Glynn, N. W., & Harezlak, J. (2019) · Sensors · doi:10.3390/s19092095 · Cited by 42
“The preceding research on an older sample (mean age was approximately 49 years [25]) and a more exhaustive study on hand-dependent accelerations of AREA participants [26] suggest that the difference between hand use might be related to age, and therefore this requires further examination.”
BackgroundGough, C., Barr, C., Lewis, L. K., Hutchinson, C. L., Maeder, A., & George, S. (2023) · BMC Public Health · doi:10.1186/s12889-023-15093-0 · Cited by 37
“These devices have been deemed reliable and valid for classifying the intensity of PA in adults [28].”
BackgroundMethodKang, Y., O’Donnell, M. B., Strecher, V. J., & Falk, E. B. (2016) · Mindfulness · doi:10.1007/s12671-016-0608-7 · Cited by 39
“We collected accelerometer data throughout the entire 5-week duration of the study using a triaxial GENEA accelerometer (Esliger et al. 2011) worn on”
Sirichana, W., Dolezal, B. A., Neufeld, E. V., Wang, X., & Cooper, C. B. (2017) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2017.01.233 · Cited by 38
Gubelmann, C., Vollenweider, P., & Marques-Vidal, P. M. (2017) · Preventive Medicine · doi:10.1016/j.ypmed.2017.10.016 · Cited by 37
Kang, S. J., Leroux, A., Guo, W., Dey, D., Strippoli, M. F., Di, J., Vaucher, J., Marques-Vidal, P. M., Vollenweider, P., Preisig, M., et al. (2024) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2024.1321 · Cited by 35
Duncan, M. J., Rowlands, A. V., Lawson, C., Wright, S. L., Hill, M., Morris, M. G., Eyre, E. L. J., & Tallis, J. A. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1694078 · Cited by 36
“ROC curve analysis was conducted as described previously (Esliger et al., 2011) and cutpoints that maximised sensitivity (Se) and specificity (Sp) were derived (Perkins, and Schisterman 2006).”
MethodSelf-citationValidity and reliability of Nike + Fuelband for estimating physical activity energy expenditure
Tucker, W. J., Bhammar, D. M., Sawyer, B. J., Buman, M. P., & Gaesser, G. A. (2015) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-015-0008-7 · Cited by 34
“Wrist-worn accelerometers such as ActiWatch, GENEA, Vivago and Jawbone UP have also been shown to accurately predict EE during physical activity [13–16].”
MethodResultLitt, J., Alaimo, K., Buchenau, M., Villalobos, A., Glueck, D. H., Crume, T., Fahnestock, L., Hamman, R. F., Hébert, J. R., Hurley, T. G., et al. (2018) · Contemporary Clinical Trials · doi:10.1016/j.cct.2018.03.005 · Cited by 35
“Physical activity—Estimates of sedentary time and physical activity are measured objectively using thigh-mounted activPALTM accelerometers (PAL Technologies) [42,43], which has been validated for quantifying physical activity when worn on the thigh [44].”
MethodDobell, A., Eyre, E. L. J., Tallis, J. A., Chinapaw, M. J. M., Altenburg, T. M., & Duncan, M. J. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13496 · Cited by 39
Curtis, R., Olds, T., Plotnikoff, R. C., Vandelanotte, C., Edney, S. M., Ryan, J. C., & Maher, C. A. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-0896-4 · Cited by 34
Physical activity assessment by accelerometry in people with heart failure
Dibben, G. O., Gandhi, M. M., Taylor, R. S., Dalal, H. M., Metcalf, B. S., Doherty, P., Tang, L. H., Kelson, M. J., & Hillsdon, M. M. (2020) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-020-00196-7 · Cited by 36
“The GENEActiv accelerometer has been validated for both hip- and wrist-worn measurement of PA, and to distinguish between inactivity, light PA, and MVPA in healthy adults [22].”
BackgroundMethodRoughead, E. E., Pratt, N. L., Parfitt, G., Rowett, D. S., Ellett, L. M. K., Bereznicki, L., Merlin, T., Corlis, M. E., Kang, A. C., Whitehouse, J., et al. (2022) · Age and Ageing · doi:10.1093/ageing/afac092 · Cited by 35
“The GENEActiv is a research-grade activity tracker that allows highresolution data collection for up to 1 month [36, 37].”
Brooker, P. G., Gomersall, S. R., King, N. A., & LEVERITT, M. D. (2019) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2019.100320 · Cited by 34
“98) for both physical activity and sedentary behaviour [39,40].”
BackgroundPlasqui, G. (2017) · Obesity Reviews · doi:10.1111/obr.12506 · Cited by 32
Relationships between muscle size, strength, and physical activity in adults with muscular dystrophy
Jacques, M. F., Onambélé-Pearson, G. L., Reeves, N. D., Stebbings, G. K., Smith, J. A. B., & Morse, C. I. (2018) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.12347 · Cited by 35
Ecological momentary assessment of mood and physical activity in people with depression
Hollands, L., Lambert, J. D., Price, L., Powell, D., & Greaves, C. J. (2020) · Journal of Affective Disorders · doi:10.1016/j.jad.2020.03.085 · Cited by 33
Pfeiffer, K. A., Clevenger, K. A., Kaplan, A. S., Camp, C. A. V., Strath, S. J., & Montoye, A. H. K. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac89ca · Cited by 32
Self-supervised Learning for Accelerometer-based Human Activity Recognition: A Survey
Logacjov, A. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3699767 · Cited by 41
Measuring the Exercise Component of Energy Availability during Arduous Training in Women.
Gifford, R., Greeves, J., Wardle, S., O'Leary, T., Double, R. L., Venables, M., Boos, C., Langford, J., Woods, D., & Reynolds, R. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002527 · Cited by 25
UK university staff experience high levels of sedentary behaviour during work and leisure time
Faghy, M. A., Duncan, M. J., Pringle, A., Meharry, J. B., & Roscoe, C. M. P. (2021) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2021.1874704 · Cited by 35
“The GENEActiv is a lightweight triaxial accelerometer which provides raw acceleration data and has previously been described in detail [22].”
MethodResultHall, C. J. S., Eyre, E. L. J., Oxford, S. W., & Duncan, M. J. (2019) · Sports · doi:10.3390/sports7040077 · Cited by 32
“Physical activity (PA) was assessed over four consecutive days, including two weekend days, using wrist-worn triaxial accelerometery (GENEActiv, Activeinsights, Cambridge, UK) [29–31] on the child’s dominant wrist [31,32].”
MethodMontoye, A. H. K., Conger, S. A., Connolly, C. P., Imboden, M. T., Nelson, M. B., Bock, J. M., & Kaminsky, L. A. (2017) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2017.1337638 · Cited by 33
“left) may affect MVPA estimates, which coincides with our finding of differences in estimates of time spent in MVPA compared to the criterion measure (left wrist-worn accelerometer more accurate with V1V2/V2 training method, right wrist-worn accelerometermore accurate with V2/V2 training method) (Esliger et al., 2011;…”
ResultHoffman, C. L., Browne, M., & Smith, B. P. (2020) · Animals · doi:10.3390/ani10020278 · Cited by 34
“5 METs) threshold that divides sedentary activities from light physical activities, such as standing or walking slowly [33].”
BackgroundRößler, R., Bridenbaugh, S. A., Engelter, S. T., Weibel, R., Infanger, D., Giannouli, E., Sofios, A., Iendra, L., Portegijs, E., Rantanen, T., et al. (2020) · BMC Neurology · doi:10.1186/s12883-020-01920-z · Cited by 35
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.