Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 401–500 of 650
Replacement of Sedentary Time with Physical Activity: Effect on Lipoproteins
Phillips, C. M., Dillon, C. B., & Perry, I. J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001511 · Cited by 9
Hamid, A., Duncan, M. J., Eyre, E. L. J., & Jing, Y. (2020) · European Journal of Sport Science · doi:10.1080/17461391.2020.1789749 · Cited by 8
“9), the raw 80Hz triaxial GENEActiv data were saved in raw format as binary files and then data for each wear location were summed into a signal magnitude vector (gravity subtracted) expressed in 1s epochs, as is conventional (Esliger et al., 2011; Phillips et al., 2013).”
MethodPrasad, S., Ramanan, D., Bennani, H., Paulin, M. G., Cannon, R. D., Palla, S., & Farella, M. (2021) · Clinical Oral Investigations · doi:10.1007/s00784-021-03816-9 · Cited by 11
García‐Alonso, Y., García‐Hermoso, A., Izquierdo, M., Legarra‐Gorgoñon, G., Ramírez‐Vélez, R., & Alonso-Martínez, A. M. (2022) · Pediatric Obesity · doi:10.1111/ijpo.12923 · Cited by 7
Frailty trajectory over one year among residential aged care (nursing home) residents
Lim, R., Kelly, T., Andrade, A. Q. D., Ellett, L. M. K., Bilton, R. L., Dorj, G., Pratt, N. L., & Roughead, E. E. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.1010444 · Cited by 7
Ezekiel, L., Veiga, J. J. D., Ward, T. E., Dawes, H., & Collett, J. (2023) · British Journal of Occupational Therapy · doi:10.1177/03080226231183293 · Cited by 7
“The programme then calculated whether periods were spent in sedentary, light, moderate and vigorous activity by applying ‘cut-points’ that correspond to different intensities of activities (Esliger et al., 2011).”
MethodPersonalizing Physical Effort Estimation in Workplaces Using a Wearable Heart Rate Sensor
Pancardo, P., Hernández-Nolasco, J. A., Acosta, F., & Wister, M. A. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-48799-1_14 · Cited by 9
Lin, H., Hartley, P., Forsyth, F., Pilling, M. A., Hobbs, R. F., Taylor, C. J., Schiff, R., & Deaton, C. (2021) · European Journal of Cardiovascular Nursing · doi:10.1093/eurjcn/zvab028 · Cited by 8
Salagaras, B. S., MacKenzie‐Shalders, K. L., Slater, G., McLellan, C., & Coffey, V. G. (2021) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2021-0316 · Cited by 9
Variations and Patterns in Sleep: A Feasibility Study of Young Carers in Families with ALS
Kavanaugh, M. S., Johnson, K. T., & Zawadzki, M. J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10194482 · Cited by 7
Collecting a comprehensive evidence base to monitor fracture rehabilitation: A case study
Callary, S. A. (2013) · World Journal of Orthopedics · doi:10.5312/wjo.v4.i4.259 · Cited by 7
Physical Activity Assessment in Wheelchair Users
Conger, S. A. (2011) · Cited by 6
Broatch, J. R., Zarekookandeh, N., Glarin, R. K., Strik, M., Johnston, L. A., Moffat, B. A., Bird, L., Gunningham, K., Churilov, L. P., Johns, H. T., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-069413 · Cited by 6
Time use and dimensions of healthy sleep: A cross-sectional study of Australian children and adults
Matricciani, L., Dumuid, D., Stanford, T., Maher, C. A., Bennett, P. N., Bobrovskaya, L., Murphy, A. W., & Olds, T. (2024) · Sleep Health · doi:10.1016/j.sleh.2023.10.012 · Cited by 7
Shepherd, A. I., James, T. J., Gould, A. A. M., Mayes, H. S., Neal, R., Shute, J. K., Tipton, M., Massey, H. C., SAYNOR, Z. L., Perissiou, M., et al. (2024) · The Journal of Physiology · doi:10.1113/jp285322 · Cited by 7
“The GENEActiv monitor has been shown valid and reliable in measuring sleep (Van Hees et al., 2015), physical activity (Eslinger et al., 2011) and sedentary time (Pavey et al., 2016) in adults.”
Solera-Sanchez, A., Beltran‐Valls, M. R., Moliner‐Urdiales, D., & Adelantado‐Renau, M. (2024) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2024.07.001 · Cited by 6
“This device provides a reliable (coefficient of variation intra-and inter-instrument of 1.4 % and 2.1 %, respectively) 33 and valid assessment of physical activity in young people ( r = 0.93, p = 0.001).”
MethodInfluentialMeasuring 24‐h use of time in people with a diabetes‐related foot ulcer: A feasibility study
Murphy, A., Graham, K., Olds, T., Loughry, C., Fraysse, F., Dumuid, D., Stanford, T., & Matricciani, L. (2024) · Journal of Foot and Ankle Research · doi:10.1002/jfa2.12045 · Cited by 7
“…gold standard to measure 24 ‐ h use of time, the GENEActiv (Activinsights, UK) has previously been used in population ‐ based studies [34] and has demonstrated excellent technical validity and reliability for classifying different intensities of PA [35, 36] and sleep duration [37] in adults.”
Pabla, P., Mallinson, J. E., Nixon, A., Keeton, M., Cooper, S., Marshall, M. J., Jacques, M. F., Brown, S. A., Johansen, O. E., Cuenoud, B. M., et al. (2024) · American Journal of Clinical Nutrition · doi:10.1016/j.ajcnut.2024.12.022 · Cited by 6
“2 and analyzed using an open access macro [15], which assesses physical activity patterns (sedentary, light, moderate, and vigorous activities in min) using cut-points established by Esliger et al. [16].”
Caudroit, J., Lapointe, J., Comtois, A. S., Romain, A. J., & Bernard, P. (2025) · Disability and Rehabilitation · doi:10.1080/09638288.2025.2488041 · Cited by 6
“PA data were analysed with a tau-u, a non-parametric test providing effect size estimates [45]. the tau-u coefficient was calculated for each participant and PA variables (i.e., daily total of PA, daily time spent in moderate to vigorous PA).”
Validity Evidences and Validation Procedures of Objective Physical Activity Measures
이미영 (2011) · The Korean Journal of Measurement and Evaluation in Physical Education and Sports Science · doi:10.21797/ksme.2011.13.2.002 · Cited by 6
Salvador-García, C., Chiva-Bartoll, Ò., & Diago, C. C. (2020) · Cultura Ciencia y Deporte · doi:10.12800/ccd.v15i43.1407 · Cited by 6
Carr, R. M., Quested, E., Stenling, A., Thøgersen‐Ntoumani, C., Prestwich, A., Gucciardi, D. F., McVeigh, J. A., & Ntoumanis, N. (2021) · Health Psychology and Behavioral Medicine · doi:10.1080/21642850.2021.1902815 · Cited by 6
“Esliger et al.’s (2011) criteria determined classifications into sedentary, light, moderate,”
BackgroundValidity and Test-Retest Reliability of a Thai Stroke Physical Activity Questionnaire
Potchana, K., Saengsuwan, J., & Kittipanya‐ngam, P. (2021) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2021.105907 · Cited by 6
Martín‐Martín, J., Wang, L., De-Torres, I., Escriche-Escuder, A., González‐Sánchez, M., Muro-Culebras, A., Roldán‐Jiménez, C., Ruiz‐Muñoz, M., Mayoral, F., Biró, A., et al. (2022) · Sensors · doi:10.3390/s22072552 · Cited by 6
Measurement of Sedentary Behaviour in Population Studies
Ainsworth, B. E., Rivière, F., & Flórez-Pregonero, A. (2017) · Springer series on epidemiology and public health · doi:10.1007/978-3-319-61552-3_2 · Cited by 6
O’Brien, C. M., Duda, J. L., Kitas, G. D., Zanten, J. V., Metsios, G. S., & Fenton, S. A. M. (2019) · PubMed Central · doi:10.31138/mjr.30.2.125 · Cited by 7
Tarca, B. D., Jesudason, S., Leu, R. K. L., Ovenden, M., Borlace, M., Meade, A., Bennett, P. N., Wycherley, T. P., Boyle, T., & Ferrar, K. (2021) · Peritoneal Dialysis International · doi:10.1177/0896860821992243 · Cited by 6
“Physical activity intensity thresholds established by Esliger et al.(15) are then automatically applied to the now established period of active wear time to produce minutes of sedentary time, low, moderate and vigorous activity.”
MethodThe relationship between activity level and cognitive function in Chinese community-dwelling elderly
Liu, M.-L., Jiang, L., Wang, W., Zhang, X., Xing, X.-H., Deng, W., & Li, T. (2021) · Research in Sports Medicine · doi:10.1080/15438627.2021.1888096 · Cited by 6
“Recording and evaluation of activity levels According to previous international studies (Esliger et al., 2011; Lim et al., 2018; Menai et al., 2017b), portable accelerometer (GENEActiv Original; Activinsights Ltd, Kimbolton, Cambs, UK, http://www.geneactiv.org) was used to objectively record daily…”
MethodComparing Five Generations of ActiGraph Devices Using an Orbital Shaker
LaMunion, S. R., NGUYEN, J., Brychta, R. J., Troiano, R. P., Friedl, K. E., & Chen, K. Y. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003652 · Cited by 5
Miatke, A., Olds, T., Maher, C. A., Fraysse, F., & Dumuid, D. (2025) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-025-00082-y · Cited by 5
Lund, K., Larsen, M. D., Knudsen, T., Kjeldsen, J., Nielsen, R. G., Brage, S., & Nørgård, B. M. (2022) · BMC Gastroenterology · doi:10.1186/s12876-022-02358-y · Cited by 5
“movement volume (ENMO) and intensity levels [20, 22, 28, 39].”
Andrade, A. Q. D., Lim, R., Kelly, T., Parfitt, G., Pratt, N. L., & Roughead, E. E. (2022) · Journal of the American Geriatrics Society · doi:10.1111/jgs.18181 · Cited by 6
Lin, W., Karahanoğlu, F. I., Demanuele, C., Khan, S., Cai, X., Santamaria, M., Di, J., & Adamowicz, L. (2023) · Frontiers in Digital Health · doi:10.3389/fdgth.2023.1321086 · Cited by 5
“While there is much research surrounding the appropriate cut-points to use to segment activity levels (33, 11, 10, 12 – 15), there has also been some research on moving away from cut-points and time spent in various activity levels.”
Deep behavioural representation learning reveals risk profiles for malignant ventricular arrhythmias
Kolk, M. Z. H., Frodi, D. M., Langford, J., Andersen, T. O., Jacobsen, P. K., Risum, N., Tan, H. L., Svendsen, J. H., Knops, R. E., Diederichsen, S. Z., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01247-w · Cited by 5
“Continuous raw data were recorded at 50 Hz or 20 Hz and converted into daily summaries 22,23 .”
MethodParfitt, G., Post, D., Ellett, L. M. K., Lim, R., Penington, A., Corlis, M. E., & Roughead, E. E. (2020) · PeerJ · doi:10.7717/peerj.9605 · Cited by 5
Wilson, C. E., Nichles, A., Zmicerevska, N., Carpenter, J. S., Song, Y. J. C., McHugh, C. M., Hamilton, B. A., Hockey, S. J., Scott, E. M., & Hickie, I. B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044977 · Cited by 6
Najafi, A., Safari‐Faramani, R., Selk-Ghaffari, M., Najafi, F., Ghafouri, M., Darbandi, M., Mahdaviani, B., & Nakhostin-Ansari, A. (2023) · BMC Public Health · doi:10.1186/s12889-023-16895-y · Cited by 7
“…with moderate and vigorous intensities (4 METs ≤ ), including light technical jobs, masonry, light agricultural jobs, aerobic exercise, carrying light objects, heavy engineering jobs, heavy labor jobs, and heavy exercise in calculating physical activity levels for each participant [20, 21].”
BackgroundOutputs Available from Objective Monitors
Tudor‐Locke, C. (2016) · Springer series on epidemiology and public health · doi:10.1007/978-3-319-29577-0_3 · Cited by 5
Moores, C. J., Maeder, A., Miller, J. M., Prichard, I. J., Lewis, L. K., Bell, L., Macoustra, A., & Miller, M. (2019) · JMIR Research Protocols · doi:10.2196/13340 · Cited by 5
“Change from preprogram (enrollment) to postprogram (immediately after a 14-week intervention) 7-day 24-hour accelerometry, GENEActiv wrist-worn accelerometer [46] on nondominant hand [47] and Adolescent Sedentary Activity Questionnaire [49] Adolescent sedentary behavior”
BackgroundMethodTitze, S., Ruf, W., Lackinger, C., Großschädl, L., Strehn, A., Dorner, T. E., & Niebauer, J. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16132362 · Cited by 6
“[13]: light intensity = 217 to 644, moderate intensity = 645 to 1810, and vigorous intensity ≥ 1811 SVMgs.”
BackgroundJolly, K. B., Griffin, T. L., Sidhu, M. S., Adab, P., Burgess, A., Collins, C. E., Daley, A., Entwistle, A., Frew, E. J., Hardy, P., et al. (2020) · Public Health Research · doi:10.3310/phr08020 · Cited by 5
Evaluation of an implementation project: The exercise physiology in aged care program
Parfitt, G., Post, D., Penington, A., Davison, K., & Corlis, M. E. (2020) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.13923 · Cited by 5
McCarthy, K. L., Harris‐Brown, T., Smits, E. J., Legg, A., Chatfield, M. D., & Paterson, D. L. (2021) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-021-04294-3 · Cited by 5
“The cut-points utilised for the GENEActivTMmacro reports were not used for this study as they were derived from a wrist-worn device in a healthy adult population [16].”
MethodCarpenter, J. S., Zmicerevska, N., Crouse, J. J., Nichles, A., Garland, A., Song, Y. J. C., Wilson, C. E., Rohleder, C., McHugh, C. M., Leweke, F. M., et al. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-056298 · Cited by 5
Caudroit, J., Lapointe, J., Comtois, Romain, A. J., & Bernard, P. (2024) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/zyh36 · Cited by 5
Muñoz‐Pardeza, J., López‐Gil, J. F., Hormazábal‐Aguayo, I., Huerta‐Uribe, N., Ezzatvar, Y., & García‐Hermoso, A. (2025) · Diabetologia · doi:10.1007/s00125-025-06496-2 · Cited by 5
Suarez, J. R., Park, J., Lafontant, K., & Thiamwong, L. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2025-0032 · Cited by 5
Vuletić, P. R., Gilić, B., Pavlinović, V., Matijašević, P., & Sekulić, D. (2026) · Sports · doi:10.3390/sports14020077 · Cited by 5
“The GENEActiv accelerometer is widely validated and commonly used for the assessment of physical activity, sedentary behavior, and sleep patterns in both research and clinical settings [48,49].”
Lewis, A. P., Turner, L., Fryer, S. M., Smith, R., Dillarstone, H., Patrick, Y., & Bevan-Smith, E. (2024) · Chronic Respiratory Disease · doi:10.1177/14799731241238435 · Cited by 6
“33 The GENEActive was con fi gured to record at a sampling frequency of 50 Hz, with fi les extracted using the GE-NEActivee software (version 3.3).”
MethodInfluentialTurner, W., Brühl, A. B., Böker, H., Schulze, B., Marschall, K., Marca, R. L., Pfaff, M., Russmann, T., & Schmidt‐Trucksäss, A. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081299 · Cited by 4
Matthews, C. E., Saint‐Maurice, P. F., Freeman, J. R., Hayes, H. A., Shreves, A. H., Doherty, A., Hyde, E. T., Ylarregui, K., Jones, R. R., & Keadle, S. K. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0051 · Cited by 7
Hillsdon, M. M., Schoenfelder, A., Metcalf, B. S., Stathi, A., Western, M. J., & Langford, J. (2025) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-025-01797-6 · Cited by 5
“The GENEActiv accelerometer has demonstrated excellent intra-device and inter-device reliability in measuring acceleration [14].”
Methods to assess measurement error in questionnaires of sedentary behavior
Sampson, J. N., Matthews, C. E., Freedman, L. S., Carroll, R. J., & Kipnis, V. (2016) · Journal of Applied Statistics · doi:10.1080/02664763.2015.1117593 · Cited by 4
“As many large studies cannot afford to distribute devices such as the activPal [7] or accelerometer [8] to all participants, there is a need to determine whether previous day recalls (PDRs) [23], or questionnaires inquiring about an individual’s activity over the past 24 h, can accurately measure sedentary time.”
Wang, Y., Wattelez, G., Frayon, S., Caillaud, C., Galy, O., & Yacef, K. (2022) · ACM Transactions on Computing for Healthcare · doi:10.1145/3561611 · Cited by 4
“As a irst step, we use gravity-subtracted Signal Vector Magnitudes (SVMgs) [21] to aggregate acceleration readings from the x, y, and z axes over a speciied epoch into the magnitude of motion.”
MethodHe, Z., Sun, Y., Huang, H., Wellens, J., Liu, Y., Dan, L., Ruan, X., Fu, T., Li, Z., Wang, X., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000003255 · Cited by 4
“The Axivity AX3 device has been validated in a previous study using multi-axis shaking tests and showed equivalent output to GENEActive accelerometer [21] , which has been validated in both laboratory and free-living assessments [ 22 , 23 ] .”
Cohort Profile: Growing Up in Wales: The Environments for Healthy Living study
Morgan, K., Khanom, A., Hill, R. A., Lyons, R. A., & Brophy, S. T. (2015) · International Journal of Epidemiology · doi:10.1093/ije/dyv178 · Cited by 4
Flórez-Pregonero, A., Buman, M. P., & Ainsworth, B. E. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0022 · Cited by 4
Wilson, C. E., Carpenter, J. S., Nichles, A., Zmicerevska, N., Song, Y. J. C., McHugh, C. M., Hamilton, B. A., Hockey, S. J., Crouse, J. J., Koethe, D., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-064682 · Cited by 5
Taylor, A. H., Thompson, T., Streeter, A., Chynoweth, J., Snowsill, T., Ingram, W. M., USSHER, M. H., Aveyard, P. N., Murray, R. L., Harris, T. J., et al. (2023) · Health Technology Assessment · doi:10.3310/kltg1447 · Cited by 6
Lock, M., Post, D., Dollman, J., & Parfitt, G. (2023) · Health Promotion Journal of Australia · doi:10.1002/hpja.740 · Cited by 4
Tommasini, F., Marques-Vidal, P. M., Kayser, B., Tasheva, P., Paraschiv-Ionescu, A., & Méan, M. (2022) · Swiss Medical Weekly · doi:10.57187/smw.2022.40012 · Cited by 4
“These accelerometers provide a reliable and valid measurement of physical activity in adults [24] and were proven to be equivalent to similar devices [25, 26].”
MethodOral ribose supplementation in dystroglycanopathy: A single case study
Thewissen, R., Post, M. A., Maas, D. M., Veizaj, R., Wagenaar, I., Alsady, M., Kools, J., Bouman, K., Zweers, H. E. E., Meregalli, P. G., et al. (2024) · JIMD Reports · doi:10.1002/jmd2.12394 · Cited by 6
Physical activity trajectories and incidence of cardiovascular risk factors: a prospective study
Naoum, N., & Marques-Vidal, P. M. (2025) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2025.104201 · Cited by 3
Wagnild, J. M., Bayliss, C. R., Maier, R. H., Ogundimu, E. O., Zacharias, J., & Akowuah, E. (2025) · Circulation · doi:10.1161/circulationaha.125.074651 · Cited by 4
Akowuah, E., Maier, R. H., Hancock, H. C., Wagnild, J. M., Vale, L. D., Fernandez-García, C., Kharatikoopaei, E., Ogundimu, E. O., Mathias, A., Walmsley, Z., et al. (2025) · Health Technology Assessment · doi:10.3310/pkot2391 · Cited by 3
Objective and Subjective Physical Activity Levels in Austrian Middle School Students
Greier, C., Drenowatz, C. J., Riechelmann, H., & Greier, K. (2021) · Advances in Physical Education · doi:10.4236/ape.2021.114037 · Cited by 3
“The device has been shown to provide valid and reliable information (Esliger et al., 2011; Pavey et al., 2016).”
Measurement of Sedentary Behaviour in Population Studies
Ainsworth, B. E., Rivière, F., & Flórez-Pregonero, A. (2023) · Springer series on epidemiology and public health · doi:10.1007/978-3-031-41881-5_3 · Cited by 3
de Laat, E. C. M., Opstal, S. L. S. H.-V., Bouman, K., van Doorn, J. L. M., Cameron, D., van Alfen, N., Dittrich, A. T. M., Kamsteeg, E., Smeets, H. J. M., Groothuis, J. T., et al. (2024) · BMC Neurology · doi:10.1186/s12883-024-03852-4 · Cited by 4
Clevenger, K. A., McNarry, M. A., Mackintosh, K. A., Pfeiffer, K. A., Nelson, B. A., Bock, J. M., Imboden, M. T., Kaminsky, L. A., & Montoye, A. H. K. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0013 · Cited by 3
Tempest, G. D., Eston, R. G., & Parfitt, G. (2016) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12365 · Cited by 3
“A triaxial accelerometer (GENEA, Unilever Discover, Sharnbrook, UK; for reliability and validity see Esliger et al., 2011) was used to measure head acceleration (X, Y, Z directions, sample rate 50 Hz) stored in g units during exercise.”
MethodSelf-citationClassification of physical activities and sedentary behavior using raw data of 3D hip acceleration
Tjurin, P., Niemelä, M., Huusko, M., Ahola, R., Kangas, M., & Jämsä, T. J. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_218 · Cited by 4
“4- and 7-MET thresholds to differentiate moderate-intensity PA [21].”
BackgroundTwaites, J., Everson, R., Langford, J., & Hillsdon, M. M. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0006 · Cited by 3
Plekhanova, T., Rowlands, A. V., Davies, M. J., Edwardson, C. L., Hall, A. P., & Yates, T. E. (2020) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2020-0361 · Cited by 3
Self-citationAccelerometry as an objective measure of upper-extremity activity
Larrivée, S., Avery, E., Leiter, J., & Old, J. (2021) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02293-8 · Cited by 3
Shrestha, N., Parker, A. G., Jurakić, D., Biddle, S., & Pedišić, Ž. (2021) · Issues in Mental Health Nursing · doi:10.1080/01612840.2021.1972189 · Cited by 3
“A relatively high validity has been found for GENEActiv accelerometer data as assessed against indirect calorimetry (Esliger et al., 2011).”
BackgroundLiechti, F. D., Heinzmann, J., Leuenberger, J. M. S., Limacher, A., Wertli, M. M., & Verra, M. L. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-058509 · Cited by 3
McDevitt, B., Connolly, J., Duddy, D., Doherty, R., & Condell, J. V. (2022) · Irish Signals and Systems Conference · doi:10.1109/issc55427.2022.9826199 · Cited by 4
Riedel, D., Lorke, N., Mierau, A., Strüder, H. K., Wolf, D. G. F., Fischer, F. U., Fellgiebel, A., Tüscher, O., Kollmann, B., & Knaepen, K. (2023) · Experimental Gerontology · doi:10.1016/j.exger.2023.112167 · Cited by 4
Ma, T., Sirard, J. R., & Jennings, L. (2023) · Journal of Physical Activity and Health · doi:10.1123/jpah.2022-0505 · Cited by 3
Firkin, C. J., Obrusníková, I., & Koch, L. C. (2024) · Healthcare · doi:10.3390/healthcare12191912 · Cited by 3
“Since 1998, additional cut-point parameters have been established, including Esliger 2011 classifications using raw acceleration data [32].”
BackgroundLiechti, F. D., Heinzmann, J., Schmutz, N. A., Rossen, M. L., Rossel, J., Limacher, A., Leuenberger, J. M. S., Baumgartner, C., Wertli, M. M., Aujesky, D., et al. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-086921 · Cited by 4
Kang, S. J., Guo, W., Zipunnikov, V. M., Glaus, J., Lamers, F., Strippoli, M. F., Marques-Vidal, P. M., Vaucher, J., Harpe, R. D. L., Vollenweider, P., et al. (2025) · Journal of Affective Disorders · doi:10.1016/j.jad.2025.02.065 · Cited by 3
Vinyasa Flow: Metabolic Cost and Validation of Hip- and Wrist-Worn Wearable Sensors
Huberty, J., Matthews, J. L., Toledo, M. J. L., Smith, L., Jarrett, C. L., Duncan, B., & Buman, M. P. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2017-0010 · Cited by 3
Edney, S. M., Olds, T., Ryan, J. C., Plotnikoff, R. C., Vandelanotte, C., Curtis, R., & Maher, C. A. (2019) · Journal of Physical Activity and Health · doi:10.1123/jpah.2018-0585 · Cited by 3
Motor and cognitive function according to level of physical activity in stroke patients
Kim, J. J., & Lee, J. W. (2023) · The Journal of Korean Academy of Physical Therapy Science · doi:10.26862/jkpts.2023.12.30.4.29 · Cited by 2
Shifflett, S., Parada, H., & Crespo, N. C. (2025) · Journal of Immigrant and Minority Health · doi:10.1007/s10903-025-01683-0 · Cited by 2
“Accelerometer data were downloaded and processed using age-specific recommended child PA cut points (sedentary time: 1.5 METS or physically active: ≥ 1.6 METS) [41] and adult PA cut points (sedentary time: 1.5 METS or physically active: ≥ 1.6 METS) [40].”
InfluentialDaily Variability in Sedentary Behaviour and Physical Activity Responsiveness in Older Women
Grant, D. M., Tomlinson, D. J., Tsintzas, K., & Onambélé-Pearson, G. L. (2025) · Sensors · doi:10.3390/s25072194 · Cited by 3
“The GENEActiv has previously been validated for objective measures of free-living physical behaviour [44–46].”
Continuity and Change of Delayed Sleep Phase From Adolescence to Early Adulthood
Jääkallio, P., Kuula, L., Partonen, T., & Pesonen, A. (2025) · PEDIATRICS · doi:10.1542/peds.2025-071832 · Cited by 2
Cui, Y., Liu, Y., Kwan, M., & Zheng, L. (2026) · Environmental Research · doi:10.1016/j.envres.2026.124443 · Cited by 3
Chanteau, A., Faity, G. V., Mahé, G., Sabia, S., & Faucheur, A. L. (2026) · Sports Medicine - Open · doi:10.1186/s40798-026-01039-4 · Cited by 2
Welch, W. A. (2012) · Cited by 2
Twaites, J., Everson, R., Langford, J., & Hillsdon, M. M. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0058 · Cited by 2
Vallarta‐Robledo, J. R., Joost, S., Ruas, M. A. V., Gubelmann, C., Vollenweider, P., Marques-Vidal, P. M., & Guessous, I. (2022) · PLoS ONE · doi:10.1371/journal.pone.0252255 · Cited by 2
“7 1-minute epoch files using the GENEActiv macros [29].”
MethodTraore, I., Megdiche, I., Marquet-Doléac, J., & Chaâri, L. (2023) · IEEE/ACS International Conference on Computer Systems and Applications (AICCSA) · doi:10.1109/aiccsa59173.2023.10479317 · Cited by 2
Hauser, R., Harpe, R. D. L., Vollenweider, P., Hullin, R., Vaucher, J., Marques-Vidal, P. M., & Méan, M. (2024) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2024.102743 · Cited by 3
“(White et al., 2016 Dec 9; Esliger et al., 2011 Jun) The accelerometers, pre-programmed with a 50 Hz sampling frequency, were attached to the participants ’ right wrist.”
BackgroundInfluentialMuñoz‐Pardeza, J., Gracia‐Marco, L., López‐Gil, J. F., Hormazábal‐Aguayo, I., Huerta‐Uribe, N., Mármol-Pérez, A., Ezzatvar, Y., Izquierdo, M., & García‐Hermoso, A. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf328 · Cited by 3
Dominick, G. M., Winfree, K. N., Pohlig, R. T., & Papas, M. A. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7413 · Cited by 2
“Indeed, research has recently begun to utilize raw acceleration signals for developing improved algorithms for hip and wrist-worn accelerometers [5-7] that also include ActiGraph”
Carter, S., Hill, A. M., Yandell, C. A., Buckley, J. D., & Coates, A. M. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081664 · Cited by 2
Suárez-Alcázar, M. P., Collado‐Boira, E., Recacha-Ponce, P., Salas‐Medina, P., Garcia-Roca, M. E., Domingo, C. H., Muriach, M., Baliño, P., Buils, R. F., Latorre, M. L. M., et al. (2024) · Healthcare · doi:10.3390/healthcare12141423 · Cited by 2
Schwendinger, F., Wagner, J., Knaier, R., Infanger, D., Rowlands, A. V., Hinrichs, T., & Schmidt‐Trucksäss, A. (2023) · medRxiv · doi:10.1101/2023.04.19.23288786 · Cited by 2
Self-citation
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.