Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Cited by
Items 301–400 of 650
Keane, E., Kearney, P. M., Perry, I. J., Browne, G. M., & Harrington, J. M. (2014) · JMIR Research Protocols · doi:10.2196/resprot.3140 · Cited by 21
“Free living physical activity was measured over a consecutive 7 day period using a validated tri-axial GENEActiv accelerometer [58,59].”
Gubelmann, C., Kuehner, C., Vollenweider, P., & Marques-Vidal, P. M. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3881-4 · Cited by 18
Gubelmann, C., Antiochos, P., Vollenweider, P., & Marques-Vidal, P. M. (2018) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2018.05.012 · Cited by 16
“This device has been validated against reference methods (Esliger et al., 2011).”
BackgroundMethodResultAlzahrani, H. A., Mackey, M., Stamatakis, E., & Shirley, D. (2021) · PLoS ONE · doi:10.1371/journal.pone.0256459 · Cited by 18
Physical Activity Epidemiology
Weber, A., Schmid, D., & Leitzmann, M. F. (2023) · Springer eBooks · doi:10.1007/978-1-4614-6625-3_67-1 · Cited by 16
Ziebart, C., Giangregorio, L., Gibbs, J. C., Levine, I. C., Tung, J. Y., & Laing, A. C. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.04.022 · Cited by 16
Harrington, J. M., Perry, C., Keane, E., & Perry, I. J. (2020) · Public Health Nutrition · doi:10.1017/s1368980020000014 · Cited by 15
“days using a wrist-worn validated tri-axial Geneactiv accelerometer(24,25).”
MethodCancer survivors exercise at higher intensity in outdoor settings: The GECCOS trial
Miller, J. M., Sadak, K. T., Shahriar, A. A., Wilson, N., Hampton, M., Bhattacharya, M., Towle, A., & Turcotte, L. M. (2020) · Pediatric Blood & Cancer · doi:10.1002/pbc.28850 · Cited by 15
Assessing Neurobehavioral Alterations Among E-waste Recycling Workers in Hong Kong
Liao, G., Wang, F., Lu, S., Yu, Y. H. K., Arrandale, V. H., Chan, A. H. S., & Tse, L. A. (2023) · Safety and Health at Work · doi:10.1016/j.shaw.2023.12.004 · Cited by 14
“One possible explanation could be the dismantling/repairing job designation was highly physically demanding, even for those manually handling e-waste in a sitting position, which would be captured by our sensitive wrist-worn accelerometer [31].”
BackgroundPhysical activity and lung function association in a healthy community-dwelling European population
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · BMC Pulmonary Medicine · doi:10.1186/s12890-024-02979-x · Cited by 15
“The waist location has indeed been shown to have better accuracy, followed by the left and then the right wrist, which was used in our study [33].”
BackgroundMethodBabic, M., Morgan, P. J., Plotnikoff, R. C., Lonsdale, C., Eather, N., Skinner, G., Baker, A., Pollock, E. R., & Lubans, D. R. (2014) · Contemporary Clinical Trials · doi:10.1016/j.cct.2014.12.001 · Cited by 16
“GENEActiv wrist-worn accelerometers have displayed acceptable intra- and inter-instrumental reliability and provide a valid and reliable estimate of physical activity in young people [47,48].”
BackgroundMethodThe Use of Frailty Scoring to Predict Early Physical Activity Levels After Cardiac Surgery
Abdullahi, Y. S., Salmasi, M. Y., Moscarelli, M., Parlanti, A., Marotta, M., Varone, E., Solinas, M., Malik‐Sheriff, R. S., Casula, R., & Athanasiou, T. (2020) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2020.06.029 · Cited by 15
Bahl, J. S., Millar, S. C., Fraysse, F., Arnold, J. B., Taylor, M., Callary, S. A., Solomon, L. B., & Thewlis, D. (2021) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.20.01679 · Cited by 15
“During waking wear time, activity levels were classified according to Esliger et al.24.”
MethodFaghy, M. A., Armstrong-Booth, K. E., Staples, V., Duncan, M. J., & Roscoe, C. M. P. (2021) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk6030056 · Cited by 17
“The GENEActiv is a lightweight triaxial accelerometer that provides raw acceleration data and has previously been described in detail [21].”
BackgroundMethodDorj, G., Nair, N. P., Bereznicki, L., Kelly, T., Pratt, N. L., Ellett, L. M. K., Andrade, A. Q. D., Rowett, D. S., Whitehouse, J., Widagdo, I. S., et al. (2022) · Drugs & Aging · doi:10.1007/s40266-022-00983-6 · Cited by 15
“Longitudinal measurements pertaining to older residents’ cognitive and physical function, as well their medicine use, were objectively collected by the ReMInDAR staff, who received training on using validated scales such as the GENEActiv activity tracker [39] and MoCA prior to engaging in the trial [26, 37, 41, 44].”
BackgroundMethodSELENON-Related Myopathy Across the Life Span, a Cross-Sectional Study for Preparing Trial Readiness
Bouman, K., Groothuis, J. T., Doorduin, J., van Alfen, N., ten Cate, F. E. A. U., van den Heuvel, F. M. A., Nijveldt, R., Kamsteeg, E., Dittrich, A. T. M., Draaisma, J. M. T., et al. (2023) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-221673 · Cited by 14
“Patients and/or their parent(s) were [12, 24–38].”
MethodInfluentialAdapted Sojourn Models to Estimate Activity Intensity in Youth: A Suite of Tools
Hibbing, P. R., Ellingson, L. D., Dixon, P. M., & Welk, G. J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001486 · Cited by 14
“A commonly expressed concern has been that certain activities are performed almost exclusively with one hand or the other (34,35), which could make hand dominance a key variable to consider when selecting models and deploying monitors.”
BackgroundLee, S. W., Shim, J., Song, B., Lee, H. J., Bae, H. Y., Park, J. H., Choi, H. R., Yang, J. W., Heo, J. E., Cho, S. M. J., et al. (2018) · Epidemiology and Health · doi:10.4178/epih.e2018060 · Cited by 16
“Vigorous activity time 28 [13-58] 40 [20-82] 23 [11-50] <0.”
BackgroundDuncan, M. J., Dobell, A., Noon, M. R., Clark, C. C. T., Roscoe, C. M. P., Faghy, M. A., Stodden, D. F., Sacko, R. S., & Eyre, E. L. J. (2020) · Sensors · doi:10.3390/s20102776 · Cited by 17
Eston, R. G., & Parfitt, G. (2018) · Routledge eBooks · doi:10.4324/9781315385662-18 · Cited by 20
Self-citationClevenger, K. A., Molesky, M. J., Vusich, J., & Montoye, A. H. K. (2019) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2019.1577737 · Cited by 13
“…wrist-worn monitor recorded greater average activity levels overall, while previous studies assessing specific activity types or using research-grade accelerometers typically show higher movement of the dominant wrist than the nondominant wrist (Esliger et al., 2011; Nelson et al., 2016).”
BackgroundKim, Y., Jang, H., Wang, M., Shi, Q., Strain, T., Sharp, S. J., Yeung, S. L. A., Luo, S., Griffin, S. J., Wareham, N. J., et al. (2023) · Journal of Internal Medicine · doi:10.1111/joim.13715 · Cited by 13
“Previous research has demonstrated a valid estimation of activity intensity [35] and energy expenditure [36, 37], and their association with mortality [38] through wrist accelerometry.”
BackgroundLetts, E., Jakubowski, J., King‐Dowling, S., Clevenger, K. A., Kobsar, D., & Obeid, J. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad45aa · Cited by 13
Cooper, A., Dearnley, K., Williams, K. M., Sharp, S. J., van Sluijs, E. M. F., Brage, S., Sutton, S. R., & Griffin, S. J. (2015) · BMC Public Health · doi:10.1186/s12889-015-1654-0 · Cited by 22
“[26].”
Validación de los cuestionarios PAQ-C e IPAQ-A en niños/as en edad escolar
Martín-Bello, C., Vicente‐Rodríguez, G., Casajús, J. A., & Gómez‐Bruton, A. (2020) · Cultura Ciencia y Deporte · doi:10.12800/ccd.v15i44.1460 · Cited by 21
“Por este motivo ha sido utilizado en numerosos estudios, siendo validado para población adulta (Esliger et al., 2011) e infantil (Phillips, Parfitt, & Rowlands, 2013).”
BackgroundMarshall, Z. A., Mackintosh, K. A., Lewis, M. J., Ellins, E. A., & McNarry, M. A. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13159 · Cited by 15
“and has been shown to be reliable in comparison to other validated accelerometers.(36) During the habitual physical activity assessment period, participants were given diaries to monitor sleep quality and duration, and to record times and reasons for accelerometer removal.”
ResultGasser, B. A., Boesing, M., Schoch, R., Zogg, S., Kröpfl, J. M., Thesenvitz, E., Hanssen, H., Leuppi, J. D., Schmidt‐Trucksäss, A., & Dieterle, T. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.734111 · Cited by 13
Coirolo, N., Casaravilla, C., Tassino, B., & da Silva, A. C. R. (2022) · iScience · doi:10.1016/j.isci.2022.104676 · Cited by 18
“The resulting units for this outcome variable are g$min (Esliger et al., 2011; Phillips et al., 2013).”
BackgroundObjective and subjective measures of sleep in men with Muscular Dystrophy
Morse, C. I., Onambélé-Pearson, G. L., Edwards, B. T., Wong, S. C., & Jacques, M. F. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274970 · Cited by 13
Beltran‐Valls, M. R., Adelantado‐Renau, M., & Moliner‐Urdiales, D. (2018) · Journal of Molecular Neuroscience · doi:10.1007/s12031-018-1122-2 · Cited by 13
“(Esliger et al. 2011) and valid objective measure of PA in young people (r = 0.925, P = 0.001) (Phillips et al. 2013).”
BackgroundInfluentialCriterion and Convergent Validity Evidences of an Accelerometer and a Pedometer
이미영 (2012) · The Korean Journal of Measurement and Evaluation in Physical Education and Sports Science · doi:10.21797/ksme.2012.14.2.001 · Cited by 14
Wrist-Based Accelerometer Cut-Points to Identify Sedentary Time in 5–11-Year-Old Children
Chandler, J., Beets, M. W., Saint‐Maurice, P. F., Weaver, R. G., Cliff, D. P., Drenowatz, C. J., Moore, J. B., Sui, X., & Brazendale, K. (2018) · Children · doi:10.3390/children5100137 · Cited by 18
Laroche, M.-A., Chassé, É., Théoret, D., Lalonde, F. M., & Comtois, A. S. (2022) · Military Medicine · doi:10.1093/milmed/usac334 · Cited by 12
Physical activity and hippocampal volume in young adults
Cherednichenko, A., Miró‐Padilla, A., Adrián‐Ventura, J., Monzonís‐Carda, I., Beltran‐Valls, M. R., Moliner‐Urdiales, D., & Ávila, C. (2024) · Brain Imaging and Behavior · doi:10.1007/s11682-024-00916-4 · Cited by 13
SVENSEN, E., Koscien, C. P., Alamdari, N., Wall, B. T., & Stephens, F. B. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003586 · Cited by 14
“Physical activity was recorded for 7 d before the WK0 visit and again during WK12, by accelerometer (GENEactiv; Activinsights, Cam-bridgeshire, UK) worn continuously on the nondominant wrist, and converted to metabolic equivalents (MET) minutes (23).”
Kwaro, D., Mendt, S., Muma, J. O., Munga, S., Gunga, H., Heim, Z. H., Matzke, I., Bunker, A., Barteit, S., & Maggioni, M. A. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01601-6 · Cited by 14
“Acti-graphy data were processed using the GENEActiv R Markdown Analysis Tools, which are freely available online 40 ; these tools segment raw acceleration, expressedin g units (gravitational acceleration) 41 ; and ambient light signals into epochs classi fi ed as sedentary, light, moderate, or vigorous activity based o…”
Edwards, V. C., Myers, S., Wardle, S. L., Siddall, A. G., Powell, S. D., Needham‐Beck, S. C., Jackson, S., Greeves, J. P., & Blacker, S. D. (2022) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2021-0191 · Cited by 15
Hormazábal‐Aguayo, I., Muñoz‐Pardeza, J., López‐Gil, J. F., Huerta‐Uribe, N., Chueca-Guindulain, M. J., Berrade‐Zubiri, S., Sánchez, E. B., Izquierdo, M., Ezzatvar, Y., & García‐Hermoso, A. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1354734 · Cited by 15
Recess environment and curriculum intervention on children’s physical activity: IPLAY
Nigg, C. R., Kutchman, E. M., Amato, K., Schaefer, C., Zhang, G., Anwar, M. M. U., Anthamatten, P. J., Browning, R. C., Brink, L., & Hill, J. O. (2018) · Translational Behavioral Medicine · doi:10.1093/tbm/iby015 · Cited by 12
“It has been validated for use among both children and adults [34].”
BackgroundSzeszulski, J., Vega‐López, S., Todd, M. W., Ray, F., Behar, A. I., Campbell, M., Chavez, A., Eckert, R., Lorenzo-Quintero, A., Hartmann, L., et al. (2020) · Contemporary Clinical Trials · doi:10.1016/j.cct.2020.105956 · Cited by 13
“Upon the GeneActiv device's return, data will be downloaded from it and then processed using wrist-worn cut points for adults [20] and children [57].”
MethodEffectiveness of Minimal Contact Interventions: An RCT
Hajna, S., Sharp, S. J., Cooper, A., Williams, K. M., van Sluijs, E. M. F., Brage, S., Griffin, S. J., & Sutton, S. R. (2021) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2020.10.010 · Cited by 13
“Participants in the Activity Band group received a triaxial wrist-worn activity tracker that contained an accelerometer similar to one described previously.(26) The activity tracker was developed by Imperative Health, which was a part of AXA ICAS Limited, an employee assistance program, health, and well-being services…”
MethodSalagaras, B. S., MacKenzie‐Shalders, K. L., Nelson, M. J., Fraysse, F., Wycherley, T. P., Slater, G., McLellan, C., Kumar, K., & Coffey, V. G. (2021) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003945 · Cited by 12
“001) over 15 different frequency and acceleration conditions (17).”
BackgroundWilletts, M., Hollowell, S., Aslett, L. J. M., Holmes, C. C., & Doherty, A. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/187625 · Cited by 12
Early warning signals observed in motor activity preceding mood state change in bipolar disorder
Jakobsen, P., Côté‐Allard, U., Riegler, M. A., Stabell, L. A., Stautland, A., Nordgreen, T., Tørresen, J., Fasmer, O. B., & Oedegaard, K. J. (2024) · Bipolar Disorders · doi:10.1111/bdi.13430 · Cited by 14
Powell, S. D., Siddall, A. G., Needham‐Beck, S. C., Edwards, V. C., Light, N., Jackson, S., Greeves, J. P., Blacker, S. D., & Myers, S. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14340 · Cited by 11
Schoenfelder, A., Metcalf, B. S., Langford, J., Stathi, A., Western, M. J., & Hillsdon, M. M. (2023) · Sensors · doi:10.3390/s23115122 · Cited by 11
“The acceleration measurement of the GENEActiv has been shown to have excellent intra-device and inter-device reliability [55].”
MethodMiró‐Padilla, A., Adrián‐Ventura, J., Cherednichenko, A., Monzonís‐Carda, I., Beltran‐Valls, M. R., Moliner‐Urdiales, D., & Ávila, C. (2023) · Communications Biology · doi:10.1038/s42003-023-05423-8 · Cited by 13
Estimating cut points: A simple method for new wearables
Hickey, A., Newham, J. J., Sławińska, M., Kwaśnicka, D., McDonald, S., Din, S. D., Sniehotta, F. F., Davis, P., & Godfrey, A. (2015) · Maturitas · doi:10.1016/j.maturitas.2015.10.003 · Cited by 13
“However, a comparison of the cut points derived in this study for the PRO-Diary TM to another wrist worn device shows some similarities, where participants also performed a treadmill-based protocol at comparable speeds [12].”
Towards a Portable Model to Discriminate Activity Clusters from Accelerometer Data
Jones, P. J., Mirkes, E. M., Yates, T. E., Edwardson, C. L., Catt, M., Davies, M. J., Khunti, K., & Rowlands, A. V. (2019) · Sensors · doi:10.3390/s19204504 · Cited by 11
“Our purpose was an exploratory analysis and we aimed to ascertain which features met the threshold for clustering in the development dataset, which, by definition, was comprised of activity types across the intensity range and representative of daily living [14,15].”
MethodSelf-citationWagner, J., Knaier, R., Königstein, K., Klenk, C., Carrard, J., Lichtenstein, E., Scharnagl, H., März, W., Hanssen, H., Hinrichs, T., et al. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.596240 · Cited by 11
Social networks and neural receptivity to persuasive health messages.
Pandey, P., Kang, Y., Cooper, N., O’Donnell, M. B., & Falk, E. B. (2021) · Health Psychology · doi:10.1037/hea0001059 · Cited by 11
Nichles, A., Zmicerevska, N., Song, Y. J. C., Wilson, C. E., McHugh, C. M., Hamilton, B. A., Crouse, J. J., Rohleder, C., Carpenter, J. S., Ho, N., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044731 · Cited by 13
Drew, C. J. G., Quinn, L., Hamana, K., Williams‐Thomas, R., Marsh, L. L., Dimitropoulou, P., Playle, R., Griffin, B. A., Kelson, M. J., Schubert, R., et al. (2019) · Physical Therapy · doi:10.1093/ptj/pzz075 · Cited by 11
“33 We are developing algorithms specific to HD to transform the accelerometer data into summary data specifying periods of physical activity, sedentary, and sleep behaviours.”
Duncan, M. J., Eyre, E. L. J., Cox, V. M., Roscoe, C. M. P., Faghy, M. A., Tallis, J. A., & Dobell, A. (2020) · Acta Paediatrica · doi:10.1111/apa.15189 · Cited by 14
“ROC curve analysis was conducted as described previously and calculation of sensitivity (Se) and specificity (Sp) was also performed (23).”
MethodHormazábal‐Aguayo, I., Huerta‐Uribe, N., Muñoz‐Pardeza, J., Ezzatvar, Y., Izquierdo, M., & García‐Hermoso, A. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae451 · Cited by 10
Huerta‐Uribe, N., Hormazábal‐Aguayo, I., Muñoz‐Pardeza, J., Chueca-Guindulain, M. J., Berrade‐Zubiri, S., Sesma, C. A., Sánchez, E. B., Ezzatvar, Y., Sepulveda, R. A. Y., Izquierdo, M., et al. (2024) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2024-002177 · Cited by 10
“22 Accel-erometer data were extracted using the GENEActiv PC Software (V.3.3), and processed and analysed using the R-package GGIR.”
InfluentialSuárez-Alcázar, M. P., Ayora, A. F., Muriach, M., Recacha-Ponce, P., Garcia-Roca, M. E., Coret, A., Pastor, J. C., Salas‐Medina, P., & Collado‐Boira, E. (2025) · Healthcare · doi:10.3390/healthcare13091083 · Cited by 10
“We also measured lifestyles related to the amount of physical activity by accelerometry using GENEActiv (Activinsights Ltd. Kimbolton, Cambridgeshire, UK) portable wearables [50].”
On convex decision regions in deep network representations
Tětková, L., Brüsch, T., Dorszewski, T., Mager, F. M., Aagaard, R. Ø., Foldager, J., Alstrøm, T. S., & Hansen, L. K. (2025) · Nature Communications · doi:10.1038/s41467-025-60809-y · Cited by 18
Nève, G., Wagner, J., Knaier, R., Infanger, D., Klenk, C., Carrard, J., Hinrichs, T., Hanssen, H., Schmidt‐Trucksäss, A., & Königstein, K. (2022) · Nutrients · doi:10.3390/nu14173616 · Cited by 11
Individual light history matters to deal with the Antarctic summer
Castillo, J., Tonon, A. C., Hidalgo, M. P. L., da Silva, A. C. R., & Tassino, B. (2023) · Scientific Reports · doi:10.1038/s41598-023-39315-y · Cited by 10
Dericioglu, D., Methven, L., & Clegg, M. (2025) · European Journal of Nutrition · doi:10.1007/s00394-024-03571-z · Cited by 10
“Consequently, discrepancies between TEE assessed with sPAR, physical activity levels measured by accelerometers, and self-reported PASE scores are expected and have been widely reported in the literature [49, 59–61].”
Carter, S., Hill, A. M., Yandell, C. A., Wood, L. G., Coates, A. M., & Buckley, J. D. (2025) · American Journal of Clinical Nutrition · doi:10.1016/j.ajcnut.2025.05.001 · Cited by 11
Classification of Rest and Active Periods in Actigraphy Data Using PCA
Wagner-Muns, I. M., Lad, Y. D., Guardiola, I. G., & Thimgan, M. S. (2017) · Procedia Computer Science · doi:10.1016/j.procs.2017.09.041 · Cited by 10
Impact of visual impairment on physical activity in early and late age-related macular degeneration
Heinemann, M., Welker, S. G., Li, J. Q., Wintergerst, M. W. M., Turski, G. N., Turski, C. A., Terheyden, J. H., Mauschitz, M. M., Holz, F. G., & Finger, R. P. (2019) · PLoS ONE · doi:10.1371/journal.pone.0222045 · Cited by 10
“[28,29] We summarized PA data into minutes per week for sedentary, low, moderate, vigorous and moderate-to-vigorous (MVPA) activity.”
MethodAfaq, S., Loh, M. C. S., Kooner, J. S., & Chambers, J. C. (2020) · Physical Activity and Health · doi:10.5334/paah.46 · Cited by 10
Nnamoko, N., Cabrera-Diego, L. A., Campbell, D., Sanders, G., Fairclough, S. J., & Korkontzelos, I. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106165 · Cited by 12
Post, D., van Agteren, J. E., Kasai, D., Barrett, A., Doyle, M., Kernot, J., Baker, A., & Parfitt, G. (2021) · Health & Social Care in the Community · doi:10.1111/hsc.13449 · Cited by 13
Longitudinal Associations of Healthy Behaviors on Fitness in Adolescents: DADOS Study
Beltran‐Valls, M. R., Adelantado‐Renau, M., Mota, J. A. P. S., & Moliner‐Urdiales, D. (2021) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2021.04.009 · Cited by 10
Normative wrist-worn accelerometer values for self-paced walking and running: a walk in the park
Dawkins, N. P., Yates, T., Soczawa-Stronczyk, A. A., Bocian, M., Edwardson, C. L., Maylor, B. D., Davies, M. J., Khunti, K., & Rowlands, A. V. (2021) · Journal of Sports Sciences · doi:10.1080/02640414.2021.1976491 · Cited by 11
“Previous research assessing the association between accelerometer output and ambulatory speed is largely based on laboratory-based protocols, metronomes to control the walking pace, and/or employed treadmills (Duncan et al., 2020; Esliger et al., 2011; Fraysse et al., 2020; Hildebrand et al., 2014).”
BackgroundSelf-citationCross-validation of Waist-Worn GENEA Accelerometer Cut-Points
Welch, W. A., Bassett, D. R., Freedson, P. S., John, D., Steeves, J. A., Conger, S. A., CEASER, T. G., Howe, C. A., & Sasaki, J. E. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000283 · Cited by 12
“(8) reported a criterion validity of r = 0.”
BackgroundMethodInfluentialCelis-Morales, C. A., Lyall, D. M., Bailey, M. E. S., Petermann-Rocha, F. E., Anderson, J. J., Ward, J., Mackay, D., Welsh, P. I., Pell, J. P., Sattar, N. A., et al. (2019) · Obesity · doi:10.1002/oby.22417 · Cited by 11
“Mean daily accelerations (cumulative acceleration during each day, expressed in milligravity per day), calculated using Open Movement AX3 open-source software (Open Lab, Newcastle University, UK) as previously described (27), were used as the objectively measured total PA.”
MethodFalck, R. S., Best, J. R., Li, M. C. R., Eng, J. J., & Liu-Ambrose, T. Y. L. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2019.00203 · Cited by 10
Carter, S., Hill, A. M., Yandell, C. A., Buckley, J. D., Tan, S., Rogers, G. B., Childs, J. T., Matheson, M., Lamb, K., Ward, S. J., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-036542 · Cited by 13
Diaz, K. M., Boudreaux, B. D., Xu, C., Sanchez, G. J., Murdock, M. E., Cruz, G. J., Jurado, A., Gonzalez, A., Chang, M. J., Scott, A., et al. (2025) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.124.011644 · Cited by 10
Rey-López, J. P., Lee, D. H., Ferrari, G., Giovannucci, E. L., & Rezende, L. F. M. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20116027 · Cited by 11
“Remarkably, only two validation studies [20,21] found Spearman’s or Pearson’s coefficient correlations above 0.”
BackgroundMonteagudo, P., Beltran‐Valls, M. R., Adelantado‐Renau, M., & Moliner‐Urdiales, D. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2268359 · Cited by 9
“(Eslinger et al., 2011) and a valid measure of PA in young people ( r = 0.925, P = 0.001) (Phillips et al., 2013).”
BackgroundInfluentialTarca, B. D., Jesudason, S., Bennett, P. N., Wycherley, T. P., & Ferrar, K. (2024) · Kidney International Reports · doi:10.1016/j.ekir.2024.01.057 · Cited by 10
“Physical activity intensity thresholds established by Esliger et al. 13 were applied to the period of active wear.”
Uphill, A., Kendall, K. L., Fogarty, A. L., Guppy, S. N., Brown, H., Zomer, T., Parker, S. P. A., & Haff, G. G. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12080 · Cited by 10
Interventions reducing sedentary behaviour of adults: An update of evidence
Sutherland, C. A., Kynn, M., Cole, R. L., & Gray, M. A. (2019) · Health Education Journal · doi:10.1177/0017896919878225 · Cited by 9
“However, the GENActiv also uses physical activity intensity cut off points to estimate the time adults spend sedentary, which were developed from a validation study (Esliger et al., 2011).”
MethodQuantifying shoulder activity after rotator cuff repair: Technique and preliminary results
Ruder, M. C., Zauel, R. R., Diefenbach, B. J., & Bey, M. J. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25122 · Cited by 9
“correlation between the activity monitor and Instron‐based measures of acceleration.(32) As an additional assessment of accuracy, we compared accelerations measured with the wrist‐worn activity monitor to accelerations determined with a video‐based motion capture system.”
MethodAebischer, O., Suter, M. R., Vollenweider, P., & Marques-Vidal, P. M. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-057288 · Cited by 11
Pérez, A. M. L., Collado‐Mateo, D., Gil-Arias, A., Gutiérrez, L., Écija, C., Catalá, P., & Peñacoba, C. (2023) · Biology · doi:10.3390/biology12010085 · Cited by 12
“Author Contributions: Conceptualization: C.P., A.G.A., A.M.L.-P. and D.C.-M.; Data curation: L.G., C.É. and P.C.; Formal analysis: A.M.L.-P., D.C.-M. and A.G.A.; Funding acquisition: C.P.; Investigation: C.P., A.G.A., A.M.L.-P., L.G., C.É., P.C. and D.C.-M.; Methodology: C.P., A.G.A., A.M.L.-P. and D.C.-M.; Resources:…”
MethodComparison of different software for processing physical activity measurements with accelerometry
Verhoog, S., Gubelmann, C., Bano, A., Muka, T., Franco, O. H., & Marques-Vidal, P. M. (2023) · Scientific Reports · doi:10.1038/s41598-023-29872-7 · Cited by 10
Generalized activity recognition using accelerometer in wearable devices for IoT applications
Safadi, E. A., Mohammad, F., Iyer, D., Smiley, B. J., & Jain, N. K. (2016) · IEEE International Conference on Advanced Video and Signal Based Surveillance (AVSS) · doi:10.1109/avss.2016.7738020 · Cited by 10
Potential role of biologgers to automate detection of lame ewes and lambs
Lewis, K., Price, E., Croft, D. P., Green, L. E., Ozella, L., Cattuto, C., & Langford, J. (2023) · Applied Animal Behaviour Science · doi:10.1016/j.applanim.2023.105847 · Cited by 8
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · BMC Medicine · doi:10.1186/s12916-024-03497-7 · Cited by 9
“To deduce sleep state, the participants were made to wear a wrist-worn triaxial accelerometer (Axivity AX3) for capturing tri-axial acceleration data at 100 Hz [13– 15].”
MethodBruijel, J., Stapert, S. Z., Vermeeren, A., Ponsford, J. L., & Heugten, C. M. V. (2018) · JMIR Research Protocols · doi:10.2196/11295 · Cited by 9
“…Activinsights Ltd, Cambridgeshire, United Kingdom) measures the movement/motor activity of the participant, and thereby, the time spent in sedentary behavior, light intensity physical activity, moderate to vigorous physical activity, and vigorous physical activity can be determined [36].”
Domingo, C. H., Hernando, C., Martínez‐Navarro, I., Collado‐Boira, E., Panizo, N., & Hernando, B. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176196 · Cited by 8
Jacques, M. F., Onambélé-Pearson, G. L., Reeves, N. D., Stebbings, G. K., Dawson, E. A., Stockley, R., Edwards, B. T., & Morse, C. I. (2020) · Disability and Rehabilitation · doi:10.1080/09638288.2020.1808087 · Cited by 8
Relationship Between Parent and Child Physical Activity Using Novel Acceleration Metrics
Donnelly, S., Buchan, D. S., McLellan, G., & Arthur, R. (2020) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2020.1817295 · Cited by 9
“Accelerometers can be worn continuously on sites including the wrist and hip (Fairclough et al., 2016).”
BackgroundDonnelly, S., Buchan, D. S., McLellan, G., & Arthur, R. (2021) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2021.1918322 · Cited by 11
Community Participation by People with Chronic Obstructive Pulmonary Disease
Malaguti, C., Holland, A. E., McDonald, C. F., Mahal, A. S., Alison, J. A., Hill, C. J., Zanaboni, P., O’Halloran, P., Bondarenko, J., Macdonald, H., et al. (2021) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412555.2021.1966761 · Cited by 9
“The GeneActiv is a validated wrist-worn, tri-axial accelerometer [23], demonstrated to achieve >90% accuracy in classifying activity intensities [24].”
MethodHennis, P. J., Murphy, E., Meijer, R. I., Lachmann, R., Ramachandran, R., Bordoli, C., Rayat, G., & Tomlinson, D. J. (2022) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-022-02184-1 · Cited by 9
“Analysis of the data was conducted using GENEActiv macro file version 9, using validated activity cut-off points [49].”
MethodEndogenous circadian temperature rhythms relate to adolescents’ daytime physical activity
Kuula, L., Lipsanen, J. O., Partonen, T., Kauramäki, J., Halonen, R., & Pesonen, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.947184 · Cited by 9
“As our participants were close to adult age, we formed intensity categories based on validated adult cutpoints (Esliger et al., 2011), and then classified activity into three categories: sedentary, light PA, and MVPA.”
MethodDifferentiating Between Walking and Stair Climbing Using Raw Accelerometry Data
Fadel, W. F., Urbanek, J. K., Albertson, S. R., Li, X., Chomistek, A. K., & Harezlak, J. (2019) · Statistics in Biosciences · doi:10.1007/s12561-019-09241-7 · Cited by 8
“However, the usual method for describing accelerometer-measured PA is to use activity counts and a cut-point approach which classifies intensities of PA rather than the specific activity occurring [6,16,21,23].”
MethodMaia, A. C., Hogarth, L. W., Burkett, B. J., & Payton, C. J. (2021) · Journal of Sports Sciences · doi:10.1080/02640414.2021.1935114 · Cited by 8
Eser, P., González-Jaramillo, N., Weber, S., Fritsche, J., Femiano, R., Werner, C., Casanova, F., Bano, A., Franco, O. H., & Wilhelm, M. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.951042 · Cited by 8
“Some calibration studies of accelerometers used steady-state activities, such as walking, running, and cycling, which require >3 METs when performed continuously for longer than 1–2 min when metabolism has reached a steady state (13, 14).”
BackgroundBrazendale, K., Beets, M. W., Rowlands, A. V., Chandler, J., Fairclough, S. J., Boddy, L. M., Olds, T., Parfitt, G., Noonan, R. J., Downs, S. J., et al. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1470373 · Cited by 8
“(Esliger et al., 2011) The ActiGraph GT3X+, worn on the wrist, has been used in NHANES since 2011, and while estimates of physical activity intensity from these wrist-worn accelerometers have demonstrated strong reliability and validity, (Esliger et al., 2011; Phillips, Parfitt, & Rowlands, 2013)…”
BackgroundMethodInfluentialSelf-citationDeterminants of bone outcomes in adolescent athletes at baseline: The PRO-BONE study
Gracia‐Marco, L., Vlachopoulos, D., Ubago‐Guisado, E., BARKER, A. R., Fatouros, I. G., Avlotini, A., Knapp, K. K., Moreno, L. A., & Williams, C. A. (2017) · Bone Abstracts · doi:10.1530/boneabs.6.p012 · Cited by 8
Gauci, J., Olds, T., Maher, C. A., Watson, A., Fraysse, F., Munzberg, M., Hoepfl, I., & Dumuid, D. (2023) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-023-00023-7 · Cited by 7
“The acceleration magnitude (SVM) [33] was computed as the absolute value of the Euclidean norm of the acceleration signal, minus 1 g (1 g = 9.”
MethodInfluential
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.