The DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Quantitative radiomics studies for tissue characterization: a review of technology and methodological procedures
Open accessAbstract
Quantitative analysis of tumour characteristics based on medical imaging is an emerging field of research. In recent years, quantitative imaging features derived from CT, positron emission tomography and MR scans were shown to be of added value in the prediction of outcome parameters in oncology, in what is called the radiomics field. However, results might be difficult to compare owing to a lack of standardized methodologies to conduct quantitative image analyses. In this review, we aim to present an overview of the current challenges, technical routines and protocols that are involved in quantitative imaging studies. The first issue that should be overcome is the dependency of several features on the scan acquisition and image reconstruction parameters. Adopting consistent methods in the subsequent target segmentation step is evenly crucial. To further establish robust quantitative image analyses, standardization or at least calibration of imaging features based on different feature extraction settings is required, especially for texture- and filter-based features. Several open-source and commercial software packages to perform feature extraction are currently available, all with slightly different functionalities, which makes benchmarking quite challenging. The number of imaging features calculated is typically larger than the number of patients studied, which emphasizes the importance of proper feature selection and prediction model-building routines to prevent overfitting. Even though many of these challenges still need to be addressed before quantitative imaging can be brought into daily clinical practice, radiomics is expected to be a critical component for the integration of image-derived information to personalize treatment in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
FCM: The fuzzy c-means clustering algorithm
Bezdek, J. C., Ehrlich, R., & Full, W. (1984) · Computers & Geosciences · doi:10.1016/0098-3004(84)90020-7 · Cited by 6,608
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Self-citationDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Self-citationFrom RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 4×
“lung lobe, distance to the organ at risk) have been used.(72)”
BackgroundInfluentialSelf-citationTexture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. (2015) · BMC Medicine · doi:10.1186/s12916-014-0241-z · Cited by 1,927
Huang, Y.-Q., Liang, C.-H., He, L., Tian, J., Liang, C.-S., Chen, X., Ma, Z.-L., & Liu, Z.-Y. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2015.65.9128 · Cited by 1,765
Feature selection, L 1 vs. L 2 regularization, and rotational invariance
Ng, A. Y. (2004) · Twenty-first international conference on Machine learning - ICML '04 · doi:10.1145/1015330.1015435 · Cited by 1,572
The National Lung Screening Trial: Overview and Study Design
National Lung Screening Trial Research Team (2011) · Radiology · doi:10.1148/radiol.10091808 · Cited by 1,274
Textural features corresponding to textural properties
Amadasun, M., & King, R. (1989) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.44046 · Cited by 1,148
Machine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Self-citationVallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Huang, Y., Liu, Z., He, L., Chen, X., Pan, D., Ma, Z., Liang, C., Tian, J., & Liang, C. (2016) · Radiology · doi:10.1148/radiol.2016152234 · Cited by 743
MaZda—A software package for image texture analysis
Szczypiński, P. M., Strzelecki, M., Materka, A., & Klepaczko, A. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.08.005 · Cited by 712
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
CT-based radiomic signature predicts distant metastasis in lung adenocarcinoma
Coroller, T. P., Grossmann, P., Hou, Y., Rios Velazquez, E., Leijenaar, R. T. H., Hermann, G., Lambin, P., Haibe-Kains, B., Mak, R. H., & Aerts, H. J. W. L. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.02.015 · Cited by 695 · cited 4×
“Size (volume and maximal diameter) and shape measures (sphericity, compactness and surface-to-volume ratio) have been described in radiomics research.(37,61) Finally, features relating to tumour location (e.”
BackgroundMethodInfluentialSelf-citationMeasuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Self-citationReproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Non–Small Cell Lung Cancer: Histopathologic Correlates for Texture Parameters at CT
Ganeshan, B., Goh, V., Mandeville, H. C., Ng, Q. S., Hoskin, P. J., & Miles, K. A. (2013) · Radiology · doi:10.1148/radiol.12112428 · Cited by 447
Metrology Standards for Quantitative Imaging Biomarkers
Sullivan, D. C., Obuchowski, N. A., Kessler, L. G., Raunig, D. L., Gatsonis, C., Huang, E. P., Kondratovich, M., McShane, L. M., Reeves, A. P., Barboriak, D. P., et al. (2015) · Radiology · doi:10.1148/radiol.2015142202 · Cited by 435
Radiomic feature clusters and Prognostic Signatures specific for Lung and Head & Neck cancer
Parmar, C., Leijenaar, R. T. H., Grossmann, P., Rios Velazquez, E., Bussink, J., Rietveld, D., Rietbergen, M. M., Haibe-Kains, B., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep11044 · Cited by 434
Self-citationLeijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Self-citationLeijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Self-citationNeighboring gray level dependence matrix for texture classification
Sun, C., & Wee, W. G. (1983) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(83)90032-4 · Cited by 408
Radiomic Machine-Learning Classifiers for Prognostic Biomarkers of Head and Neck Cancer
Parmar, C., Grossmann, P., Rietveld, D., Rietbergen, M. M., Lambin, P., & Aerts, H. J. W. L. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00272 · Cited by 407
Self-citationQuantifying tumour heterogeneity with CT
Ganeshan, B., & Miles, K. A. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0015 · Cited by 395
Cook, G. J. R., Yip, C., Siddique, M., Goh, V., Chicklore, S., Roy, A., Marsden, P., Ahmad, S., & Landau, D. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107375 · Cited by 394
Wibmer, A., Hricak, H., Gondo, T., Matsumoto, K., Veeraraghavan, H., Fehr, D., Zheng, J., Goldman, D., Moskowitz, C., Fine, S. W., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3701-8 · Cited by 391
Feature Selection Using Principal Component Analysis
Song, F., Guo, Z., & Mei, D. (2010) · 2010 International Conference on System Science, Engineering Design and Manufacturing Informatization · doi:10.1109/icsem.2010.14 · Cited by 384
Ng, F., Kozarski, R., Ganeshan, B., & Goh, V. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.10.023 · Cited by 362
Machine learning approaches in medical image analysis: From detection to diagnosis
de Bruijne, M. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.032 · Cited by 347
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Zhao, B., James, L. P., Moskowitz, C. S., Guo, P., Ginsberg, M. S., Lefkowitz, R. A., Qin, Y., Riely, G. J., Kris, M. G., & Schwartz, L. H. (2009) · Radiology · doi:10.1148/radiol.2522081593 · Cited by 339
Radiomic phenotype features predict pathological response in non-small cell lung cancer
Coroller, T. P., Agrawal, V., Narayan, V., Hou, Y., Grossmann, P., Lee, S. W., Mak, R. H., & Aerts, H. J. W. L. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.04.004 · Cited by 327
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
ibex: An open infrastructure software platform to facilitate collaborative work in radiomics
Zhang, L., Fried, D. V., Fave, X. J., Hunter, L. A., Yang, J., & Court, L. E. (2015) · Medical Physics · doi:10.1118/1.4908210 · Cited by 316
Reproducibility and Prognosis of Quantitative Features Extracted from CT Images
Balagurunathan, Y., Gu, Y., Wang, H., Kumar, V., Grove, O., Hawkins, S., Kim, J., Goldgof, D. B., Hall, L. O., Gatenby, R. A., et al. (2014) · Translational Oncology · doi:10.1593/tlo.13844 · Cited by 306
van Baardwijk, A., Bosmans, G., Boersma, L., Buijsen, J., Wanders, S., Hochstenbag, M., van Suylen, R.-J., Dekker, A., Dehing-Oberije, C., Houben, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.067 · Cited by 295
Self-citationPredicting Malignant Nodules from Screening CT Scans
Hawkins, S., Wang, H., Liu, Y., Garcia, A., Stringfield, O., Krewer, H., Li, Q., Cherezov, D., Gatenby, R. A., Balagurunathan, Y., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.07.002 · Cited by 293
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Test–Retest Reproducibility Analysis of Lung CT Image Features
Balagurunathan, Y., Kumar, V., Gu, Y., Kim, J., Wang, H., Liu, Y., Goldgof, D. B., Hall, L. O., Korn, R., Zhao, B., et al. (2014) · Journal of Digital Imaging · doi:10.1007/s10278-014-9716-x · Cited by 259
Impact of Image Reconstruction Settings on Texture Features in 18F-FDG PET
Yan, J., Chu-Shern, J. L., Loi, H. Y., Khor, L. K., Sinha, A. K., Quek, S. T., Tham, I. W. K., & Townsend, D. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.156927 · Cited by 242
Volumetric CT-based segmentation of NSCLC using 3D-Slicer
Velazquez, E. R., Parmar, C., Jermoumi, M., Mak, R. H., van Baardwijk, A., Fennessy, F. M., Lewis, J. H., De Ruysscher, D., Kikinis, R., Lambin, P., et al. (2013) · Scientific Reports · doi:10.1038/srep03529 · Cited by 240
Self-citationCunliffe, A., Armato, S. G., Castillo, R., Pham, N., Guerrero, T., & Al-Hallaq, H. A. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.11.030 · Cited by 225
Fried, D. V., Tucker, S. L., Zhou, S., Liao, Z., Mawlawi, O., Ibbott, G., & Court, L. E. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.07.020 · Cited by 213
Hatt, M., Tixier, F., Cheze Le Rest, C., Pradier, O., & Visvikis, D. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2486-8 · Cited by 208
van Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1845-6 · Cited by 182
Hatt, M., Cheze le Rest, C., Descourt, P., Dekker, A., De Ruysscher, D., Oellers, M., Lambin, P., Pradier, O., & Visvikis, D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.08.018 · Cited by 179
Self-citationBuckler, A. J., Bresolin, L., Dunnick, N. R., Sullivan, D. C., & For the Group (2011) · Radiology · doi:10.1148/radiol.10100799 · Cited by 175
Fave, X., Mackin, D., Yang, J., Zhang, J., Fried, D., Balter, P., Followill, D., Gomez, D., Kyle Jones, A., Stingo, F., et al. (2015) · Medical Physics · doi:10.1118/1.4934826 · Cited by 171
Liang, C., Huang, Y., He, L., Chen, X., Ma, Z., Dong, D., Tian, J., Liang, C., & Liu, Z. (2016) · Oncotarget · doi:10.18632/oncotarget.8919 · Cited by 169
Gnep, K., Fargeas, A., Gutiérrez-Carvajal, R. E., Commandeur, F., Mathieu, R., Ospina, J. D., Rolland, Y., Rohou, T., Vincendeau, S., Hatt, M., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25335 · Cited by 162
Huang, K., Senthi, S., Palma, D. A., Spoelstra, F. O. B., Warner, A., Slotman, B. J., & Senan, S. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.06.047 · Cited by 151
Hatt, M., Rest, C. C. L., van Baardwijk, A. A. W., Lambin, P., Pradier, O., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092767 · Cited by 140
Self-citationFang, Y.-H. D., Lin, C., Shih, M.-J., Wang, H., Ho, T., Liao, C.-T., & Yen, T. (2014) · BioMed Research International · doi:10.1155/2014/248505 · Cited by 133
Panth, K. M., Leijenaar, R. T. H., Carvalho, S., Lieuwes, N. G., Yaromina, A., Dubois, L., & Lambin, P. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.06.013 · Cited by 133
Self-citationOliver, J. A., Budzevich, M. M., Zhang, G. G., Dilling, T. J., Latifi, K., & Moros, E. G. (2015) · Translational Oncology · doi:10.1016/j.tranon.2015.11.013 · Cited by 129
Lu, L., Lv, W., Jiang, J., Ma, J., Feng, Q., Rahmim, A., & Chen, W. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0973-6 · Cited by 117
Desseroit, M.-C., Visvikis, D., Tixier, F., Majdoub, M., Perdrisot, R., Guillevin, R., Rest, C. C. L., & Hatt, M. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3325-5 · Cited by 116
Preliminary investigation into sources of uncertainty in quantitative imaging features
Fave, X. J., Cook, M. C., Frederick, A., Zhang, L., Yang, J., Fried, D., Stingo, F. C., & Court, L. E. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.04.006 · Cited by 105
Application of wavelet techniques for cancer diagnosis using ultrasound images: A Review
Sudarshan, V. K., Mookiah, M. R. K., Acharya, U. R., Chandran, V., Molinari, F., Fujita, H., & Ng, K. H. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.12.006 · Cited by 91
Gao, X., Chu, C., Li, Y., Lu, P., Wang, W., Liu, W., & Yu, L. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.11.006 · Cited by 87
Grootjans, W., Tixier, F., van der Vos, C. S., Vriens, D., Rest, C. C. L., Bussink, J., Oyen, W. J. G., de Geus‐Oei, L., Visvikis, D., & Visser, E. P. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.173112 · Cited by 87
The precision of textural analysis in 18F-FDG-PET scans of oesophageal cancer
Doumou, G., Siddique, M. M., Tsoumpas, C., Goh, V., & Cook, G. (2015) · European Radiology · doi:10.1007/s00330-015-3681-8 · Cited by 84
Texture-Based Analysis of COPD: A Data-Driven Approach
Sørensen, L., Nielsen, M., Lo, P., Ashraf, H., Pedersen, J. H., & de Bruijne, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2164931 · Cited by 83
Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET
Hatt, M., Lamare, F., Boussion, N., Turzo, A., Collet, C., Salzenstein, F., Roux, C., Jarritt, P. H., Carson, K. J., Rest, C. C. L., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/010 · Cited by 79
Variability of clinical target volume delineation for definitive radiotherapy in cervix cancer
Eminowicz, G., & McCormack, M. M. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.10.007 · Cited by 75
Yip, S. S. F., McCall, K. C., Aristophanous, M., Chen, A. B., Aerts, H. J. W. L., & Berbeco, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115510 · Cited by 71
Echegaray, S., Gevaert, O., Shah, R. P., Kamaya, A., Louie, J. D., Kothary, N., & Napel, S. A. (2015) · Journal of medical imaging · doi:10.1117/1.jmi.2.4.041011 · Cited by 67
Hoeben, B. A. W., Starmans, M. H. W., Leijenaar, R. T. H., Dubois, L. J., van der Kogel, A. J., Kaanders, J. H., Boutros, P. C., Lambin, P., & Bussink, J. (2014) · BMC Cancer · doi:10.1186/1471-2407-14-130 · Cited by 28
Self-citationAutomatic Differential Diagnosis of Melanocytic Skin Tumors Using Ultrasound Data
Andrėkutė, K., Linkevičiūtė, G., Raišutis, R., Valiukevičienė, S., & Makštienė, J. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.07.026 · Cited by 27
Classification of Breast Tumors Using Sonographic Texture Analysis
Ardakani, A. A., Gharbali, A., & Mohammadi, A. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.2.225 · Cited by 24
Li, F. (2015) · Radiological Physics and Technology · doi:10.1007/s12194-015-0319-0 · Cited by 2
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Self-citationEleven grand challenges in single-cell data science
Lähnemann, D., Köster, J., Szczurek, E., McCarthy, D. J., Hicks, S. C., Robinson, M. D., Vallejos, C. A., Campbell, K. R., Beerenwinkel, N., Mahfouz, A., et al. (2020) · Genome Biology · doi:10.1186/s13059-020-1926-6 · Cited by 1,327
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Metadata
- Authors
- Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-01-26
- Volume
- 90
- Issue
- 1070
- Pages
- 20160665-20160665
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2566749675
- Cited by
- 363
- References
- 84
- FWCI
- 30.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.