Micro-CT enables microlocalisation and quantification of Her2-targeted gold nanoparticles within tumour regions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Gold nanoparticles are of interest as potential in vivo diagnostic and therapeutic agents, as X-ray contrast agents, drug delivery vehicles and radiation enhancers. The aim of this study was to quantitatively determine their targeting and microlocalisation in mouse tumour models after intravenous injection by using micro-CT. METHODS: Gold nanoparticles (15 nm) were coated with polyethylene glycol and covalently coupled to anti-Her2 antibodies (Herceptin). In vitro, conjugates incubated with Her2+ (BT-474) and Her2- (MCF7) human breast cancer cells showed specific targeted binding with a Her2+ to Her2- gold ratio of 39.4±2.7:1. Nude mice, simultaneously bearing subcutaneous Her2+ and Her2- human breast tumours in opposite thighs were prepared. Gold nanoparticles alone, conjugated to Herceptin or to a non-specific antibody were compared. After intravenous injection of the gold nanoparticles, gold concentrations were determined by atomic absorption spectroscopy. Microlocalisation of gold was carried out by calibrated micro-CT, giving both the radiodensities and gold concentrations in tumour and non-tumour tissue. RESULTS: All gold nanoparticle constructs showed accumulation, predominantly at tumour peripheries. However, the Herceptin-gold nanoparticles showed the best specific uptake in their periphery (15.8±1.7% injected dose per gram), 1.6-fold higher than Her2- tumours and 22-fold higher than surrounding muscle. Imaging readily enabled detection of small, 1.5 mm-thick tumours. CONCLUSION: In this pre-clinical study, antibody-targeted 15 nm gold nanoparticles showed preferential uptake in cognate tumours, but even untargeted gold nanoparticles enhanced the visibility of tumour peripheries and enabled detection of millimetre-sized tumours. Micro-CT enabled quantification within various regions of a tumour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Gold nanoparticles for applications in cancer radiotherapy: Mechanisms and recent advancements
Her, S., Jaffray, D. A., & Allen, C. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.12.012 · Cited by 865
Multifunctional Gold Nanoparticles for Diagnosis and Therapy of Disease
Mieszawska, A. J., Mulder, W. J. M., Fayad, Z. A., & Cormode, D. P. (2013) · Molecular Pharmaceutics · doi:10.1021/mp3005885 · Cited by 724
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
The Use of Alternative Strategies for Enhanced Nanoparticle Delivery to Solid Tumors
Izci, M., Maksoudian, C., Manshian, B. B., & Soenen, S. J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00779 · Cited by 506
Physical basis and biological mechanisms of gold nanoparticle radiosensitization
Butterworth, K. T., McMahon, S. J., Currell, F. J., & Prise, K. M. (2012) · Nanoscale · doi:10.1039/c2nr31227a · Cited by 478
Gold Nanoparticle Imaging and Radiotherapy of Brain Tumors in Mice
Hainfeld, J. F., Smilowitz, H. M., O‘Connor, M. J., Dilmanian, F. A., & Slatkin, D. N. (2013) · Nanomedicine · doi:10.2217/nnm.12.165 · Cited by 430
Self-citationGold Nanoparticles as Contrast Agents in x-ray Imaging and Computed Tomography
Cole, L. E., Ross, R. D., Tilley, J. M., Vargo-Gogola, T., & Roeder, R. K. (2015) · Nanomedicine · doi:10.2217/nnm.14.171 · Cited by 356
Yang, W., Liang, H., Ma, S., Wang, D., & Huang, J. (2019) · Sustainable Materials and Technologies · doi:10.1016/j.susmat.2019.e00109 · Cited by 329
Plasmonic gold nanoparticles: Optical manipulation, imaging, drug delivery and therapy
Sharifi, M., Attar, F., Saboury, A. A., Akhtari, K., Hooshmand, N., Hasan, A., El-Sayed, M. A., & Falahati, M. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.08.032 · Cited by 307
Targeted gold nanoparticles enable molecular CT imaging of cancer: an in vivo study
Popovtzer, R., Reuveni, Motiei, Romman, & Popovtzer (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s25446 · Cited by 285
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Intravenous magnetic nanoparticle cancer hyperthermia
Hainfeld, J., & Huang (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s43770 · Cited by 245
“…the resulting distribution of nanoparticles is not uniform throughout the tumor after IV administration, it leads to thorough tumor encasement, 53,54 which can cut off blood supply (oxygen and nutrients) to central hypoxic regions, compared with direct injections that are punctate and can…”
Self-citationNanoparticles as Computed Tomography Contrast Agents: Current Status and Future Perspectives
Shilo, M., Reuveni, T., Motiei, M., & Popovtzer, R. (2012) · Nanomedicine · doi:10.2217/nnm.11.190 · Cited by 238
Nanoparticles in practice for molecular-imaging applications: An overview
Padmanabhan, P., Kumar, A., Kumar, S., Chaudhary, R. K., & Gulyás, B. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.06.003 · Cited by 238
Transport of nanoparticles through the blood–brain barrier for imaging and therapeutic applications
Shilo, M., Motiei, M., Hana, P., & Popovtzer, R. (2014) · Nanoscale · doi:10.1039/c3nr04878k · Cited by 193
Inorganic Nanoparticles Based Contrast Agents for X‐ray Computed Tomography
Jakhmola, A., Anton, N., & Vandamme, T. F. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200032 · Cited by 184
Ganeshkumar, M., Sathishkumar, M., Ponrasu, T., Dinesh, M. G., & Suguna, L. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2013.01.035 · Cited by 172
Semmler-Behnke, M., Lipka, J., Wenk, A., Hirn, S., Schäffler, M., Tian, F., Schmid, G., Oberdörster, G., & Kreyling, W. G. (2014) · Particle and Fibre Toxicology · doi:10.1186/s12989-014-0033-9 · Cited by 135
Metadata
- Authors
- Hainfeld, J. F., O’Connor, M. J., Dilmanian, F. A., Slatkin, D. N., Adams, D. J., & Smilowitz, H. M.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-06
- Volume
- 84
- Issue
- 1002
- Pages
- 526-533
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1992483135
- Cited by
- 246
- References
- 2
- FWCI
- 18.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.