The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Global Estimates of Ambient Fine Particulate Matter Concentrations from Satellite-Based Aerosol Optical Depth: Development and Application
Open accessAbstract
BACKGROUND: Epidemiologic and health impact studies of fine particulate matter with diameter < 2.5 microm (PM2.5) are limited by the lack of monitoring data, especially in developing countries. Satellite observations offer valuable global information about PM2.5 concentrations. OBJECTIVE: In this study, we developed a technique for estimating surface PM2.5 concentrations from satellite observations. METHODS: We mapped global ground-level PM2.5 concentrations using total column aerosol optical depth (AOD) from the MODIS (Moderate Resolution Imaging Spectroradiometer) and MISR (Multiangle Imaging Spectroradiometer) satellite instruments and coincident aerosol vertical profiles from the GEOS-Chem global chemical transport model. RESULTS: We determined that global estimates of long-term average (1 January 2001 to 31 December 2006) PM2.5 concentrations at approximately 10 km x 10 km resolution indicate a global population-weighted geometric mean PM2.5 concentration of 20 microg/m3. The World Health Organization Air Quality PM2.5 Interim Target-1 (35 microg/m3 annual average) is exceeded over central and eastern Asia for 38% and for 50% of the population, respectively. Annual mean PM2.5 concentrations exceed 80 microg/m3 over eastern China. Our evaluation of the satellite-derived estimate with ground-based in situ measurements indicates significant spatial agreement with North American measurements (r = 0.77; slope = 1.07; n = 1057) and with noncoincident measurements elsewhere (r = 0.83; slope = 0.86; n = 244). The 1 SD of uncertainty in the satellite-derived PM2.5 is 25%, which is inferred from the AOD retrieval and from aerosol vertical profile errors and sampling. The global population-weighted mean uncertainty is 6.7 microg/m3. CONCLUSIONS: Satellite-derived total-column AOD, when combined with a chemical transport model, provides estimates of global long-term average PM2.5 concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Interannual variability in global biomass burning emissions from 1997 to 2004
van der Werf, G. R., Randerson, J. T., Giglio, L., Collatz, G. J., Kasibhatla, P. S., & Arellano, A. F. (2006) · Atmospheric Chemistry and Physics · doi:10.5194/acp-6-3423-2006 · Cited by 1,656
Wong, C.-M., Vichit-Vadakan, N., Kan, H., & Qian, Z. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.11257 · Cited by 476
Research works printed but not linked: 38
- Beelen, 2008, Long-term effects of traffic-related air pollution on mortality in a Dutch cohort (NLCS-Air Study), Environ Health Perspect, 116, 196, 10.1289/ehp.10767 · DOI · Paper page
- Chen, 2006, Development of a multiple objective planning theory and system for sustainable air quality monitoring networks, Sci Total Environ, 354, 1, 10.1016/j.scitotenv.2005.08.018 · DOI
- Cohen, 2004, Mortality impacts of urban air pollution
- Di Girolamo, 2004, Analysis of Multi-Angle Imaging Spectroradiometer (MISR) aerosol optical depths over greater India during winter 2001–2004, Geophys Res Lett, 31, L23115, 10.1029/2004GL021273 · doi:10.1029/2004gl021273
- Diner, 1998, Multiangle Imaging SpectroRadiometer (MISR) instrument description and experiment overview, IEEE Trans Geosci Rem Sens, 36, 1072, 10.1109/36.700992 · DOI · Paper page
- Diner, 2005, The value of multiangle measurements for retrieving structurally and radiatively consistent properties of clouds, aerosols, and surfaces, Remote Sens Environ, 97, 495, 10.1016/j.rse.2005.06.006 · DOI
- Drury, 2008, Improved algorithm for MODIS satellite retrievals of aerosol optical depths over western North America, J Geophys Res, 113, D16204, 10.1029/2007JD009573 · DOI
- Engel-Cox, 2004, Recommendations on the use of satellite remote-sensing data for urban air quality, J Air Waste Manage Assoc, 54, 1360, 10.1080/10473289.2004.10471005 · DOI
- Engel-Cox, 2006, Integrating lidar and satellite optical depth with ambient monitoring for 3-dimensional particulate characterization, Atmos Environ, 40, 8056, 10.1016/j.atmosenv.2006.02.039 · DOI
- Engel-Cox, 2004, Qualitative and quantitative evaluation of MODIS satellite sensor data for regional and urban scale air quality, Atmos Environ, 38, 2495, 10.1016/j.atmosenv.2004.01.039 · DOI · Paper page
- Gupta, 2006, Satellite remote sensing of particulate matter and air quality assessment over global cities, Atmos Environ, 40, 5880, 10.1016/j.atmosenv.2006.03.016 · DOI · Paper page
- Hirsh, 1984, Methods of fitting a straight line to data: examples in water resources, J Am Water Resour Assoc, 20, 705, 10.1111/j.1752-1688.1984.tb04753.x · DOI
- Hoff, 2009, Remote sensing of particulate pollution from space: have we reached the promised land?, J Air Waste Manag Assoc, 59, 645, 10.3155/1047-3289.59.6.645 · DOI · Paper page
- Hu, 2009, Spatial analysis of MODIS aerosol optical depth, PM2.5 and chronic coronary heart disease, Int J Health Geogr, 8, 27, 10.1186/1476-072X-8-27 · DOI
- Jones, 2007, MODIS derived fine mode fraction characteristics of marine, dust, and anthropogenic aerosols over the ocean, constrained by GOCART, MOPITT, and TOMS, J Geophys Res, 112, D22204, 10.1029/2007JD008974 · doi:10.1029/2007jd008974
- Kahn, 2007, Aerosol source plume physical characteristics from space-based multiangle imaging, J Geophys Res, 112, D11205, 10.1029/2006JD007647 · DOI · Paper page
- Koelemeijer, 2006, Comparison of spatial and temporal variations of aerosol optical thickness and particulate matter over Europe, Atmos Environ, 40, 5304, 10.1016/j.atmosenv.2006.04.044 · DOI · Paper page
- Künzli, 2001, Assessment of deaths attributable to air pollution: should we use risk estimates based on time series or on cohort studies?, Am J Epidemiol, 153, 1050, 10.1093/aje/153.11.1050 · DOI · Paper page
- Lamsal, 2008, Ground-level nitrogen dioxide concentrations inferred from the satellite-borne ozone monitoring instrument, J Geophys Res, 113, 16308, 10.1029/2007JD009235 · DOI · Paper page
- Levy, 2009, A critical look at deriving monthly aerosol optical depth from satellite data, IEEE Trans Geosci Remote Sens, 47, 2942, 10.1109/TGRS.2009.2013842 · doi:10.1109/tgrs.2009.2013842
- Levy, 2007, Second-generation operational algorithm: retrieval of aerosol properties over land from inversion of moderate resolution imaging spectroradiometer spectral reflectance, J Geophys Res, 112, 13211, 10.1029/2006JD007811 · DOI · Paper page
- Liu, 2007, Estimating fine particulate matter component concentrations and size distribution using satellite-retrieved fractional aerosol optical depth: Part 1 – method development, J Air Waste Manage Assoc, 57, 1351, 10.3155/1047-3289.57.11.1351 · doi:10.3155/1047-3289.57.11.1351
- Liu, 2004, Mapping annual mean ground-level PM2.5 concentrations using multiangle imaging spectroradiometer aerosol optical thickness over the contiguous United States, J Geophys Res, 109, 22206, 10.1029/2004JD005025 · DOI · Paper page
- Liu, 2005, Estimating ground-level PM2.5 in the eastern United States using satellite remote sensing, Environ Sci Technol, 39, 3269, 10.1021/es049352m · DOI · Paper page
- Martin, 2008, Satellite remote sensing of surface air quality, Atmos Environ, 42, 7823, 10.1016/j.atmosenv.2008.07.018 · DOI · Paper page
- Martonchik, 2009, Retrieval of aerosol properties over land using MISR observations, 267, 10.1007/978-3-540-69397-0_9 · DOI · Paper page
- McDonnell, 2000, Relationships of mortality with the fine and coarse fractions of long-term ambient PM10 concentrations in nonsmokers, J Expos Anal Environ Epidemiol, 10, 427, 10.1038/sj.jea.7500095 · DOI · Paper page
- Paciorek, 2009, Limitations of remotely-sensed aerosol as a spatial proxy for fine particulate matter, Environ Health Perspect, 117, 904, 10.1289/ehp.0800360 · DOI
- Pope, 2002, Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution, JAMA, 287, 1132, 10.1001/jama.287.9.1132 · DOI · Paper page
- Pope, 2009, Fine-particulate air pollution and life expectancy in the United States, N Engl J Med, 360, 376, 10.1056/NEJMsa0805646 · DOI · Paper page
- Prospero, 2002, Environmental characterization of global sources of atmospheric soil dust identified with the nimbus 7 Total Ozone Mapping Spectrometer (TOMS) absorbing aerosol product, Rev Geophys, 40, 1002, 10.1029/2000RG000095 · DOI · Paper page
- Schaaf, 2002, First operation BRDF, albedo nadir relectance products from MODIS, Remote Sens Environ, 83, 135, 10.1016/S0034-4257(02)00091-3 · DOI · Paper page
- Schaap, 2009, Exploring the relation between aerosol optical depth and PM2.5 at Cabauw, the Netherlands, Atmos Chem Phys, 9, 909, 10.5194/acp-9-909-2009 · DOI · Paper page
- Tobler, 1997, World population in a grid of spherical quadrilaterals, Int J Popul Geogr, 3, 203, 10.1002/(SICI)1099-1220(199709)3:3<203::AID-IJPG68>3.0.CO;2-C · doi:10.1002/(sici)1099-1220(199709)3:3<203::aid-ijpg68>3.0.co;2-c
- van Donkelaar, 2006, Estimating ground-level PM2.5 using aerosol optical depth determined from satellite remote sensing, J Geophys Res, 111, 21201, 10.1029/2005JD006996 · DOI · Paper page
- Wang, 2003, Intercomparison between satellite-derived aerosol optical thickness and PM2.5 mass: implications for air quality studies, Geophys Res Lett, 30, 2095, 10.1029/2003GL018174 · DOI · Paper page
- WHO (World Health Organization), 2005, Air Quality Guidelines Global Update 2005
- Winkler, 2007, Initial performance assessment of CALIOP, Geophys Res Lett, 34, L19803, 10.1029/2007GL030135 · DOI · Paper page
Cited by
Lim, S. S., Vos, T., Flaxman, A. D., Danaei, G., Shibuya, K., Adair-Rohani, H., AlMazroa, M. A., Amann, M., Anderson, H. R., Andrews, K. G., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61766-8 · Cited by 11,805
Self-citationThe contribution of outdoor air pollution sources to premature mortality on a global scale
Lelieveld, J., Evans, J. S., Fnais, M., Giannadaki, D., & Pozzer, A. (2015) · Nature · doi:10.1038/nature15371 · Cited by 5,977
Fine particulate matter (PM2.5) in China at a city level
Zhang, Y.-L., & Cao, F. (2015) · Scientific Reports · doi:10.1038/srep14884 · Cited by 921
van Donkelaar, A., Martin, R. V., Brauer, M., & Boys, B. L. (2015) · Environmental Health Perspectives · doi:10.1289/ehp.1408646 · Cited by 894
Self-citationEstimated Global Mortality Attributable to Smoke from Landscape Fires
Johnston, F. H., Henderson, S. B., Chen, Y., Randerson, J. T., Marlier, M., DeFries, R. S., Kinney, P., Bowman, D. M. J. S., & Brauer, M. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104422 · Cited by 852
Self-citation
Metadata
- Authors
- van Donkelaar, A., Martin, R. V., Brauer, M., Kahn, R., Levy, R., Verduzco, C., & Villeneuve, P. J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06
- Volume
- 118
- Issue
- 6
- Pages
- 847-855
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- OpenAlex
- W2069977802
- Cited by
- 1,623
- References
- 3
- FWCI
- 53.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Global Estimates of Ambient Fine Particulate Matter Concentrations from Satellite-Based Aerosol Optical Depth: Development and Application. https://app.cochat.ai/papers/10.1289/ehp.0901623
- The paper
- van Donkelaar, A., Martin, R. V., Brauer, M., Kahn, R., Levy, R., Verduzco, C., & Villeneuve, P. J. (2010). Global Estimates of Ambient Fine Particulate Matter Concentrations from Satellite-Based Aerosol Optical Depth: Development and Application. Environmental Health Perspectives. https://doi.org/10.1289/ehp.0901623
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.