The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Measurement of optical properties of biological tissues by low-coherence reflectometry
Abstract
We show that optical properties of dense biological tissues can be determined from backscattered power curves measured by a low-coherence reflectometer. Our measurement approach is based on a first-order scattering theory that relates the backscattered power to the total and backscattering cross sections of scatterers in a turbid medium. As a validation of the technique, measurements were made with a commercially available reflectometer on suspensions of polystyrene microspheres having known optical properties. With this reflectometer, which employs a 1300-nm LED source that emits less than 20 µW, we found that skin tissues could be probed to a depth of nearly 1 mm. Estimates of optical coefficients of human dermis and of a variety of excised animal tissues are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Refractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Optical properties of normal and diseased human breast tissues in the visible and near infrared
Peters, V. G., Wyman, D. R., Patterson, M. S., & Frank, G. L. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/010 · Cited by 414
Takada, K., Yokohama, I., Chida, K., & Noda, J. (1987) · Applied Optics · doi:10.1364/ao.26.001603 · Cited by 371
Use of polarized light to discriminate short-path photons in a multiply scattering medium
Schmitt, J. M., Gandjbakhche, A. H., & Bonner, R. F. (1992) · Applied Optics · doi:10.1364/ao.31.006535 · Cited by 292
Self-citationThe thickness of the epidermis
WHITTON, J. T., & EVERALL, J. D. (1973) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1973.tb03007.x · Cited by 271
Diffusing-wave spectroscopy and multiple scattering of light in correlated random media
MacKintosh, F. C., & John, S. (1989) · Physical Review B · doi:10.1103/physrevb.40.2383 · Cited by 238
Extinction and absorption coefficients and scattering phase functions of human tissues in vitro
Marchesini, R., Bertoni, A., Andreola, S., Melloni, E., & Sichirollo, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002318 · Cited by 225
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1987) · Medical Physics · doi:10.1118/1.596010 · Cited by 212
Sigelmann, R. A., & Reid, J. M. (1973) · The Journal of the Acoustical Society of America · doi:10.1121/1.1913479 · Cited by 191
Optical properties of rat liver between 350 and 2200 nm
Parsa, P., Jacques, S. L., & Nishioka, N. S. (1989) · Applied Optics · doi:10.1364/ao.28.002325 · Cited by 176
Yoo, K. M., Xing, Q., & Alfano, R. R. (1991) · Optics Letters · doi:10.1364/ol.16.001019 · Cited by 164
Micron‐resolution ranging of cornea anterior chamber by optical reflectometry
Huang, D., Wang, J., Lin, C. P., Puliafito, C. A., & Fujimoto, J. G. (1991) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900110506 · Cited by 153
INDIRECT VERSUS DIRECT TECHNIQUES FOR THE MEASUREMENT OF THE OPTICAL PROPERTIES OF TISSUES
Wilson, B. C., Patterson, M. S., & Flock, S. T. (1987) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1987.tb04820.x · Cited by 101
Applications of the 1-D diffusion approximation to the optics of tissues and tissue phantoms
Karagiannes, J. L., Zhang, Z., Grossweiner, B., & Grossweiner, L. I. (1989) · Applied Optics · doi:10.1364/ao.28.002311 · Cited by 85
Toida, M., Kondō, M., Ichimura, T., & Inaba, H. (1991) · Applied Physics B · doi:10.1007/bf00325156 · Cited by 68
Yoo, K. M., & Alfano, R. R. (1990) · Optics Letters · doi:10.1364/ol.15.000276 · Cited by 25
Cited by
Gold Nanocages: Bioconjugation and Their Potential Use as Optical Imaging Contrast Agents
Chen, J., Saeki, F., Wiley, B. J., Cang, H., Cobb, M. J., Li, Z.-Y., Au, L., Zhang, H., Kimmey, M. B., Li, X., et al. (2005) · Nano Letters · doi:10.1021/nl047950t · Cited by 977
Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Metadata
- Authors
- Schmitt, J. M., Knüttel, A., & Bonner, R. F.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1993-10-20
- Volume
- 32
- Issue
- 30
- Pages
- 6032
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2092668319
- Cited by
- 355
- References
- 20
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.