The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms
Abstract
Predictions from Mie theory regarding the wavelength dependence of scattering in tissue from the near UV to the near IR are discussed and compared with experiments on tissue phantoms. For large fiber separations it is shown that rapid, simultaneous measurements of the elastic scatter signal for several fiber separations can yield the absorption coefficient and reduced scattering coefficient. With this information, the size of the scattering particles can be estimated, and this is done for Intralipid. Measurements made at smaller source detector separations support Mie theory calculations, demonstrating that the sensitivity of elastic scatter measurements to morphological features, such as scatterer size, is enhanced when the distance between the source and detector fibers is small.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Geigy, J. R. (1981) · Medical Entomology and Zoology · Cited by 1,221
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Optical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Ultraviolet laser‐induced fluorescence of colonic tissue: Basic biology and diagnostic potential
Schomacker, K. T., Frisoli, J. K., Compton, C. C., Flotte, T. J., Richter, J. M., Nishioka, N. S., & Deutsch, T. F. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120111 · Cited by 416
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Analytical model for extracting intrinsic fluorescence in turbid media
Wu, J., Feld, M. S., & Rava, R. P. (1993) · Applied Optics · doi:10.1364/ao.32.003585 · Cited by 299
Fantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E. (1994) · Applied Optics · doi:10.1364/ao.33.005204 · Cited by 259
Ramanujam, N., Mitchell, M. F., Mahadevan, A., Warren, S., Thomsen, S., Silva, E., & Richards-Kortum, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10193 · Cited by 253
Spectroscopic diagnosis of bladder cancer with elastic light scattering
Mourant, J. R., Bigio, I. J., Boyer, J., Conn, R. L., Johnson, T., & Shimada, T. (1995) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900170403 · Cited by 250
Self-citationGraaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Properties of photon density waves in multiple-scattering media
Tromberg, B. J., Svaasand, L. O., Tsay, T.-T., & Haskell, R. C. (1993) · Applied Optics · doi:10.1364/ao.32.000607 · Cited by 225
Determination of optical properties and blood oxygenation in tissue using continuous NIR light
Liu, H., Boas, D. A., Zhang, Y., Yodh, A. G., & Chance, B. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/11/015 · Cited by 167
Patterson, M. S., Andersson‐Engels, S., Wilson, B. C., & Osei, E. K. (1995) · Applied Optics · doi:10.1364/ao.34.000022 · Cited by 153
Meyer, R. A. (1979) · Applied Optics · doi:10.1364/ao.18.000585 · Cited by 146
Fishkin, J. B., So, P. T. C., Cerussi, A. E., Fantini, S., Franceschini, M. A., & Gratton, E. (1995) · Applied Optics · doi:10.1364/ao.34.001143 · Cited by 96
Clinical determination of tissue optical properties by endoscopic spatially resolved reflectometry
Bays, R., Wagnières, G., Robert, D., Braichotte, D. R., Savary, J., Monnier, P., & van den Bergh, H. (1996) · Applied Optics · doi:10.1364/ao.35.001756 · Cited by 89
Beauvoit, B. P., Liu, H., Kang, K. A., Kaplan, P. D., Miwa, M., & Chance, B. (1993) · Cell Biophysics · doi:10.1007/bf02796508 · Cited by 62
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Self-citationShuhendler, A. J., Pu, K., Cui, L., Uetrecht, J. P., & Rao, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2838 · Cited by 623
Selection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Metadata
- Authors
- Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1997-02-01
- Volume
- 36
- Issue
- 4
- Pages
- 949
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1985741844
- Cited by
- 529
- References
- 21
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.