Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Predictions from Mie theory regarding the wavelength dependence of scattering in tissue from the near UV to the near IR are discussed and compared with experiments on tissue phantoms. For large fiber separations it is shown that rapid, simultaneous measurements of the elastic scatter signal for several fiber separations can yield the absorption coefficient and reduced scattering coefficient. With this information, the size of the scattering particles can be estimated, and this is done for Intralipid. Measurements made at smaller source detector separations support Mie theory calculations, demonstrating that the sensitivity of elastic scatter measurements to morphological features, such as scatterer size, is enhanced when the distance between the source and detector fibers is small.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Geigy, J. R. (1981) · Medical Entomology and Zoology · Cited by 1,221
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Optical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Ultraviolet laser‐induced fluorescence of colonic tissue: Basic biology and diagnostic potential
Schomacker, K. T., Frisoli, J. K., Compton, C. C., Flotte, T. J., Richter, J. M., Nishioka, N. S., & Deutsch, T. F. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120111 · Cited by 416
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Analytical model for extracting intrinsic fluorescence in turbid media
Wu, J., Feld, M. S., & Rava, R. P. (1993) · Applied Optics · doi:10.1364/ao.32.003585 · Cited by 299
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Self-citationShuhendler, A. J., Pu, K., Cui, L., Uetrecht, J. P., & Rao, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2838 · Cited by 623
Selection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Perelman, L. T., Backman, V., Wallace, M., Zonios, G., Manoharan, R., Nusrat, A., Shields, S., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 491
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
“The values presented can only be as good as the diffusion model, and rely upon a wavelength dependence determined from phantom measurements.(84) The absorption coefficients from both Graaf et al.”
MethodFiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Black, K. C. L., Wang, Y., Luehmann, H. P., Cai, X., Xing, W., Pang, B., Zhao, Y., Cutler, C. S., Wang, L. V., Liu, Y., et al. (2014) · ACS Nano · doi:10.1021/nn406258m · Cited by 365
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Bulk optical properties of healthy female breast tissue
Durduran, T., Choe, R., Culver, J. P., Zubkov, L., Holboke, M. J., Giammarco, J., Chance, B., & Yodh, A. G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/302 · Cited by 291
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results
Bigio, I. J., Bown, S. G., Briggs, G., Kelley, C., Lakhani, S., Pickard, D., Ripley, P. M., Rose, I. G., & Saunders, C. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429990 · Cited by 279
Self-citationDiffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Srinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C., Soho, S., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2032822100 · Cited by 267
Chromophore concentrations, absorption and scattering properties of human skin in-vivo
Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N. (2009) · Optics Express · doi:10.1364/oe.17.014599 · Cited by 217
“[20] From the Monte Carlo study, we understand that the diffusing probe has a much more superficial interrogation volume at short wavelengths than at long wavelengths.”
Diffuse backscattering Mueller matricesof highly scattering media
Hielscher, A., Eick, A., Mourant, J., Shen, D., Freyer, J., & Bigio, I. (1997) · Optics Express · doi:10.1364/oe.1.000441 · Cited by 183
Self-citationIn vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy
Tseng, S.-H., Grant, A., & Durkin, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2829772 · Cited by 139
Non-invasive investigation of adipose tissue by time domain diffuse optical spectroscopy
Lanka, P., Segala, A., Farina, A., Konugolu Venkata Sekar, S., Nisoli, E., Valerio, A., Taroni, P., Cubeddu, R., & Pifferi, A. (2020) · Biomedical Optics Express · doi:10.1364/boe.391028 · Cited by 39
Metadata
- Authors
- Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1997-02-01
- Volume
- 36
- Issue
- 4
- Pages
- 949
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1985741844
- Cited by
- 529
- References
- 21
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.