The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Noninvasive determination of the optical properties of two-layered turbid media
Open accessAbstract
Light propagation in two-layered turbid media having an infinitely thick second layer is investigated in the steady-state, frequency, and time domains. A solution of the diffusion approximation to the transport equation is derived by employing the extrapolated boundary condition. We compare the reflectance calculated from this solution with that computed with Monte Carlo simulations and show good agreement. To investigate if it is possible to determine the optical coefficients of the two layers and the thickness of the first layer, the solution of the diffusion equation is fitted to reflectance data obtained from both the diffusion equation and the Monte Carlo simulations. Although it is found that it is, in principle, possible to derive the optical coefficients of the two layers and the thickness of the first layer, we concentrate on the determination of the optical coefficients, knowing the thickness of the first layer. In the frequency domain, for example, it is shown that it is sufficient to make relative measurements of the phase and the steady-state reflectance at three distances from the illumination point to obtain useful estimates of the optical coefficients. Measurements of the absolute steady-state spatially resolved reflectance performed on two-layered solid phantoms confirm the theoretical results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Self-citationBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Self-citationKienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Self-citationFrequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Fantini, S. (1995) · Optical Engineering · doi:10.1117/12.183988 · Cited by 330
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Multilayer model of photon diffusion in skin
Schmitt, J. M., Wall, R. T., Zhou, G. X., & Walker, E. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002141 · Cited by 204
Condensed Monte Carlo simulations for the description of light transport
Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993) · Applied Optics · doi:10.1364/ao.32.000426 · Cited by 184
Determination of the optical properties of turbid media from a single Monte Carlo simulation
Kienle, A., & Patterson, M. S. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/10/026 · Cited by 183
Self-citationOptical diffusion in layered media
Keijzer, M., Star, W. M., & Storchi, P. R. M. (1988) · Applied Optics · doi:10.1364/ao.27.001820 · Cited by 183
Bruulsema, J. T., Hayward, J. E., Farrell, T. J., Patterson, M. S., Heinemann, L., Berger, M., Koschinsky, T., Sandahl-Christiansen, J., Ørskov, H., Essenpreis, M., et al. (1997) · Optics Letters · doi:10.1364/ol.22.000190 · Cited by 156
Self-citationHomma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123
The effect of overlying tissue on the spatial sensitivity profile of near-infrared spectroscopy
Okada, E., Firbank, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/007 · Cited by 106
Photon migration in layered media
Nossal, R., Kiefer, J. E., Weiss, G. H., Bonner, R. F., Taitelbaum, H., & Havlin, S. (1988) · Applied Optics · doi:10.1364/ao.27.003382 · Cited by 95
Cui, W., & Ostrander, L. E. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121651 · Cited by 64
Photon Migration in a Two-layer Turbid Medium a Diffusion Analysis
Dayan, I., Havlin, S., & Weiss, G. H. (1992) · Journal of Modern Optics · doi:10.1080/09500349214551581 · Cited by 58
A new optimal wavelength for treatment of port wine stains?
Kienle, A., & Hibst, R. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/10/001 · Cited by 54
Self-citationError assessment of a wavelength tunable frequency domain system for noninvasive tissue spectroscopy
Pogue, B. W., & Patterson, M. S. (1996) · Journal of Biomedical Optics · doi:10.1117/12.240679 · Cited by 33
Self-citationControlled temperature tissue fusion: Ho:YAG laser welding of rat intestine in vivo, Part Two
Çilesiz, I. F., Thomsen, S., Welch, A. J., & Chan, E. K. Y. (1997) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1997)21:3<227::aid-lsm2>3.0.co;2-s · Cited by 30
Cited by
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Determining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
Chromophore concentrations, absorption and scattering properties of human skin in-vivo
Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N. (2009) · Optics Express · doi:10.1364/oe.17.014599 · Cited by 217
Metadata
- Authors
- Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1998-02-01
- Volume
- 37
- Issue
- 4
- Pages
- 779
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2070125833
- Cited by
- 294
- References
- 25
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.