Sensitive disk resonator photonic biosensor
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We describe a photonic device based on a high-finesse, whispering-gallery-mode disk resonator that can be used for the detection of biological pathogens. This device operates by means of monitoring the change in transfer characteristics of the disk resonator when biological materials fall onto its active area. High sensitivity is achieved because the light wave interacts many times with each pathogen as a consequence of the resonant recirculation of light within the disk structure. Specificity of the detected substance can be achieved when a layer of antibodies or other binding material is deposited onto the active area of the resonator. Formulas are presented that allow the sensitivity of the device to be quantified and that show that, under optimum conditions, as few as 100 molecules can be detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008
Computational Electrodynamics: The Finite-Difference Time-Domain Method
Taflove, A. (1995) · Cited by 10,626
Microring resonator channel dropping filters
Little, B. E., Chu, S. T., Haus, H. A., Foresi, J., & Laine, J.-P. (1997) · Journal of Lightwave Technology · doi:10.1109/50.588673 · Cited by 1,679
Whispering-gallery mode microdisk lasers
McCall, S. L., Levi, A. F. J., Slusher, R. E., Pearton, S. J., & Logan, R. A. (1992) · Applied Physics Letters · doi:10.1063/1.106688 · Cited by 1,446
Ultimate Q of optical microsphere resonators
Gorodetsky, M. L., Savchenkov, A. A., & Ilchenko, V. S. (1996) · Optics Letters · doi:10.1364/ol.21.000453 · Cited by 1,035
Cai, M., Painter, O., & Vahala, K. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.74 · Cited by 912
Quality-factor and nonlinear properties of optical whispering-gallery modes
Braginsky, V. B., Gorodetsky, M. L., & Ilchenko, V. S. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90912-2 · Cited by 768
Optical Processes in Microcavities
Yamamoto, Y., & Slusher, R. E. (1993) · Physics Today · doi:10.1063/1.881356 · Cited by 561
High-Q measurements of fused-silica microspheres in the near infrared
Vernooy, D. W., Ilchenko, V. S., Mabuchi, H., Streed, E. W., & Kimble, H. J. (1998) · Optics Letters · doi:10.1364/ol.23.000247 · Cited by 502
Biological Warfare: A Historical Perspective
Christopher, L. G. W. (1997) · JAMA · doi:10.1001/jama.1997.03550050074036 · Cited by 417
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Whispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
Label-Free, Single-Molecule Detection with Optical Microcavities
Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007) · Science · doi:10.1126/science.1145002 · Cited by 1,141
Integrated optofluidics: A new river of light
Monat, C., Domachuk, P., & Eggleton, B. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.96 · Cited by 955
Recent progress in nanoimprint technology and its applications
Guo, L. J. (2004) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/37/11/r01 · Cited by 733
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Optical resonators with whispering-gallery modes-part II: applications
Ilchenko, V. S., & Matsko, A. B. (2006) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.862943 · Cited by 591
Iqbal, M., Gleeson, M. A., Spaugh, B., Tybor, F., Gunn, W. G., Hochberg, M., Baehr-Jones, T., Bailey, R. C., & Gunn, L. C. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2032510 · Cited by 551
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Biochemical sensors based on polymer microrings with sharp asymmetrical resonance
Chao, C.-Y., & Guo, L. J. (2003) · Applied Physics Letters · doi:10.1063/1.1605261 · Cited by 470
Polymer microring resonators for biochemical sensing applications
Chao, C.-Y., Fung, W., & Guo, L. J. (2006) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.862945 · Cited by 442
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Optical sensing of biomolecules using microring resonators
Yalcin, A., Popat, K. C., Aldridge, J. C., Desai, T. A., Hryniewicz, J., Chbouki, N., Little, B. E., King, O., Van, V., Chu, S., et al. (2006) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.863003 · Cited by 377
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Washburn, A. L., Gunn, L. C., & Bailey, R. C. (2009) · Analytical Chemistry · doi:10.1021/ac902006p · Cited by 318
High-Q Optical Sensors for Chemical and Biological Analysis
Luchansky, M. S., & Bailey, R. C. (2012) · Analytical Chemistry · doi:10.1021/ac2029024 · Cited by 288
Progress of new label-free techniques for biosensors: a review
Sang, S., Wang, Y., Feng, Q., Wei, Y., Ji, J., & Zhang, W. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.991270 · Cited by 272
Optical transmission characteristics of fiber ring resonators
Heebner, J. E., Wong, V., Schweinsberg, A., Boyd, R. W., & Jackson, D. J. (2004) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.2004.828232 · Cited by 259
Self-citationHeavy water detection using ultra-high-Q microcavities
Armani, A. M., & Vahala, K. J. (2006) · Optics Letters · doi:10.1364/ol.31.001896 · Cited by 254
Whispering-gallery-mode electro-optic modulator and photonic microwave receiver
Ilchenko, V. S., Savchenkov, A. A., Matsko, A. B., & Maleki, L. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.000333 · Cited by 177
Metadata
- Authors
- Boyd, R. W., & Heebner, J. E.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2001-11-01
- Volume
- 40
- Issue
- 31
- Pages
- 5742
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1975760653
- Cited by
- 399
- References
- 21
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.