Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The concept of refractive-index matching to enhance the optical penetration depth of whole blood is discussed on the basis of in vitro studies that used the technique of near-infrared optical coherence tomography. It was found that optical clearing of blood is defined not only by refractive-index matching but also by changes in the size of red blood cells and in their aggregation ability when chemicals are added. For example, in whole blood diluted to twice its volume by saline with the addition of 6.5% glycerol, the total attenuation coefficient was reduced from 4.2 to 2.0 mm(-1), and the optical penetration at 820 nm was correspondingly increased to 117%. For the other agents tested (glucose, dextrans, propylene glycol, and trazograph) the enhancement of penetration was 20-150.5%. In the blood sedimentation study, regular or irregular oscillations or jumps of the red-blood cell-plasma boundary were observed. The 1-min time period of regular oscillations correlated well with the kinetics of the aggregation process as described by the two subsequent stages of formation of linear and three-dimensional aggregates. The results also showed that optical clearing of blood by osmotic agents is potentially useful not only in blood sedimentation and aggregation studies but also in intravascular optical coherence tomography imaging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819
Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Fercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
Light propagation in tissues with controlled optical properties
Tuchin, V. V. (1997) · Journal of Biomedical Optics · doi:10.1117/1.429841 · Cited by 411
Self-citationMaier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Use of an agent to reduce scattering in skin
Vargas, G., Chan, E. K., Barton, J. K., Rylander, H. G., & Welch, A. J. (1999) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1999)24:2<133::aid-lsm9>3.0.co;2-x · Cited by 302
High resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Knüttel, A., & Boehlau-Godau, M. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429972 · Cited by 235
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Tissue clearing and its applications in neuroscience
Ueda, H. R., Ertürk, A., Chung, K., Gradinaru, V., Chédotal, A., Tomancak, P., & Keller, P. J. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0250-1 · Cited by 609
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Optical clearing of tissues and blood using the immersion method
Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/001 · Cited by 232
Self-citationTissue optical immersion clearing
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.50 · Cited by 208
Self-citationZhang, A., Zhang, Q., & Wang, R. K. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004130 · Cited by 173
Self-citationWang, R. K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/13/307 · Cited by 159
Self-citationApplication of optical coherence tomography in clinical diagnosis
Wang, Y., Liu, S., Lou, S., Zhang, W., Cai, H., & Chen, X. (2019) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-190559 · Cited by 42
“And there are a serial of extensions of OCT which enrich the information of OCT images and have been put into use in clinic, such as polarization sensitive OCT (PS-OCT) [6], Doppler OCT [7], OCT angiography (OCTA) [8], dynamic OCT [9] and so on.”
Background
Metadata
- Authors
- Tuchin, V. V., Xu, X., & Wang, R. K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2002-01-01
- Volume
- 41
- Issue
- 1
- Pages
- 258
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2086128140
- Cited by
- 163
- References
- 21
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.