The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Abstract
After discussing the rationale and assumptions of the ANSI Z136.1-2000 Standard for protection of the human eye from laser exposure, we present the concise formulation of the exposure limits expressed as maximum permissible radiant exposure (in J/cm(2)) for light overfilling the pupil. We then translate the Standard to a form that is more practical for typical ophthalmic devices or in vision research situations, implementing the special qualifications of the Standard. The safety limits are then expressed as radiant power (watts) entering the pupil of the eye. Exposure by repetitive pulses is also addressed, as this is frequently employed in ophthalmic applications. Examples are given that will familiarize potential users with this format.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Color Science, Concepts and Methods. Quantitative Data and Formulas
Wright, W. D. (1967) · Physics Bulletin · doi:10.1088/0031-9112/18/10/010 · Cited by 3,540
(1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.10.1329 · Cited by 2,192
Safety with Lasers and Other Optical Sources: A Comprehensive Handbook
Sliney, D., & Wolbarsht, M. (1980) · Springer eBooks · doi:10.1007/978-1-4899-3596-0 · Cited by 618
Self-citationBressler, N. M. (2001) · Cited by 599
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Self-citationAging human RPE: morphometric analysis of macular, equatorial, and peripheral cells.
Feeney-Burns, L., Hilderbrand, E. S., & Eldridge, S. (1984) · PubMed · Cited by 561
International commission on non-ionizing radiation protection
Ziegelberger, G., Repacholi, M., & McKinlay, A. (2006) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.02.022 · Cited by 368
Webb, R. H., Hughes, G. W., & Pomerantzeff, O. (1980) · Applied Optics · doi:10.1364/ao.19.002991 · Cited by 272
Self-citationIn vivo fluorescence imaging of primate retinal ganglion cells and retinal pigment epithelial cells
Gray, D. C., Merigan, W., Wolfing, J. I., Gee, B. P., Porter, J., Dubra, A., Twietmeyer, T. H., Ahmad, K., Tumbar, R., Reinholz, F., et al. (2006) · Optics Express · doi:10.1364/oe.14.007144 · Cited by 178
Husain, D. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140186012 · Cited by 138
Cited by
The video head impulse test: Diagnostic accuracy in peripheral vestibulopathy
MacDougall, H. G., Weber, K. P., McGarvie, L. A., Halmagyi, G. M., & Curthoys, I. S. (2009) · Neurology · doi:10.1212/wnl.0b013e3181bacf85 · Cited by 793
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 467
Light-emitting diodes (LED) for domestic lighting: Any risks for the eye?
Behar-Cohen, F., Martinsons, C., Viénot, F., Zissis, G., Barlier-Salsi, A., Cesarini, J. P., Enouf, O., Garcia, M., Picaud, S., & Attia, D. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.04.002 · Cited by 416
In Vivo Imaging of Human Cone Photoreceptor Inner Segments
Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14542 · Cited by 380
Sutureless repair of corneal injuries using naturally derived bioadhesive hydrogels
Shirzaei Sani, E., Kheirkhah, A., Rana, D., Sun, Z., Foulsham, W., Sheikhi, A., Khademhosseini, A., Dana, R., & Annabi, N. (2019) · Science Advances · doi:10.1126/sciadv.aav1281 · Cited by 366
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T., Mathieson, K., Huie, P., Harris, J., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 351
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 331
A Review and Perspective on Optical Phased Array for Automotive LiDAR
Hsu, C.-P., Li, B., Solano-Rivas, B., Gohil, A. R., Chan, P. H., Moore, A. D., & Donzella, V. (2021) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2020.3022948 · Cited by 314
Impulsive Testing of Semicircular‐Canal Function Using Video‐oculography
Weber, K. P., MacDougall, H. G., Halmagyi, G. M., & Curthoys, I. S. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.03730.x · Cited by 306
Panwar, N., Huang, P., Lee, J., Keane, P. A., Chuan, T. S., Richhariya, A., Teoh, S., Lim, T. H., & Agrawal, R. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0068 · Cited by 293
Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence Tomography
Palanker, D. V., Blumenkranz, M. S., Andersen, D., Wiltberger, M., Marcellino, G., Gooding, P., Angeley, D., Schuele, G., Woodley, B., Simoneau, M., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001305 · Cited by 277
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Gibbs, D., Cideciyan, A. V., Jacobson, S. G., & Williams, D. S. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3471 · Cited by 82
Photovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63
Imaging light responses of foveal ganglion cells in the living macaque eye
Yin, L., Masella, B., Dalkara, D., Zhang, J., Flannery, J. G., Schaffer, D. V., Williams, D. R., & Merigan, W. H. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.4438-13.2014 · Cited by 54
Advances in ophthalmic optogenetics: approaches and applications
Prosseda, P. P., Tran, M., Kowal, T., Wang, B., & Sun, Y. (2022) · Biomolecules · doi:10.3390/biom12020269 · Cited by 41
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Retinal Stimulator ASIC Architecture Based on a Joint Power and Data Optical Link
Lemaire, W., Benhouria, M., Koua, K., Besrour, M., Gauthier, L.-P., Martin-Hardy, G., Rossignol, T., Roy, S., & Fontaine, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3045141 · Cited by 32
Metadata
- Authors
- Delori, F. C., Webb, R. H., & Sliney, D. H.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2007-04-11
- Volume
- 24
- Issue
- 5
- Pages
- 1250
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2001059359
- Cited by
- 480
- References
- 17
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.