The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Model for photon migration in turbid biological media
Open accessAbstract
Various characteristics of photon diffusion in turbid biological media are examined. Applications include the interpretation of data acquired with laser Doppler blood-flow monitors and the design of protocols for therapeutic excitation of tissue chromophores. Incident radiation is assumed to be applied at an interface between a turbid tissue and a transparent medium, and the reemission of photons from that interface is analyzed. Making use of a discrete lattice model, we derive an expression for the joint probability gamma(n, rho)d2 rho that a photon will be emitted in the infinitesimal area d2 rho centered at surface point rho = (x, y), having made n collisions with the tissue. Mathematical expressions are obtained for the intensity distribution of diffuse surface emission, the probability of photon absorption in the interior as a function of depth, and the mean path length of detected photons as a function of the distance between the site of the incident radiation and the location of the detector. We show that the depth dependence of the distribution of photon absorption events can be inferred from measured parameters of the surface emission profile. Results of relevant computer simulations are presented, and illustrative experimental data are shown to be in accord with the theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
New Contributions to the Optics of Intensely Light-Scattering Materials Part I
Kubelka, P. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000448 · Cited by 2,681
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Photoradiation therapy for the treatment of malignant tumors.
Dougherty, T. J., Kaufman, J., Goldfarb, A., Weishaupt, K. R., Boyle, D. G., & Mittleman, A. (1978) · PubMed · Cited by 1,834
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Self-citationKubelka, P. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000330 · Cited by 586
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Random Walks: Theory and Selected Applications
Weiss, G. H., & Rubin, R. J. (1982) · Advances in Chemical Physics · doi:10.1002/9780470142769.ch5 · Cited by 449
Self-citationMayevsky, A., & Chance, B. (1982) · Science · doi:10.1126/science.7201167 · Cited by 232
Cited by
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Flexible transparent conductive materials based on silver nanowire networks: a review
Langley, D., Giusti, G., Mayousse, C., Celle, C., Bellet, D., & Simonato, J.-P. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/45/452001 · Cited by 709
Non-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy
Tromberg, B. J., Shah, N., Lanning, R., Cerussi, A., Espinoza, J., Pham, T., Svaasand, L., & Butler, J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900082 · Cited by 687
Quantitation and mapping of tissue optical properties using modulated imaging
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., Ayers, F. R., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3088140 · Cited by 655
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Dirnagl, U., Kaplan, B., Jacewicz, M., & Pulsinelli, W. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.84 · Cited by 475
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
Optical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
Cutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130015 · Cited by 414
Meglinski, I. V., & Matcher, S. J. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/312 · Cited by 408
Hock, C., Villringer, K., Müller-Spahn, F., Wenzel, R., Heekeren, H., Schuh-Hofer, S., Hofmann, M., Minoshima, S., Schwaiger, M., Dirnagl, U., et al. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00122-4 · Cited by 377
Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329
Some applications of persistent random walks and the telegrapher's equation
Weiss, G. H. (2002) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(02)00805-1 · Cited by 278
Self-citationDiffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Metadata
- Authors
- Bonner, R. F., Nossal, R., Havlin, S., & Weiss, G. H.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1987-03-01
- Volume
- 4
- Issue
- 3
- Pages
- 423
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2065737799
- Cited by
- 376
- References
- 21
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.