Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We demonstrate lensfree holographic microscopy on a chip to achieve approximately 0.6 microm spatial resolution corresponding to a numerical aperture of approximately 0.5 over a large field-of-view of approximately 24 mm2. By using partially coherent illumination from a large aperture (approximately 50 microm), we acquire lower resolution lensfree in-line holograms of the objects with unit fringe magnification. For each lensfree hologram, the pixel size at the sensor chip limits the spatial resolution of the reconstructed image. To circumvent this limitation, we implement a sub-pixel shifting based super-resolution algorithm to effectively recover much higher resolution digital holograms of the objects, permitting sub-micron spatial resolution to be achieved across the entire sensor chip active area, which is also equivalent to the imaging field-of-view (24 mm2) due to unit magnification. We demonstrate the success of this pixel super-resolution approach by imaging patterned transparent substrates, blood smear samples, as well as Caenoharbditis Elegans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Super-resolution image reconstruction: a technical overview
Park, S. C., Park, M. K., & Kang, M. G. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1203207 · Cited by 3,282
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
Joint MAP registration and high-resolution image estimation using a sequence of undersampled images
Hardie, R. C., Barnard, K. J., & Armstrong, E. E. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.650116 · Cited by 826
High-resolution quantitative phase-contrast microscopy by digital holography
Mann, C. J., Yu, L., Lo, C.-M., & Kim, M. K. (2005) · Optics Express · doi:10.1364/opex.13.008693 · Cited by 663
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Fourier phase microscopy for investigation of biological structures and dynamics
Popescu, G., DeFlores, L. P., Vaughan, J. C., Badizadegan, K., Iwai, H., Dasari, R. R., & Feld, M. S. (2004) · Optics Letters · doi:10.1364/ol.29.002503 · Cited by 450
Woods, N. A., Galatsanos, N. P., & Katsaggelos, A. K. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.860355 · Cited by 138
Cited by
DiffuserCam: lensless single-exposure 3D imaging
Antipa, N., Kuo, G., Heckel, R., Mildenhall, B., Bostan, E., Ng, R., & Waller, L. (2018) · Optica · doi:10.1364/optica.5.000001 · Cited by 626
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationRivenson, Y., Liu, T., Wei, Z., Zhang, Y., de Haan, K., & Ozcan, A. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0129-y · Cited by 392
Self-citationOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationOzcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Self-citationCell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011) · Lab on a Chip · doi:10.1039/c0lc00684j · Cited by 288
Self-citationQuantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationSynthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Self-citationSpiroSmart: using a microphone to measure lung function on a mobile phone
Larson, E. C., Goel, M., Boriello, G., Heltshe, S., Rosenfeld, M., & Patel, S. N. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370261 · Cited by 245
Recent advances in lensless imaging
Boominathan, V., Robinson, J. T., Waller, L., & Veeraraghavan, A. (2022) · Optica · doi:10.1364/optica.431361 · Cited by 218
Gӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., et al. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0067-0 · Cited by 188
Metadata
- Authors
- Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-05-12
- Volume
- 18
- Issue
- 11
- Pages
- 11181
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2068179729
- Cited by
- 440
- References
- 11
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.