The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
Open accessAbstract
We demonstrate ultrahigh speed swept source retinal OCT imaging using a Fourier domain mode locked (FDML) laser. The laser uses a combination of a semiconductor optical amplifier and an ytterbium doped fiber amplifier to provide more than 50 mW output power. The 1050 nm FDML laser uses standard telecom fiber for the km long delay line instead of two orders of magnitude more expensive real single mode fiber. We investigate the influence of this "oligo-mode" fiber on the FDML laser performance. Two design configurations with 684,400 and 1,368,700 axial scans per second are investigated, 25x and 50x faster than current commercial instruments and more than 4x faster than previous single spot ophthalmic results. These high speeds enable the acquisition of densely sampled ultrawide-field data sets of the retina within a few seconds. Ultrawide-field data consisting of 1900 x 1900 A-scans with ~70° angle of view are acquired within only 3 and 6 seconds using the different setups. Such OCT data sets, more than double as large as previously reported, are collapsed to a 4 megapixel high definition fundus image. We achieve good penetration into the choroid by hardware spectral shaping of the laser output. The axial resolution in tissue is 12 µm (684 kHz) and 19 µm (1.37 MHz). A series of new data processing and imaging extraction protocols, enabled by the ultrawide-field isotropic data sets, are presented. Dense isotropic sampling enables both, cross-sectional images along arbitrary coordinates and depth-resolved en-face fundus images. Additionally, we investigate how isotropic averaging compares to the averaging of cross-sections along the slow axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Gloge, D. (1971) · Applied Optics · doi:10.1364/ao.10.002252 · Cited by 1,477
Microsaccades uncover the orientation of covert attention
Engbert, R., & Kliegl, R. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00084-1 · Cited by 1,390
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
Huber, R., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Self-citationIn vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
High-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Refractive indices of water and ice in the 065- to 25-μm spectral range
Kou, L., Labrie, D., & Chylek, P. (1993) · Applied Optics · doi:10.1364/ao.32.003531 · Cited by 800
Ultrahigh-resolution optical coherence tomography
Drexler, W. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629679 · Cited by 553
In Vivo Optical Coherence Tomography
Fercher, A. F., Hitzenberger, C. K., Drexler, W., Kamp, G., & Sattmann, H. (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71762-3 · Cited by 467
Single-mode fibre fractional wave devices and polarisation controllers
Lefevre, H. C. (1980) · Electronics Letters · doi:10.1049/el:19800552 · Cited by 466
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
den Dekker, A. J., & van den Bos, A. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000547 · Cited by 389
Potsaid, B., Gorczynska, I., Srinivasan, V. J., Chen, Y., Jiang, J., Cable, A., & Fujimoto, J. G. (2008) · Optics Express · doi:10.1364/oe.16.015149 · Cited by 372
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Ophthalmic imaging by spectral optical coherence tomography
Wojtkowski, M., Bajraszewski, T., Gorczyńska, I., Targowski, P., Kowalczyk, A., Wasilewski, W., & Radzewicz, C. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.04.049 · Cited by 291
Optical coherence tomography of the retina and optic nerve – a review
Sakata, L. M., DeLeon‐Ortega, J., Sakata, V., & Girkin, C. A. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02015.x · Cited by 264
Bizheva, K. K., Pflug, R., Hermann, B., Považay, B., Sattmann, H., Qiu, P. S., Anger, E., Reitsamer, H. A., Popov, S. V., Taylor, J. R., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506997103 · Cited by 231
Považay, B., Hermann, B., Unterhuber, A., Hofer, B., Sattmann, H., Zeiler, F., Morgan, J. E., Falkner-Radler, C., Glittenberg, C., Blinder, S., et al. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2773728 · Cited by 199
Srinivasan, V. J., Wojtkowski, M., Fujimoto, J. G., & Duker, J. S. (2006) · Optics Letters · doi:10.1364/ol.31.002308 · Cited by 164
Sakamoto, A., Hangai, M., & Yoshimura, N. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2007.09.001 · Cited by 156
Jenkins, M. W., Adler, D. C., Gargesha, M., Huber, R. A., Rothenberg, F. G., Belding, J., Watanabe, M., Wilson, D. L., Fujimoto, J. G., & Rollins, A. M. (2007) · Optics Express · doi:10.1364/oe.15.006251 · Cited by 149
Self-citationWide-Field Optical Coherence Tomography of the Choroid In Vivo
Považay, B., Hermann, B. M., Höfer, B., Kajic, V., Simpson, E., Bridgford, T., & Drexler, W. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2869 · Cited by 107
de Bruin, D. M., Burnes, D. L., Loewenstein, J. I., Chen, Y., Chang, S., Chen, T. C., Esmaili, D. D., & de Boer, J. F. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1553 · Cited by 100
Považay, B., Höfer, B., Torti, C., Hermann, B. M., Tumlinson, A. R., Esmaeelpour, M., Egan, C. A., Bird, A. C., & Drexler, W. (2009) · Optics Express · doi:10.1364/oe.17.004134 · Cited by 77
Spectral shaping to improve the point spread function in optical coherence tomography
Akcay, A. C., Rolland, J. P., & Eichenholz, J. M. (2003) · Optics Letters · doi:10.1364/ol.28.001921 · Cited by 59
Gorczynska, I. M., Srinivasan, V. J., Vuong, L. N., Chen, R. W. S., Liu, J. J., Reichel, E., Wojtkowski, M., Schuman, J. S., Duker, J. S., & Fujimoto, J. G. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.136101 · Cited by 54
Chen, Y., Burnes, D. L., de Bruin, D. M., Mujat, M., & de Boer, J. F. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3119103 · Cited by 42
Rosa, C. C., & Podoleanu, A. G. (2004) · Applied Optics · doi:10.1364/ao.43.004802 · Cited by 34
Optimal spectral reshaping for resolution improvement in optical coherence tomography
Gong, J., Liu, B., Kim, Y. L., Liu, Y., Li, X., & Backman, V. (2006) · Optics Express · doi:10.1364/oe.14.005909 · Cited by 30
Eigenwillig, C. M., Klein, T., Wieser, W., et al. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000104 · Cited by 27
Self-citationTumlinson, A. R., Höfer, B., Winkler, A. M., Považay, B., Drexler, W., & Barton, J. K. (2008) · Applied Optics · doi:10.1364/ao.47.000687 · Cited by 19
Cited by
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
The Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Optical methods for distance and displacement measurements
Berkovic, G., & Shafir, E. (2012) · Advances in Optics and Photonics · doi:10.1364/aop.4.000441 · Cited by 411
PODOLEANU, A. G. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03619.x · Cited by 348
Metadata
- Authors
- Klein, T., Wieser, W., Eigenwillig, C. M., Biedermann, B. R., & Huber, R.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-02-02
- Volume
- 19
- Issue
- 4
- Pages
- 3044
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2089371850
- Cited by
- 318
- References
- 36
- FWCI
- 20.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.