Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“and also increase the information content of the data (e.g., in terms of reflecting the richness of the neural dynamics) [41, 42]”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
In the citing paper
“This efficiency increase can lead to substantially improved functional SNR (Feinberg et al., 2010; (Smith et al., 2011), the ability to acquire more diffusion data points (Sotiropoulos et al., 2013c), and/or increases in spatial resolution for fMRI or dMRI (Ugurbil et al. 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“The most significant pulse sequence development for the HCP was the implementation and optimization of slice-accelerated multiband (MB) acquisitions for fMRI and dMRI (Larkman et al., 2001; Moeller et al., 2008; Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Ugurbil et al., 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“Higher temporal resolution of the fMRI data can improve overall statistical sensitivity”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“Analysis was carried out using FSL (FMRIB’s Software Library) [51,52].”
MethodSelf-citationFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“The mean (over time) image was brain-extracted using BET [54].”
MethodSelf-citationFunctional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205 · cited 2×
“Multi-acquisition RSN analysis RSNs and structured artifacts in the data were identified using MELODIC (Multivariate Exploratory Linear Optimized Decomposition into Independent Components [55], FSL’s implementation of ICA (Independent Component Analysis [56]).”
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialCorrespondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150 · cited 1×
“In addition to carrying out the high-dimensional analyses, we also used a set of 10 spatial maps from another study ([33]; 10 RSNs from 36 subjects) as the dual regression input maps.”
MethodSelf-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
BackgroundOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
Background
Cited by
Items 301–400 of 1,000
Liao, C., Bilgiç, B., Tian, Q., Stockmann, J., Cao, X., Fan, Q., Iyer, S., Wang, F., Ngamsombat, C., Lo, W., et al. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28748 · Cited by 64
BOLD Granger Causality Reflects Vascular Anatomy
Webb, J., Ferguson, M. A., Nielsen, J. A., & Anderson, J. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0084279 · Cited by 61
“An additional dataset released by the Human Connectome Project (HCP)[24,25] was tested consisting of 80 subjects for which both resting state (4 sequences of 1200 volumes each per subject, TR=720 ms, multiband BOLD acquisition[26,27], 2x2x2 mm spatial resolution) and task paradigm acquisitions were available.”
MethodSlow Down: Behavioural and Physiological Effects of Reducing Eating Rate
Hawton, K., Ferriday, D., Rogers, P. J., Toner, P., Brooks, J. C. W., Holly, J. M. P., Biernacka, K. M., Hamilton-Shield, J. P., & Hinton, E. C. (2018) · Nutrients · doi:10.3390/nu11010050 · Cited by 68
“Functional MR images were acquired in one run using a multiband sequence [61,62] using the following parameters: TR = 1000 ms, TE = 30 s, Flip angle = 70◦, FOV = 192, number of slices = 42 with 20% gap, interleaved, voxel size 2 × 2 × 2.”
MethodMolloy, E. K., Meyerand, M. E., & Birn, R. M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.09.001 · Cited by 61
“Recent technological and methodological improvements, such as multiband imaging (Feinberg et al., 2010; Larkman et al., 2001; Moeller et al., 2010; Setsompop et al., 2012), allow image volumes to be acquired much more rapidly.”
González-Castillo, J., Panwar, P., Buchanan, L. C., Caballero‐Gaudes, C., Handwerker, D. A., Jangraw, D. C., Zachariou, V., Inati, S., Roopchansingh, V., Derbyshire, J. A., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.07.049 · Cited by 59
Jovicich, J., Babiloni, C., Ferrari, C., Marizzoni, M., Moretti, D. V., Percio, C. D., Lizio, R., Lopez, S., Galluzzi, S., Albani, D., et al. (2018) · Journal of Alzheimer s Disease · doi:10.3233/jad-180158 · Cited by 60
New acquisition techniques and their prospects for the achievable resolution of fMRI
Bollmann, S., & Barth, M. (2020) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2020.101936 · Cited by 64
Churchill, N. W., & Strother, S. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.102 · Cited by 59
“We could therefore corroborate results with faster-BOLD sampling (e.g., Feinberg et al., 2010) and alternative MRI imaging modalities, such as susceptibility-weighted imaging, or measuring BOLD fMRI phase (which also provides a signal correlated with large-vessel flow; Menon et al., 2002).”
ResultFunctional connectivity fMRI in mouse brain at 7 T using isoflurane
Guilfoyle, D. N., Gerum, S. V., Sanchez, J. L., Balla, A., Sershen, H., Javitt, D. C., & Hoptman, M. J. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.01.019 · Cited by 54
Zilverstand, A., Sorger, B., Zimmermann, J., Kaas, A. L., & Goebel, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085929 · Cited by 61
“Further future improvements could be achieved by further reduction of spatial coverage, fundamentally improved hardware, advanced imaging sequences [53,54], new methods for noise reduction [55], or noise removal [56].”
BackgroundIdentifying Rodent Resting-State Brain Networks with Independent Component Analysis
Bajic, D., Craig, M. M., Mongerson, C. R., Borsook, D., & Becerra, L. R. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00685 · Cited by 62
“This will eliminate linear trends in the data, including Frontiers in Neuroscience | www.frontiersin.org 7 December 2017 | Volume 11 | Article 685 slow temporal drifts characteristic of scanner artifacts (Feinberg et al., 2010).”
BackgroundMethodInfluentialModel-based physiological noise removal in fast fMRI
Agrawal, U., Brown, E. N., & Lewis, L. D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116231 · Cited by 56
Fiber length profiling: a novel approach to structural brain organization
Bajada, C. J., Schreiber, J., & Caspers, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.070 · Cited by 55
“, 2013) with further details found in the following articles (Moeller et al., 2010; Feinberg et al., 2010; Setsompop et al., 2012; Xu et al., 2012; Sotiropoulos et al., 2013).”
Weiß, J., Martirosian, P., Notohamiprodjo, M., Kaufmann, S., Othman, M. I. A., Grosse, U., Nikolaou, K., & Gatidis, S. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000427 · Cited by 55
Fan, Q., Eichner, C., Afzali, M., Mueller, L., Tax, C. M. W., Davids, M., Mahmutović, M., Keil, B. R., Bilgiç, B., Setsompop, K., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118958 · Cited by 59
“To address his need, the HCP projects employed multiband (MB) acceleration Feinberg et al., 2010 ; Larkman et al., 2001 ; Moeller et al., 2010 ), which educes the repetition time (TR) by the number of simultaneously exited slices.”
MethodIncreasing fMRI Sampling Rate Improves Granger Causality Estimates
Lin, F.-H., Ahveninen, J., Raij, T., Witzel, T., Chu, Y.-H., Jääskeläinen, I. P., Tsai, K. W.-K., Kuo, W.-J., & Belliveau, J. W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0100319 · Cited by 55
A low power radiofrequency pulse for simultaneous multislice excitation and refocusing
Eichner, C., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25389 · Cited by 54
“[3] to account for the fact that PINS pulses possess one less gradient blips than RF sub-pulses.”
BackgroundFunctional Connectivity of Cognitive Brain Networks in Schizophrenia during a Working Memory Task
Godwin, D., Ji, A. B., Kandala, S., & Mamah, D. T. (2017) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2017.00294 · Cited by 57
“0-mm isotropic voxels, and a multi-band acceleration factor of 8 was used for whole brain acquisitions as a means of increasing signal to noise (38).”
Meyer, C., Padmala, S., & Pessoa, L. (2019) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01363 · Cited by 52
“Subsequently, we collected 457 functional EPI volumes in each run using a multiband scanning sequence (Feinberg et al., 2010), with repetition time = 1.”
InfluentialTaylor, J. E., Yamada, T., Kawashima, T., Kobayashi, Y., Yoshihara, Y., Miyata, J., Murai, T., Kawato, M., & Motegi, T. (2022) · Scientific Reports · doi:10.1038/s41598-022-05860-1 · Cited by 62
“Multiband was used to allow for faster slice acquisition 57–59 .”
Fan, Q., Nummenmaa, A. R., Witzel, T., Zanzonico, R., Keil, B. R., Cauley, S., Polimeni, J. R., Tisdall, M. D., Dijk, K. R. A. V., Buckner, R. L., et al. (2014) · Brain Connectivity · doi:10.1089/brain.2014.0305 · Cited by 57
“The diffusion acquisition was performed using a monopolar Stejskal-Tanner pulsed gradient spin echo, echo planar imaging (EPI) sequence.”
InfluentialFast fMRI provides high statistical power in the analysis of epileptic networks
Jacobs, J., Stich, J., Zahneisen, B., Assländer, J., Ramantani, G., Schulze‐Bonhage, A., Korinthenberg, R., Hennig, J., & LeVan, P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.018 · Cited by 56
“In recent years, there has been considerable interest in the development of faster fMRI sequences (Feinberg et al., 2010; Hennig et al., 2007; Lin et al., 2006, 2012; Posse et al., 2012).”
Fiber Tracts of the Medial and Inferior Surfaces of the Cerebrum
Baydın, S. Ş., Güngör, A., Tanrıöver, N., Baran, O., Middlebrooks, E. H., & Rhoton, A. L. (2016) · World Neurosurgery · doi:10.1016/j.wneu.2016.05.016 · Cited by 58
Ciric, R., Nomi, J. S., Uddin, L. Q., & Satpute, A. B. (2017) · Scientific Reports · doi:10.1038/s41598-017-06866-w · Cited by 50
Social structure learning in human anterior insula
Lau, T., Gershman, S. J., & Cikara, M. (2020) · eLife · doi:10.7554/elife.53162 · Cited by 54
“The multi-band EPI sequence was provided by the University of Minnesota Center for Magnetic Reso- nance Research (Moeller et al., 2010; Feinberg et al., 2010; Setsompop et al., 2012; Xu et al., 2013).”
Normalization governs attentional modulation within human visual cortex
Bloem, I. M., & Ling, S. (2019) · Nature Communications · doi:10.1038/s41467-019-13597-1 · Cited by 52
Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla
Jorge, J., Figueiredo, P., van der Zwaag, W., & Marques, J. P. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.07.001 · Cited by 56
“In 2DEPI, acceleration in the slice-encoding direction can be achieved either by time multiplexing, in which case signals from different slices are refocused at different times within an EPI echo train [16], or bymultislice simultaneous excitation, in which case the different slices are separated thanks to the varying…”
Simultaneous multislice excitation by parallel transmission
Poser, B. A., Anderson, R. J., Guérin, B., Setsompop, K., Deng, W., Mareyam, A., Serano, P. J., Wald, L. L., & Stenger, V. A. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24791 · Cited by 52
“The speed-up achieved by SMS acquisitions has, therefore, received particular interest in the context of blood oxygen level dependent functional MRI (fMRI) (7,9,12,13) and diffusion-weighted acquisitions (7,14) based on single-shot EPI readouts and spiral imaging (15).”
BackgroundQi, Z., Han, M., Wang, Y., Angeles, C. D. L., Liu, Q., Garel, K.-L. A., Chen, E. S., Whitfield, S., Gabrieli, J. D. E., & Perrachione, T. K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.008 · Cited by 57
“Two functional task runs containing 145 whole-brain volumes each were acquired using sparse-sampled T2*-weighted echo-planar imaging with simultaneous multi-slice scans acquisition (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012) with the following acquisition parameters: TR1⁄4 2700ms, TA (acquisi…”
MethodTask-Dependent Functional and Effective Connectivity during Conceptual Processing
Kuhnke, P., Kiefer, M., & Hartwigsen, G. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhab026 · Cited by 55
Tobe, R. H., MacKay‐Brandt, A., Lim, R. W.-S., Kramer, M., Breland, M. M., Tu, L., Tian, Y., Trautman, K. D., Hu, C., Sangoi, R., et al. (2022) · Scientific Data · doi:10.1038/s41597-022-01329-y · Cited by 61
Functional Heterogeneity and Convergence in the Right Temporoparietal Junction
Lee, S. M., & McCarthy, G. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhu292 · Cited by 51
“We used a multiplexed imaging sequence (Feinberg et al. 2010) to acquire high-resolution whole-brain fMRI data with 2-mm isotropic voxels to improve our ability to spatially discriminate among tasks.”
MethodThe future of acquisition speed, coverage, sensitivity, and resolution
Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.077 · Cited by 55
“” Recent implementations (Feinberg et al., 2010; Moeller et al., 2010) and an EPI specific improvement (Setsompop et al.”
BackgroundMethodThe quest for high spatial resolution diffusion‐weighted imaging of the human brain in vivo
Holdsworth, S. J., O’Halloran, R., & Setsompop, K. (2019) · NMR in Biomedicine · doi:10.1002/nbm.4056 · Cited by 56
“Another way to speed up the k‐space trajectory and reduce distortion is through the use of reduced FOV imaging, first demonstrated by Feinberg et al.91 The inner volume “zoomed” approach uses a selective SE refocusing pulse perpendicular to the slice selective pulse to limit the extent of signal in‐plane to prevent al…”
MethodKark, S. M., & Kensinger, E. A. (2019) · Journal of Neuroscience · doi:10.1523/jneurosci.2834-18.2019 · Cited by 53
“The functional images were acquired using simultaneous multislice blood oxygen level-dependent (SMS-BOLD) scan sequences (Barth et al., 2016) provided by the Center for Magnetic Resonance Research at University of Minnesota (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013).”
BackgroundMethodNeural correlates of intonation and lexical tone in tonal and non‐tonal language speakers
Chien, P., Friederici, A. D., Hartwigsen, G., & Sammler, D. (2020) · Human Brain Mapping · doi:10.1002/hbm.24916 · Cited by 54
“…= 2000 ms, TE = 23.2 ms, multi-band acceleration factor = 3, 60 slices in axial direction and interleaved order, thickness = 2.5 mm, 10% inter-slice gap, field of view = 192 mm, voxel size = 2 × 2 × 2.5 mm, flip angle = 90 ) (Feinberg et al., 2010; Moeller et al., 2010) and a 32-channel head coil.”
InfluentialStimulus-Specific Visual Working Memory Representations in Human Cerebellar Lobule VIIb/VIIIa
Brissenden, J. A., Tobyne, S. M., Halko, M. A., & Somers, D. C. (2020) · Journal of Neuroscience · doi:10.1523/jneurosci.1253-20.2020 · Cited by 56
“Functional data were acquired using a 123 6 multi-band gradient-echo echo-planar pulse sequence (Feinberg et al., 2010; Moeller et al., 2010; 124 Xu et al., 2013) with the following acquisition parameters: TR = 2000 ms; TE = 35 ms; FA = 125 80°; 2.2 mm isotropic voxels; FOV = 207 mm × 207 mm × 152…”
MethodInfluentialPosse, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.057 · Cited by 52
“Recent studies using multiplexed EPI (Feinberg et al., 2010), MR encephalography (Zahneisen et al.”
MethodTodd, N., Josephs, O., Zeidman, P., Flandin, G., Moeller, S., & Weiskopf, N. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00158 · Cited by 51
“With these improvements in place, investigators have demonstrated that high quality 2D EPI data can be obtained with SMS acceleration factors from 2 to 12X (Feinberg et al., 2010; Feinberg and Setsompop, 2013; Smith et al., 2013; Ugurbil et al., 2013; Xu et al., 2013).”
BackgroundSelf-citationCorreia, J., Caballero‐Gaudes, C., Guediche, S., & Carreiras, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-61435-y · Cited by 53
Tseng, J., & Poppenk, J. (2020) · Nature Communications · doi:10.1038/s41467-020-17255-9 · Cited by 60
Bernstein, G. A., Mueller, B. A., Schreiner, M. W., Campbell, S. M., Regan, E. K., Nelson, P. M., Houri, A. K., Lee, S. S., Zagoloff, A. D., Lim, K. O., et al. (2016) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2015.11.002 · Cited by 49
Self-citationWhole‐brain three‐dimensional T2‐weighted BOLD functional magnetic resonance imaging at 7 Tesla
Hua, J., Qin, Q., van Zijl, P. C. M., Pekar, J. J., & Jones, C. K. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25055 · Cited by 49
“Many exciting new technologies are being developed to further improve MRI acquisition efficiency, such as the improvement of multi-channel receiving coils to accelerate parallel imaging as well as the multiband technique (82,83,85).”
BackgroundMethodHigh-Field fMRI for Human Applications: An Overview of Spatial Resolution and Signal Specificity
Olman, C. A., & Yacoub, E. S. (2011) · The Open Neuroimaging Journal · doi:10.2174/1874440001105010074 · Cited by 57
“When spatial specificity (and resolution) is on the order of 2 mm or more, heterogeneous responses in closely juxtaposed neural populations can be confounded, which further degrades functional specificity. As an example we will consider the results of different fMRI experiments attempting to quantify iso-orientation i…”
BackgroundSelf-citationSpatio-temporal Granger causality: A new framework
Luo, Q., Lu, W., Cheng, W., Valdes-Sosa, P. A., Wen, X., Ding, M., & Feng, J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.091 · Cited by 52
Dai, E., Ma, X., Zhang, Z., Yuan, C., & Guo, H. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26249 · Cited by 49
Alonso-Sánchez, M. F., Limongi, R., Gati, J. S., & Palaniyappan, L. K. (2022) · Schizophrenia Research · doi:10.1016/j.schres.2022.04.007 · Cited by 55
Simultaneous multislice imaging in dynamic cardiac MRI at 7T using parallel transmission
Schmitter, S., Moeller, S., Wu, X., Auerbach, E. J., Metzger, G. J., de Moortele, P. V., & Uǧurbil, K. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26180 · Cited by 50
“Even calibration phases are illustrated for the SG (left) and the SP-SG algorithm (middle), whereas phases [4,8,12,16] and [2,10] were used for the multiphase SP-SG algorithm (right).”
BackgroundMethodInfluentialSelf-citationBajaj, S., Adhikari, B. M., Friston, K. J., & Dhamala, M. (2016) · Brain Connectivity · doi:10.1089/brain.2016.0422 · Cited by 93
“In the near future, because of advances in technology, it may be that concerns about lower sampling rate will not remain a major problem (Feinberg et al., 2010).”
Immediate and Longitudinal Alterations of Functional Networks after Thalamotomy in Essential Tremor
Jang, C., Park, H., Chang, W. S., Pae, C., & Chang, J. W. (2016) · Frontiers in Neurology · doi:10.3389/fneur.2016.00184 · Cited by 52
“1 Hz) of BOLD signals are known to carry meaningful information (23, 24).”
BackgroundOsada, T., Suzuki, R., Ogawa, A., Tanaka, M., Hori, M., Aoki, S., Tamura, Y., Watada, H., Kawamori, R., & Konishi, S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.056 · Cited by 51
“Functional images were obtained using multi-band gradient-echo echo-planar sequences (Feinberg et al., 2010) (TR ¼ 5 s, TE ¼ 41.6 ms, flip angle ¼ 73 deg, FOV ¼ 160 160 mm2, matrix size ¼ 128 128, 120 contiguous slices, voxel size ¼ 1.25 1.25 1.25 mm3, multi-band factor ¼ 4).”
InfluentialCohen‐Gilbert, J. E., Nickerson, L. D. H., Sneider, J. T., Oot, E. N., Seraikas, A. M., Rohan, M. L., & Silveri, M. M. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.01650 · Cited by 50
“Whole-brain multiband gradient echo echo-planar imaging (EPI) with BOLD contrast was used to collect fMRI data in three runs (5:13 min/run) (Feinberg et al., 2010).”
MethodOhlmeyer, S., Laun, F. B., Palm, T., Janka, R., Weiland, E., Uder, M., & Wenkel, E. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000560 · Cited by 50
Esser, R. W., Korn, C. W., Ganzer, F., & Haaker, J. (2021) · eLife · doi:10.7554/elife.65280 · Cited by 49
Arterial spin labeling with simultaneous multi‐slice echo planar imaging
Feinberg, D. A., Beckett, A. J. S., & Chen, L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24994 · Cited by 48
“Based on these initial results using up to MB-5, it should be possible to use even higher MB factors (21) and can be combined with SIR in multiplexed EPI (11) to simultaneously record a larger number of images to possibly enable the use of background suppression at the price of higher g-factors.”
MethodSelf-citationLi, X., Wang, D., Auerbach, E. J., Moeller, S., Uǧurbil, K., & Metzger, G. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.029 · Cited by 49
“, 2012), showing improved detection of resting state networks, as well as diffusion-weighted imaging (DWI) (Feinberg et al., 2010; Setsompop et al., 2012a) for dramatic reductions in imaging time.”
BackgroundMethodInfluentialSelf-citationFrequency of spontaneous BOLD signal shifts during infancy and correlates with cognitive performance
Alcauter, S., Lin, W., Smith, J. K., Goldman, B. D., Reznick, J. S., Gilmore, J. H., & Gao, W. (2015) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2014.10.004 · Cited by 48
Mapping spatial frequency preferences across human primary visual cortex
Broderick, W. F., Simoncelli, E. P., & Winawer, J. A. (2022) · Journal of Vision · doi:10.1167/jov.22.4.3 · Cited by 57
Lopes, R., Moeller, F., Besson, P., Ogez, F., Szurhaj, W., Leclerc, X., Siniatchkin, M., Chipaux, M., Derambure, P., & Tyvaert, L. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00201 · Cited by 47
“This approach significantly increases statistical power in functional connectivity analyses (87).”
BackgroundThompkins, A. M., Deshpande, G., Waggoner, P., & Katz, J. S. (2016) · Comparative Cognition & Behavior Reviews · doi:10.3819/ccbr.2016.110004 · Cited by 52
Pannese, A., Grandjean, D., & Frühholz, S. (2016) · Cortex · doi:10.1016/j.cortex.2016.10.013 · Cited by 52
Assessing White Matter Microstructure in Brain Regions with Different Myelin Architecture Using MRI
Groeschel, S., Hagberg, G. E., Schultz, T., Balla, D. Z., Klose, U., Hauser, T., Nägele, T., Bieri, O., Prasloski, T., MacKay, A. L., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0167274 · Cited by 52
Feinberg, D. A., Vu, A. T., & Beckett, A. J. S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.020 · Cited by 49
“This places greater constraints on peak RF power, which can be mitigated by lengthening the pulse, optimizing the phases between sub pulses (Auerbach et al., 2013; Wong, 2012) and or using low flip angles (Auerbach et al., 2013; Feinberg et al., 2010; Moeller et al., 2010).”
Self-citationFujita, S., Hagiwara, A., Hori, M., Warntjes, M. J. B., Kamagata, K., Fukunaga, I., Goto, M., Haruyama, T., Takasu, K., Andica, C., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26744 · Cited by 49
Multi-shell diffusion signal recovery from sparse measurements
Rathi, Y., Michailovich, O., Laun, F. B., Setsompop, K., Grant, P. E., & Westin, C. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.06.003 · Cited by 47
“…complementary approaches have been proposed, namely: (i) the use of compressed sensing (CS) to reduce the number of measurements (Candès et al., 2006; Donoho, 2006), and (ii) the use of multi-slice acquisition sequences for faster data acquisition (Setsompop et al., 2011; Feinberg et al., 2010).”
BackgroundBoyacıoğlu, R., Schulz, J., Müller, N. C. J., Koopmans, P. J., Barth, M., & Norris, D. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.011 · Cited by 50
“…(GRAPPA Griswold et al, SENSE, Pruessmann et al, SMASH (Sodickson and Manning) )(Griswold et al., 2002; Pruessmann et al., 1999; Sodickson and Manning, 1997), it took almost a decade to receive any attention and interest from the MR community (Feinberg et al., 2010; Moeller et al., 2010).”
Dick, F., Lehet, M. I., Callaghan, M. F., Keller, T. A., Sereno, M. I., & Holt, L. L. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.1436-17.2017 · Cited by 51
Frank, D. W., Costa, V. D., Averbeck, B. B., & Sabatinelli, D. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00780.2018 · Cited by 49
Multidimensional encoding of brain connectomes
Caiafa, C. F., & Pestilli, F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09250-w · Cited by 50
Development of a transcallosal tractography template and its application to dementia
Archer, D. B., Coombes, S. A., McFarland, N. R., DeKosky, S. T., & Vaillancourt, D. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.065 · Cited by 49
Partial Least Squares Regression Performs Well in MRI-Based Individualized Estimations
Chen, C., Cao, X., & Tian, L. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01282 · Cited by 50
“More details about temporal pre-processing could be found in Smith et al. (2013). Regions of interest time-series were then extracted from the pre-processed resting state fMRI images based on ICA.”
BackgroundMethodInfluentialFunctional harmonics reveal multi-dimensional basis functions underlying cortical organization
Glomb, K., Kringelbach, M. L., Deco, G., Hagmann, P., Pearson, J., & Atasoy, S. (2021) · Cell Reports · doi:10.1016/j.celrep.2021.109554 · Cited by 56
Age-Dependent Contribution of Domain-General Networks to Semantic Cognition
Martin, S., Saur, D., & Hartwigsen, G. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhab252 · Cited by 49
“For the acquisition of fMRI data, a dual gradient echo-planar imaging multiband sequence (Feinberg et al. 2010) was used for optimal blood oxygen level– dependent (BOLD) sensitivity across the whole brain (Poser”
MethodJosephs, E., & Konkle, T. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1912333117 · Cited by 49
Du, H., Liao, X., Lin, Q., Li, G., Chi, Y., Liu, X., Yang, H., Wang, Y., & Xia, M. (2015) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.12431 · Cited by 46
“Recently, the development of imaging techniques, including multiband echo-planar imaging [65,66] and MR-encephalography [67], has enabled whole-brain image acquisition at a higher temporal resolution (<1 s), which can diminish the effects of respiratory and cardiac noises [64].”
BackgroundHocke, L. M., Tong, Y., Lindsey, K. P., & Frederick, B. B. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26038 · Cited by 47
“Afterward, multiband EPI data were obtained [University of Minnesota sequence cmrr_mbep2d_bold R008 (11,12)] using the following parameters: TR/TE¼ 400/30 ms (n¼ 8) and TR/ TE¼520/30 ms (n¼10); flip angle¼43 ; matrix¼ 64 64; field of view¼ 220 220 mm; multiband factor¼ 6 (this multiband factor was a compromise value i…”
BackgroundMethodInfluentialIn need of constraint: Understanding the role of the cingulate cortex in the impulsive mind
Golchert, J., Smallwood, J., Jefferies, E., Liem, F., Huntenburg, J. M., Falkiewicz, M., Lauckner, M. E., Oligschläger, S., Villringer, A., & Margulies, D. S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.041 · Cited by 47
Resting-State Functional Connectivity in the Infant Brain: Methods, Pitfalls, and Potentiality
Mongerson, C. R., Jennings, R. W., Borsook, D., Becerra, L. R., & Bajic, D. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00159 · Cited by 49
“High-pass filtering eliminates linear trends in the data (44), including lower frequencies associated with MRI scanner artifacts (64).”
BackgroundTemporal transitions of spontaneous brain activity
Ma, Z., & Zhang, N. (2018) · eLife · doi:10.7554/elife.33562 · Cited by 50
Sinha, N., Berg, C. N., Tustison, N. J., Shaw, A., Hill, D., Yassa, M. A., & Gluck, M. A. (2018) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2018.05.023 · Cited by 42
“Furthermore, the high temporal efficiency has been shown to provide greater statistical power (Feinberg et al., 2010).”
Zhang, C. H., Sha, Z., Mundahl, J., Liu, S., Lu, Y., Henry, T. R., & He, B. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.07.014 · Cited by 48
“With advancement in MRI acquisition techniques using multiband approaches, TR can be shortened to 400 ms (Feinberg et al., 2010; Uğurbil et al., 2013).”
Pinho, A. L., Amadon, A., Gauthier, B., Clairis, N., Knops, A., Genon, S., Dohmatob, E., Torre, J. J., Ginisty, C., Becuwe-Desmidt, S., et al. (2020) · Scientific Data · doi:10.1038/s41597-020-00670-4 · Cited by 47
Multiband phase‐constrained parallel MRI
Blaimer, M., Choli, M., Jakob, P. M., Griswold, M. A., & Breuer, F. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24685 · Cited by 44
Slice accelerated diffusion‐weighted imaging at ultra‐high field strength
Eichner, C., Setsompop, K., Koopmans, P. J., Lützkendorf, R., Norris, D. G., Turner, R., Wald, L. L., & Heidemann, R. M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24809 · Cited by 42
“Finally, multiplexed EPI has also been proposed, which combines parallel imaging-based SMS acquisition with SIR imaging (12).”
MethodHybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI
Zhu, K., Dougherty, R. F., Wu, H., Middione, M. J., Takahashi, A., Zhang, T., Pauly, J. M., & Kerr, A. B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2531635 · Cited by 49
Quantitative T2 mapping of white matter: applications for ageing and cognitive decline
Knight, M. J., McCann, B., Tsivos, D., Dillon, S., Coulthard, E. J., & Kauppinen, R. A. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/15/5587 · Cited by 51
On the detection of high frequency correlations in resting state fMRI
Trapp, C., Vakamudi, K., & Posse, S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.059 · Cited by 47
Diffusion MRI of the human brain at ultra-high field (UHF): A review
Gallichan, D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.037 · Cited by 45
“In recent years there has been widespread use of simultaneous multi-slice (SMS) acquisitions (Breuer et al., 2005; Feinberg et al., 2010; Larkman et al., 2001; Moeller et al., 2010; K. Setsompop et al., 2012; Kawin Setsompop et al., 2012) (see also review article in this special issue), primarily for fMRI and DTI appl…”
Park, H., Pae, C., Friston, K. J., Jang, C., Razi, A., Zeidman, P., Chang, W. S., & Chang, J. W. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00346 · Cited by 50
“1 Hz), as they are known to contain meaningful information in restingstate studies (26, 27).”
BackgroundTaron, J., Martirosian, P., Küstner, T., Schwenzer, N. F., Othman, M. I. A., Weiß, J., Notohamiprodjo, M., Nikolaou, K., & Schraml, C. (2017) · European Radiology · doi:10.1007/s00330-017-5132-1 · Cited by 47
Shashidhara, S., Spronkers, F. S., & Erez, Y. (2020) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01554 · Cited by 49
“A T2*-weighted 2D multiband Echo-Planar Imaging, with a multi-band factor of 3, was used to acquire 2 mm isotropic voxels (Feinberg et al., 2010).”
MethodMagnetic Resonance Field Strength Effects on Diffusion Measures and Brain Connectivity Networks
Zhan, L., Mueller, B. A., Jahanshad, N., Jin, Y., Lenglet, C., Yacoub, E. S., Sapiro, G., Uǧurbil, K., Harel, N., Toga, A. W., et al. (2012) · Brain Connectivity · doi:10.1089/brain.2012.0114 · Cited by 50
“…of Minnesota Consortium) and 300 mT/m (MGH-UCLA consortium), or recently demonstrated accelerated pulse sequences that can reduce the repetition time (Feinberg et al., 2010; Setsompop et al., 2012), we may have found different patterns of differences, including the differences between scanners.”
BackgroundMethodSelf-citationDifferential contributions of left-hemispheric language regions to basic semantic composition
Graessner, A., Zaccarella, E., & Hartwigsen, G. (2021) · Brain Structure and Function · doi:10.1007/s00429-020-02196-2 · Cited by 44
Kirilina, E. P., Lutti, A., Poser, B. A., Blankenburg, F., & Weiskopf, N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.071 · Cited by 49
“To overcome these limitations, recently novel EPI approaches have been developed capitalizing on progress in k-space acquisition trajectories, parallel imaging and simultaneous excitation (Lutti et al., 2013; Poser et al., 2006, 2010; Feinberg et al., 2010; Setsompop et al., 2012).”
BackgroundKochunov, P., Chiappelli, J., Wright, S. N., Rowland, L. M., Patel, B., Wijtenburg, S. A., Nugent, K. L., McMahon, R. P., Carpenter, W. T., Muellerklein, F., et al. (2014) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2014.05.004 · Cited by 43
Yoo, P. E., John, S. E., Farquharson, S., Cleary, J. O., Wong, Y. T., Ng, A., Mulcahy, C. B., Grayden, D. B., Ordidge, R. J., Opie, N. L., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.002 · Cited by 45
Puckett, A. M., Bollmann, S., Poser, B. A., Palmer, J. R., Barth, M., & Cunnington, R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.005 · Cited by 44
“In a separate development, SMS EPI (Feinberg et al., 2010; Setsompop et al., 2012) based on earlier work by Larkman et al.”
MethodInfluentialMemory Efficient PCA Methods for Large Group ICA
Rachakonda, S., Silva, R. F., Liu, J., & Calhoun, V. D. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00017 · Cited by 42
“Group ICA is regularly being used to analyze large numbers of subjects (Biswal et al., 2010; Allen et al., 2011), and multi-band EPI sequences (Feinberg et al., 2010; Setsompop et al., 2012) put even more memory demands on group PCA if the number of components retained in the first PCA step is…”
BackgroundMethodChang, H., Guhaniyogi, S., & Chen, N. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25318 · Cited by 42
Tong, Y., Hocke, L. M., & Frederick, B. B. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25041 · Cited by 41
Metadata
- Authors
- Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
- Affiliations
- University of California, San Francisco (US)
- University of Minnesota (US)
- John Radcliffe Hospital (GB)
- Advanced MRI Technologies (United States) (US)
- Washington University in St. Louis (US)
- Corresponding author
- Feinberg, David A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 12
- Pages
- e15710
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3004955
- OpenAlex
- W2114809469
- Cited by
- 1,296
- References
- 57
- Citations by year
- 2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
- FWCI
- 44.96
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-09-28)
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
- W. M. Keck Foundation
- National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
- National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
- National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
- National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
- NIH Blueprint for Neuroscience Research (1U54-MH-091657)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
- MeSH terms
- Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.