Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“and also increase the information content of the data (e.g., in terms of reflecting the richness of the neural dynamics) [41, 42]”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
In the citing paper
“This efficiency increase can lead to substantially improved functional SNR (Feinberg et al., 2010; (Smith et al., 2011), the ability to acquire more diffusion data points (Sotiropoulos et al., 2013c), and/or increases in spatial resolution for fMRI or dMRI (Ugurbil et al. 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“The most significant pulse sequence development for the HCP was the implementation and optimization of slice-accelerated multiband (MB) acquisitions for fMRI and dMRI (Larkman et al., 2001; Moeller et al., 2008; Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Ugurbil et al., 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“Higher temporal resolution of the fMRI data can improve overall statistical sensitivity”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“Analysis was carried out using FSL (FMRIB’s Software Library) [51,52].”
MethodSelf-citationFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“The mean (over time) image was brain-extracted using BET [54].”
MethodSelf-citationFunctional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205 · cited 2×
“Multi-acquisition RSN analysis RSNs and structured artifacts in the data were identified using MELODIC (Multivariate Exploratory Linear Optimized Decomposition into Independent Components [55], FSL’s implementation of ICA (Independent Component Analysis [56]).”
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialCorrespondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150 · cited 1×
“In addition to carrying out the high-dimensional analyses, we also used a set of 10 spatial maps from another study ([33]; 10 RSNs from 36 subjects) as the dual regression input maps.”
MethodSelf-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
BackgroundOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
Background
Cited by
Items 401–500 of 1,000
Altered Regional Homogeneity in Rolandic Epilepsy: A Resting-State fMRI Study
Tang, Y., Ji, G., Yu, Y., Wang, J., Wang, Z.-J., Zang, Y., Liao, W., & Ding, M. (2014) · BioMed Research International · doi:10.1155/2014/960395 · Cited by 43
“Future study should use advanced data acquisition sequences to enable whole brain fMRI scanning at subsecond temporal resolution [61].”
MethodVariation of HbA1c affects cognition and white matter microstructure in healthy, young adults
Repple, J., Karliczek, G., Meinert, S., Förster, K., Grotegerd, D., Goltermann, J., Redlich, R., Arolt, V., Baune, B. T., Dannlowski, U., et al. (2019) · Molecular Psychiatry · doi:10.1038/s41380-019-0504-3 · Cited by 49
“Louis, using a standard 32-channel Siemens receive head coil and a “body” transmission coil designed by Siemens specifically for the smaller space available using the special gradients of the WU-Minn and MGH-UCLA Connectome scanners [21, 24].”
MethodJiramongkolchai, P., Jones, M. S., Peterson, A. M., Lee, J. J., Liebendorfer, A., Klatt‐Cromwell, C. N., Schneider, J. S., Drescher, A. J., Ogden, M. A., Brunworth, J. D., et al. (2021) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2021.0086 · Cited by 43
Impacts of simultaneous multislice acquisition on sensitivity and specificity in fMRI
Risk, B. B., Kociuba, M. C., & Rowe, D. B. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.078 · Cited by 43
“Test statistics and temporal signal-to-noise ratio (tSNR) may benefit from an increase in the effective sample size resulting from the collection of a higher number of volumes in the same run duration (Todd et al., 2016; Feinberg et al., 2010).”
Hennig, J., Kiviniemi, V. J., Riemenschneider, B., Barghoorn, A., Akın, B., Wang, F., & LeVan, P. (2020) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-020-00891-z · Cited by 43
Metabolic underpinnings of activated and deactivated cortical areas in human brain
Koush, Y., de Graaf, R. A., Kupers, R. C., Dricot, L., Ptito, M., Behar, K. L., Rothman, D. L., & Hyder, F. (2021) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x21989186 · Cited by 41
Bush, K., & Cisler, J. M. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.03.015 · Cited by 44
“For example, Feinberg and colleagues [34] recently introduced multiplexed echo planar imaging that reduced TR to .”
Mangalathu-Arumana, J., Beardsley, S. A., & Liebenthal, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.030 · Cited by 45
Whole brain perfusion measurements using arterial spin labeling with multiband acquisition
Kim, T., Shin, W., Zhao, T., Beall, E. B., Lowe, M. J., & Bae, K. T. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24880 · Cited by 40
“The MB method can work in combination with in-plane parallel imaging (12,14) as well as simultaneous echo refocusing (13,14).”
MethodEichner, C., Jafari‐Khouzani, K., Cauley, S., Bhat, H., Polaskova, P., Andronesi, O. C., Rapalino, O., Turner, R., Wald, L. L., Stufflebeam, S. M., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24960 · Cited by 41
“In recent works, the SMS technique was also combined with simultaneous echo refocusing (9) and used to acquire fMRI and diffusion data at high temporal sampling rate (10,11).”
MethodThakral, P. P., Benoit, R. G., & Schacter, D. L. (2017) · Cortex · doi:10.1016/j.cortex.2017.02.005 · Cited by 39
“…imaging sequence (University of Minnesota C2P sequence: TR = 2 s, TE = 30 ms, matrix size of 136 × 136, 84 slices (3 slices acquired simultaneously), 1.5 mm3 resolution, multiband factor of 3, in-plane GRAPPA acceleration factor of 2; Moeller et al., 2009; Feinberg et al., 2010; Xu et al., 2013).”
MethodInfluentialAn Investigation of RSN Frequency Spectra Using Ultra-Fast Generalized Inverse Imaging
Boyacıoğlu, R., Beckmann, C. F., & Barth, M. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00156 · Cited by 39
“Another drawback of low TR acquisitions and GIN is the abundance of physiological noise related components obtained with regular ICA as they dominate the total variance in the data.”
BackgroundMethodInfluentialBeyond the Lesion: Neuroimaging Foundations For Post-Stroke Recovery
Carey, L. M., Seitz, R. J., Parsons, M., Levi, C., Farquharson, S., Tournier, J.-D., Palmer, S., & Connelly, A. (2013) · Future Neurology · doi:10.2217/fnl.13.39 · Cited by 38
Mejia, A. F., Nebel, M. B., Barber, A. D., Choe, A. S., Pekar, J. J., Caffo, B. S., & Lindquist, M. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.029 · Cited by 41
“For 461 subjects, a multi-band/multi-slice pulse sequence with an acceleration factor of eight (Moeller et al., 2010; Feinberg et al., 2010; Setsompop et al., 2012; Xu et al., 2012; U gurbil et al., 2013) was used to acquire four roughly 15-minute rs-fMRI sessions, each consisting of 1200 vol sampled every 0.”
Jahanian, H., Holdsworth, S. J., Christen, T., Wu, H., Zhu, K., Kerr, A. B., Middione, M. J., Dougherty, R. F., Moseley, M. E., & Zaharchuk, G. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.09.033 · Cited by 40
Messaritaki, E., Dimitriadis, S. I., & Jones, D. K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.052 · Cited by 41
“The HCP acquisition details are described in Sotiropoulos et al. (2013b); Feinberg et al. (2010); Moeller et al. (2010); Setsompop et al. (2012); Sotiropoulos et al. (2013a); Xu et al. (2012).”
Autio, J. A., Zhu, Q., Li, X., Glasser, M. F., Schwiedrzik, C. M., Fair, D. A., Zimmermann, J., Yacoub, E. S., Menon, R. S., Essen, D. C. V., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118082 · Cited by 42
Self-citationLeading non‐Gaussian corrections for diffusion orientation distribution function
Jensen, J. H., Helpern, J. A., & Tabesh, A. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3053 · Cited by 42
Efficient PCA denoising of spatially correlated redundant MRI data
Henriques, R. N., Ianuș, A., Novello, L., Jovicich, J., Jespersen, S. N., & Shemesh, N. (2023) · Imaging Neuroscience · doi:10.1162/imag_a_00049 · Cited by 48
“Diffusion MRI data were acquired using a monopolar single diffusion encoding EPI PGSE ( Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013) MPPCA, GPCA, and TPCA denoising were applied with a 3D sliding window of 9 × 9 × 3 voxels to perform PCA denoising on a number of voxels ( M = 242)…”
MethodDean, D., Tisdall, M. D., Wisnowski, J. L., Feczko, E., Gagoski, B. A., Alexander, A. L., Edden, R. A. E., Gao, W., Hendrickson, T. J., Howell, B., et al. (2024) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2024.101452 · Cited by 53
“The dMRI acquisition uses MB3 with no additional in-plane acceleration (Feinberg et al., 2010).”
Self-citationEffect of temporal resolution and serial autocorrelations in event‐related functional MRI
Sahib, A. K., Mathiak, K., Erb, M., Elshahabi, A., Klamer, S., Scheffler, K., Focke, N. K. N., & Ethofer, T. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26073 · Cited by 39
“Consequently, several methods have been developed to speed up acquisition of whole-brain fMRI data, including simultaneous multislice (SMS) EPI (12), simultaneous image refocused (SIR) EPI (13), improved single-shot echovolumar imaging (e.g., van der Zwaag et al) (14), inverse imaging (15), undersampled projection ima…”
BackgroundNocebo-induced modulation of cerebral itch processing – An fMRI study
van de Sand, M. F., Menz, M. M., Sprenger, C., & Büchel, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.056 · Cited by 41
“, 2002) and simultaneous multi-slice acquisitions of 2 32 slices (“multiband”, slice acceleration factor 2; Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013) as described in Setsompop et al.”
Knight, M. J., Wearn, A. R., Coulthard, E. J., & Kauppinen, R. A. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26195 · Cited by 40
Brain networks underlying tactile softness perception: A functional magnetic resonance imaging study
Kitada, R., Doizaki, R., Kwon, J., Tanigawa, T., Nakagawa, E., Kochiyama, T., Kajimoto, H., Sakamoto, M., & Sadato, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.044 · Cited by 40
Empirical validation of directed functional connectivity
Mill, R. D., Bagic, A. I., Bostan, A. C., Schneider, W., & Cole, M. W. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.037 · Cited by 43
“Whilst we were constrained to a small sample size by the multi-modal and multisession nature of our study, future research might clarify whether deconvolution applied to larger samples yields significant absolute coefficients, and whether newer multiband fMRI sequences (enabling sub-second TR acquisition; Feinberg et…”
MethodRoy, A. V., Thai, M., Klimes‐Dougan, B., Schreiner, M. W., Mueller, B. A., Albott, C. S., Lim, K. O., Fiecas, M. J. A., Tye, S. J., & Cullen, K. R. (2020) · Journal of Psychopharmacology · doi:10.1177/0269881120928203 · Cited by 39
“We utilized a multiband echo planar imaging sequence to improve the spatial and temporal resolution of the acquired fMRI data over conventional methods (Feinberg et al., 2010).”
MethodMetacognitive resources for adaptive learning⋆
Cortese, A. (2022) · Neuroscience Research · doi:10.1016/j.neures.2021.09.003 · Cited by 33
“…context multivoxel neural reinforcement (also known as decoded neurofeedback) is an attractive causal approach (Shibata et al., 2011; Taschereau-Dumouchel et al., 2020), which has evolved with recent developments in neuro-imaging (Feinberg et al., 2010; Haxby et al., 2014, 2011; Xu et al., 2013).”
Fractal analysis of spontaneous fluctuations of the BOLD signal in rat brain
Hermán, P., Sanganahalli, B. G., Hyder, F., & Eke, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.082 · Cited by 41
“There are recent examples for much improved temporal resolution studies using high field human scanners (Feinberg et al., 2010; Poser et al., 2010).”
BackgroundSimultaneous Multi-Slice fMRI using spiral trajectories
Zahneisen, B., Poser, B. A., Ernst, T., & Stenger, V. A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.056 · Cited by 38
“Sub-second whole brain imaging is of particular interest in Blood Oxygen Level Dependent (BOLD) functional Magnetic Resonance Imaging (fMRI) (Feinberg et al., 2010; Posse et al., 2012; Zahneisen et al., 2012).”
Shao, X., Wang, Y. H., Moeller, S., & Wang, D. J. J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26643 · Cited by 38
Self-citationPreti, M. G., & Ville, D. V. D. (2017) · Scientific Reports · doi:10.1038/s41598-017-12993-1 · Cited by 37
Uji, M., Wilson, R., Francis, S., Mullinger, K. J., & Mayhew, S. D. (2018) · Human Brain Mapping · doi:10.1002/hbm.23943 · Cited by 42
“MB fMRI has been shown to be useful in a number of different applications as its conception only a few years ago, with the relative gains in sampling rate and voxel size that it can provide offsetting any signal quality degradation incurred (Boyacio glu, Schulz, Koopmans, Barth, & Norris, 2015; Feinberg et al., 2010;…”
BackgroundMethodUltrahigh field systems and applications at 7 T and beyond: Progress, pitfalls, and potential
Bandettini, P. A., Bowtell, R. W., Jezzard, P., & Turner, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23151 · Cited by 38
“Use of multiband RF pulses combined with parallel acquisition can also yield acceleration factors as high as 16 (6).”
BackgroundInfluentialCurtis, B. J., Williams, P., Jones, C. R., & Anderson, J. S. (2016) · Brain and Behavior · doi:10.1002/brb3.576 · Cited by 43
“Multiband BOLD resting state data from this release (Feinberg et al., 2010; Glasser et al., 2013; Griffanti et al., 2014; Jesmanowicz, Nencka, Li, & Hyde, 2011; Moeller et al., 2010; Setsompop et al., 2012; Van Essen et al., 2013) consisted of FIX ICA cleaned BOLD resting state data (Griffanti et al.”
MethodSala‐Llonch, R., Smith, S. M., Woolrich, M. W., & Duff, E. P. (2018) · Human Brain Mapping · doi:10.1002/hbm.24381 · Cited by 42
“FMRI time series activity will combine a variety of signals across a wide range of frequencies, particularly with the development of fast multiband sequences (Feinberg et al., 2010; Moeller et al., 2010).”
BackgroundSelf-citationMaking Sense of Real-Time Functional Magnetic Resonance Imaging (rtfMRI) and rtfMRI Neurofeedback
Brühl, A. B. (2015) · The International Journal of Neuropsychopharmacology · doi:10.1093/ijnp/pyv020 · Cited by 36
“…response function; Buckner, 1998; Logothetis et al., 2001) is rather slow: after an initial short “undershoot” due to the increased oxygen consumption in an activated area, the signal peaks after about 5 to 6 seconds and returns to baseline 12 to 15 seconds after the initial activation (Figure 1).”
BackgroundShen, K., Goulas, A., Grayson, D. S., Eusebio, J., Gati, J. S., Menon, R. S., McIntosh, A. R., & Everling, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.018 · Cited by 38
“For the remaining 3 animals, a multiband EPI diffusion sequence (Feinberg et al., 2010; Moeller et al., 2010) was used; TE/TR1⁄4 47ms/6000ms, multiband1⁄4 2, b1⁄4 1000 s/mm2, 64 directions, 128 128 matrix, 24 slices, iPat1⁄4 2, Partial fourier1⁄4 5/8 and bandwidth of 1502 Hz/px.”
Csukly, G., Szabó, Á., Polgár, P., Farkas, K., Gyebnár, G., Kozák, L. R., & Stefanics, G. (2020) · Psychological Medicine · doi:10.1017/s0033291720000859 · Cited by 38
“Higher frequencies (>0.1 Hz) were not removed, since they are known to contain meaningful information in resting-state studies (Feinberg et al., 2010; Lin et al., 2015).”
InfluentialCohen, A. D., Yang, B., Fernandez, B., Banerjee, S., & Wang, Y. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117461 · Cited by 44
Auditory neuroimaging with fMRI and PET
Talavage, T. M., González-Castillo, J., & Scott, S. K. (2013) · Hearing Research · doi:10.1016/j.heares.2013.09.009 · Cited by 42
“A second hardware advance worth noting here is the development of procedures for using arrays of coils (e.g., Bodurka et al., 2004) in conjunction with advanced acquisition acceleration techniques that simultaneously acquire data from multiple slices (Feinberg et al., 2010; Moeller et al., 2010).”
MethodUltrafast fMRI of the rodent brain using simultaneous multi-slice EPI
Lee, H., Li, Z., Coulson, E. J., & Chuang, K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.045 · Cited by 37
Classification of obsessive-compulsive disorder from resting-state fMRI
Sen, B., Bernstein, G. A., Xu, T., Mueller, B. A., Schreiner, M. W., Cullen, K. R., & Parhi, K. K. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591508 · Cited by 35
“Resting state fMRI scans (2 sessions each of 12 minutes duration) were taken using a novel multiband EPI sequence that accounts for acquiring multiple slices simultaneously [5].”
MethodInfluence of physiological noise on accelerated 2D and 3D resting state functional MRI data at 7 T
Reynaud, O., Jorge, J., Rolf Gruetter, A., Marques, J. P., & van der Zwaag, W. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26823 · Cited by 35
“The Z-score scales in [2-10] (red/blue, positive/negative).”
Four in vivo g‐ratio‐weighted imaging methods: Comparability and repeatability at the group level
Ellerbrock, I., & Mohammadi, S. (2017) · Human Brain Mapping · doi:10.1002/hbm.23858 · Cited by 37
“, 2002] and simultaneous multislice acquisitions (“multiband,” slice acceleration factor 2) [Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013] as described in Setsompop et al.”
BackgroundMethodTractography optimization using quantitative T1 mapping in the human optic radiation
Schurr, R., Duan, Y., Norcia, A. M., Ogawa, S., Yeatman, J. D., & Mezer, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.060 · Cited by 36
“For the HCP dataset we used high resolution HARDI data with b ¼ 2000 s/mm2 and 90 diffusion directions with a spatial resolution of 1.25 mm isotropic spatial resolution (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Sotiropoulos et al., 2013).”
MethodInfluentialDissociable roles of left and right temporoparietal junction in strategic competitive interaction
Ogawa, A., & Kameda, T. (2019) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsz082 · Cited by 36
“5 s, TE = 25 ms, FA = 70◦) using multi-band gradient-echo echo-planar sequences (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013) with multi-band factor = 4.”
Word learning reveals white matter plasticity in preschool children
Ekerdt, C., Kühn, C., Anwander, A., Bräuer, J., & Friederici, A. D. (2020) · Brain Structure and Function · doi:10.1007/s00429-020-02024-7 · Cited by 37
Quiet and distortion‐free, whole brain BOLD fMRI using T2‐prepared RUFIS
Solana, A. B., Menini, A., Sacolick, L. I., Hehn, N., & Wiesinger, F. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25658 · Cited by 37
“However, 2D EPI-based pulse sequences can be accelerated using parallel imaging methods or multiband approaches (10,43,65), providing for example whole brain coverage (excluding cerebellum) with 3 mm spatial resolution in 400 ms using 18-fold acceleration (65) or 1.”
MethodAnisotropy of spin-echo T 2 relaxation by magnetic resonance imaging in the human brain in vivo
Knight, M. J., Wood, B., Coulthard, E. J., & Kauppinen, R. A. (2015) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-150114 · Cited by 35
“75 mm) [13].”
Chen, J. E., Jahanian, H., & Glover, G. H. (2016) · Brain Connectivity · doi:10.1089/brain.2016.0441 · Cited by 36
“…data using accelerated acquisitions with the expectation of increased statistical power (more sampling points within a fixed scan duration) and identification of cardiac/respiratory peaks in signal spectra (Boyacioglu et al., 2015; Feinberg et al., 2010; Griffanti et al., 2014; Posse et al., 2012).”
BackgroundReynolds, B. B., Stanton, A. N., Soldozy, S., Goodkin, H. P., Wintermark, M., & Druzgal, T. J. (2017) · Brain Imaging and Behavior · doi:10.1007/s11682-017-9790-z · Cited by 37
Vakamudi, K., Posse, S., Jung, R. E., Cushnyr, B., & Chohan, M. O. (2019) · Human Brain Mapping · doi:10.1002/hbm.24840 · Cited by 39
“Recent efforts of parcellating RSN connectivity in single subjects have sought to overcome the shortcomings of spatial normalization, lesion-related plasticity, and variability due to structured noise sources, by using multiscale clustering, dictionary-based learning, template matching, multilayer artificial neural ne…”
BackgroundInfluentialFunctional connectivity‐based parcellation of the human sensorimotor cortex
Long, X., Goltz, D., Margulies, D. S., Nierhaus, T., & Villringer, A. (2014) · European Journal of Neuroscience · doi:10.1111/ejn.12473 · Cited by 40
“58 ms; Bandwidth (BW), 2290 Hz/Px; time points, 1200 (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Xu et al., 2012).”
InfluentialGeneralized iNverse imaging (GIN): Ultrafast fMRI with physiological noise correction
Boyacıoğlu, R., & Barth, M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24528 · Cited by 34
“[8] is expanded for one (the first) channel with Eq.”
BackgroundDistinct Reward Properties are Encoded via Corticostriatal Interactions
Smith, D. V., Rigney, A. E., & Delgado, M. R. (2016) · Scientific Reports · doi:10.1038/srep20093 · Cited by 31
HIgh b-value and high Resolution Integrated Diffusion (HIBRID) imaging
Fan, Q., Nummenmaa, A. R., Polimeni, J. R., Witzel, T., Huang, S. Y., Wedeen, V. J., Rosen, B. R., & Wald, L. L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.002 · Cited by 34
Ster, C. L., Moreno, A., Mauconduit, F., Gras, V., Stirnberg, R., Poser, B. A., Vignaud, A., Eger, E., Dehaene, S., Meyniel, F., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225286 · Cited by 35
“Simultaneous multislice EPI (SMS-EPI) [1, 2] has marked a paradigm shift in functional neuroimaging [3].”
BackgroundSiless, V., Hubbard, N. A., Jones, R. J., Wang, J., Lo, N., Bauer, C. C. C., Goncalves, M., Frosch, I. R., Norton, D. J., Vergara, G. A., et al. (2020) · NeuroImage Clinical · doi:10.1016/j.nicl.2020.102242 · Cited by 40
Landelle, C., Anton, J., Nazarian, B., Sein, J., Gharbi, A., Félician, O., & Kavounoudias, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117056 · Cited by 36
“Bloodoxygen-level-dependant (BOLD) images were acquired with a multiband sequence (Multi-Band EPI C2P v014) provided by the University of Minnesota (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013).”
MethodSignificant feed-forward connectivity revealed by high frequency components of BOLD fMRI signals
Lin, F., Chu, Y.-H., Hsu, Y.-C., Lin, J.-F. L., Tsai, K. W., Tsai, S., & Kuo, W. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.036 · Cited by 39
“However, if the frequency components up to 2–3 Hz is sufficient, simultaneous multi-slice imaging, a method of sub-second whole-brain fMRI (Feinberg et al., 2010), may be used without compromising the spatial resolution.”
Magnetic Resonance Relaxation Anisotropy: Physical Principles and Uses in Microstructure Imaging
Knight, M. J., Dillon, S., Jarutytė, L., & Kauppinen, R. A. (2017) · Biophysical Journal · doi:10.1016/j.bpj.2017.02.026 · Cited by 36
“The acquisition included a three-dimensional (3D) T1-weighted MPRAGE (sagittal, 0.86 0.86 0.86 mm3), two-dimensional (2D) multiecho spin-echo (axial, 1.15 1.15 1.98 mm3) and 2D multiband diffusion tensor imaging (DTI) (16) (axial, 1.88 1.88 1.98 mm3).”
BackgroundInfluentialThe effects of sleep on the neural correlates of pattern separation
Doxey, C. R., Hodges, C. B., Bodily, T. A., Muncy, N. M., & Kirwan, C. B. (2017) · Hippocampus · doi:10.1002/hipo.22814 · Cited by 37
“Multi-band fMRI (Feinberg et al., 2010; Moeller et al., 2010; Yassa et al., 2011) overcomes these challenges”
BackgroundDiNicola, L. M., Ariyo, O., & Buckner, R. L. (2022) · Journal of Neurophysiology · doi:10.1152/jn.00211.2022 · Cited by 38
Dona, O., Noseworthy, M. D., DeMatteo, C., & Connolly, J. F. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169647 · Cited by 30
Exploring structure and function of sensory cortex with 7 T MRI
Schluppeck, D., Sánchez-Panchuelo, R.-M., & Francis, S. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.081 · Cited by 33
“…it is possible to shorten the dynamic scan time of 2D-EPI sequences, while maintaining high spatial resolution, using multiplex techniques (Simultaneous MultiSlice (SMS) or Multiband imaging) where multiple slices are simultaneously excited and sampled (Feinberg et al., 2010, Moeller et al., 2010).”
Cross-population myelination covariance of human cerebral cortex
Ma, Z., & Zhang, N. (2017) · Human Brain Mapping · doi:10.1002/hbm.23698 · Cited by 35
“1 ms, flip angle 5 528, FOV 5 208 3 180 mm(2), matrix size 5 104 3 90, voxel size 5 2 3 2 3 2 mm(3), slice number 5 72, slice thickness 5 2 mm, multiband factor 5 8 [Feinberg et al., 2010; Glasser et al., 2013; Moeller et al., 2010; Setsompop et al., 2012].”
InfluentialGundlach, C., Müller, M. M., Hoff, M., Ragert, P., Nierhaus, T., Villringer, A., & Sehm, B. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117175 · Cited by 35
Imaging the temporal dynamics of brain states with highly sampled fMRI
Yang, Z., & Lewis, L. D. (2021) · Current Opinion in Behavioral Sciences · doi:10.1016/j.cobeha.2021.02.005 · Cited by 35
A size‐adaptive 32‐channel array coil for awake infant neuroimaging at 3 Tesla MRI
Ghotra, A., Kosakowski, H. L., Takahashi, A., Etzel, R., May, M. W., Scholz, A., Jansen, A., Wald, L. L., Kanwisher, N., Saxe, R. R., et al. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28791 · Cited by 35
McColgan, P., Helbling, S., Vaculčiaková, L., Pine, K., Wagstyl, K., Attar, F. M., Edwards, L., Papoutsi, M., Wei, Y., van den Heuvel, M. P., et al. (2021) · Human Brain Mapping · doi:10.1002/hbm.25595 · Cited by 34
Self-modulation of motor cortex activity after stroke: a randomized controlled trial
Sanders, Z., Fleming, M. K., Smejka, T., Marzolla, M. C., Zich, C., Rieger, S. W., Lührs, M., Goebel, R., Sampaio‐Baptista, C., & Johansen‐Berg, H. (2022) · Brain · doi:10.1093/brain/awac239 · Cited by 36
Ultrafast inverse imaging techniques for fMRI
Lin, F., Tsai, K. W., Chu, Y.-H., Witzel, T., Nummenmaa, A. R., Raij, T., Ahveninen, J., Kuo, W., & Belliveau, J. W. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.072 · Cited by 39
Wang, F., Bilgiç, B., Dong, Z., Manhard, M. K., Ohringer, N. A., Zhao, B., Haskell, M. W., Cauley, S., Fan, Q., Witzel, T., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27196 · Cited by 34
Modality-specific effects of aversive expectancy in the anterior insula and medial prefrontal cortex
Sharvit, G., Corradi‐Dell’Acqua, C., & Vuilleumier, P. O. (2018) · Pain · doi:10.1097/j.pain.0000000000001237 · Cited by 37
Multisite reliability and repeatability of an advanced brain MRI protocol
Schwartz, D. L., Tagge, I., Powers, K., Ahn, S., Bakshi, R., Calabresi, P. A., Constable, R. T., Grinstead, J. W., Henry, R. G., Nair, G., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26652 · Cited by 35
“02); overall within- and across-site spatial SNR was extremely stable (r (26) = 0.”
BackgroundSchiavi, S., Palombo, M., Zacà, D., Tazza, F., Lapucci, C., Castellan, L., Costagli, M., & Inglese, M. (2023) · Human Brain Mapping · doi:10.1002/hbm.26416 · Cited by 32
“We implemented a protocol based on a prototype PGSE sequence (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013) ).”
MethodAso, T., Jiang, G., Urayama, S.-I., & Fukuyama, H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00256 · Cited by 36
“For the reproducibility study, T2-weighted echo-planar images were acquired using multiband gradientecho echo-planar imaging (EPI; Feinberg et al., 2010) with the following parameters to cover the entire cerebrum and dorsal part of the cerebellum: 64 × 64 pixels, interleaved 28 slices; 224-mm field of view (FOV); 4 mm…”
BackgroundMethodInfluentialStratification of MDD and GAD patients by resting state brain connectivity predicts cognitive bias
Bijsterbosch, J. D., Ansari, T. L., Smith, S. M., Gauld, O. M., Zika, O., Boessenkool, S., Browning, M. D., Reinecke, A., & Bishop, S. J. (2018) · NeuroImage Clinical · doi:10.1016/j.nicl.2018.04.033 · Cited by 35
“A whole-brain multiband EPI sequence was used (790 volumes, acceleration factor 6, TR 1140ms, TE 40ms, flip angle 66°, 66 slices, 2× 2×2mm voxel size), (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012).”
Self-citationBlakemore, R. L., Rieger, S. W., & Vuilleumier, P. O. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.029 · Cited by 32
“Functional images were acquired using a fast multiplexed echo-planar image (EPI) sequence (Feinberg et al., 2010) optimised for blood-oxygen-level dependent contrast (TR = 650 ms, TE = 30 ms, flip angle = 50°, 36 interleaved slices, 64 × 64 pixels, isotropic voxel size of 3 mm 3 , and 3.9 mm slice…”
InfluentialSmith, A. P. R., Luyt, K., Heep, A., & Kauppinen, R. A. (2015) · Human Brain Mapping · doi:10.1002/hbm.22786 · Cited by 34
“The employment of multiband echoplanar imaging (EPI) and robust rs-fMRI acquisition protocols improves temporal resolution and robustness of resting state networks [Feinberg et al., 2010], and allows effective characterisation of higher frequency fluctuations than has previously been possible [Boubela et al.”
BackgroundMethodClos, M., Bunzeck, N., & Sommer, T. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.0495-19.2019 · Cited by 32
“…echo-planar imaging with parallel imaging]GRAPPA (Griswold et al., 2002), in-plane acceleration factor 2] and simultaneous multi-slice acquisitions (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Xu et al., 2013; “multiband,” slice acceleration factor 2; TR 1.98 s, TE 26 ms,…”
BackgroundInfluentialGrid-like entorhinal representation of an abstract value space during prospective decision making
Nitsch, A., Garvert, M. M., Bellmund, J. L. S., Schuck, N. W., & Doeller, C. F. (2024) · Nature Communications · doi:10.1038/s41467-024-45127-z · Cited by 37
“After a localizer scan, functional scans (fMRI) for the picture viewing task and the four runs of the prospective decision making task were acquired using T2*-weighted whole-brain gradientecho echo planar imaging (GE-EPI) with multiband acceleration, sensitive to blood-oxygenlevel-dependent (BOLD) contrast (Feinberg e…”
Intensity‐related distribution of sweet and bitter taste fMRI responses in the insular cortex
Canna, A., Prinster, A., Cantone, E., Ponticorvo, S., Russo, A. G., Salle, F. D., & Esposito, F. (2019) · Human Brain Mapping · doi:10.1002/hbm.24621 · Cited by 34
Kampa, M., Schick, A., Sebastian, A., Wessa, M., Tüscher, O., Kalisch, R., & Yuen, K. S. L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116223 · Cited by 34
“…for Magnetic Resonance Research, University of Minnesota (CMRR) adopted from the Human Connectome Project was used for blood oxygen-level dependent (BOLD) (Feinberg et al., 2010) fMRI. fMRI was complemented by a T1-MPRAGE-sequence (TR¼ 1900ms, TE¼ 2.52ms, flip angle¼ 9 , FOV¼ 250mm, voxel size¼ 1…”
InfluentialNeural oscillations in human auditory cortex revealed by fast fMRI during auditory perception
Frühholz, S., Trost, W. J., Grandjean, D., & Belin, P. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116401 · Cited by 31
Bhandari, R., Kirilina, E. P., Caan, M. W. A., Suttrup, J., Sanctis, T. D., Angelis, L. D., Keysers, C., & Gazzola, V. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116731 · Cited by 32
Neural substrates of shared visual experiences: a hyperscanning fMRI study
Yoshioka, A., Tanabe, H. C., Sumiya, M., Nakagawa, E., Okazaki, S., Koike, T., & Sadato, N. (2021) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsab082 · Cited by 33
“Image preprocessing procedures and statistical analysis were performed using Statistical Parametric Mapping (SPM)12 revision 6685 (Wellcome Centre for Human Neuroimaging, London, UK) implemented in MATLAB 2015a (Mathworks, Natick, MA, USA).”
MethodA third somatomotor representation in the human cerebellum
Saadon‐Grosman, N., Angeli, P. A., DiNicola, L. M., & Buckner, R. L. (2022) · Journal of Neurophysiology · doi:10.1152/jn.00165.2022 · Cited by 34
Simultaneous orthogonal plane imaging
Mickevicius, N. J., & Paulson, E. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26555 · Cited by 31
Bozkurt, B., Yağmurlu, K., Middlebrooks, E. H., Caycı, Z., Çevik, O. M., Karadağ, A., Moen, S. L., Tanrıöver, N., & Grande, A. W. (2017) · Journal of Visualized Experiments · doi:10.3791/55681 · Cited by 37
Barch, D. M. (2017) · Harvard Review of Psychiatry · doi:10.1097/hrp.0000000000000166 · Cited by 33
Slice-level diffusion encoding for motion and distortion correction
Hutter, J. M., Christiaens, D., Schneider, T., Cordero‐Grande, L., Slator, P. J., Deprez, M., Price, A. N., Tournier, J., Rutherford, M., & Hajnal, J. V. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.06.008 · Cited by 33
“…spin-echo with reversed phase enoding at each ssEPI shot ( Section 2.4 ) provides data usable for disortion correction for each individual slice ( Gallichan et al., 2010 ). he combination of these elements ensures that there can be ow- b information suitable for distortion and motion…”
BackgroundMethodInfluentialIdentifying Respiration-Related Aliasing Artifacts in the Rodent Resting-State fMRI
Pais‐Roldán, P., Biswal, B. B., Scheffler, K., & Yu, X. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00788 · Cited by 31
Advances in High-Field BOLD fMRI
Barth, M., & Poser, B. A. (2011) · Materials · doi:10.3390/ma4111941 · Cited by 41
“4 s, great improving the statistical power of fMRI analyses [63].”
BackgroundMethodWang, X., Jiao, Y., Tang, T., Wang, H., & Lu, Z. (2013) · Neuroscience · doi:10.1016/j.neuroscience.2013.09.009 · Cited by 30
“Resting fMRI acquired by fast sampling sequences were recently developed methods to probe brain activity with high temporal resolution (Feinberg et al., 2010; Moeller et al., 2010; Smith et al., 2012).”
Insula-cingulate structural and functional connectivity: an ultra-high field MRI study
Cormie, M. A., Kaya, B., Hadjis, G. E., Mouseli, P., & Moayedi, M. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad244 · Cited by 31
Baron, C. A., & Beaulieu, C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25226 · Cited by 33
Vasylechko, S., Malamateniou, C., Nunes, R. G., Fox, M. J., Allsop, J. M., Rutherford, M., Rueckert, D., & Hajnal, J. V. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25299 · Cited by 33
Neuronal bases of structural coherence in contemporary dance observation
Bachrach, A., Jola, C., & Pallier, C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.072 · Cited by 42
“Then, functional scans were acquired using a rapid Echo-Planar sequence developed at the Center for Magnetic Resonance Research of the University of Minnesota (Feinberg et al., 2010; Xu et al., 2013), with the following parameters: Time of repetition (TR) = 2.3 s; TE = 23 ms; voxel size = 1,5 × 1,5 × 1,5 mm; 82 axial…”
MethodInfluentialIvanov, D., Poser, B. A., Huber, L., Pfeuffer, J., & Uludaǧ, K. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26351 · Cited by 30
“Simultaneous multi-slice imaging (see review in (15)) has demonstrated, for example, improvements for the detection of resting-state networks (7) and dramatically reduced imaging time in diffusion-weighted imaging (16).”
Background
Metadata
- Authors
- Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
- Affiliations
- University of California, San Francisco (US)
- University of Minnesota (US)
- John Radcliffe Hospital (GB)
- Advanced MRI Technologies (United States) (US)
- Washington University in St. Louis (US)
- Corresponding author
- Feinberg, David A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 12
- Pages
- e15710
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3004955
- OpenAlex
- W2114809469
- Cited by
- 1,296
- References
- 57
- Citations by year
- 2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
- FWCI
- 44.96
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-09-28)
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
- W. M. Keck Foundation
- National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
- National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
- National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
- National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
- NIH Blueprint for Neuroscience Research (1U54-MH-091657)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
- MeSH terms
- Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.