Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“and also increase the information content of the data (e.g., in terms of reflecting the richness of the neural dynamics) [41, 42]”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
In the citing paper
“This efficiency increase can lead to substantially improved functional SNR (Feinberg et al., 2010; (Smith et al., 2011), the ability to acquire more diffusion data points (Sotiropoulos et al., 2013c), and/or increases in spatial resolution for fMRI or dMRI (Ugurbil et al. 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“The most significant pulse sequence development for the HCP was the implementation and optimization of slice-accelerated multiband (MB) acquisitions for fMRI and dMRI (Larkman et al., 2001; Moeller et al., 2008; Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Ugurbil et al., 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“Higher temporal resolution of the fMRI data can improve overall statistical sensitivity”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“Analysis was carried out using FSL (FMRIB’s Software Library) [51,52].”
MethodSelf-citationFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“The mean (over time) image was brain-extracted using BET [54].”
MethodSelf-citationFunctional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205 · cited 2×
“Multi-acquisition RSN analysis RSNs and structured artifacts in the data were identified using MELODIC (Multivariate Exploratory Linear Optimized Decomposition into Independent Components [55], FSL’s implementation of ICA (Independent Component Analysis [56]).”
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialCorrespondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150 · cited 1×
“In addition to carrying out the high-dimensional analyses, we also used a set of 10 spatial maps from another study ([33]; 10 RSNs from 36 subjects) as the dual regression input maps.”
MethodSelf-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
BackgroundOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
Background
Cited by
Items 601–700 of 1,000
Multimodal Imaging Brain Connectivity Analysis (MIBCA) toolbox
Ribeiro, A., Lacerda, L. M., & Ferreira, H. A. (2015) · PeerJ · doi:10.7717/peerj.1078 · Cited by 29
“These techniques are not exclusive for improving structural imaging but also for functional information (Feinberg et al., 2010).”
BackgroundEtzel, J. A., Brough, R. E., Freund, M. C., Kizhner, A., Lin, Y., Singh, M. F., Tang, R., Tay, A., Wang, A., & Braver, T. S. (2022) · Scientific Data · doi:10.1038/s41597-022-01226-4 · Cited by 26
“Functional (BOLD, blood oxygenation level dependent) scans were acquired with CMRR multiband sequences (University of Minnesota Center for Magnetic Resonance Research)(Moeller et al. 2010; Feinberg et al. 2010; Xu et al. 2013), multiband (simultaneous multislice; SMS) factor 4, without in-plane acceleration (iPat = no…”
MethodInfluentialWAND: A multi-modal dataset integrating advanced MRI, MEG, and TMS for multi-scale brain analysis
McNabb, C. B., Driver, I. D., Hyde, V., Hughes, G., Chandler, H. L., Thomas, H., Allen, C. S., Messaritaki, E., Hodgetts, C. J., Hedge, C., et al. (2025) · Scientific Data · doi:10.1038/s41597-024-04154-7 · Cited by 27
High-resolution diffusion kurtosis imaging at 3T enabled by advanced post-processing
Mohammadi, S., Tabelow, K., Ruthotto, L., Feiweier, T., Polzehl, J., & Weiskopf, N. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00427 · Cited by 22
“New developments in simultaneously acquiring multiple imaging slices (e.g., Feinberg et al., 2010; Setsompop et al., 2012) hold the potential for accelerating multi-shell diffusion imaging and thus might allow for both high-resolution and whole-brain coverage in a reasonable acquisition time.”
BackgroundTse, D. H. Y., Wiggins, C. J., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26501 · Cited by 24
“…especially for its ability to significantly accelerate blood-oxygen-level dependent and diffusion-weighted echo planar imaging acquisitions (35–37), where SMS and in-plane accelerations [e.g., SENSE (38) or generalized autocalibrating partially parallel acquisitions (GRAPPA) (39)] work in…”
Ptomey, L. T., Szabo‐Reed, A. N., Martin, L. E., Mayo, M. S., Washburn, R. A., Gorczyca, A. M., Lepping, R. J., Lee, P., Forsha, D. E., Sherman, J. R., et al. (2020) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2020.100607 · Cited by 23
Behavioral Prioritization Enhances Working Memory Precision and Neural Population Gain
Yoo, A. H., Bolaños, A., Hallenbeck, G. E., Rahmati, M., Sprague, T. C., & Curtis, C. E. (2022) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01804 · Cited by 22
“We therefore retained the usable trials from these participants and performed all analyses with data from all participants. fMRI methods MRI acquisition All structural and functional MRI data were acquired on a 3T Siemens Prisma MRI system at the Center for Brain Imaging at New York University, using the CMRR MultiBan…”
MethodCortico-cerebellar audio-motor regions coordinate self and other in musical joint action
Kohler, N., Novembre, G., Gugnowska, K., Keller, P. E., Villringer, A., & Sammler, D. (2022) · Cerebral Cortex · doi:10.1093/cercor/bhac243 · Cited by 24
“Functional images were acquired with a whole-brain multi-band echo-planar imaging sequence (EPI; TR = 2,000 ms, TE = 22 ms, multi-band acceleration factor = 3, 60 axial slices in interleaved order, voxel size = 2.5 mm3, 10% inter-slice gap, flip angle = 80◦, field of view = 204 mm; Feinberg et al. 2010; Moeller et al.…”
MethodInfluentialBerger, P., Friederici, A. D., & Wiesmann, C. G. (2022) · Journal of Neuroscience · doi:10.1523/jneurosci.2235-21.2022 · Cited by 24
Resting-State FMRI Single Subject Cortical Parcellation Based on Region Growing
Blumensath, T., Behrens, T. E. J., & Smith, S. M. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33418-4_24 · Cited by 25
“Data was obtained in the Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN 55455 using the sequences developed in CMRR [9] with financial support from NIH grants U54MH091657, P41RR008079 and P41EB015894”
MethodSelf-citationCorrecting dynamic distortions in 7T echo planar imaging using a jittered echo time sequence
Dymerska, B., Poser, B. A., Bogner, W., Visser, E., Eckstein, K., Cardoso, P. L., Barth, M., Trattnig, S., & Robinson, S. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26018 · Cited by 24
Koopmans, P. J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26179 · Cited by 24
Taron, J., Martirosian, P., Schwenzer, N. F., Erb, M., Kuestner, T., Weiß, J., Othman, M. I. A., Notohamiprodjo, M., Nikolaou, K., & Schraml, C. (2016) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-016-0553-4 · Cited by 24
Silva, R. F., Plis, S., Jing Sui (Beijing Normal University), my correct affiliation is beijing normal university, N. Q. U. O. S. A. T., Pattichis, M. S., Adalı, T., & Calhoun, V. D. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2594945 · Cited by 25
“Continued technological advancements in brain structure and function assessment [15]–[18] have fostered the development of a growing collection of BSS methods and tools.”
Spectral Diversity in Default Mode Network Connectivity Reflects Behavioral State
Craig, M. M., Manktelow, A. E., Sahakian, B. J., Menon, D. K., & Stamatakis, E. A. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01213 · Cited by 22
“…protocols, including multiplex and multiband EPI sequences (Boubela, Kalcher, Nasel, & Moser, 2014; Kalcher et al., 2014; Boubela et al., 2013; Feinberg et al., 2010; Atkinson et al., 2006), that allow for faster TRs and thus higher Nyquist frequencies to further define the role of high…”
BackgroundMethodWhy does language not emerge until the second year?
Cusack, R., Wild, C. J., Zubiaurre‐Elorza, L., & Linke, A. C. (2018) · Hearing Research · doi:10.1016/j.heares.2018.05.004 · Cited by 23
“Multiband acceleration (Feinberg et al., 2010; Xu et al., 2013; Nunes et al., 2006) was used to increase sampling rate and reduce sensitivity to movement (36 slices of 64 (cid:2) 64 matrix size with 3 (cid:2) 3 mm in-plane resolution, and slice thickness 3 mm, multiband factor 4).”
MethodUsing structural connectivity to augment community structure in EEG functional connectivity
Glomb, K., Mullier, E., Carboni, M., Rubega, M., Iannotti, G., Tourbier, S., Seeber, M., Vulliémoz, S., & Hagmann, P. (2020) · Network Neuroscience · doi:10.1162/netn_a_00147 · Cited by 22
Scholz, A., Etzel, R., May, M. W., Mahmutović, M., Tian, Q., Ramos‐Llordén, G., Maffei, C., Bilgiç, B., Witzel, T., Stockmann, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118256 · Cited by 22
“For such 2D acquisitions, slice acceleration enables the xcitation and measurement of multiple slices ( Feinberg et al., 2010; etsompop et al., 2018; 2012 ).”
InfluentialHolper, L., Scholkmann, F., & Seifritz, E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.021 · Cited by 24
Tailby, C., Rayner, G., Wilson, S. J., & Jackson, G. D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.088 · Cited by 22
“Short TR acquisitions (e.g. Feinberg et al., 2010), and/or jittering of stimulus timings (Josephs et al., 1997) would be advantageous in such an extension.”
BackgroundAtypical processing of social anticipation and feedback in borderline personality disorder
Doell, K. C., Olié, E., Courtet, P., Corradi-Dell'Acqua, C., Perroud, N., & Schwartz, S. (2020) · NeuroImage: Clinical · doi:10.1016/j.nicl.2019.102126 · Cited by 21
“Functional images were acquired using a multiplexed EPI sequence (Feinberg et al., 2010) with repetition time (TR)=650 ms, echo time (TE)=30 ms, flip angle=50°, 36 slices, 64 × 64 pixels, voxel size=3 × 3 × 3 mm.”
MethodHaenelt, D., Trampel, R., Nasr, S., Polimeni, J. R., Tootell, R. B. H., Sereno, M. I., Pine, K., Edwards, L., Helbling, S., & Weiskopf, N. (2023) · eLife · doi:10.7554/elife.78756 · Cited by 24
Multiband acquisition sequences for fMRI: Proceed with caution
Wall, M. B. (2023) · Aperture Neuro · doi:10.52294/001c.91292 · Cited by 24
Whispering - The hidden side of auditory communication
Frühholz, S., Trost, W. J., & Grandjean, D. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.023 · Cited by 21
“T SIEMENS Trio® TIM System (Siemens, Erlangen, Germany) by using a T2*-weighted multiplexed echoplanar imaging sequence (Feinberg et al., 2010) with an acceleration factor of four.”
Enhanced subject-specific resting-state network detection and extraction with fast fMRI
Akın, B., Lee, H., Hennig, J., & LeVan, P. (2016) · Human Brain Mapping · doi:10.1002/hbm.23420 · Cited by 21
“This had already been noted in a single subject using the multiband EPI sequence and EVI [Feinberg et al., 2010; Posse et al., 2013], and we show here that this result is applicable and reproducible in a group.”
BackgroundMethodInfluentialSingh, V., Pfeuffer, J., Zhao, T., & Ress, D. B. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26845 · Cited by 20
Dual regression physiological modeling of resting-state EPI power spectra: Effects of healthy aging
Viessmann, O., Möller, H. E., & Jezzard, P. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.011 · Cited by 21
“, 1999)) and through-plane (simultaneous multi-slice (SMS)/multiband (Moeller et al., 2010; Feinberg et al., 2010; Feinberg and Setsompop, 2013)) acceleration, repetition times (TR) can be reduced to a few hundreds of milliseconds whilst still achieving reasonable coverage and spatial resolution.”
BackgroundMethodInfluentialOptimizing maternal fat suppression with constrained image‐based shimming in fetal MR
Gaspar, A. S., Nunes, R. G., Ferrazzi, G., Hughes, E., Hutter, J. M., Malik, S., McCabe, L., Baruteau, K. P., Rutherford, M., Hajnal, J. V., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27375 · Cited by 21
Franssen, S., Jansen, A. T. M., van den Hurk, J., Roebroeck, A. F., & Roefs, A. (2020) · Appetite · doi:10.1016/j.appet.2020.104609 · Cited by 23
Sen, B., Bernstein, G. A., Mueller, B. A., Cullen, K. R., & Parhi, K. K. (2020) · NeuroImage Clinical · doi:10.1016/j.nicl.2020.102208 · Cited by 26
Thai, M., Başgöze, Z., Klimes‐Dougan, B., Mueller, B. A., Fiecas, M. J. A., Lim, K. O., Albott, C. S., & Cullen, K. R. (2020) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2020.00820 · Cited by 21
“We utilized a multiband echo planar imaging (MB-EPI) sequence to improve the spatial and temporal resolution of the acquired fMRI data over conventional methods (46).”
MethodSinha, N., Berg, C. N., Yassa, M. A., & Gluck, M. A. (2020) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2020.107340 · Cited by 24
The Core Brain Region for Face Processing in Schizophrenia Lacks Face Selectivity
Maher, S. M., Ekstrom, T., Holt, D. J., Öngür, D., & Chen, Y. (2015) · Schizophrenia Bulletin · doi:10.1093/schbul/sbv140 · Cited by 23
Harmonization of diffusion MRI data sets with adaptive dictionary learning
St‐Jean, S., Viergever, M. A., & Leemans, A. (2020) · Human Brain Mapping · doi:10.1002/hbm.25117 · Cited by 22
López Pérez, D., Bokde, A. L. W., & Kerskens, C. M. (2023) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-022-00696-2 · Cited by 20
Feature-Based Attention Multiplicatively Scales the fMRI-BOLD Contrast-Response Function
Foster, J. J., & Ling, S. (2022) · Journal of Neuroscience · doi:10.1523/jneurosci.0513-22.2022 · Cited by 21
Denoising diffusion weighted imaging data using convolutional neural networks
Cheng, H., Vinci‐Booher, S., Wang, J., Caron, B. A., Wen, Q., Newman, S. D., & Pestilli, F. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274396 · Cited by 23
“The first application aims to reduce noise associated with GRAPPA [35]; the second application aims to reduce noise associated with simultaneous multi-slice acquisition (SMS) [36, 37].”
BackgroundMethodLiao, C., Yarach, U., Cao, X., Iyer, S., Wang, N., Kim, T. H., Tian, Q., Bilgiç, B., Kerr, A. B., & Setsompop, K. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120168 · Cited by 24
“Compared to the 2D and simultaneous multi-slice (SMS) acquisitions (Feinberg et al., 2010; Larkman et al., 2001; Setsompop et al., 2012), the 3D multi-slab acquisition has higher SNR efficiency with short TR (Engström et al.”
Jiang, W., Cai, L., & Wang, Z. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02932-w · Cited by 22
“Each run was acquired using the same multi-band sequence [37] and included 1200 timepoints.”
Trying Harder: How Cognitive Effort Sculpts Neural Representations during Working Memory
Master, S. L., Li, S., & Curtis, C. E. (2024) · Journal of Neuroscience · doi:10.1523/jneurosci.0060-24.2024 · Cited by 28
“The experimental and retinotopic mapping tasks were imaged using the CMRR MultiBand (MB) Accelerated EPI Pulse Sequences (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013).”
Akram, A. S., Grezenko, H., Singh, P., Ahmed, M., Hassan, B. D., Anand, V. H., Elashry, A. R., Nazir, F., & Khan, R. (2024) · Cureus · doi:10.7759/cureus.61335 · Cited by 28
“Simultaneous multi-slice imaging is one technique that has been demonstrated to shorten functional MRI acquisition times by up to 60%, improving the ability to identify minute changes in functional connectivity in the early stages of AD [33].”
BackgroundRolls, E. T., Feng, J., & Zhang, R. (2024) · Brain Structure and Function · doi:10.1007/s00429-024-02811-6 · Cited by 22
“A multi-band acceleration factor of 8 was used during image acquisition (Feinberg et al. 2010; Moeller et al. 2010).”
Chakhoyan, A., Leu, K., Pope, W. B., Cloughesy, T. F., & Ellingson, B. M. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5433 · Cited by 20
Aso, T., Urayama, S., Fukuyama, H., & Murai, T. (2019) · PLoS ONE · doi:10.1371/journal.pone.0222787 · Cited by 23
Seidel, P., Levine, S. M., Tahedl, M., & Schwarzbach, J. V. (2020) · Scientific Reports · doi:10.1038/s41598-020-62590-y · Cited by 21
Gong, N., Dibb, R., Pletnikov, M. V., Benner, E. J., & Liu, C. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4365 · Cited by 21
Amygdala Activation in Cognitive Task fMRI Varies with Individual Differences in Cognitive Traits
West, H. V., Burgess, G. C., Dust, J., Kandala, S., & Barch, D. M. (2021) · Cognitive Affective & Behavioral Neuroscience · doi:10.3758/s13415-021-00863-3 · Cited by 24
Occipital Intralobar fasciculi: a description, through tractography, of three forgotten tracts
Bugain, M., Dimech, Y., Torzhenskaya, N., de Schotten, M. T., Caspers, S., Muscat, R., & Bajada, C. J. (2021) · Communications Biology · doi:10.1038/s42003-021-01935-3 · Cited by 20
Fagundes, J., Longo, M. G. F., Huang, S. Y., Rosen, B. R., Witzel, T., Heberlein, K., González, R. G., Schaefer, P. W., & Rapalino, O. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5293 · Cited by 20
Yun, S. D., & Shah, N. J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184759 · Cited by 23
Stäb, D., & Speier, P. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27356 · Cited by 20
Neural modelling of the semantic predictability gain under challenging listening conditions
Rysop, A. U., Schmitt, L., Obleser, J., & Hartwigsen, G. (2020) · Human Brain Mapping · doi:10.1002/hbm.25208 · Cited by 20
“…in one continuous run with a 3 Tesla Siemens Prisma Scanner and 32-channel head coil, using a dual gradient-echo planar imaging multiband sequence (Feinberg et al., 2010) with the following scanning parameters: TR = 2,000 ms; TE = 12 ms, 33 ms; flip angle = 90°; voxel size = 2.5 x 2.5 x 2.5 mm…”
MethodInfluentialFrydman, L. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.01.013 · Cited by 21
Marques, P., Soares, J. M., Alves, V., & Sousa, N. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00794 · Cited by 23
Schulz, C. C., von Klitzing, K., Deserno, L., Sheridan, M. A., Crowley, M. J., Schoett, M. J. S., Hoffmann, F., Villringer, A., Vrtička, P., & White, L. O. (2022) · Development and Psychopathology · doi:10.1017/s0954579421001681 · Cited by 22
“…planar imaging (GE-EPI) with multiband acceleration (acceleration factor 3) was employed to acquire functional images (TR= 2000 ms, TE= 22 ms, flip angle= 80°, FoV = 204 mm, voxel size: 2.5 × 2.5 × 2.5 mm, interslice gap: 0.25mm, 60 slices (interleaved); Feinberg et al., 2010;Moeller et al., 2010).”
InfluentialShah, N. J. (2014) · Brain Structure and Function · doi:10.1007/s00429-014-0843-4 · Cited by 20
“These methods can provide whole-brain coverage in as little as 0.8 s (Feinberg et al. 2010).”
BackgroundMethodInfluentialSimultaneous multi-slice inverse imaging of the human brain
Hsu, Y.-C., Chu, Y.-H., Tsai, S., Kuo, W., Chang, C., & Lin, F. (2017) · Scientific Reports · doi:10.1038/s41598-017-16976-0 · Cited by 20
Quenching of spontaneous fluctuations by attention in human visual cortex
Broday-Dvir, R., Grossman, S., Furman‐Haran, E., & Malach, R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.089 · Cited by 19
“…three subjects were acquired using a 32 channels head matrix coil (Siemens) as part of a pilot using a multi band echo planar imaging sequence (Feinberg et al., 2010; Moeller et al., 2010) (TR¼ 1000ms, TE¼ 30ms, flip angle¼ 60 , multi-band acceleration factor¼ 2, FOV 216mm, voxel size 3 3…”
Nishida, S., Aso, T., Takaya, S., Takahashi, Y., Kikuchi, T., Funaki, T., Yoshida, K., Okada, T., Kunieda, T., Togashi, K., et al. (2018) · Neurosurgery · doi:10.1093/neuros/nyy434 · Cited by 19
Long-Range Auditory Functional Connectivity in Hearing Loss and Rehabilitation
Ponticorvo, S., Manara, R., Pfeuffer, J., Cappiello, A., Cuoco, S., Pellecchia, M. T., Troisi, D., Scarpa, A., Cassandro, E., Salle, F. D., et al. (2021) · Brain Connectivity · doi:10.1089/brain.2020.0814 · Cited by 20
“…a 3D T1-weighted anatomical sequence, a 3D-PCASL sequence (Dai et al., 2008, 2012; Detre et al., 2012; Wu et al., 2007), and a resting-state BOLD (T2*- weighted) multiband accelerated echo-planar (MB-EPI) fMRI sequence (rs-fMRI) (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013).”
Tepfer, L. J., Alloy, L. B., & Smith, D. V. (2021) · Depression and Anxiety · doi:10.1002/da.23143 · Cited by 19
Manhard, M. K., Stockmann, J., Liao, C., Park, D. J., Han, S., Fair, M. J., van den Boomen, M., Polimeni, J. R., Bilgiç, B., & Setsompop, K. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28761 · Cited by 20
Lehmann, N., Villringer, A., & Taubert, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-05145-7 · Cited by 26
Wackerhagen, C., Veer, I. M., van Leeuwen, J. M. C., Reppmann, Z. C., Riepenhausen, A., Bögemann, S. A., Mor, N., Puhlmann, L. M. C., Uściƚko, A., Zerban, M., et al. (2023) · JMIR Research Protocols · doi:10.2196/39817 · Cited by 22
“0 mm, 72 slices, multiband acceleration factor=8, and phase-encoding direction=posterior to anterior [PA]) from the Center for Magnetic Resonance Research, University of Minnesota, as adopted from the Human Connectome Project, were used for blood oxygen–level dependent fMRI [84].”
MethodKanayet, F. J., Mattarella-Micke, A., Kohler, P. J., Norcia, A. M., McCandliss, B. D., & McClelland, J. L. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01199 · Cited by 23
Disentangling common from specific processing across tasks using task potency
Chauvin, R. J., Mennes, M., Llera, A., Buitelaar, J. K., & Beckmann, C. F. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.059 · Cited by 20
“To allow comparing connectivity values between acquisitions and to account for potential differences in temporal degrees-of freedom due to scan length differences, we normalized the distribution of connectivity values within each connectivity matrix using a mixture-modelling approach (Beckmann et al., 2005; Bielczyk e…”
MethodBoylan, M. R., Panitz, C., Tebbe, A., Vieweg, P., Forschack, N., Müller, M. M., & Keil, A. (2023) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_02030 · Cited by 19
“A whole-brain T2*-weighted multiplexed EPI sequence (Feinberg et al., 2010) of 2 × 2 × 2.5 mm resolution with a multiband acceleration factor of 3 was acquired in an odd–even interleaved fashion (60 slices, echo time = 23msec, TR=2000msec, flip angle=90°, distance factor= 10%, field of view = 192…”
MethodInfluentialSENSE reconstruction for multiband EPI including slice‐dependent N/2 ghost correction
Hennel, F., Buehrer, M., von Deuster, C., Seuwen, A., & Pruessmann, K. P. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25915 · Cited by 18
“Reconstruction, programmed in Matlab (MathWorks, Natick, MA), consisted of a least-squares-inversion of [4] with values of ghost correction measured for both slices.”
MethodFast imaging for mapping dynamic networks
LeVan, P., Akın, B., & Hennig, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.029 · Cited by 19
“Alternatively, a popular approach is the use of simultaneous multi-slice (SMS) excitations (Feinberg et al., 2010; Moeller et al., 2010), which superimpose multiple 2D slice excitations in a single pulse.”
BackgroundApplications of Resting State Functional MR Imaging to Neuropsychiatric Diseases
Pearlson, G. D. (2017) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2017.06.005 · Cited by 18
Aue, T., Guex, R., Chauvigné, L. A. S., Okon‐Singer, H., & Vuilleumier, P. O. (2019) · Emotion · doi:10.1037/emo0000496 · Cited by 21
Bouyagoub, S., Dowell, N. G., Gabel, M. C., & Cercignani, M. (2020) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-020-00897-7 · Cited by 19
Evaluation of SLIce Dithered Enhanced Resolution Simultaneous MultiSlice (SLIDER-SMS) for human fMRI
Vu, A. T., Beckett, A. J. S., Setsompop, K., & Feinberg, D. A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.001 · Cited by 19
“This is undesirable due to the relatively low SNR efficiency (Feinberg et al., 2010; Smith et al., 2013; Xu et al., 2013) and loss of high temporal frequency BOLD information (Chang et al., 2013; Chen et al., 2015; Vu et al., 2016).”
Self-citationClinical Robustness of Accelerated and Optimized Abdominal Diffusion-Weighted Imaging
Taron, J., Weiß, J., Martirosian, P., Seith, F., Stemmer, A., Bamberg, F., & Notohamiprodjo, M. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000370 · Cited by 18
Viessmann, O., Möller, H. E., & Jezzard, P. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.061 · Cited by 18
“Cardiac phase mapping: single-echo EPI Multiband EPI (Moeller et al., 2010; Feinberg et al., 2010; Xu et al., 2013): TR ¼ 334 ms; TE ¼ 26 ms; inter-echo spacing in EPI echo train ¼ 0.68 ms; α ¼ 33 ; multiband factor ¼ 6; GRAPPA factor ¼ 2; BW ¼ 1852 Hz/px; nominal resolution: 2.2 2.2 2.2 mm3; FOVread ¼ 200 mm; FOVphas…”
BackgroundMethodInfluentialMcDowell, A. R., & Carmichael, D. W. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27498 · Cited by 19
“13 Therefore, the 4 imaging sessions were analyzed with 4 different AR models; (1) SPM AR(1), (2) SPM AR(fast), (3) fMRIstat AR(1), and (4) fMRIstat AR(5).”
BackgroundMethodLiu, X., Hildebrandt, A., Meyer, K., Sommer, W., & Zhou, C. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116229 · Cited by 18
Age-Related Differences in Auditory Cortex Activity During Spoken Word Recognition
Rogers, C. S., Jones, M. S., McConkey, S. M., Spehar, B., Engen, K. J. V., Sommers, M. S., & Peelle, J. E. (2020) · Neurobiology of Language · doi:10.1162/nol_a_00021 · Cited by 19
Safety and data quality of EEG recorded simultaneously with multi-band fMRI
Egan, M. K., Larsen, R. J., Wirsich, J., Sutton, B. P., & Sadaghiani, S. (2021) · PLoS ONE · doi:10.1371/journal.pone.0238485 · Cited by 18
Morin, T., Moore, K. N., Isenburg, K., Ma, W., & Stern, C. E. (2022) · Cerebral Cortex · doi:10.1093/cercor/bhac457 · Cited by 18
Multi-echo acquisition and thermal denoising advances precision functional imaging
Moser, J., Nelson, S. M., Koirala, S., Madison, T. J., Labonte, A. K., Carrasco, C. M., Feczko, E., Moore, L. A., Lundquist, J. T., Weldon, K. B., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00426 · Cited by 24
“ME sequence (Feinberg et al., 2010; Moeller et al., 2010) with 5 echoes at WashU and 4 echoes at UMN - dropping the last echo based on compatibility issues with Siemens XA30 (14.2ms, 38.93ms, 63.66ms, 88.39ms, 113.12ms; TR = 1.761s, 2mm resolution, MB factor = 6, IPAT = 2, flip angle = 68°).”
MethodSelf-citationEstimation of the CSA‐ODF using Bayesian compressed sensing of multi‐shell HARDI
Duarte‐Carvajalino, J. M., Lenglet, C., Xu, J., Yacoub, E. S., Uǧurbil, K., Moeller, S., Carin, L., & Sapiro, G. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25046 · Cited by 17
“[6], explaining the auxiliary variable g 61⁄4 0 in Eq.”
BackgroundSelf-citationBiased and unbiased perceptual decision-making on vocal emotions
Dricu, M., Ceravolo, L., Grandjean, D., & Frühholz, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-16594-w · Cited by 17
MRI-based visualization of rTMS-induced cortical plasticity in the primary motor cortex
Tamura, K., Osada, T., Ogawa, A., Tanaka, M., Suda, A., Shimo, Y., Hattori, N., Kamagata, K., Hori, M., Aoki, S., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0224175 · Cited by 19
“Functional images were obtained using multi-band gradient-echo echo-planar sequences [56] (TR = 1.”
MethodSubject‐specific segregation of functional territories based on deep phenotyping
Pinho, A. L., Amadon, A., Fabre, M., Dohmatob, E., Denghien, I., Torre, J. J., Ginisty, C., Becuwe-Desmidt, S., Roger, S., Laurier, L., et al. (2020) · Human Brain Mapping · doi:10.1002/hbm.25189 · Cited by 18
“FMRI data were collected using a gradient-echo (GE) pulse, wholebrain multiband (MB) accelerated (Feinberg et al., 2010; Moeller et al., 2010) echo-planar imaging (EPI) T2*-weighted sequence with BOLD contrasts, using the following parameters: the repetition time (TR) is 2,000 ms; the echo time…”
MethodUsing connectomics for predictive assessment of brain parcellations
Albers, K. J., Ambrosen, K. S., Liptrot, M. G., Dyrby, T. B., Schmidt, M. N., & Mørup, M. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118170 · Cited by 18
Hill-Bowen, L. D., Riedel, M. C., Salo, T., Flannery, J. S., Poudel, R., Laird, A. R., & Sutherland, M. T. (2022) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2022.109625 · Cited by 20
Jesmanowicz, A., Nencka, A. S., Li, S., & Hyde, J. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0004 · Cited by 17
“A recent communication has also appeared with further technological advances and applications (Feinberg et al., 2010).”
Accelerated fMRI reconstruction using Matrix Completion with Sparse Recovery via Split Bregman
Aggarwal, P., & Gupta, A. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.08.016 · Cited by 17
“One limitation of fMRI is the long scanning time that leads to annoyance in patients resulting in low signal-to-noise ratio (SNR) due to subject’s movement [5].”
BackgroundVu, A. T., Phillips, J. S., Kay, K., Phillips, M. E., Johnson, M. R., Shinkareva, S. V., Tubridy, S., Millin, R., Grossman, M., Gureckis, T. M., et al. (2016) · Cognitive Neuropsychology · doi:10.1080/02643294.2016.1195343 · Cited by 17
“With the recent advancements in multiband (MB) acceleration allowing for sub-second whole-brain imaging (Feinberg et al., 2010; Moeller et al., 2010), determining how much word timing information is available in the BOLD response becomes exceedingly relevant.”
BackgroundSelf-citationPetrov, A. Y., Herbst, M., & Stenger, V. A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.004 · Cited by 17
Weak Higher-Order Interactions in Macroscopic Functional Networks of the Resting Brain
Huang, X., Xu, K., Chu, C., Jiang, T., & Yu, S. P. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.0451-17.2017 · Cited by 19
“Parameters for the resting data were as follows: TR 720 ms, TE 33.1 ms, FA 52°, 2 2 2 mm voxels, FOV 208 180 mm, and 72 oblique axial slices (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Van Essen et al., 2012).”
MethodInfluentialTheyers, A. E., Goldstein, B. I., Metcalfe, A. W. S., Robertson, A. D., & MacIntosh, B. J. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18766771 · Cited by 17
“Blood oxygenation level dependent (BOLD) contrast functional MRI (fMRI) is ideal for measuring pulsatility because of its whole brain coverage and capacity for high temporal resolution.(20,21) BOLD is commonly used as an indirect measure of neuronal activity due to co-localized changes in blood oxygenation.”
BackgroundFeedback contribution to surface motion perception in the human early visual cortex
Marquardt, I., Weerd, P. D., Schneider, M., Gülban, Ö. F., Ivanov, D., Wang, Y., & Uludaǧ, K. (2020) · eLife · doi:10.7554/elife.50933 · Cited by 18
Technological Advances of Magnetic Resonance Imaging in Today's Health Care Environment
Attenberger, U. I., Biber, S., & Wichtmann, B. D. (2020) · Investigative Radiology · doi:10.1097/rli.0000000000000678 · Cited by 19
Midbrain fMRI: Applications, Limitations and Challenges
Düzel, E., Guitart-Masip, M., Maass, A., Hämmerer, D., Betts, M. J., Speck, O., Weiskopf, N., & Kanowski, M. (2015) · Biological Magnetic Resonance · doi:10.1007/978-1-4899-7591-1_20 · Cited by 16
Nyquist ghost correction of breast diffusion weighted imaging using referenceless methods
McKay, J. A., Moeller, S., Zhang, L., Auerbach, E. J., Nelson, M. T., & Bolan, P. J. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27563 · Cited by 16
Self-citationMore complex than you might think: Neural representations of food reward value in obesity
Pimpini, L., Kochs, S., Franssen, S., van den Hurk, J., Valente, G., Roebroeck, A. F., Jansen, A. T. M., & Roefs, A. (2022) · Appetite · doi:10.1016/j.appet.2022.106164 · Cited by 19
Golden, R. K., Sutkus, L. T., Donovan, S. M., & Dilger, R. N. (2024) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2023.1337897 · Cited by 17
“To assess white matter maturation and axonal tract integrity, a diffusion-weighted echo planar imaging (DWI-EPI) sequence was utilized (Feinberg et al., 2010; Moeller et al., 2010; Xu et al., 2013).”
MethodAltered brain perfusion and oxygen levels relate to sleepiness and attention in post‐ COVID syndrome
Chien, C., Heine, J., Khalil, A. A., Schlenker, L., Hartung, T. J., Boesl, F., Schwichtenberg, K., Rust, R., Bellmann–Strobl, J., Franke, C., et al. (2024) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.52121 · Cited by 18
“…Magne-tom PRISMA scanner (Erlangen, Germany) using a 64-channel head coil, including (1) a high-resolution 3D T1-weighted magnetization prepared rapid gradient echo (MPRAGE) and (2) a multiband resting-state fMRI, 18 – 20 and two spin-echo sequences for field map distortion correction (Table 2).”
Method
Metadata
- Authors
- Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
- Affiliations
- University of California, San Francisco (US)
- University of Minnesota (US)
- John Radcliffe Hospital (GB)
- Advanced MRI Technologies (United States) (US)
- Washington University in St. Louis (US)
- Corresponding author
- Feinberg, David A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 12
- Pages
- e15710
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3004955
- OpenAlex
- W2114809469
- Cited by
- 1,296
- References
- 57
- Citations by year
- 2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
- FWCI
- 44.96
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-09-28)
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
- W. M. Keck Foundation
- National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
- National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
- National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
- National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
- NIH Blueprint for Neuroscience Research (1U54-MH-091657)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
- MeSH terms
- Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.