Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Non-invasive wearable biosensors provide real-time, continuous, and actionable health information. However, difficulties detecting diluted biomarkers in excreted biofluids limit practical applications. Most biomarkers of interest are transported paracellularly into excreted biofluids from biomarker-rich blood and interstitial fluid during normal modulation of cellular tight junctions. Calcium chelators are reversible tight junction modulators that have been shown to increase absorption across the intestinal epithelium. However, calcium chelators have not yet been shown to improve the extraction of biomarkers. Here we show that for glucose, a paracellularly transported biomarker, the flux into sweat can be increased by >10x using citrate, a calcium chelator, in combination with electroosmosis. Our results demonstrate a method of increasing glucose flux through the sweat gland epithelium, thereby increasing the concentration in sweat. Future work should examine if this method enhances flux for other paracellularly transported biomarkers to make it possible to detect more biomarkers with currently available biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig 1 Conceptual model for glucose flux under various conditions: Normal, electroosmosis, and chelation with electroosmosis. Normal. Tight junctions undergo constant and spontaneous remodeling. While this can cause direct aqueous paths to form momentarily, the majority of glucose likely diffuses from ISF to sweat between opening and closing compartments that fluctuate between the tight junctional strands. RI + control (acetate). Electroosmosis (enlarged) is the flow of fluid resulting from an applied electric field in the presence of an electrical double layer. The fixed negative charges needed to establish the double layer are due to the carboxylic acid moieties within glycans and proteins on the cell surface. Electroosmosis brings in ISF through the paracellular pathway. RI + chelator (citrate). Chelation triggers reversible endocytosis of tight junctions (enlarged), producing many more direct aqueous paths, which close upon reintroduction of calcium. Therefore, we expect electroosmosis with chelation to facilitate much higher glucose flux compared to electroosmosis alone. Skin model has been adapted [1].](https://figures.cochat.ai/paper-figures/826cfbcfb7e04bdaabab74306264a78a/enhancing-glucose-flux-into-sweat-by-increasing-paracellular-permeability-of-the-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Most studies suggest that blood glucose is the primary source of sweat glucose”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Using citrate, a calcium chelator, Jajack et al. (2018) were able to modify paracellular pathways and found a > 10-fold increase in sweat glucose flux”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“Glucose flux in sweat has been shown to change with the modulation of tight junctions in the sweat gland epithelium”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“its concentration is ~ 100 × lower than that of blood glucose”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revised Estimates for the Number of Human and Bacteria Cells in the Body
Sender, R., Fuchs, S., & Milo, R. (2016) · PLOS Biology · doi:10.1371/journal.pbio.1002533 · Cited by 5,425
Grice, E. A., & Segre, J. A. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2537 · Cited by 3,143
Atopic Dermatitis: Global Epidemiology and Risk Factors
Nutten, S. (2015) · Annals of Nutrition and Metabolism · doi:10.1159/000370220 · Cited by 3,055
Multifunctional strands in tight junctions
Tsukita, S., Furuse, M., & Itoh, M. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35067088 · Cited by 2,509
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Physiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059
Revised estimates for the number of human and bacteria cells in the bodyPreprint
Sender, R., Fuchs, S., & Milo, R. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/036103 · Cited by 888
Crosstalk of tight junction components with signaling pathways
González-Mariscal, L., Tapia, R., & Chamorro, D. (2008) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2007.08.018 · Cited by 759
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationCorrelation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Self-citationPhysiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Gorzelanny, C., Mess, C., Schneider, S. W., Huck, V., & Brandner, J. M. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12070684 · Cited by 229
“[110] showed that flux of biomarkers into sweat (e.”
BackgroundDiving into Sweat: Advances, Challenges, and Future Directions in Wearable Sweat Sensing
Childs, A., Mayol, B., Lasalde-Ramírez, J. A., Song, Y., Sempionatto, J. R., & Gao, W. (2024) · ACS Nano · doi:10.1021/acsnano.4c10344 · Cited by 217
Sempionatto, J. R., Moon, J.-M., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00139 · Cited by 208
Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00555 · Cited by 207
Self-citationBiomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review
Sim, D., Brothers, M. C., Slocik, J. M., Islam, A. E., Maruyama, B., Grigsby, C. C., Naik, R. R., & Kim, S. S. (2022) · Advanced Science · doi:10.1002/advs.202104426 · Cited by 186
Self-citationState of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01133 · Cited by 178
Glove-based sensors for multimodal monitoring of natural sweat
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A. (2020) · Science Advances · doi:10.1126/sciadv.abb8308 · Cited by 154
A wearable freestanding electrochemical sensing system
Zhao, Y., Wang, B., Hojaiji, H., Wang, Z., Lin, S., Yeung, C. J., Lin, H., Nguyen, P., Chiu, K., Salahi, K., et al. (2020) · Science Advances · doi:10.1126/sciadv.aaz0007 · Cited by 150
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114
Francis, J., Stamper, I., Heikenfeld, J., & Gomez, E. F. (2019) · Lab on a Chip · doi:10.1039/c8lc00968f · Cited by 66
Self-citationMini review about metal organic framework (MOF)-based wearable sensors: Challenges and prospects
Meskher, H., Belhouari, S. B., & Sharifianjazi, F. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e21621 · Cited by 63
“The diluting effect brought on by an increase in sweat rate during an extensive exercise, is thought to be responsible for the lower levels of sweat glucose [67,68].”
BackgroundModeling Glucose Transport From Systemic Circulation to Sweat
La Count, T. D., Jajack, A., Heikenfeld, J., & Kasting, G. B. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2018.09.026 · Cited by 60
Self-citationFibers/Textiles-Based Flexible Sweat Sensors: A Review
Zhang, S., Tan, R., Xu, X., Iqbal, S., & Hu, J. (2023) · ACS Materials Letters · doi:10.1021/acsmaterialslett.2c01207 · Cited by 56
Giaretta, J., Zulli, R., Prabhakar, T., Rath, R. J., Naficy, S., Spilimbergo, S., Weiss, P. S., Farajikhah, S., & Dehghani, F. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400065 · Cited by 35
Nanoarchitectonics of point-of-care diagnostics for sweat biomarkers analysis
Lin, X., Vasanth, A., Ashok, A., Phan, H., Koo, K. M., Amin, M. A., Kaneti, Y. V., Salomón, C., Hossain, M. S. A., Yamauchi, Y., et al. (2024) · Nano Materials Science · doi:10.1016/j.nanoms.2024.01.010 · Cited by 30
Tu, L. M. T. P. P. L. M., Thu, V. T. A., Hoang, T. X., Selvam, S. P., Pham, H. L., Kim, J. Y., & Cho, S. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100020 · Cited by 27
Universal Flexible Wearable Biosensors for Noninvasive Health Monitoring
Chen, M., Zhang, J., Ji, G., Wang, H., Zhu, B., Chen, C., Zhou, H., Wang, Y., & Gao, Z. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c22623 · Cited by 28
Ma, L., Hou, W., Ji, Z., Sun, Z., Li, M., & Lian, B. (2024) · ChemistryOpen · doi:10.1002/open.202300217 · Cited by 24
Sheffield, Z., Paul, P., Krishnakumar, S., & Pan, D. (2024) · Advanced Science · doi:10.1002/advs.202411339 · Cited by 28
Review of point-of-care platforms for diabetes: (1) sensing
Liu, Y., Luo, X., Yu, Q., Ye, L., Yang, L., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100113 · Cited by 20
Zhang, Y., Zhang, S., Yang, Y., Tao, L., Yu, F., Song, C., Guo, K., Zhu, J., Lin, Y., Yang, F., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2532127123 · Cited by 19
“As a result, this dilution mechanism results in a lower number of glucose molecules in sweat (only ~ 1% of the glucose in the surrounding ISF) (55).”
InfluentialLiu, L., Zhan, K., Kilpijärvi, J., Kinnunen, M. T., Zhao, Y., Zhang, Y., Yaltaye, M. W., Li, Y., Zhyvolozhnyi, A., Samoylenko, A., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01152-6 · Cited by 22
Elshahat, A., Hasan, A. A., Elghamry, H. A., & Balata, G. F. (2024) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2024.106093 · Cited by 6
Wang, X., Ma, Y., Zeng, M., & Niu, P. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3600238 · Cited by 3
“Sweatcompositionismodulatedbymultiplephysiological andanatomicalfactors,includingthetypeofglandinvolved(ec-crinevs.apocrine)[11],sweatrate[12],andductalreabsorption [13],[14].”
Mei, J., Yang, Q., Tian, M., Deng, S., & Gong, Y. (2026) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2026.03.004 · Cited by 1
Wearable and implantable aptamer sensors for physiological monitoring
Lee, H. B., Lee, D., & Ko, S. H. (2026) · Soft Science · doi:10.20517/ss.2025.149 · Cited by 3
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Self-citationNie, W., Zhuo, L., Liu, J., Cui, H. L., & Jiang, J. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c02025
Transport-Informed Sweat Glucose Sensing Toward Noninvasive Continuous Monitoring
Zhang, S., Zhang, Y., Fl, Y., Liu, Z., Zhong, J., & Cheng, H. (2026) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.6c00993
Maximo, R. T., da Silva, M. G. N. M., Martins, D. B. G., Cavalcante, P. S., Tedesco, P., Belian, R. B., & Yara, R. (2026) · Scientific Electronic Archives · doi:10.36560/19520262251
“Consequently, many biomarkers with potential utility for physiological monitoring may be present in sweat at concentrations below the detection limits of certain biosensors (Jajack et al., 2018).”
Metadata
- Authors
- Jajack, A., Brothers, M., Kasting, G., & Heikenfeld, J.
- Affiliations
- University of Cincinnati (US)
- United States Air Force Research Laboratory (US)
- Corresponding author
- Jajack, Andrew
- Brothers, Michael
- Kasting, Gerald
- Heikenfeld, Jason
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-07-16
- Volume
- 13
- Issue
- 7
- Pages
- e0200009
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC6047769
- OpenAlex
- W2883179762
- Cited by
- 35
- References
- 32
- Citations by year
- 2026: 7 · 2025: 2 · 2024: 6 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 5 · 2018: 2
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Air Force Research Labs (USAF contract #FA8650-16-C-6760)
- Ohio Federal Research Network (PO FY16-049; WSARC-1077-700)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- sweat glucose, paracellular permeability, tight junction modulation, calcium chelators, citrate, electroosmosis, wearable biosensors, non-invasive biomarker detection, sweat biomarkers
- MeSH terms
- Biological Transport, Citrates, Dose-Response Relationship, Drug, Female, Glucose, Humans, Male, Permeability, Sweat, Sweat Glands, Biosensing Techniques, Electroosmosis, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.