Abstract
Non-invasive wearable biosensors provide real-time, continuous, and actionable health information. However, difficulties detecting diluted biomarkers in excreted biofluids limit practical applications. Most biomarkers of interest are transported paracellularly into excreted biofluids from biomarker-rich blood and interstitial fluid during normal modulation of cellular tight junctions. Calcium chelators are reversible tight junction modulators that have been shown to increase absorption across the intestinal epithelium. However, calcium chelators have not yet been shown to improve the extraction of biomarkers. Here we show that for glucose, a paracellularly transported biomarker, the flux into sweat can be increased by >10x using citrate, a calcium chelator, in combination with electroosmosis. Our results demonstrate a method of increasing glucose flux through the sweat gland epithelium, thereby increasing the concentration in sweat. Future work should examine if this method enhances flux for other paracellularly transported biomarkers to make it possible to detect more biomarkers with currently available biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig 1 Conceptual model for glucose flux under various conditions: Normal, electroosmosis, and chelation with electroosmosis. Normal. Tight junctions undergo constant and spontaneous remodeling. While this can cause direct aqueous paths to form momentarily, the majority of glucose likely diffuses from ISF to sweat between opening and closing compartments that fluctuate between the tight junctional strands. RI + control (acetate). Electroosmosis (enlarged) is the flow of fluid resulting from an applied electric field in the presence of an electrical double layer. The fixed negative charges needed to establish the double layer are due to the carboxylic acid moieties within glycans and proteins on the cell surface. Electroosmosis brings in ISF through the paracellular pathway. RI + chelator (citrate). Chelation triggers reversible endocytosis of tight junctions (enlarged), producing many more direct aqueous paths, which close upon reintroduction of calcium. Therefore, we expect electroosmosis with chelation to facilitate much higher glucose flux compared to electroosmosis alone. Skin model has been adapted [1].](https://figures.cochat.ai/paper-figures/826cfbcfb7e04bdaabab74306264a78a/enhancing-glucose-flux-into-sweat-by-increasing-paracellular-permeability-of-the-figure-1.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Most studies suggest that blood glucose is the primary source of sweat glucose”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Using citrate, a calcium chelator, Jajack et al. (2018) were able to modify paracellular pathways and found a > 10-fold increase in sweat glucose flux”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“Glucose flux in sweat has been shown to change with the modulation of tight junctions in the sweat gland epithelium”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“its concentration is ~ 100 × lower than that of blood glucose”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
The cited source says what the claim attributes to it.
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Jajack et al. 2018
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revised Estimates for the Number of Human and Bacteria Cells in the Body
Sender, R., Fuchs, S., & Milo, R. (2016) · PLOS Biology · doi:10.1371/journal.pbio.1002533 · Cited by 5,425
Grice, E. A., & Segre, J. A. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2537 · Cited by 3,143
Atopic Dermatitis: Global Epidemiology and Risk Factors
Nutten, S. (2015) · Annals of Nutrition and Metabolism · doi:10.1159/000370220 · Cited by 3,055
Multifunctional strands in tight junctions
Tsukita, S., Furuse, M., & Itoh, M. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35067088 · Cited by 2,509
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Physiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059
Revised estimates for the number of human and bacteria cells in the bodyPreprint
Sender, R., Fuchs, S., & Milo, R. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/036103 · Cited by 888
Crosstalk of tight junction components with signaling pathways
González-Mariscal, L., Tapia, R., & Chamorro, D. (2008) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2007.08.018 · Cited by 759
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationCorrelation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Cork, M. J., Robinson, D. A., Vasilopoulos, Y., Ferguson, A., Moustafa, M., MacGowan, A., Duff, G. W., Ward, S. J., & Tazi-Ahnini, R. (2006) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2006.04.042 · Cited by 525
Dynamics and functions of tight junctions
Steed, E., Balda, M. S., & Matter, K. (2010) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.12.002 · Cited by 418
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Deli, M. A. (2009) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.09.016 · Cited by 385
Ivanov, A. I., Nusrat, A., & Parkos, C. A. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e03-05-0319 · Cited by 383
Tight junction modulation and its relationship to drug delivery
SALAMA, N., EDDINGTON, N., & FASANO, A. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.003 · Cited by 357
Lindmark, T., Kimura, Y., & Artursson, P. (1998) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)37216-7 · Cited by 333
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Self-citationGlucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
Role of calcium in tight junction formation between epithelial cells
Gonzalez-Mariscal, L., Contreras, R. G., Bolivar, J. J., Ponce, A., Chavez De Ramirez, B., & Cereijido, M. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.259.6.c978 · Cited by 236
Absorption-Enhancing Mechanism of EDTA, Caprate, and Decanoylcarnitine in Caco-2 Cells
Tomita, M., Hayashi, M., & Awazu, S. (1996) · Journal of Pharmaceutical Sciences · doi:10.1021/js9504604 · Cited by 169
A wearable conductivity sensor for wireless real-time sweat monitoring
Liu, G., Ho, C., Slappey, N., Zhou, Z., Snelgrove, S. E., Brown, M., Grabinski, A., Guo, X., Chen, Y., Miller, K., et al. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.034 · Cited by 158
Reverse iontophoresis for non-invasive transdermal monitoring
Leboulanger, B., Guy, R. H., & Delgado-Charro, M. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/3/r01 · Cited by 134
Simmers, P., Li, S. K., Kasting, G. B., & Heikenfeld, J. C. (2017) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2017.10.013 · Cited by 106
Self-citationSHEU, H.-M., CHAO, S.-C., WONG, T.-W., LEE, Y.-Y., & TSAI, J.-C. (1999) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1999.02697.x · Cited by 94
A modified anaerobic method of sweat collection
Boysen, T. C., Yanagawa, S., Sato, F., & Sato, K. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1302 · Cited by 91
Fiume, M. M., Heldreth, B. A., Bergfeld, W. F., Belsito, D. V., Hill, R. A., Klaassen, C. D., Liebler, D. C., Marks, J. G., Shank, R. C., Slaga, T. J., et al. (2014) · International Journal of Toxicology · doi:10.1177/1091581814526891 · Cited by 79
Bhat, M., Toledo‐Velasquez, D., Wang, L., Malanga, C. J., Ma, J. K. H., & Rojanasakul, Y. (1993) · Pharmaceutical Research · doi:10.1023/a:1018906504944 · Cited by 76
Electroanalysis of Glucose in Transcutaneously Extracted Samples
Tierney, M. J., Kim, H. L., Burns, M. D., Tamada, & Potts, R. O. (2000) · Electroanalysis · doi:10.1002/1521-4109(200005)12:9<666::aid-elan666>3.0.co;2-c · Cited by 68
Evaluation of commercial glucometer test strips for potential measurement of glucose in tears
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E. (2014) · Analytical Chemistry · doi:10.1021/ac4040168 · Cited by 67
Peng, R., Sonner, Z., Hauke, A., Wilder, E., Kasting, J., Gaillard, T., Swaille, D., Sherman, F., Mao, X., Hagen, J., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc01013j · Cited by 43
Self-citationSurface contamination artificially elevates initial sweat mineral concentrations
Ely, M. R., Kenefick, R. W., Cheuvront, S. N., Chinevere, T. D., Lacher, C. P., Lukaski, H. C., & Montain, S. J. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01437.2010 · Cited by 38
Increased permeability of intestinal epithelial monolayers mediated by electroporation
Ghartey-Tagoe, E. B., Morgan, J. S., Neish, A. S., & Prausnitz, M. R. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.11.021 · Cited by 18
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Self-citationPhysiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Metadata
- Authors
- Jajack, A., Brothers, M., Kasting, G., & Heikenfeld, J.
- Affiliations
- University of Cincinnati (US)
- United States Air Force Research Laboratory (US)
- Corresponding author
- Jajack, Andrew
- Brothers, Michael
- Kasting, Gerald
- Heikenfeld, Jason
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-07-16
- Volume
- 13
- Issue
- 7
- Pages
- e0200009
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC6047769
- OpenAlex
- W2883179762
- Cited by
- 35
- References
- 32
- Citations by year
- 2026: 7 · 2025: 2 · 2024: 6 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 5 · 2018: 2
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Air Force Research Labs (USAF contract #FA8650-16-C-6760)
- Ohio Federal Research Network (PO FY16-049; WSARC-1077-700)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- sweat glucose, paracellular permeability, tight junction modulation, calcium chelators, citrate, electroosmosis, wearable biosensors, non-invasive biomarker detection, sweat biomarkers
- MeSH terms
- Biological Transport, Citrates, Dose-Response Relationship, Drug, Female, Glucose, Humans, Male, Permeability, Sweat, Sweat Glands, Biosensing Techniques, Electroosmosis, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.