CoChat

Artificial tactile and proprioceptive feedback improves performance and confidence on object identification tasks

Open access
Schiefer, Matthew A., Graczyk, Emily L., Sidik, Steven M., Tan, Daniel W., Tyler, Dustin J. · 2018 · PLOS ONE
Cited by 115

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Somatosensory feedback of the hand is essential for object identification. Without somatosensory feedback, individuals cannot reliably determine the size or compliance of an object. Electrical nerve stimulation can restore localized tactile and proprioceptive feedback with intensity discrimination capability similar to natural sensation. We hypothesized that adding artificial somatosensation improves object recognition accuracy when using a prosthesis. To test this hypothesis, we provided different forms of sensory feedback-tactile, proprioceptive, or both-to two subjects with upper limb loss. The subjects were asked to identify the size or mechanical compliance of different foam blocks placed in the prosthetic hand while visually and audibly blinded. During trials, we did not inform the subjects of their performance, but did ask them about their confidence in correctly identifying objects. Finally, we recorded applied pressures during object interaction. Subjects were free to use any strategy they chose to examine the objects. Object identification was most accurate with both tactile and proprioceptive feedback. The relative importance of each type of feedback, however, depended on object characteristics and task. Sensory feedback increased subject confidence and was directly correlated with accuracy. Subjects applied less pressure to the objects when they had tactile pressure feedback. Artificial somatosensory feedback improves object recognition and the relative importance of tactile versus proprioceptive feedback depends on the test set. We believe this test battery provides an effective means to assess the impact of sensory restoration and the relative contribution of different forms of feedback (tactile vs. kinesthetic) within the neurorehabilitation field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0207659

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 115

Metadata

Authors
Schiefer, M. A., Graczyk, E. L., Sidik, S. M., Tan, D. W., & Tyler, D. J.
Venue
PLOS ONE
Published
2018-12-05
Volume
13
Issue
12
Pages
e0207659
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2902148761
Cited by
115
References
10
FWCI
7.33
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial tactile and proprioceptive feedback improves performance and confidence on object identification tasks. https://app.cochat.ai/papers/10.1371/journal.pone.0207659
The paper
Schiefer, M. A., Graczyk, E. L., Sidik, S. M., Tan, D. W., & Tyler, D. J. (2018). Artificial tactile and proprioceptive feedback improves performance and confidence on object identification tasks. PLOS ONE. https://doi.org/10.1371/journal.pone.0207659

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.