Transportable optical atomic clocks for use in out-of-the-lab environments
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Recently, several reports with a strong focus on compact, nonstationary optical atomic clocks have been published, including accounts of in-field deployment of these devices for demonstrations of chronometric levelling in different types of environments. We review recent progress in this research area, comprising compact and transportable neutral atom and single-ion optical atomic clocks. The identified transportable optical clocks strive for low volume, weight and power consumption while exceeding standard microwave atomic clocks in fractional frequency instability and systematic uncertainty. Some transportable clock projects additionally address requirements for metrology or serve the joint technology development between industrial and academic stakeholders. Based on the reviewed reports on nonstationary optical atomic clocks, we suggest definitions for transportable, portable and mobile optical atomic clocks. We conclude our article with an overview of possible future directions for developments of optical clock technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [26]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Architecture for the photonic integration of an optical atomic clock
Newman, Z. L., Maurice, V., Drake, T., Stone, J. R., Briles, T. C., Spencer, D. T., Fredrick, C., Li, Q., Westly, D., Ilic, B. R., et al. (2019) · Optica · doi:10.1364/optica.6.000680 · Cited by 636
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
The Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationHertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Optical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Barber, Z., Hoyt, C., Oates, C., Hollberg, L., Taichenachev, A., & Yudin, V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.083002 · Cited by 268
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Comparison of Two Independent Sr Optical Clocks with1×10−17Stability at103 s
Nicholson, T. L., Martin, M. J., Williams, J. R., Bloom, B. J., Bishof, M., Swallows, M. D., Campbell, S. L., & Ye, J. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230801 · Cited by 205
A surface-patterned chip as a strong source of ultracold atoms for quantum technologies
Nshii, C. C., Vangeleyn, M., Cotter, J. P., Griffin, P. F., Hinds, E. A., Ironside, C. N., See, P., Sinclair, A. G., Riis, E., & Arnold, A. S. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.47 · Cited by 204
Seconds-scale coherence on an optical clock transition in a tweezer array
Norcia, M. A., Young, A. W., Eckner, W. J., Oelker, E., Ye, J., & Kaufman, A. M. (2019) · Science · doi:10.1126/science.aay0644 · Cited by 185
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
Absolute Frequency Measurement of theCa+404s S1/22−3d D5/22Clock Transition
Chwalla, M., Benhelm, J., Kim, K., Kirchmair, G., Monz, T., Riebe, M., Schindler, P., Villar, A. S., Hänsel, W., Roos, C. F., et al. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.023002 · Cited by 164
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Self-citationAdvances in the accuracy, stability, and reliability of the PTB primary fountain clocks
Weyers, S., Gerginov, V, Kazda, M., Rahm, J., Lipphardt, B., Dobrev, G., & Gibble, K. (2018) · Metrologia · doi:10.1088/1681-7575/aae008 · Cited by 140
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Force-insensitive optical cavity
Webster, S., & Gill, P. (2011) · Optics Letters · doi:10.1364/ol.36.003572 · Cited by 137
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · CRC Press eBooks · doi:10.1201/9781003041085 · Cited by 117
Nondestructive measurement of the transition probability in a Sr optical lattice clock
Lodewyck, J., Westergaard, P. G., & Lemonde, P. (2009) · Physical Review A · doi:10.1103/physreva.79.061401 · Cited by 108
The Dick effect for an optical frequency standard
Quessada, A., Kovacich, R. P., Courtillot, I. N., Clairon, A., Santarelli, G., & Lemonde, P. (2003) · Journal of Optics B: Quantum and Semiclassical Optics · doi:10.1088/1464-4266/5/2/373 · Cited by 104
A transportable strontium optical lattice clock
Poli, N., Schioppo, M., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Applied Physics B · doi:10.1007/s00340-014-5932-9 · Cited by 104
An Atomic-Array Optical Clock with Single-Atom Readout
Madjarov, I. S., Cooper, A., Shaw, A. L., Covey, J. P., Schkolnik, V., Yoon, T. H., Williams, J. R., & Endres, M. (2019) · Physical Review X · doi:10.1103/physrevx.9.041052 · Cited by 104
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
Optical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1902.02741 · Cited by 98
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 94
Self-citationTowards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z. T., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Review of Scientific Instruments · doi:10.1063/1.5090583 · Cited by 76
Mercury Ion Clock for a NASA Technology Demonstration Mission
Tjoelker, R. L., Prestage, J. D., Burt, E. A., Chen, P., Chong, Y. J., Chung, S. K., Diener, W. A., Ely, T., Enzer, D. G., Mojaradi, H., et al. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2543738 · Cited by 71
Chen, Q.-F., Nevsky, A., Cardace, M., Schiller, S., Legero, T., Häfner, S., Uhde, A., & Sterr, U. (2014) · Review of Scientific Instruments · doi:10.1063/1.4898334 · Cited by 69
Optical-Clock-Based Time Scale
Yao, J., Sherman, J. A., Fortier, T., Leopardi, H., Parker, T., McGrew, W., Zhang, X., Nicolodi, D., Fasano, R., Schäffer, S. A., et al. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.044069 · Cited by 69
Ultra-stable clock laser system development towards space applications
Świerad, D., Häfner, S., Vogt, S., Venon, B., Holleville, D., Bize, S., Kulosa, A., Bode, S., Singh, Y., Bongs, K., et al. (2016) · Scientific Reports · doi:10.1038/srep33973 · Cited by 67
Self-citationFifty years of commercial caesium clocks
Cutler, L. S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s10 · Cited by 62
Demonstration of a transportable 1 Hz-linewidth laser
Vogt, S., Lisdat, C., Legero, T., Sterr, U., Ernsting, I., Nevsky, A., & Schiller, S. (2011) · Applied Physics B · doi:10.1007/s00340-011-4652-7 · Cited by 61
Frequency metrology and clocks
Margolis, H. S. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154017 · Cited by 59
The relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
A compact and efficient strontium oven for laser-cooling experiments
Schioppo, M., Poli, N., Prevedelli, M., Falke, S., Lisdat, C., Sterr, U., & Tino, G. M. (2012) · Review of Scientific Instruments · doi:10.1063/1.4756936 · Cited by 56
Towards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/12800 · Cited by 56
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Bowden, W., Hobson, R., Hill, I. R., Vianello, A., Schioppo, M., Silva, A., Margolis, H. S., Baird, P. E. G., & Gill, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-48168-3 · Cited by 55
End-to-end topology for fiber comb based optical frequency transfer at the 10 −21 level
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2019) · Optics Express · doi:10.1364/oe.27.036886 · Cited by 51
Confinement of an alkaline-earth element in a grating magneto-optical trap
Sitaram, A., Elgee, P. K., Campbell, G. K., Klimov, N. N., Eckel, S., & Barker, D. S. (2020) · Review of Scientific Instruments · doi:10.1063/5.0019551 · Cited by 48
A transportable strontium optical lattice clock
Poli, N., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Cited by 45
Laser controlled atom source for optical clocks
Kock, O., He, W. J., Świerad, D., Smith, L., Hughes, J., Bongs, K., & Singh, Y. (2016) · Scientific Reports · doi:10.1038/srep37321 · Cited by 42
Self-citationSchiller, S., Görlitz, A., Nevsky, A., Alighanbari, S., Vasilyev, S., Abou-Jaoudeh, C., Mura, G., Franzen, T., Sterr, U., Falke, S., et al. (2012) · 2012 European Frequency and Time Forum · doi:10.1109/eftf.2012.6502414 · Cited by 40
Self-citationSingle-ion, transportable optical atomic clocks
Delehaye, M., & Lacroûte, C. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2018.1441917 · Cited by 40
A high-stability semiconductor laser system for a 88Sr-based optical lattice clock
Tarallo, M. G., Poli, N., Schioppo, M., Sutyrin, D. V., & Tino, G. M. (2010) · Applied Physics B · doi:10.1007/s00340-010-4232-2 · Cited by 38
Wang, S., Cao, J. Z., Yuan, J., Liu, D., Shu, H., & Huang, X.-R. (2020) · Optics Express · doi:10.1364/oe.383115 · Cited by 35
Optical-Clock-Based Time Scale.
Yao, J., Sherman, J. A., Fortier, T. M., Leopardi, H., Parker, T. E., McGrew, W. F., Zhang, X., Nicolodi, D., Fasano, R., Schäffer, S. A., et al. (2019) · PubMed · Cited by 35
Two-photon E1 - M1 optical clock
Alden, E. A., Moore, K., & Leanhardt, A. E. (2014) · Physical Review A · doi:10.1103/physreva.90.012523 · Cited by 33
Seconds-scale coherence in a tweezer-array optical clock
Norcia, M. A., Young, A. W., Eckner, W. J., Oelker, E., Ye, J., & Kaufman, A. M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.10934 · Cited by 30
Nevsky, A., Alighanbari, S., Chen, Q.-F., Ernsting, I., Vasilyev, S., Schiller, S., Barwood, G., Gill, P., Poli, N., & Tino, G. M. (2013) · Optics Letters · doi:10.1364/ol.38.004903 · Cited by 27
N -Body Efimov States from Two-Particle Noise
Nicholson, A. N. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.073003 · Cited by 26
Compact Yb+optical atomic clock project: design principle and current status
Lacroûte, C., Souidi, M., Bourgeois, P.-Y., Millo, J., Saleh, K., Bigler, E., Boudot, R., Giordano, V., & Kersalé, Y. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012025 · Cited by 26
Compact laser system for a laser-cooled ytterbium ion microwave frequency standard
Mulholland, S., Klein, H. A., Barwood, G. P., Donnellan, S., Nisbet-Jones, P. B. R., Huang, G., Walsh, G., Baird, P. E. G., & Gill, P. (2019) · Review of Scientific Instruments · doi:10.1063/1.5082703 · Cited by 23
Zhang, P., Cao, J., Shu, H.-L., Yuan, J.-B., Shang, J.-J., Cui, K.-F., Chao, S.-J., Wang, S.-M., Liu, D.-X., & Huang, X.-R. (2016) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/50/1/015002 · Cited by 16
A Review of Contemporary Atomic Frequency StandardsPreprint
Schmittberger, B. L., & Scherer, D. R. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2004.09987 · Cited by 15
A transportable optical lattice clock
Vogt, S., Häfner, S., Grotti, J., Koller, S., Al-Masoudi, A., Sterr, U., & Lisdat, C. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012020 · Cited by 13
A transportable optical lattice clock using 171Yb
Mura, G., Franzen, T., Abou-Jaoudeh, C., Görlitz, A., Luckmann, H., Ernsting, I., Nevsky, A. Y., & Schiller, S. (2013) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf-ifc.2013.6702292 · Cited by 11
Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$Preprint
Das, M., Katori, H., Ushijima, I., Takamoto, M., & Ohkubo, T. (2014) · arXiv (Cornell University) · Cited by 10
A simple atomic beam oven with a metal thermal break
Vishwakarma, C., Mangaonkar, J., Patel, K., Verma, G., Sarkar, S., & Rapol, U. D. (2019) · Review of Scientific Instruments · doi:10.1063/1.5067306 · Cited by 9
A compact and robust cooling laser system for an optical strontium lattice clock
Schwarz, R., Dörscher, S., Al-Masoudi, A., Vogt, S., Li, Y., & Lisdat, C. (2019) · Review of Scientific Instruments · doi:10.1063/1.5063552 · Cited by 8
Dubé, P., Madej, A. A., & Jian, B. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012018 · Cited by 6
A transportable strontium optical lattice clock towards space
Smith, L. (2016) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 6
Development of a Portable Optical Clock
Morris, D. C., Hill, I. R., Hendricks, R., Gaynor, P., Gill, P., Williams, R. A., Aldous, M., Gellesch, M., Jones, J. M., Kale, Y. B., et al. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856051 · Cited by 4
Self-citationDevelopment of a transportable laser cooled strontium source for future applications in space
Schioppo, M., Tino, G. M., Poli, N., Tarallo, M. G., Sutyrin, D. V., Lisdat, C., Winfred, J. S. R. V., Falke, S., Sterr, U., Legero, T., et al. (2010) · European Frequency and Time Forum · doi:10.1109/eftf.2010.6533689 · Cited by 3
Route to a Portable Optical Clock
Aldous, M., Viswam, S., Bass, J., Menchetti, M., Ubaid, Q. H., Jones, J. M., Morris, D. C., Molony, P. K., Gellesch, M., Bongs, K., et al. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597579 · Cited by 3
Self-citationThree-Dimensional Paul Trap with High Secular Frequency for Compact Optical Clock
Semerikov, I. A., Zalivako, I. V., Borisenko, A. S., Aksenov, M. A., Vishnyakov, P., Sidorov, P., Колачевский, Н. Н., & Khabarova, K. Y. (2019) · Bulletin of the Lebedev Physics Institute · doi:10.3103/s1068335619090070 · Cited by 3
A Compact Design of a Transportable Calcium Optical Frequency Standard
Xue, X., Zhang, Z., Zhang, X., Zhao, H., Wang, N.-R., Chen, X., Zhang, L., Yang, R., & Liu, D. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597454 · Cited by 2
Portable Yb Optical Lattice Clock: Towards Precision Measurement Outside the Lab
Brand, W., Fasano, R., Fox, R. W., McGrew, W. F., Hassan, Y. S., Zhang, X., Beloy, K., Nicolodi, D., & Ludlow, A. D. (2019) · Bulletin of the American Physical Society · Cited by 2
A Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Stuhl, B., Martin, K. W., Phelps, G. R., & Lemke, N. (2018) · Bulletin of the American Physical Society · Cited by 1
An atomic clock with 10-18 instability | NIST
Ludlow, A. D., Hinkley, N., Sherman, J. A., Phillips, N., Schioppo, M., Lemke, N., Beloy, K., Pizzocaro, M., & Oates, C. W. (2013) · Science · Cited by 1
Die optische Atomuhr geht in die Anwendung
Biethahn, M., & Bergner, K. (2019) · Vakuum in Forschung und Praxis · doi:10.1002/vipr.201900730 · Cited by 1
Ultra-stabile Lasersysteme für Weltraum- und Bodenanwendungen
Häfner, S. (2015) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/8470 · Cited by 1
Research works printed but not linked: 5
- [27] H. S. Margolis, ' Frequency metrology and clocks, ' J. Phys. B , vol. 42, p. 154017, 2009. - · DOI
- [57] T. A. Ely, J. Seubert, J. Prestage, et al., 2019AAS/AIAA Astrodynamics Specialist Conf. , AIAA; 2019. -
- [69] S. B. Koller, J. Grotti, S. Vogt, et al., ' Transportable optical lattice clock with 7 × 10 -17 uncertainty, ' Phys. Rev. Lett. , vol. 113, 2017, Art no. 073601. -
- [77] R. Fasano, W. Brand, R. Fox, et al., ' NISTYbportablelattice clock: updates and analysis, ' IEEE Joint Conf. IFCS-ISAF 2020 , IEEE; 2020. -
- [81] International Conference on Quantum Metrology and Sensing 9.-13. December 2019, Paris, France, Abdel Ha fi z Moustafa, Arar Bassem, Bergner Klaus, et al. Opticlock: transportable and easy-to-operate optical single-ion clock. Paris: IQuMS; December, 2019. -
Cited by
A Review of Commercial and Emerging Atomic Frequency Standards
Schmittberger, B. L., & Scherer, D. R. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3049713 · Cited by 111
“More comprehensive descriptions of optical frequency standard technologies and demonstrations can be found in recent review articles [9], [10].”
BackgroundMethodMillicharged Dark Matter Detection with Ion Traps
Budker, D., Graham, P. W., Ramani, H., Schmidt‐Kaler, F., Smorra, C., & Ulmer, S. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010330 · Cited by 89
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
Field deployable atomics package for an optical lattice clock
Kale, Y. B., Singh, A. K., Gellesch, M., Jones, J. M., Morris, D. C., Aldous, M., Bongs, K., & Singh, Y. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7b40 · Cited by 21
Self-citationPerspective: Practical atom-based quantum sensors
Brown, J. M., & Walker, T. G. (2025) · Physical Review A · doi:10.1103/q6d1-594v · Cited by 20
Metadata
- Authors
- Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y.
- Affiliations
- University of Birmingham (GB)
- Corresponding author
- Gellesch, Markus
- Singh, Yeshpal
- Venue
- Advanced Optical Technologies
- Publisher
- Frontiers Media SA
- Published
- 2019-09-23
- Volume
- 9
- Issue
- 5
- Pages
- 313-325
- ISSN
- 2192-8576 (ISSN-L)
- 2192-8584
- OpenAlex
- W3096432791
- Cited by
- 26
- References
- 89
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 2
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Advanced Optical Technologies (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- UK Quantum Technology Hub Sensors and Timing (EP/T001046/1)
- European Union (820404)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- fractional frequency instability, systematic uncertainties, low power consumption
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.