Assessment of Neonatal Encephalopathy by Amplitude-integrated Electroencephalography
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Objective.: To define normal and abnormal patterns, test interobserver variability, and the prognostic accuracy of amplitude-integrated electroencephalography (aEEG) soon after the onset of neonatal encephalopathy. Methods.: Consecutive cases of neonatal encephalopathy (n = 56; gestation median, 40; range, 35–42 weeks) and healthy infants (n = 14; gestation median, 40; range, 39–40 weeks) were studied. aEEG was recorded using a cerebral function monitor, at median, 0, range, 0–21 days of age. Of the infants, 24 of the 56 with encephalopathy and all of the normal infants were studied within 12 hours of birth (median, 5; range, 3–12 hours). Forty infants were suspected of having suffered birth asphyxia. Criteria for normal and abnormal patterns were defined and the interobserver variability of these classifications determined. Results were compared with neurodevelopmental outcome assessed at 18 to 24 months of age. aEEG also was compared with a standard EEG and with magnetic resonance imaging. Results.: The median upper margin of the widest band of aEEG activity in the control infants was 37.5 μV (range, 30–48 μV), and median lower margin was 8 μV (range, 6.5–11 μV). We classified the aEEG background activity as normal amplitude, the upper margin of band of aEEG activity >10 μV and the lower margin >5 μV; moderately abnormal amplitude, the upper margin of band of aEEG activity >10 μV and the lower margin ≤5 μV; and suppressed amplitude, the upper margin of the band of aEEG activity <10 μV and lower margin <5 μV. Recordings were analyzed further for the presence of seizures, defined as periods of sudden increase in voltage accompanied by a narrowing of the band of aEEG activity. Tests of interobserver variability showed excellent agreement both for assessment of amplitude (κ statistic = 0.85) and for identification of seizures (κ statistic = 0.76) There was a close relationship between the aEEG and subsequent outcome: 19 of 21 infants with a normal aEEG finding were normal on follow-up at 18 to 24 months of age, whereas 27 of 35 infants with a moderately abnormal or suppressed aEEG and/or seizures died or developed neurologic abnormalities. Thus, aEEG predicted outcome with a sensitivity of 0.93, a specificity of 0.70, positive predictive value of 0.77, negative predictive value of 0.90, and the likelihood ratio of a positive result of 3.1 and a negative result of 0.06. For the 24 infants studied within 12 hours of birth, the corresponding results were sensitivity, 1.0; specificity, 0.82; positive predictive value, 0.85; negative predictive value, 1; likelihood ratio of a positive result, 5.5; and likelihood ratio of a negative result, 0.18. Conclusion.: The aEEG is a simple but accurate and reproducible clinical tool that could be useful in the assessment of infants with encephalopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neonatal Encephalopathy Following Fetal Distress: A Clinical and Electroencephalographic Study
Sarnat, H. B. (1976) · Archives of Neurology · doi:10.1001/archneur.1976.00500100030012 · Cited by 2,680
The Abilities of Babies: A Study in Mental Measurement
(1955) · Journal of the American Medical Association · doi:10.1001/jama.1955.02960010090037 · Cited by 277
Prognostic Value of Background Patterns in the Neonatal EEG
Holmes, G. L., & Lombroso, C. T. (1993) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199307000-00008 · Cited by 259
Eken, P., Toet, M. C., Groenendaal, F., & de Vries, L. S. (1995) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.73.2.f75 · Cited by 220
Prognostic value of the electroencephalogram in neonatal asphyxia
Holmes, G., Rowe, J., Hafford, J., Schmidt, R., Testa, M., & Zimmerman, A. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90106-7 · Cited by 215
Rutherford, M., Pennock, J., Schwieso, J., Cowan, F., & Dubowitz, L. (1996) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.75.3.f145 · Cited by 192
Self-citationHellström-Westas, L. K., Rosén, I., & Svenningsen, N. W. (1991) · Neuropediatrics · doi:10.1055/s-2008-1071411 · Cited by 155
Prognostic Value of Early MR Imaging in Term Infants with Severe Perinatal Asphyxia
Kuenzle, C., Baenziger, O., Martin, E., Thun‐Hohenstein, L., Steinlin, M. I., Good, M., Fanconi, S., Boltshauser, E., & Largo, R. H. (1994) · Neuropediatrics · doi:10.1055/s-2008-1073021 · Cited by 133
Normal Pattern of the Cerebral Function Monitor Trace in Term and Preterm Neonates
Thornberg, E., & Thiringer, K. (1990) · Acta Paediatrica · doi:10.1111/j.1651-2227.1990.tb11324.x · Cited by 119
Monitoring of cerebral function after severe asphyxia in infancy.
Bjerre, I., Hellström-Westas, L. K., ROSEN, I. A. V., & SVENNINGSEN, N. W. (1983) · Archives of Disease in Childhood · doi:10.1136/adc.58.12.997 · Cited by 114
Cited by
Whole-body hypothermia for neonates with hypoxic-ischemic encephalopathy
Shankaran, S., Laptook, A. R., Ehrenkranz, R. A., Tyson, J. E., McDonald, S. A., Donovan, E. F., Fanaroff, A. A., Poole, W. K., Wright, L. L., Higgins, R. D., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmcps050929 · Cited by 2,862
Gluckman, P. D., Wyatt, J. S., Azzopardi, D., Ballard, R., Edwards, A. D., Ferriero, D. M., Polin, R. A., Robertson, C. M., Thoresen, M., Whitelaw, A., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17946-x · Cited by 2,270
Self-citationModerate Hypothermia to Treat Perinatal Asphyxial Encephalopathy
Azzopardi, D. V., Strohm, B., Edwards, A. D., Dyet, L., Halliday, H. L., Juszczak, E., Kapellou, O., Levene, M., Marlow, N., Porter, E., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900854 · Cited by 1,710
Self-citationRutherford, M., Ramenghi, L. A., Edwards, A. D., Brocklehurst, P., Halliday, H., Levene, M., Strohm, B., Thoresen, M., Whitelaw, A., & Azzopardi, D. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70295-9 · Cited by 600
Self-citationDoes training in obstetric emergencies improve neonatal outcome?
Draycott, T., Sibanda, T., Owen, L., Akande, V., Winter, C., Reading, S., & Whitelaw, A. (2006) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2006.00800.x · Cited by 566
Tagin, M. A., Woolcott, C. G., Vincer, M. J., Whyte, R. K., & Stinson, D. A. (2012) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpediatrics.2011.1772 · Cited by 540
Shellhaas, R. A., Chang, T., Tsuchida, T., Scher, M. S., Riviello, J. J., Abend, N. S., Nguyen, S., Wusthoff, C. J., & Clancy, R. R. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31823e96d7 · Cited by 502
Systemic Hypothermia After Neonatal Encephalopathy: Outcomes of neo.nEURO.network RCT
Simbruner, G., Mittal, R. A., Rohlmann, F., Muche, R., & neo.nEURO.network Trial Participants (2010) · Pediatrics · doi:10.1542/peds.2009-2441 · Cited by 474
Effect of Hypothermia on Amplitude-Integrated Electroencephalogram in Infants With Asphyxia
Thoresen, M., Hellström-Westas, L., Liu, X., & de Vries, L. S. (2010) · Pediatrics · doi:10.1542/peds.2009-2938 · Cited by 438
The TOBY Study Group, Azzopardi, D., Brocklehurst, P., Edwards, D., Halliday, H., Levene, M., Thoresen, M., & Whitelaw, A. (2008) · BMC Pediatrics · doi:10.1186/1471-2431-8-17 · Cited by 360
Self-citationNeonatal Hypoxia Ischaemia: Mechanisms, Models, and Therapeutic Challenges
Millar, L. J., Shi, L., Hoerder-Suabedissen, A., & Molnár, Z. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00078 · Cited by 348
Determinants of Outcomes After Head Cooling for Neonatal Encephalopathy
Wyatt, J. S., Gluckman, P. D., Liu, P. Y., Azzopardi, D., Ballard, R., Edwards, A. D., Ferriero, D. M., Polin, R. A., Robertson, C. M., Thoresen, M., et al. (2007) · Pediatrics · doi:10.1542/peds.2006-2839 · Cited by 336
Self-citationAmplitude-integrated EEG Classification and Interpretation in Preterm and Term Infants
Hellström-Westas, L., Rosén, I., de Vries, L. S., & Greisen, G. (2006) · NeoReviews · doi:10.1542/neo.7-2-e76 · Cited by 329
Thoresen, M., & Whitelaw, A. (2000) · Pediatrics · doi:10.1542/peds.106.1.92 · Cited by 321
Zhou, W.-H., Cheng, G.-Q., Shao, X.-M., Liu, X.-Z., Shan, R.-B., Zhuang, D.-Y., Zhou, C.-L., Du, L.-Z., Cao, Y., Yang, Q., et al. (2010) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2010.03.030 · Cited by 304
Moderate Hypothermia to Treat Perinatal Asphyxial Encephalopathy
Azzopardi, D. V., Strohm, B., Edwards, A. D., Dyet, L., Halliday, H. L., Juszczak, E., Kapellou, O., Levene, M., Marlow, N., Porter, E., et al. (2010) · Obstetric Anesthesia Digest · doi:10.1097/01.aoa.0000386835.73621.bb · Cited by 303
Self-citationToet, M. C., van der Meij, W., de Vries, L. S., Uiterwaal, C. S. P. M., & van Huffelen, K. C. (2002) · Pediatrics · doi:10.1542/peds.109.5.772 · Cited by 302
Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection
Shellhaas, R. A., Soaita, A. I., & Clancy, R. R. (2007) · Pediatrics · doi:10.1542/peds.2007-0514 · Cited by 293
Intervention strategies for neonatal hypoxic-ischemic cerebral injury
Perlman, J. M. (2006) · Clinical Therapeutics · doi:10.1016/j.clinthera.2006.09.005 · Cited by 264
Shankaran, S., Laptook, A., Wright, L. L., Ehrenkranz, R. A., Donovan, E. F., Fanaroff, A. A., Stark, A. R., Tyson, J. E., Poole, K., Carlo, W. A., et al. (2002) · Pediatrics · doi:10.1542/peds.110.2.377 · Cited by 263
Pilot Study of Treatment With Whole Body Hypothermia for Neonatal Encephalopathy
Azzopardi, D., Robertson, N. J., Cowan, F. M., Rutherford, M. A., Rampling, M., & Edwards, A. D. (2000) · Pediatrics · doi:10.1542/peds.106.4.684 · Cited by 261
Self-citationPrognostic Tests in Term Neonates With Hypoxic-Ischemic Encephalopathy: A Systematic Review
van Laerhoven, H., de Haan, T. R., Offringa, M., Post, B., & van der Lee, J. H. (2013) · Pediatrics · doi:10.1542/peds.2012-1297 · Cited by 257
Shalak, L. F., Laptook, A. R., Velaphi, S. C., & Perlman, J. M. (2003) · Pediatrics · doi:10.1542/peds.111.2.351 · Cited by 249
Cerebral Oxygenation and Electrical Activity After Birth Asphyxia: Their Relation to Outcome
Toet, M. C., Lemmers, P. M. A., van Schelven, L. J., & van Bel, F. (2006) · Pediatrics · doi:10.1542/peds.2005-0987 · Cited by 238
Lally, P. J., Montaldo, P., Oliveira, V., Soe, A., Swamy, R., Bassett, P., Mendoza, J., Atreja, G., Kariholu, U., Pattnayak, S., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30325-9 · Cited by 232
Azzopardi, D., Robertson, N. J., Bainbridge, A., Cady, E., Charles-Edwards, G., Deierl, A., Fagiolo, G., Franks, N. P., Griffiths, J., Hajnal, J., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00347-6 · Cited by 220
Self-citationOsredkar, D., Toet, M. C., van Rooij, L. G. M., van Huffelen, A. C., Groenendaal, F., & de Vries, L. S. (2005) · Pediatrics · doi:10.1542/peds.2004-0863 · Cited by 211
Rutherford, M. A., Azzopardi, D., Whitelaw, A., Cowan, F., Renowden, S., Edwards, A. D., & Thoresen, M. (2005) · Pediatrics · doi:10.1542/peds.2005-0328 · Cited by 209
Self-citationSummary Proceedings From the Neurology Group on Hypoxic-Ischemic Encephalopathy
Perlman, J. M. (2006) · Pediatrics · doi:10.1542/peds.2005-0620e · Cited by 200
Spitzmiller, R. E., Phillips, T., Meinzen-Derr, J., & Hoath, S. B. (2007) · Journal of Child Neurology · doi:10.1177/0883073807306258 · Cited by 196
“A total of 8 studies were used in the final meta-analysis.(12,13,30-35) The pooled results of the meta-analysis, indicating the accuracy of severe amplitude-integrated EEG tracings to predict moderate/severe disability or death, are summarized in Table 2 and Figures 2-5.”
BackgroundMethodHypoxic-Ischemic Encephalopathy: Clinical Aspects
Volpe, J. J. (2008) · Neurology of the Newborn · doi:10.1016/b978-1-4160-3995-2.10009-3 · Cited by 192
Hypoxic–ischemic brain injury in the term infant-current concepts
Shalak, L., & Perlman, J. M. (2004) · Early Human Development · doi:10.1016/j.earlhumdev.2004.06.003 · Cited by 186
“, integrated EEG [25–27] (Fig.”
Preterm Hypoxic–Ischemic Encephalopathy
Gopagondanahalli, K. R., Li, J., Fahey, M. C., Hunt, R. W., Jenkin, G., Miller, S. L., & Malhotra, A. (2016) · Frontiers in Pediatrics · doi:10.3389/fped.2016.00114 · Cited by 160
“Amplitude-integrated electroencephalogram (aEEG)/electroencephalogram (EEG) are powerful tools for the diagnosis and prediction of neurological outcomes in asphyxiated infants (79, 80).”
Background
Metadata
- Authors
- al Naqeeb, N., Edwards, A. D., Cowan, F. M., & Azzopardi, D.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1999-06-01
- Volume
- 103
- Issue
- 6
- Pages
- 1263-1271
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2101412811
- Cited by
- 458
- References
- 11
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.