The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Open accessAbstract
User acceptance of myoelectric forearm prostheses is currently low. Awkward control, lack of feedback, and difficult training are cited as primary reasons. Recently, researchers have focused on exploiting the new possibilities offered by advancements in prosthetic technology. Alternatively, researchers could focus on prosthesis acceptance by developing functional requirements based on activities users are likely to perform. In this article, we describe the process of determining such requirements and then the application of these requirements to evaluating the state of the art in myoelectric forearm prosthesis research. As part of a needs assessment, a workshop was organized involving clinicians (representing end users), academics, and engineers. The resulting needs included an increased number of functions, lower reaction and execution times, and intuitiveness of both control and feedback systems. Reviewing the state of the art of research in the main prosthetic subsystems (electromyographic [EMG] sensing, control, and feedback) showed that modern research prototypes only partly fulfill the requirements. We found that focus should be on validating EMG-sensing results with patients, improving simultaneous control of wrist movements and grasps, deriving optimal parameters for force and position feedback, and taking into account the psychophysical aspects of feedback, such as intensity perception and spatial acuity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
(1985) · Journal of Affective Disorders · doi:10.1016/0165-0327(85)90062-x · Cited by 1,254
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
(2009) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir.2009.04936dae.001 · Cited by 432
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Vibrotactile localization on the arm: Effects of place, space, and age
Cholewiak, R. W., & Collins, A. A. (2003) · Perception & Psychophysics · doi:10.3758/bf03194834 · Cited by 325
Online Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Information Transmission by Phantom Sensations
Alles, D. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299967 · Cited by 269
The MANUS-HAND Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects
Pons, J. L., Rocon, E., Ceres, R., Reynaerts, D., Saro, B., Levin, S., & Van Moorleghem, W. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016862.38337.f1 · Cited by 266
Sensinger, J. W., Lock, B. A., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023282 · Cited by 239
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
Vibrotactile Frequency Discrimination in Human Hairy Skin
Mahns, D. A., Perkins, N. M., Sahai, V., Robinson, L., & Rowe, M. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00483.2005 · Cited by 231
Hargrove, L. J., Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039590 · Cited by 219
Human Limbs and Their Substitutes
(1955) · Physical Therapy · doi:10.1093/ptj/35.5.276a · Cited by 201
A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis
Karlik, B., Tokhi, M. O., & Alci, M. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.818469 · Cited by 198
Upper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Staudenmann, D., Kingma, I., Daffertshofer, A., Stegeman, D. F., & vanDieen, J. H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870246 · Cited by 172
Hargrove, L. J., Losier, Y. G., Lock, B. A., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353424 · Cited by 170
Real-time intelligent pattern recognition algorithm for surface EMG signals
Khezri, M., & Jahed, M. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-45 · Cited by 166
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Intelligent multifunction myoelectric control of hand prostheses
Light, C. M., Chappell, P. H., Hudgins, B., & Engelhart, K. (2002) · Journal of Medical Engineering & Technology · doi:10.1080/03091900210142459 · Cited by 153
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Yang, D., Zhao, J., Gu, Y., Wang, X., Li, N., Jiang, L., Liu, H., Huang, H. Y., & Zhao, D. (2009) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(08)60119-5 · Cited by 141
A Haptic Feedback System for Lower-Limb Prostheses
Fan, R. E., Culjat, M. O., King, C., Franco, M. L., Boryk, R. J., Bisley, J. W., Dutson, E., & Grundfest, W. S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.920075 · Cited by 138
Soares, A. B., Andrade, A. D. O., Júnior, E. A. L., & Carrijo, R. S. (2003) · Journal of Intelligent Information Systems · doi:10.1023/a:1024758415877 · Cited by 135
Human limbs and their substitutes
(1956) · The American Journal of Surgery · doi:10.1016/0002-9610(56)90428-7 · Cited by 120
Extended physiologic taction: design and evaluation of a proportional force feedback system.
Meek, S. G., Jacobsen, S. C., & Goulding, P. P. (1989) · PubMed · Cited by 118
Sebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 117
Smith, R. J., Tenore, F. V., Huberdeau, D. M., Etienne‐Cummings, R., & Thakor, N. V. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649124 · Cited by 114
Pino, G. D., Guglielmelli, E., & Rossini, P. M. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.03.001 · Cited by 111
Solomonow, M., Lyman, J., & Freedy, A. (1977) · Annals of Biomedical Engineering · doi:10.1007/bf02409338 · Cited by 108
Kinesthetic Sensing for the EMG Controlled "Boston Arm"
Mann, R. W., & Reimers, S. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299971 · Cited by 108
Sensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 104
Hand Prosthesis Control Via Myoelectric Patterns
Herberts, P., Almström, C., Kadefors, R., & Lawrence, P. D. (1973) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677308989075 · Cited by 97
Continuous multifunction myoelectric control using pattern recognition
Englehart, K. B., Hudgins, B. S., & Chan, A. D. C. (2003) · Technology and Disability · doi:10.3233/tad-2003-15205 · Cited by 94
Progress in the development of a multifunctional hand prosthesis
Pylatiuk, C., Mounier, S., Kargov, A., Schulz, S., & Bretthauer, G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404187 · Cited by 94
A comparison of alternative means of providing sensory feedback on upper limb prostheses
Shannon, G. F. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478123 · Cited by 93
Luca, C. J. D. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd097 · Cited by 93
A myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92
Vibrotactile transduction and transducers
Mortimer, B. J. P., Zets, G. A., & Cholewiak, R. W. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2715669 · Cited by 92
Invasive neural prosthesis for neural signal detection and nerve stimulation
Gasson, M. N., Hutt, B., Goodhew, I., Kyberd, P., & Warwick, K. (2004) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.854 · Cited by 76
Intermittent Stimulation Delays Adaptation to Electrocutaneous Sensory Feedback
Buma, D. G., Buitenweg, J., & Veltink, P. (2007) · IEEE transactions on neural systems and rehabilitation engineering · doi:10.1109/tnsre.2007.903942 · Cited by 69
Self-citationAlmstr�m, C., Herberts, P., & K�rner, L. (1981) · International Orthopaedics · doi:10.1007/bf00286094 · Cited by 67
Pfeiffer, E. A. (1968) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474726 · Cited by 67
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
A scenario guideline for designing new teletreatments: a multidisciplinary approach
Huis in 't Veld, R. M., Widya, I. A., Bults, R. G., Sandsjö, L., Hermens, H. J., & Vollenbroek-Hutten, M. M. (2010) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2010.006003 · Cited by 62
Self-citationDesign breakdowns, scenarios and rapid application development
Beynon‐Davies, P., & Holmes, S. (2002) · Information and Software Technology · doi:10.1016/s0950-5849(02)00078-2 · Cited by 56
Artificial touch in a hand-prosthesis
Beeker, T. W., During, J., & den Hertog, A. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478841 · Cited by 55
Enhanced EMG signal processing for simultaneous and proportional myoelectric control
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. K. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332745 · Cited by 54
Hargrove, L. J., Zhou, P., Englehart, K. B., & Kuiken, T. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010392 · Cited by 49
Tashiro, T., & Higashiyama, A. (1981) · Perception & Psychophysics · doi:10.3758/bf03202013 · Cited by 48
A 16-channel 8-parameter waveform electrotactile stimulation system
Kaczmarek, K. A., Kramer, K. M., Webster, J. G., et al. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.88439 · Cited by 46
Two-channel enhancement of a multifunction control system
Kuruganti, U., Hudgins, B., & Scott, R. N. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362912 · Cited by 46
Supplemental sensory feedback for the VA/NU myoelectric hand. Background and preliminary designs.
Prior, R. E., Lyman, J., Pa, C., & Cm, S. (1976) · PubMed · Cited by 41
Arvetti, M., Gini, G. C., & Folgheraiter, M. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428476 · Cited by 39
Marcus, P. L., & Fuglevand, A. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066008 · Cited by 35
Sensory feedback for powered limb prostheses
Rohland, T. A. (1975) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477743 · Cited by 34
Pons, J. L., Ceres, R., Rocón, E., Reynaerts, D., Saro, B., Levin, S., & Moorleghem, W. V. (2005) · Robotica · doi:10.1017/s0263574704001328 · Cited by 33
Anani, A., & Körner, L. K. (1979) · PubMed · Cited by 33
The Control of upper-extremity prostheses and orthoses
Herberts, P. (1974) · Thomas eBooks · Cited by 32
Channel and Feature Selection in Multifunction Myoelectric Control
Khushaba, R. N., & Al-Jumaily, A. A. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353509 · Cited by 31
The importance of information feedback in prostheses for the upper limbs/1
Schmidt, H. (1977) · Prosthetics and Orthotics International · doi:10.3109/03093647709164601 · Cited by 28
Real-time control of a virtual hand
Sebelius, F., Axelsson, M., Danielsen, N., Schouenborg, J., & Laurell, T. (2005) · Technology and Disability · doi:10.3233/tad-2005-17301 · Cited by 27
Gripping force sensory feedback for a myoelectrically controlled forearm prosthesis
Wang, G., Zhang, X., Zhang, J., & Gruver, W. A. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1995.537810 · Cited by 24
Pilot Comparison of Surface vs. Implanted EMG for Multifunctional Prosthesis Control
Farrell, T. R., & Weir, R. F. F. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501101 · Cited by 22
Differentiating Type of Muscle Movement via AR Modeling and Neural Network Classification
Karlık, B. (1999) · Cited by 20
An embedded controller for a 7-degree of freedom prosthetic arm
Tenore, F. V., Armiger, R. S., Vogelstein, R. J., Wenstrand, D. S., Harshbarger, S. D., & Englehart, K. B. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649121 · Cited by 20
Ito, K., Tsuji, T., Kato, A., & Itō, M. (1991) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.1991.170562 · Cited by 19
Application of Support Vector Machines in upper limb motion classification using myoelectric signals
Oskoei, M. A., & Hu, H. (2007) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2007.4522193 · Cited by 17
Discrimination of Forearm's Motions by Surface EMG Signals using Neural Network.
Itakura, N., Kinbara, Y., Fuwa, T., & Sakamoto, K. (1996) · Applied Human Science Journal of Physiological Anthropology · doi:10.2114/jpa.15.287 · Cited by 9
Cited by
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“However, average results are usually below 80–90% (Peerdeman et al., 2011).”
BackgroundEMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Metadata
- Authors
- Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2011
- Volume
- 48
- Issue
- 6
- Pages
- 719
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2977419794
- Cited by
- 469
- References
- 93
- FWCI
- 17.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.