The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use
Abstract
Using electromyogram (EMG) signals to control upper-limb prostheses is an important clinical option, offering a person with amputation autonomy of control by contracting residual muscles. The dexterity with which one may control a prosthesis has progressed very little, especially when controlling multiple degrees of freedom. Using pattern recognition to discriminate multiple degrees of freedom has shown great promise in the research literature, but it has yet to transition to a clinically viable option. This article describes the pertinent issues and best practices in EMG pattern recognition, identifies the major challenges in deploying robust control, and advocates research directions that may have an effect in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Assessing Wolf Motor Function Test as Outcome Measure for Research in Patients After Stroke
Wolf, S. L., Catlin, P. A., Ellis, M., Archer, A. L., Morgan, B., & Piacentino, A. (2001) · Stroke · doi:10.1161/01.str.32.7.1635 · Cited by 1,051
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Self-citationMyoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Self-citationClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Self-citationHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Self-citationKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Self-citationEpidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Self-citationHargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Self-citationLucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Sensinger, J. W., Lock, B. A., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023282 · Cited by 239
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationKopp, B., Kunkel, A., Flor, H., Platz, T., Rose, U., Mauritz, K.-H., Gresser, K., McCulloch, K. L., & Taub, E. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90427-5 · Cited by 214
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
Self-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Modulation of Muscle Synergy Recruitment in Primate Grasping
Overduin, S. A., d'Avella, A., Roh, J., & Bizzi, E. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2869-07.2008 · Cited by 190
Upper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Hargrove, L. J., Losier, Y. G., Lock, B. A., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353424 · Cited by 170
Self-citationImproved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers
Hijjawi, J. B., Kuiken, T., Lipschutz, R. D., Miller, L. A., Stubblefield, K. A., & Dumanian, G. A. (2006) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000242487.62487.fb · Cited by 163
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Self-citationMuscle synergies as a predictive framework for the EMG patterns of new hand postures
Ajiboye, A. B., & Weir, R. F. F. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036004 · Cited by 159
Farrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
The effect of electrode displacements on pattern recognition based myoelectric control
Hargrove, L. J., Englehart, K. B., & Hudgins, B. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260681 · Cited by 153
Self-citationMomen, K., Krishnan, S., & Chau, T. T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908376 · Cited by 153
Montoya, P., Ritter, K., Huse, E., Larbig, W., Braun, C., Töpfner, S., Lutzenberger, W., Grodd, W., Flor, H., & Birbaumer, N. (1998) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1998.00122.x · Cited by 144
Simon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2155063 · Cited by 123
Kang, W.-J., Shiu, J.-R., Cheng, C., Lai, J., Tsao, H., & Kuo, T. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398638 · Cited by 117
Fluctuating emg signals: Investigating long-term effects of pattern matching algorithms
Kaufmann, P. M., Englehart, K. B., & Platzner, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627288 · Cited by 115
Self-citationSmith, R. J., Tenore, F. V., Huberdeau, D. M., Etienne‐Cummings, R., & Thakor, N. V. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649124 · Cited by 114
Assessment of Capacity for Myoelectric Control: a new rasch-built measure of prosthetic hand control
Hermansson, L., Fisher, A. G., Bernspång, B., & Eliasson, A. (2004) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410024280 · Cited by 113
The control of a prosthetic arm by EMG pattern recognition
Lee, S., & Saridis, G. N. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103521 · Cited by 109
REAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 102
Self-citationContinuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors
Baker, J. J., Scheme, E., Englehart, K. B., Hutchinson, D. T., & Greger, B. E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047590 · Cited by 80
Self-citationAutomatic recognition of sign language subwords based on portable accelerometer and EMG sensors
Li, Y., Chen, X. '., Tian, J., Zhang, X., Wang, K., & Yang, J. (2010) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/1891903.1891926 · Cited by 76
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Occupational therapy protocol for amputees with targeted muscle reinnervation
Stubblefield, K. A., Miller, L. A., Lipschutz, R. D., & Kuiken, T. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.10.0138 · Cited by 66
Yang, D., Zhao, J., Gu, Y., Jiang, L., & Liu, H. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354544 · Cited by 60
Simulation of Intramuscular EMG Signals Detected Using Implantable Myoelectric Sensors (IMES)
Lowery, M. M., Weir, R. F. F., & Kuiken, T. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881774 · Cited by 55
Simultaneous, Proportional, Multi-axis Prosthesis Control using Multichannel Surface EMG
Yatsenko, D., McDonnall, D., & Guillory, K. S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353749 · Cited by 54
Feature-based classification of myoelectric signals using artificial neural networks
Gallant, P. J., Morin, E. L., & Peppard, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523219 · Cited by 51
Armiger, R. S., & Vogelstein, R. J. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696889 · Cited by 49
Using EMG to Anticipate Head Motion for Virtual-Environment Applications
Barniv, Y., Aguilar, M., & Hasanbelliu, E. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.848378 · Cited by 44
Weir, R. F. F., Troyk, P. R., DeMichele, G. A., & Kerns, D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616206 · Cited by 41
Two-channel enhancement of a multifunction control system
Kuruganti, U., Hudgins, B., & Scott, R. N. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362912 · Cited by 41
Surface EMG Signal Classification Using a Selective Mix of Higher Order Statistics
Nazarpour, K., Sharafat, A. R., & Firoozabadi, M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615392 · Cited by 34
EMG pattern recognition control of multifunctional prostheses by transradial amputees
Li, G., & Kuiken, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333628 · Cited by 34
Losier, Y. G., Englehart, K. B., & Hudgins, B. S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0165 · Cited by 28
Self-citationBishop, W. E., Armiger, R. S., Burck, J. M., Bridges, M., Hauschild, M., Englehart, K. B., Scheme, E., Vogelstein, R. J., Beaty, J. D., & Harshbarger, S. D. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649228 · Cited by 27
Self-citationDevelopment of clinician-friendly software for musculoskeletal modeling and control
Davoodi, R., Urata, C., Todorov, E. V., & Loeb, G. E. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404281 · Cited by 20
A FLEXIBLE USER INTERFACE FOR RAPID PROTOTYPING OF ADVANCED REAL-TIME MYOELECTRIC CONTROL SCHEMES
Scheme, E., & Englehart, K. B. (2008) · DukeSpace (Duke University) · Cited by 18
Self-citation
Cited by
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Pattern recognition algorithms are used to classify the movement that the subject aims to perform according to a label (Scheme and Englehart, 2011).”
BackgroundComparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Metadata
- Authors
- Scheme, E., & Englehart, K.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2011
- Volume
- 48
- Issue
- 6
- Pages
- 643
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2171188488
- Cited by
- 969
- References
- 65
- FWCI
- 20.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.